Tender For Construction Of 2 Nos E Type Staff Quarter (S+1) With Foundation For 3 Storied (For Future Expansion) At Pwd Colony-2 At Rayagada (Civil,Ei And Gph.) Buildings.
Tender Value
1.50 Crore
Estimated cost
Bid Submission
10 Dec 2026
11 days left
EMD
1.51 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rayagada → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 2 Nos E Type Staff Quarter (S+1) With Foundation For 3 Storied (For Future Expansion) At Pwd Colony-2 At Rayagada (Civil,Ei And Gph.) Buildings.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling and removing of CB Brick / Stone masonary walls including stacking the useful materials for reuse and removing the derbies within 50m lead including cost, conveyance, of all materials with all labour and T&P required for the work etc. complete in all floors as per standard specification and direction of Engineer in charge. |
| 2 | Dismantling and removing of AC sheet roofing including stacking the useful materials for reuse and removing the derbies within 50m lead including cost, conveyance, of all materials with all labour and T&P required for the work etc. complete in all floors as per standard specification and direction of Engineer in charge. |
| 3 | Dismantling and removing of RCC columns / beams slab stair case landing lintels including stacking the useful materials for reuse and removing the derbies within 50m lead including cost, conveyance, of all materials with all labour and T&P required for the work etc. complete in all floors as per standard specification and direction of Engineer in charge. |
| 4 | Dismantling & removing cement concrete including stacking the useful materials for reuse and removing the debries within 50m lead. including cost, conveyance, of all materials with all labour and T&P required for the work etc. complete in all floors as per standard specification and direction ofEngineer in charge. |
| 5 | Dismantling and removing doors, windows and ventilators including removal of frame hinges fastening and stacking the same for reuse and removing the debries within 50m lead. including cost, conveyance, of all materials with all labour and T&P required for the work etc. complete in all floors as per standard specification and direction ofEngineer in charge. |
| 6 | Dismantling & removing marble chips flooring including stacking the useful materials for reuse and removing the debries within 50m lead. including cost, conveyance, of all materials with all labour and T&P required for the work etc. complete in all floors as per standard specification and direction of Engineer in charge. |
| 7 | Clearing and grubbing land including uprooting rank vegetation, grass,bushes, shrubs, saplings and tree girth upto 300 mm, removal of stumpsoftrees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned upto a lead of 1000 meters including removal and disposal of top organic Soil notexceeding 150mm in thickness as per clause 201 of MORT&H Spesifications for Road & Bridge works |
| 8 | Earth work in foundation in hard soil or gravelly soil within 50m intial lead and lifts 1.5 M intial lifts including dressing and leveling the bed and depositing the excavated earth at places away from work site including cost of all labour, T&P and dewatering if required for the work etc. complete as per drawing and Technical specification and as directed by the Engineer-in-Charge. |
| 9 | Earth work in filling in foundation and plinth with excavated materials / Earth within initial lead of 50.00mtr. & initial lift of 1.5 mtr. including cost of all labour T&P, watering and ramming as directed by the Engineer in charge.STILT FLOOR |
| 10 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge.STILT FLOOR |
| 11 | Providing and laying (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and sand of approved quality and from approved quarry including laying concrete in layers not exceeding 15cm in depth, ramming, watering and curing etc. complete to required levels including cost, conveyance, royalties, taxes of all materials and cost of all labours, T&P etc complete as per the direction of the Engineer in charge.STILT FLOOR |
| 12 | Providing and laying (1:2:4) in foundation and floors using 12mm size black hard crusher broken granite stone metal and sand of approved quality and from approved quarry including laying concrete in layers not exceeding 15cm in depth, ramming, watering and curing etc. complete to required levels including cost, conveyance, royalties, taxes of all materials and cost of all labours, T&P etc complete as per the direction of the Engineer in charge. |
| 13 | Fly ash brick masnory (23 x 11 x 8) cm in C.M (1:6) in Foundation & Plinth using bricks of 23cm size having a crushing strength of not less than 75 kg per Sq.cm, after immersing Bricks for six hours in waters before use with watering, curing etc. complete including cost, conveyance, royalties, taxes of all materials, cost of all labour, all T&P etc. complete in all respect as directed by theEngineer in charge.STILT FLOOR |
| 14 | R.C.C work of M-20 grade in Structural building works using 20mm to 10mm down graded hard black granite Crusher broken aggregates of approved quality from approved quarry including all taxes in complete.STILT FLOORColumn Base |
| 15 | Plinth Beam |
| 16 | Column |
| 17 | Lintle |
| 18 | Chajja |
| 19 | Stair case |
| 20 | Roof Slab |
| 21 | FIRST FLOOR Column |
| 22 | Lintle |
| 23 | Chajja |
| 24 | Stair case |
| 25 | Roof Slab |
| 26 | HEAD ROOMColumn |
| 27 | Lintle |
| 28 | Roof Slab |
| 29 | Supplying fitting and placing uncoated HYSD Steel reinforcement works using HYSD (FE-415/ 500 / 550) steel of approved manufacturer as per section 1600 §ion 1900 of MORT&H specification for Road and Bridge works ( 4th revision) including cost, conveyance and taxes of all materials, binding wires 18 to 20 gauge and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge.STILT FLOOR |
| 30 | FIRST FLOOR |
| 31 | HEAD ROOM |
| 32 | Flyash brick masnory (23 x 11 x 8) cm in C.M (1:6) in super structure including with all cost etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge.STILT FLOOR |
| 33 | FIRST FLOOR |
| 34 | HEAD ROOM |
| 35 | 16 mm thick Cement Plaster (1:6) finished smooth to masonry brick walls after raking out the joint including watering and curing with cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer in charge.STILT FLOOR |
| 36 | FIRST FLOOR |
| 37 | HEAD ROOM |
| 38 | 12 mm (1/2\\") thick Cement Plaster (1:6) finished smooth to masonry brick walls in complete in all respect as per drawing and Technical Specification and as directed by the Engineer in charge.STILT FLOOR |
| 39 | FIRST FLOOR |
| 40 | HEAD ROOM |
| 41 | 6mm thick cement plaster (1:4) over RCC works including deep chipping, finished smooth with proper thickness, watering, curing for required days with cost, conveyance, royality, taxes of all materials and labour with T&P required or the work etc. complete in all respect as per drawing and technical specification and as directed by the Engineer in charge.STILT FLOOR |
| 42 | FIRST FLOOR |
| 43 | HEAD ROOM |
| 44 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride(UPVC) (FENESTA/NCL VEKA LTD) Casement Window with top fixed 60-Series duly Manufactured using UPVC reinforced profiles of 60mm x 55 mm x 2.5 mm for outer frames, 75mm x 60mm x 2.25mm for Casement Door Sash profile and 74mm x 60mm x 2.5mm mullion profile capable of mounting single glazing system, structurally reinforced hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the door sash shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed With EPDM weathering seal resistant accessories like clipping locking syetem made of aluminium 1 No. , per sheet of sashes and the system is to be installed using anchor fasteners, sliicon rubber sealant, easy glazing/deglazing at site etc., including cost and conveyance of all materials, labour charges, materials and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards. (Lr. No. 16100 dtd. 08.05.2018 of EIC) Rate per 1 SqmSTILT FLOOR |
| 45 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD.) Casement Door 60- Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 102 mm x 60 mm x 2.25 mm for casement Door Sash Profile and 74 mm x 60 mm x 2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 2.0 mm prefabricated & welded through fusion welding the door sash shall be fitted with 12mm thick WPC Board of Greenply make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 63814,EN 477 95 and other applicable codes and standards.(D and D4) etc complete as per direction of Engineer in charge.FIRST FLOOR |
| 46 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride(UPVC) (FENESTA/NCL VEKA LTD) Three Track-Three Panel sliding window 60-Series duly Manufactured using UPVC reinforced profiles of 108mm x 45 mm x 2.5 mm for outer frames and Window Sash of 39 mm x 58 mm x 2.5 mm capable of mounting Single glazing system, structurally reinforced hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window frame shall be fitted with 6 mm clear toughened glass of SAINT-GOBAIN make duly fixed With EPDM weathering seal resistant and the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, sliicon rubber sealant, easy glazing/deglazing at site etc., including cost and conveyance of all materials, labour charges, materials and product conforming to ASTM D 638-14, EN47795 and other applicable codes and standards. (Lr. No. 16100 dtd. 08.05.2018 of EIC) Rate per 1 SqmFIRST FLOOR |
| 47 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) ( FENESTA / NCL VEKA LTD.) Ventilator/ Top Hung 60 Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Window Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN 4795 and other applicable codes and standards (V) etc complete as per direction of Engineer in charge.FIRST FLOOR |
| 48 | Painting two coats with any approved colour of weather seal coat over a coat of Water Bound Wall cement Primer to out side surface of wall including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer in charge. STILT FLOOR |
| 49 | Supplying, fitting & fixing of Supplying, fitting and fixing Vertified Tile 600mm x 600mm plain (Ivory) of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer in charge.STILT FLOOR |
| 50 | FIRST FLOOR |
| 51 | Supplying, fitting & fixing of Vertified Tile 600mm x 600mm plain (Ivory) of approved make in dadoes, skirting laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of theEngineer in charge.STILT FLOOR |
| 52 | FIRST FLOOR |
| 53 | Supplying, fitting and fixing chequered tile of approved make conforming to is:13755 laid on 20mm thick cement mortar (1:4) (1 cement :4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction ofEngineer in charge.STILT FLOOR |
| 54 | Supplying, fitting, fixing of Granite tiles of size 0.1 to 0.4sqm (Pulished) in floors over 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost, conveyance and taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer in charge.. |
| 55 | Providing fitting and fixing of Stainless steel hand rail in stair case and approved design including cost , conveyance, taxes etc complete as per direction of Engineer in charge. |
| 56 | Providing fitting & fixing of M.S iron grill including cost, conveyance and taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge. |
| 57 | Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge.FIRST FLOOR |
| 58 | HEAD ROOM |
| 59 | Painting two coats with plastic emulsion paint over a coat of water bond cement primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-chargeFIRST FLOOR |
| 60 | HEAD ROOM |
| 61 | Painting two coat of Weather coat over a coat of primer of approved shade on new works to give an even shade over prepared surfaces including scuffolding to outside walls, including cost and conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in- Charge.FIRST FLOOR |
| 62 | HEAD ROOM |
| 63 | Painting two coat with approved Synthetic enamel Paint on steel work to make in even finished surfaces in all floors and heights to Iron surface of approved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge.FIRST FLOOR |
| 64 | HEAD ROOM |
| 65 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge.FIRST FLOOR |
| 66 | HEAD ROOM |
| 67 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete |
| 68 | Supplying and fitting-fixing of Dressed seasoned sal woood work framed and fixed (wrougth and put up) in frames of doors, windows & ventilators including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 69 | Painting two coat with approved Synthetic enamel Paint on Wood work to make in even finished surfaces in all floors and heights to Iron surface of approved make and shade including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. |
| 70 | Providing, Fitting & Fixing of 100mm dia PVC Rain water pipe with cost, conveyance, royalties and taxes of all materials with cost of all labour, and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 71 | EI WORKSRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Each lightpoint should have provision for ceiling rose and angle holder point. In all the rooms there shall be two types of switchboard- one for raw and the other one for inverter. The inverter switchboard shall include atleast one fan, one light and other emergency sockets. Each quarter shall have 2 separte Dbs- one for raw and the other one for inverter. GROUP-A(QTRS) |
| 72 | GROUP-B(QTRS) |
| 73 | GROUP-C(COMMON AREA) |
| 74 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 75 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 76 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 77 | Supplying,fixing of 2 x 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius )/Panasonic (vision)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 78 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (2X1.5+1X1.5) |
| 79 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (2X2.5+1X1.5) |
| 80 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit (2X4+1X1.5) |
| 81 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit . (2X6+1X2.5) |
| 82 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 83 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 84 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 85 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 86 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 87 | Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.( REGULATOR COMPATIBLE) |
| 88 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 89 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 90 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 91 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years.(To be used in parking, corridor area etc.) |
| 92 | SITC of energy efficient LED 60Watt,5700K LED well glass equiped with isolated electronics driver suitable for industrial application,,IP65,IK 10 ,110 lm/w medium bay heighted LED downlighter with all required accessories as required. (For area Lighting) (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) |
| 93 | Supply and fixing of 16 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (RAW DB) |
| 94 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years (INVERTER DB) |
| 95 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9./ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 years. |
| 96 | Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 97 | Supplying and fixing 25 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9./ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 98 | Supply and fixing of 63A 220V automatic over/under voltage, overload protection device with protection range 230-300V (Overvolatge), 80-210 V(Undervoltage), autoreconnect, adjustable device in complete as per the direction of Engineer-in-charge.Make-AMICI smart/Legrand/Siemens/Schneider/ABB |
| 99 | Supplying and fixing 25-63amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 100 | (Earthing) INSTALLATION:- S/IT/C Of Earthing withG.I earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. |
| 101 | Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 102 | Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 103 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make-Polycab/KEI/Finolex/Havells/RR kabel/Gloster/V-Guard |
| 104 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 105 | EXTERNAL ILLUMINATION For all the quarters Supply of Elegant look 60 W AIO LED Solar Street lights having extruded alluminium housing, 180Wp or more (subjected to final panel backup calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) Mono Crystalline Panel/Laminates fixed on the top of the luminaire housing, maintenance free 12.8 volts 78 Ah or more (subjected to final battery calculation with dimming profile of 100% output for 2 hrs, 90% output for 1 hr, 60% output for 1 hr and 50% output for 8 hrs per day. The calculation is to approved by SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR before final procurement of the product.) LiFePO4 battery(BIS certified) , BMS, MPPT charge controller, PIR sensor( when there will be no movement the lumens output will be 30% output).The solar panel and battery should be designed to provide 2 days (24 hrs ) back up . The luminaire is having IP 65 protection for critical components, IK 08 and having lumen output of >=10000 lumens as per LM 79 report third party/central/state govt accredited NABL lab to justify the lumen output & lumen efficacy . Lenses should be provided on the LED chip for better lighting dstribution to avoid glare on human eyes. Both the luminaire and Mono Crystalline Panel must be manufactured in India. The Solar lighting company must submit the third party central/state govt accredited NABL lab reports to justify the lumen efficacy,luminaire output , IK 08 and IP 65 protection.The Luminaire should be supplied along with adjustable type mounting bracket which can be fitted directly on the pole.The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. |
| 106 | The Solar lighting manufacturer must submit the declaration letter by mentioning that complete solar light and the solar panel are manufactured in India and warranty certificate on their company's letterhead by mentioning warranty period as 5 years and necessary aftersales Service will be provided through their tollfree base service network located within 100 KM from the project site. The Solar Street light manufacturer should have own NABL accredieted laborotory. The following test reports must be submitted and approved from SE,Electrical Circle (R&B) and CE ,Buildings, Odisha, BBSR for the technical acceptance of the products.1.LM 79 REPORT and LM 80 Report ( from third party/central/state govt accredited NABL lab of AIO solar light) , 2. IK 08 ( from third party/central/state govt accredited NABL lab of AIO solar light ) , 3. IP 65 (Report of third party/central/state govt accredited NABL lab of AIO solar light 4. EN50530 MPPT Efficiency , 5. IEC61547 , 6. IEC61000-3-2 EMC , 7. IEC 60598-2-3 ,8. IEC 62109-1, ( The necessary test reports of third party/central/state govt accredited NABL lab from sl no. 4 to sl no.8 must be submitted for any wattage of AIO solar light )Make-(Philips/Panasonict/Wipro/Crompton/Bajaj/Havells/LT ). NB: The cost includes 5 years CMC including repair/ Maintenance/ replacement of the product in case of any defect. Installation of 6 mtr pole on the foundation after fixing the 60 W AIO Light in the pole by using suitable machinery by taking all safety precautions as per the direction of EIC. |
| 107 | Supply of 6 mtr long hot dip galvanized Octagonal pole having base dia of 155 mm and top dia of 70 mm and plate thick ness of 4 mm or more. complete with base plate 260x260x16 mm and 4 nos. Jtype En 8 grade foundation bolts (M24X750 mm) to withstand 180 KM / HR or more wind speed considering the weight & dimension of 1 nos 60 W AIO Solar light to be fitted in the top of the pole .The bidder shall also furnish wind load test report of the solar fixture and wind load test of the pole considering the weight and dimension of 1 no 60 W AIO Solar light to be fitted in the pole to sustain wind speed of 180km/hr or more from third party /central/state govt accredited NABL lab after award of the work.( For solar)(Make - Bajaj/RR ispat//Valmont/Vakrangee/Utkarsh) |
| 108 | Construction of RCC foundation by using M20 grade RCC and Fe415 grade reinforcement in the foundation by considering the SBC as 10 T Per sq mtr and fixing 4 nos. EN8 grade foundation bolts in that foundation and installation of the pole with solar light on that foundation using suitable machinery. The work shall be executed as per the instruction of Eng-in-charge. The structural calculation and civil foundation shall be duly approved by competant authority from civil wing before execution of the work. |
| 109 | Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge. Make-Safex/Fireshield/Ceasefire/FLAMEKLOG |
| 110 | Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. Make-Safex/Fireshield/Ceasefire/FLAMEKLOG |
| 111 | SITC of 2 kg capacity Eco friendly stored pressure type filled with HFC 236(Clean agent fire extinguisher having zero ozone depletion potential) clean agent fire extinguisher s with safety seal,pressure gauge, controlable discharge mechanism helium leak detection tested and confirming to IS:15683 complete with initial charge as required. Make : Fireshield/Kanex/ Safex/ ceasefire/Flameklog |
| 112 | SIGNAGES: SITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages |
| 113 | Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make- AKG/ BEC/ Precision/ Norpack/ Kinjal. (Only for data/ telephone/ CCTV) 20mm dia |
| 114 | Supply and installation of Metering Unit panel Board of size 56x48x12 with 40Amp C series DP MCB of (Legrand/ L&T/Hager)make-6Nos.,. With channels for fitting ,fixing for Digital meter within it. |
| 115 | Supply Installation Testing and Commissioning of 10 kVA, single phase hybrid Solar Photovoltaic Power Plant,having Solar tubular battery, 550W ,20 nos. solar panel conforming to MNRE specifications as amended, consisting of Mono PERC HALF CUT bifacial Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on hot dip GI structure( solar panel bottom height from roof level shall not be less than 300mm, accordingly GI structure to be designed) of suitable strength with following components a complete as arequired: a) Solar Photovoltaic Module of capacity 550Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 22. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80 at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz /- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Tata/waree/luminous/adani/panasonic. The entire SOLAR system should be Replacement Warranty will be 5 years |
| 116 | PH WORKSProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge (Supream/Ashirvad/Oriplasto/Equivalent) 20mm dia C - PVC pipe SDR - 11(First Floor) |
| 117 | 25mm dia C - PVC pipe SDR - 11(First Floor) |
| 118 | 32mm dia C - PVC pipe SDR - 11 top Floor |
| 119 | 40mm dia C - PVC pipe SDR - 11 top Floor |
| 120 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.(Jaquar/Hindware/Equivalent) 15mm dia CP angle stop cock(FLR-ACR-5053N) |
| 121 | 15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make) |
| 122 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 123 | 20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make) |
| 124 | 15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make) |
| 125 | 25mm dia brass full way valve (Shakti make) |
| 126 | 32mm dia brass full way valve (Shakti make) |
| 127 | 40mm dia brass full way valve (Shakti make) |
| 128 | 15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make) |
| 129 | WALL MIXER WITH PROVISION FOR OVERHEAD Shower (FLR-ABR-5273UPR) |
| 130 | 15mm CP Extension piece |
| 131 | 125mm CP grating |
| 132 | 15mm size C.P. flange |
| 133 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge |
| 134 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.(First Floor) |
| 135 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge(First Floor) |
| 136 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in charge.(First Floor) |
| 137 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Supreme /Ashirvad) |
| 138 | 110mm U-PVC P Trap(Ori Plast/Finolex/Supreme Make) |
| 139 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 140 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 141 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 142 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 143 | 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 144 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 145 | 110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make) |
| 146 | 110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) |
| 147 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 148 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge |
| 149 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral p or s trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge |
| 150 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge |
| 151 | Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24 x 18 x 10 sink |
| 152 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 153 | Towel ring |
| 154 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. |
| 155 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. |
| 156 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
| 157 | Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge. |
| 158 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 159 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 160 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge |
| 161 | Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge |
| 162 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 163 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 164 | Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1\\"6\\" in wall including cleaning,applying and mending as per specification including cost,conveyance,taxes,royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge. |
| 165 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge ) |
| 166 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 167 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 6cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge ) |
| 168 | Granite Tiles 10mm Thick (First Floor) |
| 169 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 170 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 171 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 100mm dia P.V.C. pipe |
| 172 | 150mm dia P.V.C. pipe |
| 173 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. |
| 174 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 175 | 1 no 50 users RCC septic tankEarth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge. |
| 176 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 177 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 178 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 179 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 180 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 181 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 182 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 183 | R.C.C beams,columns,girder and bressmer etc. |
| 184 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 185 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 186 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 187 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 188 | Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 189 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
| 190 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 191 | 14,000 ltr capacity R.C.C. Under ground sump of in side size (2.80m x 2.80m x 2.0m)Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 192 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 193 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. |
| 194 | Supplying all materials labour T&P filling sand in foundation and plinth with well watered and rammed etc. all complate. As per direction of ELC. |
| 195 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 196 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 197 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 198 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 199 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 200 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 201 | Construction of 1no production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessoriesLabour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only Drilling of 200mm dia bore, 00 mtr to 30mtr |
| 202 | 30 mtr to 50mtr |
| 203 | Drilling of 150mm dia bore 50 mtr to 210.00mtr |
| 204 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. Lowering of 200mm dia P.V.C casing pipes, 00 mtr to 30 mtrs |
| 205 | 30 mtr to 40mtr |
| 206 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. |
| 207 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 208 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
| 209 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: |
| 210 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) 1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100 standby) |
| 211 | DOL Control panel |
| 212 | 40mm dia steel short piece |
| 213 | Well cap |
| 214 | 50mm size CI bracket |
| 215 | 2.50sqmm flat cable |
| 216 | 20mm dia rigid UPVC pipes |
| 217 | Steel rope with cover |
| 218 | Labour charges for lowering including transportation |
| 219 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge 32mm HDPE pipes (Finolex/Supreme make) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysDec 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender