Tender For Special Repairs To Damaged Wall Paneling, Partition And Other Repairs To Additional Director (M And F) In First Floor Of Cml Building Attached To Directorate Of Public Health And Preventive Medicine In Dms Compound, Teynampet, Chennai-6
Tender Overview
Project Description
Tender for Special Repairs To Damaged Wall Paneling, Partition And Other Repairs To Additional Director (M And F) In First Floor Of Cml Building Attached To Directorate Of Public Health And Preventive Medicine In Dms Compound, Teynampet, Chennai-6
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling the existing old damaged doors and windows including removal of frames hinges and fastenings and clearing and carefully stacking the materials useful for reuse etc complete complying with standard specification and as directed by the departmental officers. |
| 2 | Dismantling the existing old damaged brick masonry under 3m height and carefully stacking the materials useful for reuse etc complete complying with std. Specification and as directed by the dept. officers. |
| 3 | Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c, etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 4 | plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc. |
| 5 | Cement Concrete 1:1-1/2:3 (One Cement, One and a half crushed stone sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including Super Plasticiser, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers - manual mix |
| 6 | For First floor |
| 7 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire). |
| 8 | Renewing and fixing of labour for wrought and put up for frames of doors, windows and ventilators and any other similar joinery works including cost of country wood scantlings and labour charges for manufacturing the frames and fixing hold fasts and fixing in position etc. for all lengths as per architect designs. |
| 9 | Renewing the flush door shutter with new door shutter of C.W of size 0.075x0.025 for screws and nails and fixing with 6mm thick Water proof Plywood on both side and finishing with 1mm thick laminated sheet and finishing the inner and outer alround and preparation with sand papering putty primer etc., complete complying with standard specification and as directed by the departmental officers. (Single leaf) |
| 10 | Renewing the old damaged vertical blinds premium as per the following specification the fabrication 100x150mm colour and white of fabric vanes to have bottom packed the same materials as the vane stablishing weight is to be located in the shutter in plastering moulding to be but in the top side of bottom paacked as all fabric vanes to be sufficiently high quality materials were finished not tray one use in norml all the fabric is opened by rails manufacture from extruded aluminium powder coated in the standard colour rate inclusive of labour charges for fixing etc., complete complying with standard specification and as etc.,complete complying with standard specification and as directed by the departmental officers. |
| 11 | Supply and Installation of 100mm Drywall Partition with four layers of MGO-Magnesia Cement board square edge, Magnesia cement core panels of size 1200x2400x12mm, volume density 1000kgs/m3, weight 12kg/m2 installed by using Auminimum channel.The Aluminimum channel 1.5mm thick,length 3600mm, fixed to the floor and soffit ceiling with suitable fasteners at 300mm staggered centers. Silica noise and fire rated silicon sealant/Matt to be caulked along the lining frame before fixing the Aluminimum channels. Then Aluminimum channel of 25x50x1.5mm thick should be placed into the floor/head channel positioned vertically at 600mm centers. Extra reinforcement to be provided at openings (doors, windows, etc). Synthetic Polyfiber, 1000 gsm density, thickness 50mm, width 600mm is held in position with Stick S7 dab spots in between Aluminimum Channel. Magnesia cement board 1200X2400X12mm is fastened onto the Aluminimum Channel behind in staggered manner using self drilling (drill tip) fasteners at 300mm centers. 4mm gap should be maintained between boards on all sides. Another layer of Magnesia cement board 1200X2400X12mm is fastened onto the first layer of Magnesia Cement board 12mm in staggered manner. 4mm gap should be maintained between boards on all sides. Repeat the process similarly on the other side of the framework to get 100 mm thick partition system. 4mm gap between boards to be filled in full depth by using Jointing Compound as per given recommendations and guidelines. Technical Parameters Fire (Class) – 1 & P, Acoustics - STC 43, Thermal conductivity (W/mk)– 0.118, Climate (°C, RH) – 50, 95, Light reflectance (%) – Paint dependant ,Green (VoC,RC %) – Low, 30 complete and as directed by the departmental engineers. |
| 12 | Fabricating Supplying and fixing in position of Aluminium anodised powder coated finish of single leaf door with half panelled with 1Medium Density Fibre (MDF) Board - Exterior Grade -both sides pre-laminated, 12mm thick at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section Vertical & Top rail: 50x44.45x2.50mm @ 1.292 kg/m ,Bottom rail: 100 x44.45 x 2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/m, Alu Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 Kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - Each., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 1No ., lock-1No., Door stopper with rubber bush including cost of materials labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent |
| 13 | Supplying and painting the walls with One coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work). |
| 14 | Painting Old Plastered Wall Surface with Two finishing coats of ready mixed Interior (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 15 | Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 16 | Collecting the scattered debries from the campus and conveying away the same to outside by lorry to a lead of 3km (Entirely within city limit) including loading and unloading charges and dumping in low places and levelling neatly etc., complete complying with standard specification and as directed by the departmental officers. |
| 17 | GST at 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender