Tender For Electrical Renovation Work To The Auditorium Area Of The Administrative Building At Reserve Bank Staff College, Chennai
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Dec 2026
11 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Renovation Work To The Auditorium Area Of The Administrative Building At Reserve Bank Staff College, Chennai
BOQ
| Sl. No. | Item Description |
| 1 | Lot Description |
| 2 | SITC of Three phase 4-way VTPN UPS power distribution board (UPSDB): Supply, Installation, Testing and Commissioning (SITC) of 4-way double door, factory fabricated, powder coated, metal body, vertical type, three phase (VTPN) electrical distribution board (DB) of approved make with the following as incomer and outgoing MCBs. Works includes wall cutting, chasing, concealing the DB's and taking away all circuit wirings by providing necessary DB knockouts along with required no. of suitable sized, rigid MMS PVC conduits in concealed fashion along with required bends, couplers, connectors & clamps, etc., and refinish the same to match with original wall surface. Work includes re-terminating the disconnected / new incomer cables with clamps and taking away individual outgoing circuits, internal wirings, earth terminations, etc., in a balanced manner. Work also includes providing incomer / outgoing cable and wire terminations using proper sized SS/ brass glands, copper lugs, etc., providing required no. of dummies, etc. Work includes providing suitable sized, closed type PVC / MS boxes (if required / directed) for keeping extra cable / wires and taking away incoming and outgoing circuit wirings, also providing minimum 3 no. of spare / additional one inch rigid MMS empty PVC pipes above / below upto false ceilings / flooring respectively in a concealed manner for future use. All the provided below MCBs shall have to be minimum 10kA short circuit current capacity and C curve type. Incomer : 40 Amps- four pole MCB - 1 no. 40 Amps- four pole ELCB (100 mA)- 1 no.Outgoing : (a) 16 /20/25/32A-Single Pole MCB - 10 no.s; (b) Dummy plate- 2 no.sWork includes proper marking of incoming and outgoing circuits with stickers including cable tagging, etc. This entire work to be executed as directed by the Bank’s Engineer & in coordination with civil engineer and as per architect drawings. |
| 3 | SITC of Three phase 6-way VTPN Main lighting and power distribution board (LPDB): Supply, Installation, Testing and Commissioning (SITC) of 6-way double door, factory fabricated, powder coated, metal body, vertical type, three phase (VTPN) electrical distribution board (DB) of approved make with the following as incomer and outgoing MCBs. Works includes wall cutting, chasing, concealing the DB's and taking away all circuit wirings by providing necessary DB knockouts along with required no. of suitable sized, rigid MMS PVC conduits in concealed fashion along with required bends, couplers, connectors & clamps, etc., and refinish the same to match with original wall surface. Work includes re-terminating the disconnected / new incomer cables with clamps and taking away individual outgoing circuits, internal wirings, earth terminations, etc., in a balanced manner. Work also includes providing incomer / outgoing cable and wire terminations using proper sized SS/ brass glands, copper lugs, etc., providing required no. of dummies, etc. Work includes providing suitable sized, closed type PVC / MS boxes (if required / directed) for keeping extra cable / wires and taking away incoming and outgoing circuit wirings, also providing minimum 3 no. of spare / additional one inch rigid MMS empty PVC pipes above / below upto false ceilings / flooring respectively in a concealed manner for future use. All the provided below MCBs shall have to be minimum 10kA short circuit current capacity and C curve type. Incomer: 40 Amps- four pole MCB - 1 no. 40 Amps- four pole ELCB - 1 no.Outgoing : (a) 25Amps - three pole MCB – 02 no.s (b) O/G -16/20/25/32 Amps-Single Pole MCB - 10 no.s; (c) dummy - 4 no.Work includes proper marking of incoming and outgoing circuits with stickers including cable tagging, etc. This entire work to be executed as directed by the Bank’s Engineer & in coordination with civil engineer and as per architect drawings. |
| 4 | Cable Raceways: Supply and fixing of pre galvanized G.I. based three compartment type inner folded type cables / wire raceway of sizes of 300mm width, 30mm depth, 2mm thickness on the flooring with full length GI top coverings, proper flooring supports, accessories etc. Necessary accessories such as bends, tees, cut provision for junction boxes, wire / cable routings at required places etc. shall be provided and also necessary floor cutting and plastering to original finish all required to complete the work as per site condition and as directed by Bank engineer. |
| 5 | SS based Junction Boxes: supply and fixing of 300mmx300mmx25mm (LxWxD) sized 2.5 mm thick SS make, four way open /required way open type junction boxes to be fixed inline the above GI raceways and on the raised wooden floors/ false flooring / on the original flooring etc. supply includes suitable square base plate to hold the top lid, lid shall have necessary holes/ provision to take out the lid separate from the junction boxes, mouths of the junction boxes shall be compatible with above GI raceways, the Junction boxes lids are latchable, necessary knockouts to be provided to route the power and networking cables etc. The provision and location of the junction boxes shall be as approved and directed by Bank engineers and IT engineers and as per architect drawings. |
| 6 | Supply and Installation of min.32mm diameter rigid PVC conduits (ISI marked) with MMS grade to be laid in concealed manner on wall / partitions/ below floor/ below & above of false floor & false ceiling respectively for power/ IT / CAT-06 cables of computer/ network switches /Audio video systems / PA / TV / WIFI wires etc as indicated in drawings, further in coordination with IT engineer of the college and as directed by Bank engineer. works incl. suitable sized PVC couplers, joints, bends, junction boxes etc and same has to be regularly supported by clip, clamps, supports, nut bolts, etc, works have to be carried out as directed by Bank Engineer & in coordination with IT engineer. |
| 7 | Supply and Installation of min.25mm diameter rigid PVC conduits (ISI marked) with MMS grade to be laid in concealed manner on wall / partitions/ below floor/ below & above of false floor & false ceiling respectively for power/ IT / CAT-06 cables of computer/ network switches /Audio video systems / PA / TV / WIFI wires etc as indicated in drawings, further in coordination with IT engineer of the college and as directed by Bank engineer. works incl. suitable sized PVC couplers, joints, bends, junction boxes etc and same has to be regularly supported by clip, clamps, supports, nut bolts, etc, works have to be carried out as directed by Bank Engineer & in coordination with IT engineer. |
| 8 | UPS power cable: Supply and Laying of 4 core 10 sq.mm copper conductor armoured (Al.) cable, XLPE insulated, FRLS outer sheathed cable, work including termination using accessories such as SS / brass glands, lugs, earth clip, etc. (From Main UPS power PDB located at first floor to sub UPSDB located behind auditorium area of ground floor). Cost of associated civil works such as laying partially in concealed fashion in walls / wooden panels and partially by laying in ceilings/ walls using G.I. special clamps, screws for holding cable etc. work includes cutting / making holes / ways / in ceiling / walls / removal and refixing of wooden wall panels / above the POP or false ceiling (including its cutting & refixing) and refinish to original surface also to be included and work to be carried out as directed by Bank Engineer. |
| 9 | Lighting & power cable: Supply and Laying of 4 core 25 sq.mm Aluminium conductor armoured (Al.) cable, XLPE insulated, FRLS outer sheathed cable, work including termination using accessories such as SS / brass glands, lugs, earth clip, etc. (From Main electric panel located at Auditorium panel room to sub LPDB located behind auditorium area of ground floor). Cost of associated civil works such as laying partially in concealed fashion in walls / wooden panels and partially by laying in ceilings/ walls using G.I. special clamps, screws for holding cable etc. work includes cutting / making holes / ways / in ceiling / walls / removal and refixing of wooden wall panels / above the POP or false ceiling (including its cutting & refixing) and refinish to original surface also to be included and work to be carried out as directed by Bank Engineer. |
| 10 | Supply and laying of 2 runs of 8 SWG copper solid conductors from nearest earth bars / source electric panels to above supplied power distribution boards. |
| 11 | Supply and laying of 2 runs of 12 SWG copper solid conductors from nearest earth bars / source electric panels to above supplied ups power distribution boards. Please Enable Macros to View BoQ information |
| 12 | Supply and laying of 2 runs of 12 SWG copper solid conductors from nearest earth bars / source electric panels to above supplied ups power distribution boards. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysDec 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender