Housing Urban and Rular Development Government Departments Closing in 11 days TDR #58737300

Tender For Electrification & Allied Works Of Examination Hall, Library & Multi Skill Lab At Govt. Degree College, Banbasa, Champawat, Uttarakhand

Issued by Government Departments · Champawat, Uttarakhand
Tender Value
1.24 Crore
Estimated cost
Bid Submission
10 Dec 2026
11 days left
EMD
2.48 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Champawat → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrification & Allied Works Of Examination Hall, Library & Multi Skill Lab At Govt. Degree College, Banbasa, Champawat, Uttarakhand

BOQ

Name of Work:- Electrification & allied works OF EXAMINATION HALL, LIBRARY & MULTI SKILL LAB AT GOVT. DEGREE COLLEGE, BANBASA, CHAMPAWAT, UTTARAKHAND
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
2Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
3Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required.
4Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
5Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Circuit Wiring & Light Plug Wiring)
62 XWiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 6 sq. mm + 1 X 6 sq. mm (For Single Phase DB. From Sub Panel to DB)
7Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 6 sq. mm + 2 X 6 sq. mm (For Three Phase DB. From Sub Panel to DB)
8Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm (For Three Phase DB. From Sub Panel to DB)
9Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 16 sq. mm (For Three Phase DB. From Sub Panel to DB)
10Supplying and fixing following Modular base & cover plate one existing modular metal boxes etc. as required 6 Module
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required5/6 A switch
12Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required3 pin 5/6 A socket outlet
13Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 15/16 A Switch
14Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 6 pin 15/16 A Socket outlet
15Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
16Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
17Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
18Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
19Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
20Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
21Supplying and fixing brass batten/ angle holder including connection etc. as required.
22Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
23Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
24Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
25Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
26Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, Unarmored Telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
27Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
28Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable
29Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
30Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
31Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
32Extra for Fixing the Louvers/ Shutters Complete with Frame for a Exhaust Fan of all sizes.
33Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
34Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
35Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredSingle pole
36Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
37Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
38Supplying and Fixing Following way, Horizontal Type Three Pole and Neutral, Sheet Steel, MCB Distribution Board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 Way (4 + 18), Double Door
39Supplying and Fixing Following way, Horizontal Type Three Pole and Neutral, Sheet Steel, MCB Distribution Board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 Way (4 + 24), Double Door
40Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
41Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
42Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
43Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 25 A
44Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 40 A
45Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
46Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 95 sq. mm (38mm)
47Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness
48150 mm width X 50 mm depth X 1.6 mm thickness
49225 mm width X 50 mm depth X 1.6 mm thickness
50450 mm width X 50 mm depth X 2.0 mm thickness
51Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness
52150 mm width X 50 mm depth X 1.6 mm thickness
53225 mm width X 50 mm depth X 1.6 mm thickness
54450 mm width X 50 mm depth X 2.0 mm thickness
55Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness
56150 mm width X 50 mm depth X 1.6 mm thickness
57225 mm width X 50 mm depth X 1.6 mm thickness
58450 mm width X 50 mm depth X 2.0 mm thickness
59Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Cross member\\"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
60150 mm width X 50 mm depth X 1.6 mm thickness
61225 mm width X 50 mm depth X 1.6 mm thickness
62450 mm width X 50 mm depth X 2.0 mm thickness
63Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Reducer\\" (galvanisation not less than 50 microns) with perforation not more than17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
64150 mm width X 50 mm depth X 1.6 mm thickness
65225 mm width X 50 mm depth X 1.6 mm thickness
66450 mm width X 50 mm depth X 2.0 mm thickness
67SITC of Main LT panel Incomer 1 No. 400 amps 4P MCCB (35KA), 01 nos 125 Amp Incoming from Solar plant with 250 Amp Changeover switch , with Thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. Metering & Indication foreach Incomer 1 set of R,Y,B phase indicating lamps 1 set of On/Off phase indicating lamps Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port. Sets of 125/1A, CL-1, 15VA CTs for measuring. Busbar 160A TP+100%Neutral Aluminium Bus Bar with colour coded PVC Sleeves Outgoings, 5 No. 150 amps FP MCCB 10KA C Curve 5 No. 63 amps FP MCCB 10KA C Curve, 5 No. 40amps DP MCB 10KA C Curve 3 No. 100amps FP MCCB 10KA C Curve Complete in all respect.
68FLOORS PANELDesign, manufacture, supply, installation, testing and commissioning of Floor Mounting Distribution Panel cubicle type panel fabricated out of CRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ complete with aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid. INCOMER : 150 AMP BUS BAR : 150 AMP, 440 Volts, 3 phase 50 HZ 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm/amp.The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient Temperature. OUT GOINGS : 1 No 40 AMP 4P MCB (Light DB 1), 1 No 40 AMP 4P MCB (Light DB 2) 1 No 63 AMP 4P MCB (Power DB 1) 1 No 63 AMP 4P MCB (Power DB 2) 4 No 63 AMP 4P MCB (Spare) Complete panel as above and complete
69Providing and Supplying of LED Batten 20 Watts 1150 mm
70Providing and Supplying of 9W Led Bulb With Battery-Is:16102, Warranty for free replacement 1 year
71Providing and Supplying of 12W Warm White Ceramic Circular LED Surface Ceiling Light
72Providing and Supplying of Aluminium Wall Fan 2 year Warranty
73Providing and Supplying of Exhaust Fan 300 mm
74Providing & Supplying Extinguisher Fire Carbondioxide 4.5 kg,duly charged, Portable and complete as per defence specification
75Providing & Supplying ceasefire Wall Mounted Automatic Fire Extinguisher Powder Based (as per IS 4308 ) Automatic
76Providing & Supplying FIREMAN'S AXE 3 kg (Fire suppression hand tools)
77Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
78Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
79Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
80Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
81Supply of 30KVA/ 30KW True Online , DSP Controlled , double conversion online UPS with 3 phase AC input and 3 phase AC output with 30min backup on 12V SMF batteries Bank with Rack ( min. VAH required =24960 VAH ) ,The UPS should be with IGBT Based Rectifier and IGBT based Inverter and with LCD/LED display for monitoring of its status along with same OEM Make inbuilt Galvanic Isolation Transformer . UPS should have inbuilt phase sequence corrector and dust filters,SNMP Card & parallel kit.True Online Double Conversion with IGBT Based Rectifier & IGBT Based Inverter Technology with conformal coated PCB board.Input Voltage window 320 VAC - 475 VAC Input Frequency window 45-55 HzNominal Frequency 50 Hz Total Harmonic Current Distortion (THDI ) should be less than 5 % at full rated load Input power factor (pf) greater than or equal to 0.99 Bypass Frequency range (+/- 10%) Output Power Factor should be Unity. Output Power Capacity in watts (KW) 30KVA / 30KW Output Voltage - 400 /415 Volts rms, adjustable via the user interface. Total Harmonic Distortion : < 2% for linear load & <5% for 100% non-linear load Output Frequency range 50/60 HZ. Minimum 94% without isolation 60 minutes at a load representing 110 % , 10 minutes at a load representing 125% , 60 second at a load representing 150% Parallel option upto 4 Units should be available UPS Should Be built in Manual and Maintenance Bypass One Year on UPS Two years on UPS with onsite service Support 40 degree C Less than 70 dBA Min. VAH for bank required =24960 VAH.Battery Type DC Voltage Bus ( 384-480) VDC . UPS Should Work Flexible on 384 - 480 batteries. Common battery bank configuration is require upto 2 UPS. RS232 , USB /optional SNMP, over volatage,short circuit ,overload at UPS O/p and Under Voltage at battery terminal ISO 9001 & 14001 certification,IEC 62040-1,62040-2,62040-3 & PEP is require. UPS should be with microprocessoe based LCD Display OEM service centre in Dehradun & Haldwani. omplete in all respect.
82Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25mm
83Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed Steel/PVC conduit as required 1 run of cable.
84Supplying and fixing of GI box of following size modules, along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmx75mm)
85Supply, installation, testing and commissioning of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. RJ 45 Socket
86Supply, installation, testing and commissioning of 9U rack complete with all accessories etc complete as per specifications and as required.
87Supply, installation, testing and commissioning of 42U rack complete with all accessories etc complete as per specifications and as required.
88Supply, installation, testing and commissioning of 12 port unmanaged ethernet switch.
89Supply, installation, testing and commissioning of 24 port managed ethernet switch with 2 nos fiber ports.
90Supply, installation, testing and commissioning of Cat-6 shuttered 12 port fully loaded patch panel.
91Supply, installation, testing and commissioning of 24 port Patch panel fully loaded patch panel. Cat-6 UTP
92Supply, installation, testing and commissioning of Cat-6 UTP 24AWG patch cord, 1 meter, Plug 30U, snaglless etc as required.
93Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the in case of recessed conduit as required.
94Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed Steel/PVC conduit as required. 1 run of cable
95Supply, installation, testing and commissioning of IP CAMERA INDOOR 4MP with RJ 45 connector/jack.
96Supply, installation, testing and commissioning of IP CAMERA OUTDOOR 4MP with RJ 46 connector/jack.
97Supply, installation, testing and commissioning of NVR 32 channel complete with all respect accessories and suitable for minimum 4 slot harddisk.
98Supply, installation, testing and commissioning of hard disc 4TB per NVR
99Supply, installation, testing and commissioning of SWITCH 16 port POE
100Supply, installation, testing and commissioning of SWITCH 24 port POE
101Supply, installation, testing and commissioning of Back Box.
102Supply, installation, testing and commissioning of 48\\" LED screen for Observation and reviewing
103Supply and fixing of 2 meter patch cord with complete connectors
104Supply, installation, testing and commissioning of 42U RACK with PDU and respected accessories.
105Supply, installation, testing and commissioning of 9U RACK with PDU and respected accessories.
106Supplying, installation, testing and commissioning of grid interactive roof top solar photo volraic power generation system including space frame Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58737300
AUTHORITY Government Departments
TENDER VALUE 1.24 Crore
LAST DATE 10-12-2026
Authority
Authority Name Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited
Work Description Tender for Electrification & Allied Works Of Examination Hall, Library & Multi Skill Lab At Govt. Degree College, Banbasa, Champawat, Uttarakhand
Basic Detail
Tender No 1762/BRIDCUL/1097/26 Dated 17.11.2026
Bidding Type Tender
Location
City Champawat
State Uttarakhand
Key Dates
Publish Date 26 Nov 2026
Submission Date 10 Dec 2026
Open Date 10 Dec 2026
Finance
Tender Value 1.24 Crore
Tender Fee 5900
EMD 2.48 Lakhs
Exemption Not Available
Document List
4e8908b7-6a5f-4e3f-ad78-6fdf7659f89d.html
BOQ_121162.xls
sbdelecricalmultiskilllib_1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Dec 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

4e8908b7-6a5f-4e3f-ad78-6fdf7659f89d.html

xls

BOQ_121162.xls

pdf

sbdelecricalmultiskilllib_1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender