Tender For Leakage Repairing Work Of W/S Rising Main, Service Main, Replacement And Repairing Of Old And Damaged Air Release Vlave, S/V And Related Work At D.H. Road, Daimond Park, B.H. Road, Patra Para, Etc. In Ward No. 144, Br-Xvi.
Tender Overview
Project Description
Tender for Leakage Repairing Work Of W/S Rising Main, Service Main, Replacement And Repairing Of Old And Damaged Air Release Vlave, S/V And Related Work At D.H. Road, Daimond Park, B.H. Road, Patra Para, Etc. In Ward No. 144, Br-Xvi.
BOQ
| Sl. No. | Item Description |
| 1 | CHAPTER - VIII SUPPLYING OF MATERIALS 8.12 Cast iron kinetic double orifice type air release valve having small orifice elastic ball resting on gun metal orifice nipple large orifice vulcanite ball seating on moduled seat ring, valve with built-in-Kinetic features, isolating sluice valve mounted in horizontal position and operated by a metre wheel gearing:inlet faced and drilled to IS 1538 Table 4 & 6. valve suitable for maximum working pressure of 10 kg/CM2 Diameter in mm 80 |
| 2 | BUILDING WORKS (A) EARTH WORK,ANTITERMITE TREATMENT 2. Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. |
| 3 | BUILDING WORKS (A) EARTH WORK,ANTITERMITE TREATMENT 3. Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation. |
| 4 | CHAPTER - I [ SUPPLEMENTARY ] EXCAVATION, SHORING, BAMBOO PILING, FENCING & SIGN BOARD, LIGHTING & SIGNALING AND SITE CLEANING ETC. 1.14 Signalling arrangement at both sides of site to avoid any accident during working period 4 nos. red flags during sunlight at 4 corners and 2 nos light (lamp) in other than sunlight. |
| 5 | CHAPTER - I [ SUPPLEMENTARY ] EXCAVATION, SHORING, BAMBOO PILING, FENCING & SIGN BOARD, LIGHTING & SIGNALING AND SITE CLEANING ETC. 1.13 Hire & labour charges for diesel generating set for lighting including fuel,300M wire, 11 points with 200 Watt bulb with post for hanging & maintaining the same for day & night for the period. |
| 6 | SECTION(B) - SANITARY AND DRAINAGE WORKS.(B)-(II) SOIL PIPE AND FITTINGS.(a) Original Works.(23)Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992.(A)(i) Single Socketed 3 Metre Length.(b) 110 mm. |
| 7 | D.I SPUN PIPE 100MM (4\\") (TYTON JOINT) CONFIRMING TO IS:8329/2000 CLASS K-7 SUITABLE FOR PUSH ON JOINT (RUBBER GASKET JOINTING) WITH INSIDE CEMENT MORTAR LINING AND OUTSIDE BITUMINOUS/SYNTHETIC RESIN COATING COMPATIBLE WITH THE METALLIC ZINC COATING AS PER CLAUSE A-8 |
| 8 | CHAPTER - I [ SUPPLEMENTARY ] EXCAVATION, SHORING, BAMBOO PILING, FENCING & SIGN BOARD, LIGHTING & SIGNALING AND SITE CLEANING ETC. 1.5 Cutting & picking up existing metalled black top portion of road surface to an average depth of 300 mm by using Jack hammer with all necessary tool and plant including reening the serviceable materials & stacking within a lead of 75 mtr. all complete as per direction of the Engineer-in- Charge. |
| 9 | SECTION(B) - SANITARY AND DRAINAGE WORKS.(B)-(II) SOIL PIPE AND FITTINGS.(a) Original Works.(23)Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992.(B) Fittings.ix) Bend 45....(b) 110 mm |
| 10 | SECTION(B) - SANITARY AND DRAINAGE WORKS.(B)-(II) SOIL PIPE AND FITTINGS.(a) Original Works.(23)Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992.(B) Fittings.x) Bend 87.5....(b) 110 mm |
| 11 | BUILDING WORKS (B) DISMANTLING, CUTTING CHASE, HOLES ETC 2. Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m In ground floor including roof. (a) upto 150 mm. thick |
| 12 | CHAPTER - VII MISCELLANEOUS ITEMS Supplying, fitting and fixing of C.I. Mechanical Compression flexible Collar Couplings suitable for C.I. Spun Pipes (as per IS: 1536) and D. I. Pipes (as per IS: 8329) complete with Sealing Rubber Gasket of EPDM quality (IS:5382/1985 Type - 4), Cast Iron Follower Glands and Mild Steel Nut Bolts (Zinc Coated). The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS: 1538. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. Diameter in mm 200 |
| 13 | CHAPTER - II LAYING & JOINTING PIPES, SPECIALS ETC.2.1 C.I. / D.I. Pipe & Specials 2.1 C.I. / D.I. Pipe & Specials 2.1.7 Cutting of C.l/D.I pipes for fitting with pipes and-or specials of similar or dissimilar materials at the time of laying without damaging any part of the required length including taking out of the broken pieces from the trench and restacking the same at the specified location as per direction of the Engineer-in-Charge.D iameter in mm 100mm dia. |
| 14 | CHAPTER - II LAYING & JOINTING PIPES, SPECIALS ETC.2.1 C.I. / D.I. Pipe & Specials 2.1 C.I. / D.I. Pipe & Specials 2.1.8 Chamfering the spigot end of C.l./D,l. pipes for fitting with the socket of C.I./D.I pipes and/or specials in tyton jointed water mains or other wise using electric grinder as per specification and direction of the Engineer-in-Charge. Diameter in mm 100mm dia. |
| 15 | PLUMBING WORKS (A)-(I) FERRULE AND FERRULE CONNECTION (b) REPAIR WORKS 3. Dismantling existing ferrule with fittings and refixing same after cleaning. |
| 16 | (C) III: Labour Rate for Sanitary and Plumbing 4.Methor Mazdoor NOTE:The above rates are exclusive of 10 % profit and 1% Labour welfare cess, which would be admissible to the Contractor, but contractual percentage will not be applicable on the above rates.Page 113 of 124 |
| 17 | CHAPTER - I [ SUPPLEMENTARY ] EXCAVATION, SHORING, BAMBOO PILING, FENCING & SIGN BOARD, LIGHTING & SIGNALING AND SITE CLEANING ETC. 1.10 Hire and labour charges for coir rope fencing 25 mm dia rope single on 120 mm dia bamboo posts 1.40 m above G.L and 600 mm below G.L, 1.50 m apart including digging holes complete. |
| 18 | CHAPTER - VII MISCELLANEOUS ITEMS Supplying, fitting and fixing of C.I. Mechanical Compression flexible Collar Couplings suitable for C.I. Spun Pipes (as per IS: 1536) and D. I. Pipes (as per IS: 8329) complete with Sealing Rubber Gasket of EPDM quality (IS:5382/1985 Type - 4), Cast Iron Follower Glands and Mild Steel Nut Bolts (Zinc Coated). The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS: 1538. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. Diameter in mm 100 |
| 19 | SECTION(B) - SANITARY AND DRAINAGE WORKS.(B)-(II) SOIL PIPE AND FITTINGS.(a) Original Works.(23)Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992.(B) Fittings.(ii) Plain Tee.(c) 16.0 mm |
| 20 | PLUMBING WORKS (A)-(II) G.I. PIPE WORKS AND FITTINGS 2. Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately) (ii) 20 mm dia. medium quality |
| 21 | CHAPTER - VII MISCELLANEOUS ITEMS Dewatering by pumps including all leads, lifts and making all arrangements of disposal. where continuous flow of water from a source other than natural or ground water is encountered in case of emergency maintenance works related to leakage. breakage and making wet connections. [Note ;- In case of any other situation demanding such emergency dewatering. use of this item is to be approved by the Superintending Engineer/Tender Accepting Authority. This item shall be executed on the specific direction duly supported by proper clarification of the E.I.C. who will be satisfied in absolute discretion that such work has not been necessitated due to any natural source of water or any fault of the Contractor] |
| 22 | CHAPTER - I [ SUPPLEMENTARY ] EXCAVATION, SHORING, BAMBOO PILING, FENCING & SIGN BOARD, LIGHTING & SIGNALING AND SITE CLEANING ETC. 1.4 Excavation of trial pit (3.0 m x 1.0 m x (upto) 3.0 m) for fixing of pumping main, washout line raking every detection against damage of S.W. pipe line electrical cable etc. as underground obstruction including 37.5 mm timber shuttering, earth cutting, dewatering, barricading and back filling etc. as per directionj of E-I-C |
| 23 | CHAPTER - VIII SUPPLYING OF MATERIALS 8.3 All types of Ductile Iron (D.I) Specials (viz. Bend. Tee. Taper. Tail piece etc), size conforming to I.S. Specification No. 9523/2000 with cement mortar lining (inside) and bituminous coating (outside). (25% of payment will be held up till successful hydraulic testing) a) All Socket Tee 100 mm to 300mm dia. |
| 24 | CHAPTER - VIII SUPPLYING OF MATERIALS 8.3 All types of Ductile Iron (D.I) Specials (viz. Bend. Tee. Taper. Tail piece etc), size conforming to I.S. Specification No. 9523/2000 with cement mortar lining (inside) and bituminous coating (outside). (25% of payment will be held up till successful hydraulic testing) b) Doubled Socketed Bend 100 mm to 300mm dia |
| 25 | CHAPTER - VIII SUPPLYING OF MATERIALS 8.6Cost iron double flanged manually operated sluice valves generally conforming to IS 14846 : 2000, having four faces and spindle nut of gunmetal. inside screw non- rising type quality gunmetal /AISI 410 spindle: seat tested to 10kg/CM... and body tested to 15kg/CM..., flanges flat faced and drilled to 1.S.: 1538 : 1993. Painted black all over with asphalt base paint. Valves tested by closed end method. NB Diameter in mm 150 |
| 26 | CHAPTER - II LAYING & JOINTING PIPES, SPECIALS ETC.2.1 C.I. / D.I. Pipe & Specials 2.1 C.I. / D.I. Pipe & Specials 2.4Valves 2.4.1 Lowering, fitting and fixing of all types of valves in proper position and alignment using chain pully block or crane(for diameter above 250 mm) by providing temporary support,as required,gaskets,nuts& bolts etc.all cornplete as per specification and direction of the Engineer-in-Charge.[The rate Includes cost of flange joints]150mm dia. |
| 27 | CHAPTER - VII MISCELLANEOUS ITEMS Supplying, fitting and fixing of C.I. Mechanical Compression Split Collars suitable for instantaneous repair of longitudinal and vertical splits in C.I. Spun Pipes (as per IS: 1536) and D.I. Pipes (as per IS: 8329) by encasing the damaged part completely. The Split Collars to be supplied complete with Sealing Rubber Gasket of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel Nut Bolts (Zinc Coated). The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS: 1538. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition.Diameter in mm. with minimum barrel pipe length in mm. 150mm with length 300mm. |
| 28 | CHAPTER - VII MISCELLANEOUS ITEMS Supplying, fitting and fixing of C.I. Mechanical Compression Transition Collar Couplings suitable for jointing C.I. Spun Pipes (as per IS: 1536) and D.I. Pipes (as per IS: 8329) with corresponding Inch size Pipes (as per Class-B of BS: 1211). The Couplings to be supplied complete with Sealing Rubber Gasket of EPDM quality (IS:5382/1985 Type-4), Cast Iron Follower Glands and Mild Steel Nut Bolts. The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS: 1538. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. Diameter in mm x inch. with minimum barrel length in mm. 350mm x 14 inch. with length 150mm |
| 29 | CHAPTER - II LAYING & JOINTING PIPES, SPECIALS ETC.2.1 C.I. / D.I. Pipe & Specials 2.1 C.I. / D.I. Pipe & Specials 2.1.7 Cutting of C.l/D.I pipes for fitting with pipes and-or specials of similar or dissimilar materials at the time of laying without damaging any part of the required length including taking out of the broken pieces from the trench and restacking the same at the specified location as per direction of the Engineer-in-Charge.D iameter in mm 400mm dia. |
| 30 | CHAPTER - II LAYING & JOINTING PIPES, SPECIALS ETC.2.1 C.I. / D.I. Pipe & Specials 2.1 C.I. / D.I. Pipe & Specials 2.1.8 Chamfering the spigot end of C.l./D,l. pipes for fitting with the socket of C.I./D.I pipes and/or specials in tyton jointed water mains or other wise using electric grinder as per specification and direction of the Engineer-in-Charge.Diameter in mm 350mm dia. |
| 31 | CHAPTER - VII MISCELLANEOUS ITEMS Repair of Air valve by supplying ebonite and- rubber ball. gasket. nuts and bolts with washers and labour all complete Diameter in mm 100 |
| 32 | CHAPTER - VII MISCELLANEOUS ITEMS Supplying, fitting and fixing of C.I. Mechanical Compression flexible Collar Couplings suitable for Inch size C.I. Pipes conforming to Class-B of BS: 1211 complete with Sealing Rubber Gasket of EPDM quality (IS:5382/1985 Type- 4), Cast Iron Follower Glands and Mild Steel Nut Bolts (Zinc Coated). The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS: 1538. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. Diameter in inch. with minimum barrel length in mm. 18 inch with length 150mm |
| 33 | CHAPTER - III TAKING OUT PIPES AND SPECIALS Cast Iron / Ductile Iron Pipes and Specials M.S. Pipes and Specials Shifting house connection or stand post connection from existing main to new main after excavation through any kind of soil and road materials up to required depth. dismantling existing ferrule with all fittings. plugging hole of old main with G.I. plug. drilling and tapping the new main. refixing the ferrule on the new main with serviceable old G.I pipes and other specials (New G.l. pipes and other specials. if required to be installed shall be paid extra) and back filling the trench with excavated materials all complete as per specification and direction of the Engineer- in-Charge. |
| 34 | D.I SPUN PIPE 150MM (6\\") (TYTON JOINT) CONFIRMING TO IS:8329/2000 CLASS K-7 SUITABLE FOR PUSH ON JOINT (RUBBER GASKET JOINTING) WITH INSIDE CEMENT MORTAR LINING AND OUTSIDE BITUMINOUS/SYNTHETIC RESIN COATING COMPATIBLE WITH THE METALLIC ZINC COATING AS PER CLAUSE A-8 |
| 35 | Sub Total |
| 36 | GST 18% |
| 37 | CESS 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender