Power Government Departments Closing in 7 days TDR #58736670

Tender For Nabard-Ridf Tranche Xxxi- Infrastructure Development Of Various Offices Under Northern Circle, Kannur-Construction Of Forest Complex (Hostel Facility) At Kalpetta In Kalpetta Range, Wayanad District

Issued by Government Departments · Ernakulam, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Dec 2026
7 days left
EMD
50000
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Nabard-Ridf Tranche Xxxi- Infrastructure Development Of Various Offices Under Northern Circle, Kannur-Construction Of Forest Complex (Hostel Facility) At Kalpetta In Kalpetta Range, Wayanad District

BOQ

Name of Work:- NABARD-RIDF TRANCHE XXXI- Infrastructure Development of Various offices under Northern Circle, Kannur-Construction of Forest Complex (Hostel Facility) at Kalpetta in Kalpetta Range, Wayanad District
Sl. No. Item Description
1Civil Works
22.31Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees andsaplings of girth up to 30 cm measured at a height of 1 m above ground level andremoval of rubbish up to a distance of 50 m outside the periphery of the area cleared
32.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil
42.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil
516.78.1Construction of granular sub- base by Providing close graded Material conforming tospecifications, mixing in a mechanical mix plant at OMC, Carriage of mixed materialby tippers to work site, for all leads & lifts, spreading in uniform layers of specifiedthickness with motor grader on prepared surface and compacting with vibratorypower roller to achieve the desired density, complete as per specifications anddirections of Engineer-in- Charge.With Material conforming to Grade - I ( size range75 mm to 0.075 mm) having CBR Value- 30
64.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources)
74.1.6Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3coarse sand (zone-III) derived from natural sources : 6 gradedstone aggregate 40 mm nominal size derived from natural sources)
85.33.1.1Providing and laying in position ready mixed or site batched design mix cementconcrete for reinforced cement concrete work; using coarse aggregate and fineaggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 toaccelerate / retard setting of concrete, to improve durability and workability withoutimpairing strength; including pumping of concrete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishing andreinforcement as per direction of the engineer-in-charge; for the following grades ofconcrete. Note: Extra cement up to 10% of the minimum specified cement content indesign mix shall be payable separately. In case the cement content in design mix ismore than 110% of the specified minimum cement content, the contractor shall havediscretion to either re-design the mix or bear the cost of extra cementAll work upto plinth levelConcrete of M25 grade with minimum cement content of330 kg /cum
95.33.2.1Providing and laying in position ready mixed or site batched design mix cementconcrete for reinforced cement concrete work; using coarse aggregate and fineaggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 toaccelerate / retard setting of concrete, to improve durability and workability withoutimpairing strength; including pumping of concrete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishing andreinforcement as per direction of the engineer-in-charge; for the following grades ofconcrete. Note: Extra cement up to 10% of the minimum specified cement content indesign mix shall be payable separately. In case the cement content in design mix ismore than 110% of the specified minimum cement content, the contractor shall havediscretion to either re-design the mix or bear the cost of extra cementAll work above plinth level upto floor V levelConcrete of M25 grade with minimumcement content of 330 kg /cum
104.2.5Providing and laying cement concrete in retaining walls, return walls, walls ( anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks,plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the costof centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 gradedstone aggregate 20 mm nominal size derived from natural sources)
114.1.3Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarsesand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mmnominal size derived from natural sources)
1260.6PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes workingpressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc.complete.
135.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
144.3.2Centering and shuttering including strutting, propping etc. and removal of form workfor:Retaining walls, return walls, (any thickness) including attached pilasters,buttresses, plinth and string courses fillets, kerbs and steps etc.
155.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts
165.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers
175.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform
185.9.16.1Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
195.9.19Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges
205.9.7Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases)
215.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
227.1.1Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand)
232.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2450.6.1.4Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 part I of 1979 for foundation andplinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etccomplete
2550.6.1.5Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 Part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etccomplete
2650.6.1.6Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 part I of 1979 for super structureabove floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1cement : 6 coarse sand sand) etc complete
27OD154971/2026-2027 Providing and fixing pressed steel door frame and pressed GI steel door shutter,including frame members, shutter profiles, inner sheet, stiffeners and powder coating finish, as perdetailed specifications:Structural steel such as tees, angles, channels and R.S.joists (Base tie 25x5mm MSflat 1kg/M, QTY including 5% wastage: 1 mx 1 kg/m x 1.05 = 1.05 kg. Door frame Structuralsteel such as tees, channels and R. S. joists. Hinges fixing plate mortar guards, hold fasts etc 3.2kg. Assembly and setting charges of frame and door with protective packing. Outerstiffeners 12x8cm GI 18G 4Nos -7.5kg embossed inner sheet using Gl Sheet 20G . Door shuttersection B 75x30mm @1.70kg/m using GI 18G . Qty including 5% wastage. SS butt HINGES125X2.5mm with fixing screws 4nos/door , Section A 105X60 @ 2.16 kg/m using GI sheet18G quantity including 5% wastage. Thickness of door - 30mm
2813.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
2913.16.16 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
3022.5Providing and laying water proofing treatment in sunken portion of WCs, bathroometc., by applying cement slurry mixed with water proofing cement compoundconsisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed withwater proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to aircure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed withwater proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to aircure for 4 hours followed with water curing for 48 hours. The rate includespreparation of surface, treatment and sealing of all joints, corners, junctions of pipesand masonry with polymer mixed slurry.
3111.41A.3.2 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 1200 mm
32OD201911/2026-2027Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 1200x600 mm
338.2.2.2 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, faciasand similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels.Area of slab over 0.50 sqm
3411.56.1Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slabcolour of Black, Cherry/Ruby Red or equivalent
358.3.2Providing edge moulding to 18 mm thick marble stone counters, vanities etc.,including machine polishing to edge to give high gloss finish etc. complete as perdesign approved by Engineer -in-Charge.Granite work
3611.20.3Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard,jointed with neat cement slurry mixed with pigment to match the shade of tiles,including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement
379.119Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wallthickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred atcorners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. squaretube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. squaretube of 19 gauge, EPDM rubber gasket weather seal to be provided through out theframe. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size,complete as per manufacturer's specification and direction of Engineer-inCharge.
389.120.1Providing and fixing factory made panel PVC door shutter consisting of frame madeout of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primersof approved make and manufacture. M.S. frame covered with 5 mm thick heatmoulded PVC 'C' channel of size 30 mm thickness, 70 mm width out ofwhicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall betapered in 45 degree on th inner side to form top and bottom rail and 115 mm widePVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on bothsides to form lock rail. Top, bottom and lock rails shall be provided both side of thepanel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insertfor top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to befitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm +2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined togetherwith solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width isto be stuck on the interior side of the 'C' Channel using PVC solventadhesive etc. complete as per direction of Engineer -in-charge, manufacture'sspecification & drawing.30 mm thick plain PVC door shutters
39OD154976/2026-2027(OD-9.147D.3 + Glazing) )Providing and fixing factory made uPVC white coloursliding glazedwindow upto 1.50 m in height dimension comprising of uPVC multi-chamberedframe with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mmthick galvanized mild steel section made from roll forming process of required length(shape & size according to uPVC profile), appropriate dimension of uPVC extrudedglazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy(white powder coated) touch locks withhook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg),G.Ifasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainlesssteel screwsetc. Profile of frame & sash shall be mitred cut and fusion welded at all corners,includingdrilling of holes for fixing hardware's and drainage of water etc. After fixing framethe gapbetween frame and adjacent finished wall shall be filled with weather proof siliconsealent overbacker rod of required size and of approved quality, all complete as per approveddrawing &direction of Engineer-in-Charge. Note: For uPVC frame and sash extruded profilesminus 5%tolerance in dimension i.e. in depth & width of profile shall be acceptable. Two tracktwo panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / doubleglazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50sqm).
4010.25.2Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works
4110.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.)
4213.80Providing and applying white cement based putty of average thickness 1 mm, ofapproved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete.
4313.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer
4413.46.1Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm)
4513.60.1Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work
4613.61.1Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work
4722.6Providing and laying water proofing treatment on roofs of slabs by applying cementslurry mixed with water proofing cement compound consisting of applying : a) aftersurface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with waterproofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be lessthan 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarsesand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by watercuring for 48 hours. The entire treatment will be taken upto 30 cm on parapet walland tucked into groove in parapet all around. d) fourth and final layer of brick tillingwith cement mortar (which will be paid for separately. For the purpose ofmeasurement the entire treated surface will be measured)
4816.91.1Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.60mm thick cementconcrete paver block of M-35 grade with approved colour, design & pattern.
4917.81Providing and fixing floor mounted, white vitreous china single piece, double trapssyphonic water closet of approved brand/make, shape, size and pattern includingintegrated white vitreous china cistern of capacity 10 litres with dual flushing system,including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts andgasket etc including making connection with the existing P/S trap, complete in allrespect as per directions of Engineer-in-Charge.
5050.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge.
5118.51.1Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore
5217.10.2.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983with C.I. brackets and stainless steel plug 40 mm, including painting of fittings andbrackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm
5317.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Washbasin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
5418.65Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102mm, height of 75 mm with concealed fittings arrangements, weighing not less than106 gms.
5517.73.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour450 mm long towel rail with total length of 495 mm, 78 mm wide and effectiveheight of 88 mm. weighing not less than 170 gms
5618.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore
5750.18.8.8.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
5850.18.8.9.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
5950.18.9.18.1Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 mspacing. This included jointing of pipes with one step PVC solvent cement and testingof joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 External work- Exposed on wall
6050.18.9.9.1Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction ofengineer in charge.110 mm dia 6Kgf/cm2
6150.18.9.16.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall
6250.18.9.17.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 mspacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 63 mm dia 6Kgf/cm2 - External work - Exposed on wall
6350.18.9.18.2Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 mspacing. This included jointing of pipes with one step PVC solvent cement and testingof joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 External work - Exposed on wall
6450.18.9.3.2Providing and fixing PVC pipes includes jointing of pipes with one step PVC solventcement, trenching, refilling & testing of joints complete as per direction of Engineerin Charge. 25 mm dia 10KGF/cm2
6550.18.9.4.2Providing and fixing PVC pipes includings joints of pipes with one step PVC solventcement, trenching, refilling & testing of joints complete as per direction of Engineerin Charge. 32 mm dia 6 Kgf/cm2
6650.18.9.22.3Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement-110 mm dia Door Elbow
6750.18.9.22.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend
6850.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee
6950.18.9.22.8 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110 mm dia Vent cowl
7018.58.1.1Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia
7118.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank.
7218.32.1Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm(inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation,foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mmnominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cementcomplete as per standard design:With common burnt clay F.P.S (non modular) bricksof class designation 7.5
73Electrification Works
741.10.1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
751.10.2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B
761.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
771.11Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copperconductor single core cable in surface / recessed medium class PVC conduit, 2 waymodular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
781.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group C
791.19Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copperconductor PE insulated, shielded with fine tinned copper braid and protected withPVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
801.24.7Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.TV antenna socket outlet
811.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm
821.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm
831.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch
841.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch
851.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet
861.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.6 pin 15/16 amp socket outlet
871.24.8Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.Bell push
881.27.1Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.1 or 2 Module(75mmX75mm)
891.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
901.27.3Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
911.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
921.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required.
931.34Supplying and fixing brass batten/ angle holder including connection etc. as required
9490.4.5.4Supply, Installation, testing and commissioning of ceiling fan of following sizesincluding wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mmFRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper windingsuitable for 230V/240V single phase AC supply
95OD223695/2026-2027SITC of 450mm sweep wall fan having speed control, oscillation control at bottom assuitable for operation on single phase 230 volt AC supply complete with continuousduty motor and all accessories including mounting as required for completeinstallation.
96OD208312/2026-2027Supply and installation of 1200mm, 20W LED tube light with all accessories asrequired.(Make: Crompton/Philips/Wipro)
9790.15.4.2Supply Conveyance, installation, testing and commissioning of 36/40W LED streetlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coatedhousing,acrylic cover complete with THD less than 10%, power factor greater than0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Drivercompartment should be seperatly accessible for maintenance (LM 79&80certificates from NABL accredited Third party lab to be produced mentioning chipmanufacturer)
98OD223699/2026-2027Supplying and fixing of required length 32 mm dia G.I. Pipe (light class) includingpainting etc. as required
99OD208313/2026-2027 Supply, Conveyance, installation , testing and commissioning of 200 mm sweep LightDutyExhaust fan in plastic body with self opening lowers in the existing opening, fixingnecessaryanchor bolts / bolt and nuts etc., as required including giving connections with thesupplied wirealong with the exhaust fan
100OD208314/2026-2027Supply, conveyance, installation , testing and commissioning of 300/305 mm sweepLight DutyExhaust fan in metal frame working on 230 V A/C in the existing opening, fixingnecessaryanchor bolts / bolt and nuts etc., as required including giving connections with thesupplied wirealong with the exhaust fan.
10190.3.1Conveyance, installation, testing and commissioning of pre-wired fluorescent lightfittings with all accessories and fluorescent lamps of all types directly on wall andgiving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copperconductor flex wire or extending the original wiring and giving connections asrequired
10290.4.10Conveyance, installation , testing and commissioning of exhaust fans of size up to450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., asrequired including giving connections with the supplied wire along with the exhaustfan.
10390.4.8Charges for cutting holes suitable for accommodating exhaust fans up to 305mmsweep including plastering colour washing etc. as required.
1042.5.1Supplying and fixing of following ways surface/ recess mounting, vertical type, 415volts, TPN MCB distribution board of sheet steel, dust protected, duly powderpainted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.)4 WAY(4+12), DOUBLE DOOR
1052.4.2Supplying and fixing following way, horizontal type three pole and neutral, sheetsteel, MCB distribution board, 415 volts, on surface / recess, complete with tinnedcopper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)6 Way (4+18),Double door
1062.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps
1072.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
1082.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
1092.11Supplying and fixing single pole blanking plate in the existing MCB DB completeetc. as required.
11090.10.3.15Supply and Fixing the following modular switches & accessories in the existingfront plates and giving necessary connections as required (RoHS compliant )32A DPswitch with indicator
1115.17Providing and fixing 4.00 mm dia copper wire on surface or in recess for loopearthing as required.
1125.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc.(but without charcoal/ coke and salt) as required
1135.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired
11490.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG)
11590.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG)
116OD223743/2026-2027Supply & Providing 9 W LED Bulb with B22 base, working on 230 V AC supply
117OD223745/2026-2027SITC of 10 W LED bulkhead luminaire that fits seamlessly in a variety ofapplications, lumen output greater than 1100 lumens with a system efficacy > 110lm/W. The luminaire shall have a power factor > 0.9 and shall have 50,000burning hours as per L70 criteria. The luminaire shall be BIS certified and shallcomply all IEC safety requirements and test certificates of LM79 and LM80 reportsshall be submitted. The luminaire shall housing shall be made of High Pressure diecast aluminum with a UV stabilized polycarbonate diffuser, IP66 and IK 09protection,including all accessories necessary as required to complete installation.
11890.3.17.1Supply, conveyance and erection of the following sizes of 'B' class GIpipe in single section for post top lantern of all types on concrete base (excludingcharges for concrete base and excavation) and painting with 2 coats of syntheticenamel paint over a coat of zinc chromate primer etc. as required.32 mm dia GI pipe
119OD223748/2026-2027Supply and fixing of 6W led mirror light
120OD223749/2026-2027 METER BOX CUBICLE TYPE FABRICATED: Supplying and Installing by testingand commissioning of 3 Phase 440 V, 50 Hz IEC standard Meter box Cubicle type,dust and vermin proof with wall mounting/ recess by cutting the wall / making goodof damages/ color washing/fixing directly to wall by Anchor bolts made of CRCAsheet metal powder coated with three numbers of HRA fuse carriers , Neutral din Bar,Earth din bar, Provision for mounting kWH Meter etc.
12190.12.7.43Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 35 sq mm with factory made clamp
1229.1.35Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.4 X 35 sq. mm (32mm)
12390.12.7.41Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
1249.1.33Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.4 X 16 sq. mm (28mm)
1251.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1261.14.3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1271.26 Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required.
12890.4.1Supply and installation of suitable size MS rod type fan clamp in the RCC slab as perIS 732 as required.
12990.5.1.3Supply and fixing the following types of superior quality 250V A.C call bell onexisting M.S. box and giving connections with required length of 3 core, 16 / 0.20mm650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wireconforming to relevant ISS or with the extended original wiring, earthing the MS boxand making good the surface as required.Ding dong bell
130OD223742/2026-2027DOCUMENTATION AND APPROVAL - "Charges for Preparation of alldrawings submitting and getting approval from KSEB, submitting of Completioncertificates and arranging inspection, getting sanction from KSEB, obtaining powerallocation if necessary & power connection including energy meter etc. forcommissioning of the whole installation in the premises. All statutory payments willbe reimbursed on production of the original receipts
131OD223741/2026-2027Supplying, installing and commissioning Portable Fire extinguishers of followingtype & capacity.Co2 type Fire Extinguisher, made from brand new seamlessSteel cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and hornand Wheel type valve with initial Charge and mounted on Rubber Wheels / wallmounted brackets as per IS: 16018 specification, bearing ISI Mark.4.5 Kgs
132EXCLUSIVE OF GST
133Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
1342:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
1353.Rate should be Exclusive of GST.
1364.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
1375.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
1386.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
1397.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
1408.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
1419. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered)
14210.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
143Make of Electrical equipments/materials
144All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
145Panel Boards: CPRI certified reputed manufacturers make
146MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
147Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
148Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
149Cable Glands & Sockets - REPUTED MAKE , Cosmos
150Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
151Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
15211. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference.
15312.VITRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client
15413.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client
15514.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
15615. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref.
157GRANULAR SUB BASE: Quantity by level calculation & reporting to CTE as per norms Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58736670
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 03-12-2026
Authority
Authority Name Kerala Electrical And Allied Engineering Co Limited
Work Description Tender for Nabard-Ridf Tranche Xxxi- Infrastructure Development Of Various Offices Under Northern Circle, Kannur-Construction Of Forest Complex (Hostel Facility) At Kalpetta In Kalpetta Range, Wayanad District
Basic Detail
Tender No KRO/ BDC/2486/2026
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 26 Nov 2026
Submission Date 03 Dec 2026
Open Date 04 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee 5900
EMD 50000
Exemption Available
Document List
666063c9-e998-4378-a205-ff5ce5b7ea1b.html
BOQ_1528937.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 26, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Dec 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Dec 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

666063c9-e998-4378-a205-ff5ce5b7ea1b.html

xls

BOQ_1528937.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender