Educational and Research Institute Boards / Undertakings / PSU Closing in 16 days TDR #58727426

Tender For Civil Modification And Acoustic Treatment Works For Computational Facility Room At Homi Bhabha Centre For Science Education

Issued by Boards / Undertakings / PSU · Mumbai Suburban, Maharashtra
Tender Value
68.37 Lakhs
Estimated cost
Bid Submission
15 Dec 2026
16 days left
EMD
1.36 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Civil Modification And Acoustic Treatment Works For Computational Facility Room At Homi Bhabha Centre For Science Education

BOQ

Name of Work:- Civil Modification and Acoustic Treatment Works for Computational Facility Room at Homi Bhabha Centre for Science Education
Sl. No. Item Description
1Providing and placing in position square shaped working table of size 1200 mm (L) × 1200 mm (D) × 750 mm (H), made of 25 mm thick BWP plywood conforming to IS 710 standards of M/s. Century Ply, Green Ply, Duro Ply, Kit Ply, finished with 1.0 mm thick laminate on both sides of approved shade and finish will be fixed using standard approved adhesive, including 2mm thick edge beading on all exposed and cut edges of table top complete. The table top shall overhang 50 mm on all four sides beyond the supporting frame. The supporting structure shall be fabricated from Mild Steel (MS) sections comprising 40 × 40 X 2mm, MS members for vertical supports and horizontal members below the table top, including provision of MS frame fixed to the underside of table top prior to powder coating for securing the top with nut and bolt arrangement at uniform spacing. All MS members shall be powder coated with minimum 80 microns thickness of approved colour shade and finish. The table shall be provided with MS adjustable levelers at bottom of vertical supports, as per approved design complete in all respects as directed by Engineer-in-Charge.
2Making and placing executive table of Size 1500mm (L) x 750mm (D) and 750mm (H) with modesty panel on the front surface having table top and vertical sides to be made out of 18mm thick BWP plywood and other sections using 12 mm thick BWP plywood conforming to IS:710 standards of M/s. Century Ply, Green Ply, Duro Ply, Kit Ply make with both side 1mm thick lamination of standard approved make only, of approved shade and finish will be fixed using standard approved adhesive. All the cut edges of table are to be finished with 2mm thick PVC edge beading including necessary hardware such as cable organizer of M/s. Ebco, Hettich or standard approved equivalent and including labour, wastages, transportation etc. complete as directed by EIC.
3Making and placing side credenza storage unit of size 750mm (L) x 425mm (D) and 750mm (H) having top and vertical sides and doors to be made out of 18mm thick BWP plywood and other sections including shelves using 12 mm thick BWP plywood conforming to IS 710 standards of M/s. Century Ply, Green Ply, Duro Ply, Kit Ply make with outer side 1mm thick lamination and internal side 0.8mm thick lamination of standard approved make only, of approved shade and finish will be fixed using standard approved adhesive. All the cut edges of table are to be finished with 2mm thick PVC edge beading of same colour as of laminate, including all necessary hardware such as heavy-duty hydraulic hinges, handles, locks, magnetic ball catch of M/s. Hettich, Plantex or standard approved equivalent make and including labour, wastages, transportation etc. complete as directed by EIC.
4Providing and fixing writing surface of approx. size: 3m X 1.2m fixed on wall using 18mm thick plywood with back side 1mm thk. lamination of White colour fixed using standard approved adhesive and front surface is prepared uniformly to paste M/s. 3M or approved equivalent make WH whiteboard writing film uniformly without any bubbles or air gap, all the corner edges of board to be finished using 75x35 mm 2nd class Teak wood frame with moulded edges and rounded corners with clear PU polish, including necessary accessories and hardware etc. complete as per directions of EIC.
5Supply of ergonomically designed medium back chair of M/s. Godrej Interio, Nilkamal, Featherlite make with class 3 smooth gas lift mechanism for height adjustment, AN 70 Mesh back rest with adjustable lumper support back, tilt lock with upright position and tilt tension are adjustable. seat shall be in cushioned made of polyurethane foam with fabric ensemble, height adjustable arms with soft PU padding, 5-star type base in black nylon with 50mm heavy duty nylon castors (5nos), Load capacity ≥130 kg. Manufacturer should be BIFMA/ANSI compliant and complete with necessary accessories, hardware and warranty of minimum 1 year.
6Supply of ergonomically designed high back chair of M/s. Godrej Interio, Nilkamal, Featherlite make with class 3 smooth gas lift mechanism for height adjustment, AN 70 mesh back rest with adjustable lumper support back, soft cushioned head rest with 90 - 135 degrees titling, tilt lock with upright position and tilt tension are adjustable, mild steel chrome finished base, seat shall be in cushioned made of polyurethane foam with fabric ensemble, height adjustable arms with soft PU padding, chrome finish 5 star type base with 50mm heavy duty twin nylon castors (5nos), having Load capacity ≥130 kg. Manufacturer should be BIFMA/ANSI compliant and complete with necessary accessories, hardware and warranty of minimum 1 year.
7Providing and placing in position wooden podium/lectern as per approved design, drawing having size 700 mm (W) × 500 mm (D) × 1150 mm (H), made out of 18 mm thick marine BWP plywood conforming to IS:710 of M/s. Century Ply, Green Ply, Duro Ply, Kit Ply make, finished with 1 mm thick decorative laminate of approved shade, finish and make on all exposed surfaces and 0.8 mm thick laminate on internal surfaces fixed using approved standard adhesives, including 0.8mm thick PVC edge beading on all exposed edges. The podium shall consist of a sloping top reading platform with raised side and back lips to prevent documents/ laptop from slipping, and shall be provided with neat circular cut-out / metal grommet on top surface of M/s. Ebco, Hettich or standard approved equivalent and on intermediate shelves for microphone and cable management as required. The base shall be provided with a platform/footing for stability and suitable internal framing for rigidity. All plywood members shall be properly joined, screwed and finished smooth. The item shall include all necessary hardware, fixtures, fittings, cutting, edge finishing, labour, materials and wastage, transport etc. complete, as directed by the EIC.
8Providing and fixing 10 mm thick clear cast acrylic circular name plate/logo of approximately 300 mm dia. on the front face of podium, with (TIFR-HBCSE) approved logo in UV-resistant high-resolution printing, of colour and design as per original format, having polished edges and glossy finish, including concealed SS 304 grade studs/spacers, screws, adhesive and all necessary accessories for proper and rigid fixing to the laminated plywood surface, complete in all respects as per approved sample, drawings/design and directions of Engineer-in-Charge.
9Providing and applying frosted film of approved design on the glass panels of door with approved pattern and on required area as per the instructions and directions of the EIC. Complete.
10Supply and fixing of 304 grade Stainless Steel (SS) name plate of minimum 1.5mm thick and size as per requirement and letter should be engraved crisp and sharp in required font and size. The name plate should be waterproof and durable for outdoor use, including its transport, fixing with necessary SS mirror screws etc. complete as directed by EIC.
11Fabrication of full height storage unit as per detailed drawing and of depth as per requirement below, having Mild Steel (MS) frame with welded connections made out of 50mm X50mm X 2mm thick pipes of M/s. Jindal Steel, TATA Steel, Kamdhenu Pipes, Apollo Pipes make and fixed to the existing masonry wall surface with 8mm dia. X 80mm long Stainless-Steel anchor fasteners of M/s. Hilti, Fischer or approved standard equivalent make. Outer covering, intermediate shelving and shutters to be made out of 18mm thick marine BWP plywood and backing using 12mm thick marine BWP plywood both conforming to IS:710 standards of M/s. Century Ply, Green Ply, Duro Ply, Kit Ply make with both side 1mm thick lamination of standard approved make only having approved shade and finish and fixed using standard approved adhesives. All the cut edges of board to be finished with 0.8 mm thick PVC edge beading, including necessary accessories and hardware, all SS brushed finished handles, locks, magnetic ball catch for shutters, box type SS hinges, etc. of M/s. Hettich, Plantex or standard approved make, complete. as directed by EIC.
12Minimum 500mm depth with One open pocket at the bottom side of minimum size 700mm X 1500mm and shelves at every 500mm C/C all as per detailed drawing.
13Minimum 1500mm depth with One open pocket at the bottom side of minimum size 700mm X 1000mm and shelves at every 500mm C/C all as per detailed drawing.
14Providing and making and fixing of 300mm raised wooden platform using treated Sal wood 50mm X 50mm treated wooden framework below for supporting the platform at every 600mm c/c on both ways. Top and sides are covered with 25mm thick BWP plywood conforming to IS 710 standards of M/s. Century Ply, Green Ply, Duro Ply, Kit Ply make with 4mm thick veneer finish as per approved design and pattern on exposed surface and finished with clear PU polish including gap filling, surface sanding etc. and inner surfaces to be fire treated and varnished. all including transport, labour, wastages with necessary accessories and hardware etc. complete as directed by EIC.
15Providing and fixing of anti-static raised/ false flooring system with ramp in server room - i. Panels : Access floor panel shall be of size 600 x 600 mm x 34mm thick and shall have a compressed calcium sulphate, fiber reinforced core of minimum 1500kg/m³ density having an encapsulation of 0.5 mm thick Galvanized steel at bottom and 0.45mm thick PVC edge band on all four sides for edge protection M/s. PWS Floor or standard EIC approved equivalent make only. The panel after cleaning, degreasing, phosphating is to be finished with a 1mm thick Anti-static high-pressure laminate (HPL) sheet of approved design and colour. The panel should have following properties - Fire Resistance Rating - EN 13501-1: Class Al Fire Rating - ASTM E84 CLASS 1 or A RoHS - Metal - RoHS 4/ Non Metal - RoHS 10 Water Absorption (24 Hours) - 2.40% Concentrated Load ≥ 5.5 kNUltimate Load ≥ 11kNUniform Load ≥ 22kN/m2Pedestal Axial load ≥ 28 kN ii. Sub structure pedestal assembly: Substructure installed to support the panel shall be suitable to achieve a minimum clear height of 450 ± 25mm from the existing floor level. Pedestal design shall confirm speedy assembly and removal for relocation and maintenance. The assembly shall provide easy adjustment of levelling and accurately align panels for a maximum of ± 25 mm in the vertical direction. Pedestals shall support an axial load without permanent deflection and an ultimate load as laid out in System performance requirement for server room as described in Details (below BoQ table). The Pedestal head design shall provide self-engagement and firm positioning of the floor panel at ramp and raised floor area. The supporting structure shall consist of a modular galvanized steel structure with stringers of rectangular hollow section size 28mm x 38mm x 1mm thick fixed on the pedestal PVC head cap having Galvanized Iron (GI) stud at bottom, threaded and inserted inside the GI pipe resting on the GI base plate. This supporting structure to be fixed on floor with tested adhesives recommended by the manufacturer and as per approved drawings. Approved Make: M/s. PWS floor or approved standard equivalent make NOTE: The Cut-Outs for floor boxes are required to be made at locations as given in the detailed drawing at no extra cost.
16Providing and fixing of raised/ false flooring system with ramp - i. Panels : Access floor panel shall be of size 600 x 600 mm x 30mm thick and shall have a compressed calcium sulphate, fiber reinforced core of minimum 1500kg/m³ density having an encapsulation of 0.5 mm thick Galvanized steel at bottom and 0.45mm thick PVC edge band on all four sides for edge protection M/s. PWS Floor or standard EIC approved equivalent make only. The panel after cleaning, degreasing, phosphating is to be finished with a 4mm thick Fire-retardant acoustic carpet of approved design and colour. The panel should have following properties - Fire Resistance Rating - EN 13501-1: Class Al Fire Rating - ASTM E84 CLASS 1 or A RoHS - Metal - RoHS 4/ Non Metal - RoHS 10 Water Absorption (24 Hours) - 2.40% Concentrated Load ≥ 4.5 kNUltimate Load ≥ 9kNUniform Load ≥ 18kN/m2Pedestal Axial load ≥ 22 kN ii. Sub structure pedestal assembly: Substructure installed to support the panel shall be suitable to achieve a minimum clear height of 75 ± 5mm from the existing floor level. Pedestal design shall confirm speedy assembly and removal for relocation and maintenance. The assembly shall provide easy adjustment of levelling and accurately align panels. The Pedestal head design shall provide self-engagement and firm positioning of the floor panels at ramp area and on the raised platform. Galvanized Iron rectangular hollow pipe stringers to be provided at the bottom in ramp area only for stability and uniform load distribution over pedestals. The supporting structure shall consist of a pedestal PVC head cap having Galvanized Iron (GI) stud at bottom, threaded and inserted inside the GI pipe resting on the GI base plate. This supporting structure to be fixed on floor with tested adhesives recommended by the manufacturer and as per approved drawings. Approved Make: M/s. PWS floor or approved standard equivalent make NOTE: The Cut-Outs for floor boxes are required to be made at locations as given in the detailed drawing at no extra cost.
17Supply and installation of 9mm thick slim Polyfibre rigid panels of size 1200x2440x9mm thick, volume density 200kg/m3, weight 1.8kg/m2, Fire (Class) 'A' of M/s. Anutone Slim Plus or standard approved equivalent make, adhered on primer panels having square edge magnesite bonded pinewood fiber core tile of size 600mm X 2400mm X 10mm, volume density 400kgs/m3, weight 4kg/m2of M/s. Anutone (strand2) or standard approved equivalent make, installed on a GI high quality strut framework system having thickness 0.55mm, length 3600mm, knurled web 40mm, depth 10mm and equal flanges 15mm which is fastened to wall behind horizontally at every 600mm c/c of M/s. Anutone CC10 or standard approved equivalent make. Primer panels are back lined with a Synthetic Polyfibre sheet of size 600mm X 1500mm having density of 100kg/m3 of M/s. Anutone SynthPF 10x10 or standard approved equivalent make held in position with dab spots of Anutone stick S7. Anutone strand2 primer panel is installed on the strut CC10 with suitable fasteners at 600mm c/c. Longer edges of the panel should be perpendicular to length of strut CC10. Anutone stick S7 adhesive is to be applied on Anutone strand2 primer and at rear of slim panel. Prior to installation, ensure surface behind are flat, dry and free from dust or other contaminants and levelled. Slim panels are then adhered to strand2 primer panels behind with stick S7 adhesive. All work at any height including necessary hardware, transport, labour, wastage, cutting etc. complete as directed by EIC. Technical Parameters: \\"Fire (Class) - A,1/P, Acoustics - NRC (system) 0.7 , Thermal (W/m·K)-0.04, Climate (°C, RH) - 50, 99, Light (%) - Colour Dependent, Green(VoC, RC %) - Nil, 60
18Supply and installation of 12mm thick grooved strand wooden rigid polyester core panels of size 600mm X 1200mm X 21mm insitu fixed on polyester slim panels of size 600mm X 1200mm X 10mm thick, with NRC upto 0.8, composite volume density 380kg/m3, Fire (Class) 1 & P of M/s. Anutone Slim Striate or standard approved equivalent make, adhered on primer panels having square edge wood fiber core tile of size 600mm X 1200mm X 10mm, volume density 400kgs/m3, of M/s. Anutone Strand Ebony or standard approved equivalent make, installed on a GI high quality strut framework system having thickness 0.55mm, length 3600mm, knurled web 40mm, depth 10mm and equal flanges 15mm which is fastened to wall behind horizontally at every 600mm c/c of M/s. Anutone CC10 or standard approved equivalent make. Primer panels are back lined with a Synthetic Polyfibre sheet of size 600mm X 1500mm having density of 100kg/m3 of M/s. Anutone SynthPF 10x10 or standard approved equivalent make held in position with dab spots of Anutone stick S7. Anutone primer panel is installed on the strut CC10 with suitable fasteners at 600mm c/c. Longer edges of the panel should be perpendicular to length of strut CC10. Anutone stick S7 adhesive is to be applied on Anutone primer panel and at rear of slim panel. Prior to installation, ensure surface behind are flat, dry and free from dust or other contaminants and levelled. Slim strand panels are then adhered to primer panels behind with stick S7 adhesive. All work at any height including necessary clips or any other hardware, transport, labour, wastage, cutting etc. complete as directed by EIC. Technical Parameters: \\"Fire (Class) - 1&P, Acoustics - NRC (system) 0.9 , Thermal (W/m·K)-0.04, Climate (°C, RH) - 50, 70, Light (%) - Colour Dependent, Green(VoC, RC %) - Low, 25
19PROVIDING AND FIXING OPTIMA/ LYRA CONCEALED ACOUSTICAL FALSE CEILING: TILES: Mineral Fiber Acoustical Suspended False Ceiling System with 22mm thick Acoustics Optima/ Lyra Concealed Quick Kerf Edge Tiles of M/s. Armstrong/ Knauf/ Gyproc with concealed suspended grid. The tiles shall have smooth bright laminated visual with Humidity Resistance (RH) of 99%, NRC 0.7+ (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz), CAC of 35+ dB as per ASTM standards, Light Reflectance ≥88% as per ASTM, Colour White, Fire Performance of Class A as per ASTM E 84 with 22mm Quick Kerf edge type in module size of 600 x 600mm. The scrim on the face of the tile shall be cleanable, washable up to 500 cycle as per ASTM D-4828 and resistant to disinfectants. It shall be suitable for Green Building application, with Recycled content upto 71% having VOC and Formaldehyde emission rate less than 0.1mg/m2/hr. SUSPENSION: The tile shall be laid on Heavy-duty Prelude XL 15/16\\" suspension system installed using not less than 12-gauge galvanized steel hanger wire manufactured by M/s. Armstrong/ Knauf/ Gyproc confirming to ASTM C636 having 24 mm wide T- section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C636 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gms as per IS 277 (2003) and pre-painted steel with baked polyester paint. All border cross tee/main beam shall be levelled using perimeter fill. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using not less than 12-gauge galvanized steel hanger wire at 1200mm c/c maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as per Manufacturer recommended procedure. Suspension system accessories supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia 2.5 mm of 1.80 m. length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. The 24” concealed fixture trim should be fixed for every 600 X 600 mm grid wherever there will be a lighting fixture placed before placing the mineral fiber concealed tiles (as per the false ceiling layout drawing issued). Complete as per instructions and directions of Engineer-In-Charge.
20Providing and applying Two coats of wall care Putty of standard approved make on plastered surface and Ceiling and Walls upto any heights to prepare surface in line & level and smooth by scrapping, etc. complete.
21Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hours After applying acrylic wall putty with appropriate proportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45% or 65 to 70 % by roller.
22Providing and applying first single coat of approved primer and two coats of synthetic enamel paint/flat oil paint of an approved make and colour as per manufacturers specifications to surfaces specified below, at all height and locations as directed including scaffolding, cleaning and preparing surfaces for painting by any approved means etc. complete as directed by Engineer-in-charge.
23For steelwork
24Providing and fixing best quality CCTW door frame of specified finished size as mentioned below, including moulding, rebating, joints, M.S. hold fasts/anchors, and applying a priming coat and Two coats of premium enamel paint including transportation, labour, etc. complete as directed by EIC.
25100 mm x 50 mm
26Providing and fixing superior quality double leaf (full and half size) B.W.P. grade solid core flush door shutters of standard make conforming to IS:2202- 1991 (Part I & II) with 12 mm thk. teak wood lipping all around including all necessary fitting and fixtures such as door closer, 8\\" SS tower bolt, hinges of standard approved make and quality and its fixing on the existing metal frame etc. complete. as directed by EIC.
2735mm thick shutter
28Extra for cutting in door and providing glazed half height vision panels in the shutter of size and shape as per drawings and as directed by EIC.
29Extra for providing & fixing 1 mm thick Marine quality laminate to flush doors including all material and labour.
30Extra for providing and fixing of premium quality stainless steel door handle set of minimum 250mm long
31Dismantling brick masonry in lime or cement mortar and disposal of rubbish and debris out of premises and stacking the materials as directed with all leads, lifts etc. complete as directed by EIC.
32Breaking and removal of granite platform including safe opening and removal of aluminum storage framework and door shutters, disposal of rubbish and debris out of premises and stacking of serviceable aluminum framework with shutters within a lead of 100m complete. all as per instructions and directions of EIC.
33Breaking and removal of existing old loose internal/ external plaster, including raking out joints and cleaning the surface for new plaster application, at any heights with all scaffolding, site cleaning, tools, equipment required for complete job with site cleaning and debris disposal etc. Complete as per the instructions and directions of Engineer-In-Charge.
34Sand-faced plaster of any thickness
35Providing Cement plaster for internal walls, ceilings and other workable surfaces with 12-15 mm thick in CM 1:4 (1 cement: 4 fine sand) after surface preparation including cleaning , hacking of base R.C.C. surfaces, application of cement slurry all around, for all heights including scaffolding/staging, and providing GI plaster chicken mesh of 20 gauge stretched tight at all RCC/ PCC and masonry joints in 150mm wide strips on each surface; fixed with G.I. \\"U\\" type nails before plastering. All including tools, accessories, labour, wastage, finishing, curing, site cleaning etc. Complete as per instructions and directions of Engineer-In-Charge
36NOTE: 1. Silpoze Sand is permitted based on meeting the acceptance criteria. (Rates will be inclusive of all charges/ royalties against sand to be paid.) 2. Some area of plaster can be in patchwork of area less than or equal to 1 sqm. 3. Breaking of old plaster will be paid separately
37Removing Stainless Steel Kitchen Sink embedded in the granite frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc. complete
38Breaking and removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete
39Fixing of the full height partition using same Aluminum Sections and Particle boards etc. including replacement of all glazing caps with new colour (same as existing) anodized Aluminum glazing caps and necessary rubber gaskets complete as directed by EIC. (anodized to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
40Removal of old floor spring assembly with cover and filling of the same with Cement mortar (1:3) mix and its top finishing including stacking of the serviceable materials within a lead of 50m etc. complete as per the direction of Engineer-in-charge.
41Providing and fixing of new Aluminum Partition concealed door lock of M/s. Godrej or standard approved equivalent make for the existing door including removal of the existing lock from the door and making necessary alterations for fixing new lock in the existing space including labour, etc. complete as directed by EIC.
42Providing and fixing minimum 1.5mm thick anodized (anodic film must not be less than 15 microns as per IS, the anodizing must be escalated by keeping the anodized section in boiling de- anodized water for a period of one hour) aluminum fixed/ sliding / pivoted / top hung / side hung doors and partitions conforming to IS:1948, 1961 with hollow bottom section & standard section all around (top, bottom and sides) with shutter frame made up of standard handle section and standard top and bottom section with infill panel of plain glass/ prelaminated particle board as listed below with nylon guides, gliders glass fixing PVC weather strips, neoprene gasket, etc. complete with approved type of locking arrangement, handles and other fixtures such as door closer, locks, Stainless Steel Butt hinges including fixing, filling the gaps with silicon sealant, cleaning polishing the aluminium section as specified by the manufacturers etc. complete as directed by Engineer In Charge.
43Aluminum section used (anodized transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
44Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination of approved colour and shade on both sides
45Providing and fixing float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) for vision panel in aluminium door on side/ in fixed glazing over sliding windows and with EPDM rubber / neoprene gasket packing including removal of existing old glass panes if any etc. complete as per the directions of EIC.
46Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.20 mm at weight 0.643 Kilogram/One Running Meter. and window frame bottom track section 61.85 x 31.75 x 1.50 mm at weight 0.909 Kilogram/One Running Meter. Top and side track section 61.85 x 31.75 x 1.50 mm at weight 0.784 Kilogram/One Running Meter. The shutter should be of bearing bottom 40 x 18 x 1.42 mm at weight 0.494 Kilogram/One Running Meter. Inter locking section 40 x 18 x 1.29 mm at weight 0.547 Kilogram/One Running Meter. And handle and top section 40 x 18 x 1.42 mm at weight 0.494 Kilogram/One Running Meter, as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self-locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc., With matching colour Anodizing (min. thickness 15µ) complete. NOTE: Section weight will be taken into consideration over the thickness of the individual Aluminum section.
47Providing and making overhead storage cabinets made out of 12mm thick BWP plywood for backing and 18mm thick BWP plywood for rest of parts conforming to IS 710 standards of M/s. Century Ply, Green Ply, Duro Ply, Kit Ply make having Two Shelves and hinged doors with locking overlap and with door magnetic ball catch and locks of M/s. Godrej or standard approved equivalent make including all necessary accessories such as Stainless Steel staggered type heavy duty hinges and , stainless Steel handles of M/s. Hettich, Plantex or approved standard equivalent make. All outer faces of plywood shall be provided with 1 mm thick laminates and all inner faces shall be provided with 0.5mm thick laminates of M/s. Greenlam, Merino or approved standard equivalent make and of approved colour and finish including labour, transport, wastages etc. complete as per drawings and as directed by EIC
48Wall mounted/ Frame mounted overhead storage NOTE: Rates to be quoted for carpentry work only. The partition side supporting MS fabrication work will be paid in separate item.
49Extra for framework providing, cutting, fabricating and fixing of Mild Steel (MS) pipes with welded connections made out of 50mm X50mm X 2mm thick pipes of M/s. TATA Steel, Jindal Steel, Apollo Pipes, Kamdhenu Pipes make and fixed to the existing masonry wall surface and on floor with 8mm dia. X 80mm long Stainless Steel anchor fasteners of M/s. Hilti, Fischer or approved standard equivalent make as per approved design by EIC. complete.
50Providing and fixing Roller Blinds made out of a 100% Blackout fabric of M/s. Vista Fashions, Hunter Douglas or approved standard equivalent make & shade, having 38mm round Aluminium channel & tilting with chain (Ball) system with all necessary fixtures and fitting etc. complete. NOTE: window opening size will be considered for measurement.
51Removing double shutters of wooden doors with wooden frames and stacking the materials as directed with all leads, lifts etc. complete.
52Removing aluminium sliding windows with frames and stacking the materials as directed with all leads, lifts etc. complete.
53Dismantling wooden or A.C. partition/ storage including Aluminum and/ or Mild Steel (MS)framework with sliding/ openable doors including necessary cutting and stacking the materials as with all leads, lifts etc. complete, as directed by Engineer-In-Charge (EIC).
54Buyback - old partition/ Storage
55Aluminum Sections
56Particle board (approx.70Sqm.)
57Glass panels (approx. 50Sqm.)
58Wooden Door Shutters Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58727426
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 68.37 Lakhs
LAST DATE 15-12-2026
Authority
Authority Name tata institute of fundamental research
Work Description Tender For Civil Modification And Acoustic Treatment Works For Computational Facility Room At Homi Bhabha Centre For Science Education
Basic Detail
Tender No HBC/PUR/PUBLIC TENDER 47/2026-27
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 25 Nov 2026
Submission Date 15 Dec 2026
Open Date 16 Dec 2026
Finance
Tender Value 68.37 Lakhs
Tender Fee Ref. Documents
EMD 1.36 Lakhs
Exemption Not Available
Document List
3e69220b-1eb9-4d13-9a66-6fc11ce382bb.html
BOQ_983198.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Dec 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

3e69220b-1eb9-4d13-9a66-6fc11ce382bb.html

xls

BOQ_983198.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender