Tender For Renewal Of Ei, Powermains Arrangements And Pumproom Ltug Cable Arrangements In Rmnch Buildings And electrical installation In Various Places In Tirunelveli Medical College Hospital At Palayamkottai In Tirunelveli District
Tender Overview
Project Description
Tender for Renewal Of Ei, Powermains Arrangements And Pumproom Ltug Cable Arrangements In Rmnch Buildings And electrical installation In Various Places In Tirunelveli Medical College Hospital At Palayamkottai In Tirunelveli District
BOQ
| Sl. No. | Item Description |
| 1 | Rewiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC Rigid pipe on wall and ceiling with PVC accessories with suitable Module GI switch box on wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open PVC conduit Plug point ( 8 points / Coil) Higher End |
| 2 | Rewiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End |
| 3 | Renewal by supply and fixing of fancy glass shade and 7W / 9W LED bulb |
| 4 | Renewal by supply and fixing of 20W LED tube on existing Fitting. |
| 5 | Renewal by supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting |
| 6 | Renewal by Supply and fixing of 48W LED street light fitting with LED (Higher end) on existing post/wall. |
| 7 | Renewal by supply and fixing of 1200mm (48\\") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod on the existing fan clamp |
| 8 | Renewal by supply and fixing of 450mm wall fan on wall with connnection complete (with Almonard / Equ) |
| 9 | Renewal by supply and fixing of Stepped Electronic 300W / 450W Square Type Fan Regulator |
| 10 | Renewal by Supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete without provision of hole in the wall. |
| 11 | Renewal by supply and fixing of louvers shutters arrangements for 300mm (12\\") sweep (light duty) AC exhaust fan |
| 12 | Renewal by Supply and fixing of 5 Amps module switch. |
| 13 | Renewal by Supply and fixing of 5 Amps 3 Pin & 2 Pin Combined module Wall Socket only |
| 14 | Renewal by Supply and fixing of 12 Module Cover Plate. |
| 15 | Renewal by supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 3 nos. 6A to 32A SP MCB & 3 nos. 63A FP MCB as outgoing on wall with earth connection only. Higher End |
| 16 | Renewal by supply and fixing of 32A DP MCB in sheet enclosure in flush with wall with earth connection. (The MCB and metal enclosure should be with Legrand / Hager make) |
| 17 | Renewal by Supply and fixing of 63 FP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with necessary earth connection. (The MCB and metal enclosure should be of Higher End). |
| 18 | Renewal by supply and fixing of GI Hot Dip / Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height |
| 19 | Supply and laying of 3-1/2 x 35 sq.mm. PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good |
| 20 | Renewal by supply and clarnping of 3-1/2 x 35 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps |
| 21 | Renewal by supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection |
| 22 | Renewal by supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete |
| 23 | Renewal by supply and clarnping of 3-1/2 x 50 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps |
| 24 | Renewal by supply and Laying of 3 1/2 x 50 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. |
| 25 | Renewal by supply and frxing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection |
| 26 | Renewal by supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete |
| 27 | Renewal by supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour |
| 28 | Renewal by supply and run of 4 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour |
| 29 | Re-earthing as per P.W.D standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work. |
| 30 | Labour charges for dismantling damaged electrical Installations |
| 31 | Transportation Charges for dismantled items from work into the section office. |
| 32 | GST Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender