Housing Urban and Rular Development Government Departments Closing in 11 days TDR #58726202

Tender For Construction Of Godown For Evms & Vvpats At District Faridkot (Good Cum Passanger Lift & Dg Set 58.5 Kva (External Services)

Issued by Government Departments · Faridkot, Punjab
Tender Value
58.73 Lakhs
Estimated cost
Bid Submission
07 Dec 2026
11 days left
EMD
1.17 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Faridkot → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Godown For Evms & Vvpats At District Faridkot (Good Cum Passanger Lift & Dg Set 58.5 Kva (External Services)

BOQ

Name of Work:- Construction of Godown for EVMs & VVPATs at District Faridkot (Good Cum Passanger Lift & DG Set 58.5 KVA (External Services)
Sl. No. Item Description
1Goods Cum Passanger Lift
2Type and Capacity : Approximately 2000 Kg , Goods cum Passengers Lift with Machine Room LessSpeed: 0.5 to 1.0 Meter per secondType of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rai within the elevator hoist wayTravel: Approximately 10 Meter (Ground to Second Floor)Serving: 3 Floors 3 Stops 3 Openings 3 Levels (All on the same side) Hoist way : 2970mm (Wide) x 2910mm (Deep) Clear dimensionsHeadroom Height (HR): 5000 mm beyond finished floor level of last landing Pit Depth : 1600mm below the finish floor level of first landingCar Size Area: Minimum 5.0 square meterCar Enclosure Constructed out of stainless steel finish panel in Scratch Resistance/ Vandal proofCar Entrance: Four panel Center Opening Automatic Doors of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 1700mm (wide) x 2000mm (high). Fire Resistance Door upto 2hrs.
3Hoist way Entrance: Four panel Center Opening Automatic Doors of Stainless steefinish panel in Scratch Resistance/ Vandal proof with a clear opening of 1700mm (wide) x 2000mm (high)Door operation : Automatic DC Door operation with adjustable door opening and closing timingsControl: Simplex full selective collective control with and without attentdent Operation: AutomaticPower Supply: 415 Volts, 3- phase, 50Hz Alternating Current Flooring: Floor Skid - Resistant as per standardFan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car LightingIndicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landingsHand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear)Call Bukon Height: Call button (Outside the lift) placed at a height between 800mm 1meter from the floor levelControl Panel Height: Control panel placed at a height between 800mm-1meter from the floor level
4Other Features1. Battery operated emergency light with rechargeable battery2. Battery operated emergency alarm with rechargeable battery3. Adjustable Guide shoes4. Micro movement LED based factors.5. Door Open and Close buttons6. Emergency Intercom provided inside the elevator7. Emergency Intercom usable without the voice communication8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication9. Steel items, door frames sill angle's, fascia plates, spring buffers10. Automatic phase reversal device and Phase Failure protection11. Call registration12. Audio & Video System installted in the lift indicating arrival at a floor13. Manual break lever14. Additional car gate lock
515. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close. 19. Car Operating Panel. 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of stee. 21. Phase two device fire man drive 22. Fire Man switch at main lobby. 23. Car false ceiling in stainless steel. 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging. 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure. 28.The use of visually and acoustically reflective wall surfaces should be minimized within the lift car as visual reflections can cause discomfort and affect the visua acuity of people with impaiments. 29. The Floor of the lift car should be slip resistant and have similar frictional qualitites to the floor of the lift landing to decrease the risk of stumbling. 30. The Provision of a mirror on the wall of the lift car opposite the lift door is a postive aid to navigation for wheelchair users, Its allows the wheelcahir user to see if anyone is behind them and also to see the Floor indicatior panel. The mirror should not extend below 900mm from the lift door to avoid confusing people with impaired sight. 31.The emergency communication system should be coupled with and induction loop system installed all around the lift. Telephone units. where provided, should have an inbulit inductive coupler to aiist person using hearing aids. passenger lift to be provided, which allows easy maneuverability of wheelchair user.
6Cost of Silent DG Silent 58.5KVA with CPCB-4+ norms
7COPPER EARTHING (Upto 14 metre in Length):
8Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/SteelNut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
9Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length)
10COPPER EARTHING STRIP (As Additional Length):
11Fixing additional Length of earthing with Copper Tape (On Surface/Flushed)with petty material as required etc.:-
12Additional Length 25mm x 3mm thick Copper Tape
13Supply, Erection, Testing and Commissioning of Water Cooled Silent DG Set 58.5KVA/46.8KW without AMF Panel, Three Phase, 415VoIts, 50Hz, 1500 RPM Silent (Sound Proof) Diesel Generator Set. It should be Water cooled naturally aspirated turbo charged/ turbo charged after cool (As per manufacturer standard).ENGINE: The Diesel engine developing minimum 74.4 BHP for giving a power rating as pe ISO 8528- Part-1 (With CPCB-IV Norms upto date amendments) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacture standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements.
14ENGINE CONTROL PANEL: Engine control panel liked and having digital display i.e Start/stop key switch/push button, battery charging indication, Engine Hours indications Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication.ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled
15Alternator should have 40 degree maximum class H insulation, Automatic voltageregulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transien load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be Suitable fo outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc. Warranty pertod of DG set shall be for period of 2 year from date of commissioning.
16MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mmsheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-42 degree of protection & front operated, composite meter fo digital display. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternato or dynamo liked on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site. 5 Critical parts of engine (cylinder hood. cylinder block for shaft, crank shaft, connecting rod) shall be warranted for 5 years from date of dispatch. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58726202
AUTHORITY Government Departments
TENDER VALUE 58.73 Lakhs
LAST DATE 07-12-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Godown For Evms & Vvpats At District Faridkot (Good Cum Passanger Lift & Dg Set 58.5 Kva (External Services)
Basic Detail
Tender No 10/2-2026-27
Bidding Type Tender
Location
City Faridkot
State Punjab
Key Dates
Publish Date 26 Nov 2026
Submission Date 07 Dec 2026
Open Date 07 Dec 2026
Finance
Tender Value 58.73 Lakhs
Tender Fee 5000
EMD 1.17 Lakhs
Exemption Not Available
Document List
1c03e2e4-6131-443a-b56b-e7e2718b9d51.html
BOQ_367648.xls
SBDEVMFdk.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 26, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

1c03e2e4-6131-443a-b56b-e7e2718b9d51.html

xls

BOQ_367648.xls

pdf

SBDEVMFdk.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender