Defence Government Departments Closing in 4 days TDR #58725069

Tender For Repair And Maintenance Of 08 Nos/02 Block Type-1 Residential Qtr (Qtr No. 75 To 92 ) Out Lived More Than 20 Years And Overhead Line To Ug Cable From Pundri Transformer To 40 Nos/10 Blocks Type -1 Qtrs To Under Tc&S Bsf Hzb (Sh-Electrical,

Issued by Government Departments · Hazaribagh, Jharkhand
Tender Value
18.63 Lakhs
Estimated cost
Bid Submission
03 Dec 2026
4 days left
EMD
37277
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hazaribagh → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of 08 Nos/02 Block Type-1 Residential Qtr (Qtr No. 75 To 92 ) Out Lived More Than 20 Years And Overhead Line To Ug Cable From Pundri Transformer To 40 Nos/10 Blocks Type -1 Qtrs To Under Tc&S Bsf Hzb (Sh-Electrical, Installation, Wiring And Service Connection).

BOQ

Name of Work:- Repair and maintenance of 08 Nos/02 Block Type-1 residential Qtr (Qtr No. 75 to 92 ) out lived more than 20 years and overhead line to UG cable from Pundri Transformer to 40 Nos/10 Blocks Type -1 Qtrs to under TC&S BSF HZB (SH-Electrical, installation, wiring and service connection).
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required (Group A)
2Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
4(i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
5(ii) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
6Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required
7Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
8Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (i) 20 mm
9Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box / wooden block i/c connection etc as required.
10Supplying and fixing PVC batten/ angle holder including connections etc. as required.
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
12(i)5/6 amps switch
13(ii) 3 pin 5/6 A socket outlet
14(iii) TV antenna socket outlet
15Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
16Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
17Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
18Supplying and fixing call bell / buzzer suitable for single phase, 230 V complete as required.
19Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
20Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB /Isolator)
2112 way , Double door
22Supplying and fixing 5 A to 32 A rating 240/415 volts,\\"C\\" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.
23Single pole
24Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
26Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
27Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
28Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7metre long etc. with charcoal/ coke and salt as required.
29Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
30Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
31Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required.
32Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
33Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
34Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
35Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
36LED Batten light (System lumen efficacy ≥105 85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
3718- 22 Watt
38Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
394 X 25 sq. mm
40Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
414 X 25 sq. mm (28mm)
423½ X 35 sq. mm (32mm)
433½ X 50 sq. mm (35mm)
443½ X 120 sq. mm (45mm)
453½ X 150 sq. mm (50mm)
46Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
471200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
48Supply, installation, testing and commissioning of 10 watt LED bulkhead fittings with IP 66 ingress protection complete with all accessories and electronic driver, etc as required directly on wall, including connections etc. as required. Make Havells Cat HEXAFTHEXAFT10WLED857SSYMBOPC or equivalent make : (Crompton/ GM/ Philips)
49Supply, installation, testing and commissioning of 600 mm (nominal size) 9/10 watt LED batten luminaire with minimum light output 100 lumen/watt complete with all accessories, electronic driver, diffuser, directly on ceiling/ wall, including connections etc. as required. Make Havells cat LUMILINE+BS10WLED865SPCSS or equivalent make : (Crompton/ GM/ Philips)
50LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
5150 Watt
52Supplying and installation of exhuast fan with louver shutter 230 mm sweep in the existing opening including making the hole to suit the size of the above fan and making good the damage, connection, testing , commissioning etc as required.Make Havells Cat Ventil Air DS or equivalent Make Crompton/ C&G / Orient / Usha / Almonard)
53Providing, laying and fixing 40 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required ( for protection of UG cable)
54Supplying and Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, armoured UG electric cable with aluminium conductor of size 4 x 25 sq.mm. direct in ground including excavation and refilling the trench but excluding sand cushioning & protective covering.Make-Havells/L&T/Polycab/KEI..
55Supplying and Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, armoured UG electric cable with aluminium conductor of size 3.5 x 70 sq.mm. direct in ground including excavation and refilling the trench but excluding sand cushioning & protective covering.Make-Havells/L&T/Polycab/KEI..
56Supplying and Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, armoured UG electric cable with aluminium conductor of size 3.5 x 120 sq.mm. direct in ground including excavation and refilling the trench but excluding sand cushioning & protective covering.Make-Havells/L&T/Polycab/KEI..
57Supplying and Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, armoured UG electric cable with aluminium conductor of size 3.5 x 150 sq.mm. direct in ground including excavation and refilling the trench but excluding sand cushioning & protective covering.Make-Havells/L&T/Polycab/KEI..
58Supplying and Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, armoured UG electric cable with aluminium conductor of size 3.5 x 185 sq.mm. direct in ground including excavation and refilling the trench but excluding sand cushioning & protective covering.Make-Havells/L&T/Polycab/KEI..
59Supplying and Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, armoured UG electric cable with aluminium conductor of size 4 x 25 sq.mm.in the existing RCC/ HUME/METAL pipe as required..Make-Havells/L&T/Polycab/KEI..
60Supplying and Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, armoured UG electric cable with aluminium conductor of size 3.5 x 120 sq.mm.in the existing RCC/ HUME/METAL pipe as required..Make-Havells/L&T/Polycab/KEI..
61Supplying and Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, armoured UG electric cable with aluminium conductor of size 3.5 x 150 sq.mm.in the existing RCC/ HUME/METAL pipe as required..Make-Havells/L&T/Polycab/KEI..
62Supplying and Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade as per IS 7098 (Part 1) 1988, armoured UG electric cable with aluminium conductor of size 3.5 x 185 sq.mm.in the existing RCC/ HUME/METAL pipe as required..Make-Havells/L&T/Polycab/KEI..
63Supply, Installation, Testing and Commissioning of double door, out door type totally enclosed, dust and vermin proof, pedestal mounted Main Feeder Pillar of suitable size but not less than 1200 mm wide X 1200 mm high X 400 mm (deep) fabricated from 2 mm thick CRCA sheet steel, having double door in the front, front and rearside openable hinged type door (double leaf), front and back tapered top, consisting of 400 Amps 4 strip aluminium bus bars with heat shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals for complete cross section, complete with detachable cable gland plates made of 3 mm thick CRCA sheet, earthing studs, separators, supports and insulators. The feeder pillar should be provided with suitable size terminal blocks for incoming & outgoing cables. From MCCB to terminal blocks connection will be done with solid aluminium bus bar / conductor. Incoming / outgoing cables will be terminated in terminal blocks. Including pre paint treatment, phosphating and powder coating by approved Siemens grey paint, suitable for operation on 433 volt, 50 Hz, 3 phase, 4 wire A. C. supply system complete including providing and fixing the following mountings, switchgears and accessories therein, etc as required. The feeder pillar shall be supplied with suitable pedestal of 50mm x 50 mm x 6 mm angle iron frame with 900 mm long legs. The 4 legs of the above feeder pillar are to be grouted in cement concrete 1:3:6 (1 Cement :3 Coarse sand: 6 Graded Stone aggregate 40 mm nominal size) foundation 60 cms. below ground level and 30 cms. above ground including finishing etc (embedded legs, should not be less than 450 mm) including plastering complete as required as per specifications, M.V danger notice plate on front side (drawing will be get approved before fabrication of panel)320 A, FP MCCB 35/36 KA, Ics = 100% Icu, with adjustable thermal and adjustable magnetic release (S/C & O/L) protection, with spreader terminals : 1 No (Make: L&T/ABB/Siemens/Schenider/Legrand)200 A, TP MCCB 25/26 KA, Ics = 100% Icu, with thermal and magnetic release (S/C & O/L) protection, with spreader terminals : 1 No (Make: L&T/ABB/Siemens/Schenider/Legrand)63 A, TP MCCB 10 KA, Ics = 100% Icu, with thermal and magnetic release (S/C & O/L) protection, with spreader terminals : 1 No (Make: L&T/ABB/Siemens/Schenider/Legrand)25/32 A, TP MCCB 10 KA, Ics = 100% Icu, with thermal and magnetic release (S/C & O/L) protection, with spreader terminals : 4 No (Make: L&T/ABB/Siemens/Schenider/Legrand)Indicator Lamp LED type, 03 Nos
64Supply, Installation, Testing and Commissioning of double door, out door type totally enclosed, dust and vermin proof, pedestal mounted Main Feeder Pillar of suitable size but not less than 1200 mm wide X 1200 mm high X 400 mm (deep) fabricated from 2 mm thick CRCA sheet steel, having double door in the front, front and rearside openable hinged type door (double leaf), front and back tapered top, consisting of 400 Amps 4 strip aluminium bus bars with heat shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals for complete cross section, complete with detachable cable gland plates made of 3 mm thick CRCA sheet, earthing studs, separators, supports and insulators. The feeder pillar should be provided with suitable size terminal blocks for incoming & outgoing cables. From MCCB to terminal blocks connection will be done with solid aluminium bus bar / conductor. Incoming / outgoing cables will be terminated in terminal blocks. Including pre paint treatment, phosphating and powder coating by approved Siemens grey paint, suitable for operation on 433 volt, 50 Hz, 3 phase, 4 wire A. C. supply system complete including providing and fixing the following mountings, switchgears and accessories therein, etc as required. The feeder pillar shall be supplied with suitable pedestal of 50mm x 50 mm x 6 mm angle iron frame with 900 mm long legs. The 4 legs of the above feeder pillar are to be grouted in cement concrete 1:3:6 (1 Cement :3 Coarse sand: 6 Graded Stone aggregate 40 mm nominal size) foundation 60 cms. below ground level and 30 cms. above ground including finishing etc (embedded legs, should not be less than 450 mm) including plastering complete as required as per specifications, M.V danger notice plate on front side (drawing will be get approved before fabrication of panel)160 A, FP MCCB 35/36 KA, Ics = 100% Icu, with adjustable thermal and adjustable magnetic release (S/C & O/L) protection, with spreader terminals : 1 No (Make: L&T/ABB/Siemens/Schenider/Legrand)25/32 A, TP MCCB 10 KA, Ics = 100% Icu, with thermal and magnetic release (S/C & O/L) protection, with spreader terminals : 4 No (Make: L&T/ABB/Siemens/Schenider/Legrand)Indicator Lamp LED type, 03 Nos
65Supply, Installation, Testing and Commissioning of double door, indoor type totally enclosed, dust and vermin proof, pedestal mounted Main Feeder Pillar of suitable size but not less than 800 mm wide X 800 mm high X 300 mm (deep) fabricated from 2 mm thick CRCA sheet steel, having double door in the front, front and rearside openable hinged type door (double leaf), front and back tapered top, consisting of 100 Amps 4 strip aluminium bus bars with heat shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals for complete cross section, complete with detachable cable gland plates made of 3 mm thick CRCA sheet, earthing studs, separators, supports and insulators. The feeder pillar should be provided with suitable size terminal blocks for incoming & outgoing cables. From MCCB to terminal blocks connection will be done with solid aluminium bus bar / conductor. Incoming / outgoing cables will be terminated in terminal blocks. Including pre paint treatment, phosphating and powder coating by approved Siemens grey paint, suitable for operation on 433 volt, 50 Hz, 3 phase, 4 wire A. C. supply system complete including providing and fixing the following mountings, switchgears and accessories therein, etc as required. The panel shall be provided with suitable wall-mounting brackets/supports, fabricated from adequately sized structural steel sections, complete with necessary anchor fasteners, bolts, nuts and accessories for securely fixing the panel to the wall. The mounting arrangement shall be designed to safely support the complete weight of the panel and its installed equipment. including plastering complete as required as per specifications, M.V danger notice plate on front side (Detailed fabrication drawing, and internal component layout shall be submitted for approval before fabrication of the panel.)25 A, FP MCCB 10 KA, Ics = 100% Icu, with thermal and magnetic release (S/C & O/L) protection, with spreader terminals : 1 No (Make: L&T/ABB/Siemens/Schenider/Legrand)2 pole, 40 amps, C-curve MCB make L&T Model No.-BB20630C or equivalent make of ABB/Schneider/Siemens/Havells-04 Nos.AC single phase electronic kwh energy meter of rating 5-30A, Class 1.0,240V,50 Hz, counter type display of L&T Make - 04 NosIndicator Lamp LED type, 03 Nos
66Supply, Installation, Testing and Commissioning of double door, out door type totally enclosed, dust and vermin proof, pedestal mounted Main Feeder Pillar of suitable size but not less than 400 mm wide X 400 mm high X 300 mm (deep) fabricated from 2 mm thick CRCA sheet steel, having double door in the front, front and rearside openable hinged type door (double leaf), front and back tapered top, consisting of 200 Amps 4 strip aluminium bus bars with heat shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals for complete cross section, complete with detachable cable gland plates made of 3 mm thick CRCA sheet, earthing studs, separators, supports and insulators. The feeder pillar should be provided with suitable size terminal blocks for incoming & outgoing cables. Including pre paint treatment, phosphating and powder coating by approved Siemens grey paint, suitable for operation on 433 volt, 50 Hz, 3 phase, 4 wire A. C. supply system complete including providing and fixing the following mountings, switchgears and accessories therein, etc as required. The feeder pillar shall be supplied with suitable pedestal of 50 mm x 50 mm x 6 mm angle iron frame with 600 mm long legs. The 4 legs of the above feeder pillar are to be grouted in cement concrete 1:3:6 (1 Cement :3 Coarse sand: 6 Graded Stone aggregate 40 mm nominal size) foundation 30 cms. below ground level and 30 cms. above ground including finishing etc (embedded legs, should not be less than 300 mm) including plastering complete as required as per specifications, M.V danger notice plate on front side (drawing will be get approved before fabrication of panel)Indicator Lamp LED type, 03 Nos Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58725069
AUTHORITY Government Departments
TENDER VALUE 18.63 Lakhs
LAST DATE 03-12-2026
Authority
Authority Name Border Security Force
Work Description Tender for Repair And Maintenance Of 08 Nos/02 Block Type-1 Residential Qtr (Qtr No. 75 To 92 ) Out Lived More Than 20 Years And Overhead Line To Ug Cable From Pundri Transformer To 40 Nos/10 Blocks Type -1 Qtrs To Under Tc&S Bsf Hzb (Sh-Electrical, Installation, Wiring And Service Connection).
Basic Detail
Tender No 02/EE (E)/TCS/ HBAG/2026-27
Bidding Type Tender
Location
City Hazaribagh
State Jharkhand
Key Dates
Publish Date 26 Nov 2026
Submission Date 03 Dec 2026
Open Date 04 Dec 2026
Finance
Tender Value 18.63 Lakhs
Tender Fee Ref. Documents
EMD 37277
Exemption Not Available
Document List
BOQ_983190.xls
e5067663-587f-4624-8e46-85f1478028e9.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Dec 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_983190.xls

html

e5067663-587f-4624-8e46-85f1478028e9.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender