Science and Technology Statutory Bodies & Commissions/Committees Closing in 18 days TDR #58723177

Bids Are invited for Boq Price Bid

Issued by Statutory Bodies & Commissions/Committees · Hyderabad, Telangana
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Dec 2026
18 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Not Available
Quantity
108

Project Description

Bids Are invited for Split Air Conditioner 1.8 - 2.0 Ton - Supply, Installation, Testing, And Commissioning (Sitc) Of Single Phase, 5 Star, Inverter Hi-Wall Split Type Air Conditioner Unit, Capable Of Performing Cooling With Nominal Capacity 1.8/2.0 Tr With A Minimum Cooling Capacity Of 6,100 Watts And Above. Unit Shall Be Supplied With Manufacturer Offered Copper Pipe (3 Meters), Power & Communication Cable, Drain Pipe And Mounting Stands For Both Indoor And Outdoor Unit Along With All Necessary Accessories For Installation Of Air Conditioning Unit. This Work Also Includes Core Cutting For Accommodating Refrigerant Pipe, Cables And Drain Pipe. Refer Annexure-I For Detailed Specifications And Scope Of Work. , Split Air Conditioner 1.5 Ton - Supply, Installation, Testing, And Commissioning (Sitc) Of Single Phase, 5 Star, Inverter Hi-Wall Split Type Air Conditioner Unit, Capable Of Performing Cooling With Nominal Capacity 1.5 Tr With A Minimum Cooling Capacity Of 5,100 Watts And Above. Unit Shall Be Supplied With Manufacturer Offered Copper Pipe (3 Meters), Power & Communication Cable, Drain Pipe And Mounting Stands For Both Indoor And Outdoor Unit Along With All Necessary Accessories For Installation Of Air Conditioning Unit. This Work Also Includes Core Cutting For Accommodating Refrigerant Pipe, Cables And Drain Pipe. Refer Annexure-I For Detailed Specifications And Scope Of Work. , Split Air Conditioner 1 Ton - Supply, Installation, Testing, And Commissioning (Sitc) Of Single Phase, 5 Star, Inverter Hi-Wall Split Type Air Conditioner Unit, Capable Of Performing Cooling With Nominal Capacity 1.0 Tr With A Minimum Cooling Capacity Of 3,200 Watts And Above. Unit Shall Be Supplied With Manufacturer Offered Copper Pipe (3 Meters), Power & Communication Cable, Drain Pipe And Mounting Stands For Both Indoor And Outdoor Unit Along With All Necessary Accessories For Installation Of Air Conditioning Unit. This Work Also Includes Core Cutting For Accommodating Refrigerant Pipe, Cables And Drain Pipe. Refer Annexure-I For Detailed Specifications And Scope Of Work. , Automatic Voltage Stabilizer - Supply, Installation, Testing And Commissioning Of 5 Kva Stabilizer Including Standard Test Reports Please Refer Annexure-I For Detailed Specifications And Scope Of Work. , Automatic Voltage Stabilizer - Supply Installation Testing And Commissioning Of 4 Kva Stabilizer Including Standard Test Reportsplease Refer Annexure-I For Detailed Specifications And Scope Of Work. , Copper Tube - Supply And Commissioning Of Two 02 Runs Of Copper Pipe Suitable For Connecting Indoor And Outdoor Units Of High Wall Split Air Conditioner Units With 09 Mm Nitrile Rubber Closed Cell Insulation Of Following Sizesrefer Annexure - I For Detailed Specifications , Pvc Conduict Pipe - Supply Of Isi 20 Mm Outer Dia Rigid Pvc Pipe For Connecting Drain Pipe Of Hi-Wall Split Ac Indoor Unit. , Uninstallation - Removing Of Existing Split Air-Conditioner Units.

BOQ

Sl. No. Item TitleItem Description
1split air conditioner 1.8 - 2.0 tonSupply, installation, testing, and commissioning (SITC) of single phase, 5 star, Inverter hi-wall split type air conditioner unit, capable of performing cooling with nominal capacity 1.8/2.0 TR with a minimum cooling capacity of 6,100 Watts and above. Unit shall be supplied with manufacturer offered copper pipe (3 meters), power & communication cable, drain pipe and mounting stands for both indoor and outdoor unit along with all necessary accessories for installation of air conditioning unit. This work also includes core cutting for accommodating refrigerant pipe, cables and drain pipe. Refer Annexure-I for detailed specifications and scope of work.
2split air conditioner 1.5 tonSupply, installation, testing, and commissioning (SITC) of single phase, 5 star, Inverter hi-wall split type air conditioner unit, capable of performing cooling with nominal capacity 1.5 TR with a minimum cooling capacity of 5,100 Watts and above. Unit shall be supplied with manufacturer offered copper pipe (3 meters), power & communication cable, drain pipe and mounting stands for both indoor and outdoor unit along with all necessary accessories for installation of air conditioning unit. This work also includes core cutting for accommodating refrigerant pipe, cables and drain pipe. Refer Annexure-I for detailed specifications and scope of work.
3split air conditioner 1 tonSupply, installation, testing, and commissioning (SITC) of single phase, 5 star, Inverter hi-wall split type air conditioner unit, capable of performing cooling with nominal capacity 1.0 TR with a minimum cooling capacity of 3,200 Watts and above. Unit shall be supplied with manufacturer offered copper pipe (3 meters), power & communication cable, drain pipe and mounting stands for both indoor and outdoor unit along with all necessary accessories for installation of air conditioning unit. This work also includes core cutting for accommodating refrigerant pipe, cables and drain pipe. Refer Annexure-I for detailed specifications and scope of work.
4Automatic Voltage StabilizerSupply, installation, testing and commissioning of 5 KVA stabilizer including standard test reports Please refer annexure-I for detailed specifications and scope of work.
5Automatic Voltage StabilizerSupply installation testing and commissioning of 4 KVA stabilizer including standard test reportsPlease refer annexure-I for detailed specifications and scope of work.
6copper tubeSupply and commissioning of Two 02 runs of Copper pipe suitable for connecting indoor and outdoor units of high wall split air conditioner units with 09 mm nitrile rubber closed cell insulation of following sizesRefer annexure - I for detailed specifications
7pvc conduict pipeSupply of ISI 20 mm outer dia rigid PVC pipe for connecting drain pipe of Hi-wall split ac indoor unit.
8uninstallationRemoving of existing split air-conditioner units.

AI Tender Summary

OUR REF NO 58723177
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 16-12-2026
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Bids Are invited for Split Air Conditioner 1.8 - 2.0 Ton - Supply, Installation, Testing, And Commissioning (Sitc) Of Single Phase, 5 Star, Inverter Hi-Wall Split Type Air Conditioner Unit, Capable Of Performing Cooling With Nominal Capacity 1.8/2.0 Tr With A Minimum Cooling Capacity Of 6,100 Watts And Above. Unit Shall Be Supplied With Manufacturer Offered Copper Pipe (3 Meters), Power & Communication Cable, Drain Pipe And Mounting Stands For Both Indoor And Outdoor Unit Along With All Necessary Accessories For Installation Of Air Conditioning Unit. This Work Also Includes Core Cutting For Accommodating Refrigerant Pipe, Cables And Drain Pipe. Refer Annexure-I For Detailed Specifications And Scope Of Work. , Split Air Conditioner 1.5 Ton - Supply, Installation, Testing, And Commissioning (Sitc) Of Single Phase, 5 Star, Inverter Hi-Wall Split Type Air Conditioner Unit, Capable Of Performing Cooling With Nominal Capacity 1.5 Tr With A Minimum Cooling Capacity Of 5,100 Watts And Above. Unit Shall Be Supplied With Manufacturer Offered Copper Pipe (3 Meters), Power & Communication Cable, Drain Pipe And Mounting Stands For Both Indoor And Outdoor Unit Along With All Necessary Accessories For Installation Of Air Conditioning Unit. This Work Also Includes Core Cutting For Accommodating Refrigerant Pipe, Cables And Drain Pipe. Refer Annexure-I For Detailed Specifications And Scope Of Work. , Split Air Conditioner 1 Ton - Supply, Installation, Testing, And Commissioning (Sitc) Of Single Phase, 5 Star, Inverter Hi-Wall Split Type Air Conditioner Unit, Capable Of Performing Cooling With Nominal Capacity 1.0 Tr With A Minimum Cooling Capacity Of 3,200 Watts And Above. Unit Shall Be Supplied With Manufacturer Offered Copper Pipe (3 Meters), Power & Communication Cable, Drain Pipe And Mounting Stands For Both Indoor And Outdoor Unit Along With All Necessary Accessories For Installation Of Air Conditioning Unit. This Work Also Includes Core Cutting For Accommodating Refrigerant Pipe, Cables And Drain Pipe. Refer Annexure-I For Detailed Specifications And Scope Of Work. , Automatic Voltage Stabilizer - Supply, Installation, Testing And Commissioning Of 5 Kva Stabilizer Including Standard Test Reports Please Refer Annexure-I For Detailed Specifications And Scope Of Work. , Automatic Voltage Stabilizer - Supply Installation Testing And Commissioning Of 4 Kva Stabilizer Including Standard Test Reportsplease Refer Annexure-I For Detailed Specifications And Scope Of Work. , Copper Tube - Supply And Commissioning Of Two 02 Runs Of Copper Pipe Suitable For Connecting Indoor And Outdoor Units Of High Wall Split Air Conditioner Units With 09 Mm Nitrile Rubber Closed Cell Insulation Of Following Sizesrefer Annexure - I For Detailed Specifications , Pvc Conduict Pipe - Supply Of Isi 20 Mm Outer Dia Rigid Pvc Pipe For Connecting Drain Pipe Of Hi-Wall Split Ac Indoor Unit. , Uninstallation - Removing Of Existing Split Air-Conditioner Units.
Basic Detail
Tender No GEM/2026/B/8308992
Bidding Type Tender
Location
City Hyderabad
State Telangana
Key Dates
Publish Date 25 Nov 2026
Submission Date 16 Dec 2026
Open Date 17 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
42731cdd-8894-42e2-a0ca-5508ed96d9d7.pdf
detailed_technical_specifications_2026-11-23-16-53-49_cdc54489019214e02b6ddf1bf7d117dc.pdf
10206492_Boq_1.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Dec 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

42731cdd-8894-42e2-a0ca-5508ed96d9d7.pdf

pdf

detailed_technical_specifications_2026-11-23-16-53-49_cdc54489019214e02b6ddf1bf7d117dc.pdf

xlsx

10206492_Boq_1.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender