Tender For Annual Maintenance,Special Repairs And Other Electrical Works At Government Arts And Science College, Vedasandur In Dindigul District.
Tender Value
1.97 Lakhs
Estimated cost
Bid Submission
11 Dec 2026
15 days left
EMD
2000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dindigul → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Maintenance,Special Repairs And Other Electrical Works At Government Arts And Science College, Vedasandur In Dindigul District.
BOQ
| Sl. No. | Item Description |
| 1 | Supply of casual labour in the cadre of Electrical Helper to assist the section officer in day to day maintenance works, fuse of calls, etc. period for the year 2026-27. |
| 2 | Re-wiring with 2 x 1.5 sq.mm. PVC insulated unsheathed FRLS SC copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch inflush with wall covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light / fan point (for electronic regulator) (5 points per coil). |
| 3 | Renewal by Supply and fixing of 100W LED Integral Flood light fitting in die cast Aluminium housing IP 66 (Higher end) with AI frame of size 1.5mtr on wall / ceiling with PVC unsheathed Copper leads from terminals to the fitting. |
| 4 | Renewal by supply and fixing of 4feet 20W LED Tube in existing in SBT / TPT / Mirror optic luminaries complete with connections. |
| 5 | Renewal by supply and fixing of 7W / 9W LED bulb in existing lamp holder. |
| 6 | Renewal by supply and fixing of 1200mm (48\\") sweep AC ceiling fan High speed complete with 1 module 100W fan step regulator (Higher end) with 300 mm down rod on the existing fan clamp |
| 7 | Renewal of 2.5 mfd 250V AC fan capacitor for existing ceiling fan and fitting complete. |
| 8 | Renewal by supply and fixing of Dimmer Type Electronic 300W / 450W Square Type Fan Regulator in existing switch board and providing connection complete. |
| 9 | Renewal by supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete without provision of hole in the wall. |
| 10 | Renewal by supply and fixing of 5A flush type switch in existing switch board and providing connection complete. |
| 11 | Renewal by supply and fixing of 5A 3 pin and 2 pin Combined flush type wall socket in existing switch board and connection complete. |
| 12 | Renewal by supply and fixing of 15A 3 pin Combined flush type wall socket with 15A flush type switch in existing switch board and connection complete. |
| 13 | Renewal by Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch on suitable TW Box. |
| 14 | Renewal by supply and run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour. |
| 15 | Supply erection, testing and commissioning of 1.5 TR (4500 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions ofCooling, Dehumidifying, Air Circulating, FilteringThe installation works for the above split type AC units includes the following.1.Mounting / Fitting Indoor and outdoor units at their respective locations. 2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required.3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing. 4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit.5. Leakage testing the entire system unit. 6. Charging refrigerant gas in the unit.7. Suitable electric wiring to be provided with 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit (Carrier/Voltas/O General). |
| 16 | Supply of 4KVA Electronic Automatic Voltage Stabilizer (Higher end) with Input Voltage range of 170Volt – 270 Volt and Output Voltage range 200Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. |
| 17 | Supply and fixing of water drain pipe line (1\\" PVC pipe). |
| 18 | Supply and fixing of MS stand for fixing Outdoor unit. |
| 19 | Supply and laying of 5/8\\" and 3/8\\" copper refrigerant pipe of 0.8mm thick with 2.5 sqmm 3 core chord between indoor and outdoor unit. (Extra beyond 3 mts supplied with AC unit). |
| 20 | Renewal by supply and fixing of 30W LED street light fitting with LED (Higher end) on the existing post / on wall with PVC unsheathed FRLS copper leads. |
| 21 | GST@ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysDec 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender