Tender for General-Ircu Vertical Expansion Of Main Hospital Building Above Ward No. 8-Vertical Expansion Of Main Hospital Building Above Ward No. 8 For Setting Up Of Ircu, Advanced Pft Sleep Lab, Bronchoscopy Suite And A Pulmonology Ward Government Medical Collège Hospital, Thiruvananthapuram-Electrical Ac Work
BOQ
| Sl. No. | Item Description |
| 1 | Air-Conditioning |
| 2 | OD162649/2026-2027:Supply , installation , testing and commissioning of High Walltype VRF indoor units with wireless remote controller.indoor unit capable of operation on long mode to make air flow upto 12 m ,5 step vane controlled swing , operating on suitable green refrigerant with copper material coil type evaporating units capable for cooling, indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. etc. and suitable for 230 V 50Hz Power supply The indoor unit fixed on wall or suitable place with suitable size factory made stand. , making good the damages including filling excess holes by filler material like silica gel /puff etc and testing and commissioning unit-1 TR HI WALL TYPR VRF INDOOR UNIT . |
| 3 | OD175132/2026-2027:Supply , installation , testing and commissioning of High Wall type VRF indoor units with wireless remote controller. Indoor unit capable of operation on long mode to make air flow upto 12 m ,5 step vane controlled swing , operating on suitable green refrigerant with copper material coil type evaporating units capable for cooling, all indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. etc. and suitable for 230 V 50Hz Power supply The indoor unit fixed on wall or suitable place with suitable size factory made stand. , making good the damages including filling excess holes by filler material like silica gel /puff etc and testing and commissioning unit -1.5TR HI WALL TYPR VRF INDOOR UNIT |
| 4 | OD162650/2026-2027:Supply , installation , testing and commissioning of cassette type VRF indoor units with wireless remote controller. The indoor unit shall be of the four-way cassette type indoor units as per the requirements specified in the boq / drawings. all indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. all indoor units should have inbuilt drain pump with minimum 700mm vertical lift head . electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50hz.n with filter incluidng fixing on ceiling with suitable material and testing and commissioing etc VRF 4-WAY CASSETTE TYPE - 2 TR . |
| 5 | OD162647/2026-2027:Supply, installation, testing & commissioning of high static ductable unit. The indoor unit shall be of the high static ductable as per the requirements specified. All indoor units should have inbuilt drain pump with minimum 700mm vertical lift head. Indoor fan motors shall be BLDC type .all indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50h Z.I. casing shall be made of galvanized steel sheet (G.S.S) with minimum 0.8 mm thickness. Zinc coating thickness on G.S.S shall be of minimum 220 GSM. ii. Inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii. Unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display. High Static Ductable Unit 6 TR. |
| 6 | OD162645/2026-2027:Supply, installation, testing & commissioning of modular type VRF ODU. The outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoors units of the VRF/VRV system shall be compact air-cooled type. All the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/twin rotary type. OEM should use there on make compressors in VRF /VRV system which is to be supplied. System cop shall not be less than ? 3.4 at Air condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre coated at factory. The anti-corrosive treatment should have been tested for at least 2500 hrs of standard salt spray test and must have a certified life of minimum 20 years supported by certificate from reputed international institution is mandatory. The treatment should be suitable for areas of high pollution and salt laden air. modular system to be configured as per mention modules given in bracket. 22 HP . |
| 7 | OD162644/2026-2027:Supply, installation, testing and commissioning of Y joints indoor side, JRBLN03321, JRBLN07121 JRBLN014521. |
| 8 | OD162643/2026-2027:Supply, installation, testing and commissioning of Y joints outdoor side, ARCNN21. |
| 9 | OD162642/2026-2027:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ41.3 |
| 10 | OD162678/2026-2027:SUPPLY AND PROVIDING REFRIGERANT COPPER PIPING WITH 18 G HD COPPER PIPES, INSULATED WITH 19MM THICK NITRILE RUBBER TUBINGS FINISHED WITH GLASS CLOTH POLY SHIELD COATING OF APPROVED MAKE WITH PROPER SUPPORT Ø 38.1 MM |
| 11 | OD162677/2026-2027:SUPPLY AND PROVIDING REFRIGERANT COPPER PIPING WITH 18 G HD COPPER PIPES, INSULATED WITH 19MM THICK NITRILE RUBBER TUBINGS FINISHED WITH GLASS CLOTH POLY SHIELD COATING OF APPROVED MAKE WITH PROPER SUPPORT Ø31.8 MM |
| 12 | OD162676/2026-2027:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ28.6 |
| 13 | OD162675/2026-2027:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper support 22.2 mm dia |
| 14 | OD162674/2026-2027:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ19.1 |
| 15 | OD162681/2026-2027:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ15.9 |
| 16 | OD162680/2026-2027:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ12.7 |
| 17 | OD162691/2026-2027:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ9.53 |
| 18 | OD162690/2026-2027:SUPPLY AND PROVIDING REFRIGERANT COPPER PIPING WITH 18 G HD COPPER PIPES, INSULATED WITH 19MM THICK NITRILE RUBBER TUBINGS FINISHED WITH GLASS CLOTH POLY SHIELD COATING OF APPROVED MAKE WITH PROPER SUPPORT Ø 6.35 MM |
| 19 | OD179187/2026-2027:Supply and Providing 1.5 sqmm Two core Sheild Cable PVC insulated, PVC sheathes copper cable suitable for communication and laying in the existing condut as required. |
| 20 | 16.12.1.1:Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.63 mm sheet |
| 21 | 16.12.1.2:Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.80 mm sheet |
| 22 | 16.17:Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core. |
| 23 | 16.18:Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core. |
| 24 | OD162752/2026-2027:SUPPLY & INSTALLATION OF FRESH AIR LOUVER |
| 25 | OD162753/2026-2027:SUPPLY AND INSTALLING OF THERMAL INSULATION OF DUCTS WITH ALUMINIUM FOIL COVERED WITH NITRILE RUBBER 13MM THICK COMPLETE AS REQUIRED. |
| 26 | OD162754/2026-2027:SUPPLY AND INSTALLING OF ACOUSTIC INSULATION OF DUCTS WITH NITRILE RUBBER 10MM THICK COMPLETE AS REQUIRED. |
| 27 | OD162755/2026-2027:SUPPLY AND PROVIDING HEAVY DUCT FLEXIBLE DOUBLE LAYER FIRE-RETARDANT CANVAS CONNECTION WITH REXIN SHALL BE PROVIDED AT THE OUTLET OF DUCTABLE SPLIT/PACKAGE UNIT AND ALSO FOR EXPAND JOINTS WITH NECESSARY FLANGES, SUPPORTS ETC AS REQUIRED. |
| 28 | 16.20.1:Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper |
| 29 | 16.20.2:Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator |
| 30 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 31 | 1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 32 | 4.1.4:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 33 | 4.1.2:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 34 | OD162719/2026-2027:Supply and fixing 32 mm UPVC drain pipe with all accessories and surface/recess including cutting wall and making good the damages as required |
| 35 | OD162720/2026-2027:Charges for suppling and filling the R410A refrigerant gas in the air conditioning system |
| 36 | OD162871/2026-2027:Supply and fixing ofSelf-adhesive vinyl sticker for lettering and figures of sizes and colour selected by the Engineer in charge for the identification mark to fan, AC, SB, DB, panel board , fire etc as required |
| 37 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender