Housing Urban and Rular Development Government Departments Closing in 20 days TDR #58714100

Tender For Extension Of Shayama Prasad Mukharjee Community Hall At Hojai Municipal Board Office Complex, Hojai Under 15Th Finance Commission (Untied Fund) Under Hojai Municipal Board.

Issued by Government Departments · Hojai, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Dec 2026
20 days left
EMD
58900
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hojai → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Extension Of Shayama Prasad Mukharjee Community Hall At Hojai Municipal Board Office Complex, Hojai Under 15Th Finance Commission (Untied Fund) Under Hojai Municipal Board.

BOQ

Name of Work:- Extension of Shayama Prasad Mukharjee Community Hall at Hojai Municipal Board Office Complex, Hojai under 15th Finance Commission (Untied Fund) under Hojai municipal Board.
Sl. No. Item Description
1Extension of Community Hall
2Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
4Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
5Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet
6Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
7Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : Of sectional area 40 square centimetres and above
8Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
9Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
10Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineerin-charge.
11Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
12Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
13Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
14Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.1 Mild steel and Medium Tensile steel bars
15Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (ii)Super Ductile (SD) TMT reinforcement bars
16Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.1 Mild steel and Medium Tensile steel bars
17Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
18Lintels, beams, plinth beams, girders, bressumers and cantilevers
19Suspended floors, roofs, landings, balconies and access platform
20Columns, Pillars, Piers, Abutments, Posts and Struts
21Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
22Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
23Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
24Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
25Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand)
26Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
27Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood. 30 mm thick shutters
28Providing and fixing panelling or panelling and glazing in panelledor panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Float glass panes : 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
29Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.
30Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)
31100x85x5.5 mm (heavy type)
32Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete : 250x10 mm
33150x10 mm
34Providing and fixing bright finished brass door latch with necessary screws etc. complete : 250x16x5 mm
35Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
36Providing and fixing bright finished brass handles with screws etc. complete: 125 mm
37100 mm
38Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes. (50mm x 40 mm x 3.0mm)
3952 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
40Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size
41Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m²
42Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/ m².
43Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the . . . . screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board.
4412 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
45Finishing walls with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm)
46Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
47Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
48Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
49Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
50Providing and fixing WPC (Wood Plastic Composite) fluted louver wall panels of approved shade and pattern, made from eco-friendly composite material consisting of PVC/WPC base with embossed wooden texture finish. The panels shall be 12 inch (300 mm) in width and 8 feet (2400 mm) in length, having a minimum thickness as per manufacturer specification, and designed with interlocking grooves for seamless installation. The work includes cutting, shaping, edge finishing, fixing on existing surface using manufacturerrecommended screws, clips, fasteners, and adhesive, including providing necessary wooden/Aluminium battens as base framework wherever required. All complete as per direction of Engineer-in-Charge.
51Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
52Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
53Supplying and fixing metal box of 180mm X 100mm X 60mmdeep (nominal size) on surface or in recess with suitable size offixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano typeswitch, connections, painting etc. as required.
54Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 AMP switch
5515/16 AMP switch
563 pin 5/6 A socket outlet
576 pin 15/16 A socket outlet
58Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
592 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
602 X 4 sq. mm + 1 X 4 sq. mm earth wire
612 X 6 sq. mm + 1 X 6 sq. mm earth wire
62Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2 + 8 way, Double door
63Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
64Supplying and fixing following rating, Double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
65Supplying and fixing call bell/buzzer suitable for single phase, 230 V, complete as required.
66Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
67Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
68Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30CM with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet coveron the fan box etc. as required.
69Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
70Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
71Supplying of energy efficient 2 star rating Ceiling fan 1200mm sweep (make-Havells electrict Ceiling Fan) in the existing arrangement as directed by the department. 1200mm sweep Ceiling fan(make-Havells electrict Ceiling Fan) .Rates considered as per enclosed document downloaded from GeM on 12.03.22
72Supplying including installation, testing and commissioning of Wall mounting Speaker as specified and directedby the depptt.Ahuja Two way wall mounting Speaker (OSX-66T)
73Supplying including installation of LED surface/recessed type luminaries as approved by the Deptt.) Centaur LED Cool Day Light Aluminium Square LED surface ceiling LightCentaur LEDR(CPSE/SFPL/12R/12SQ)Rates considered as per enclosed document downloaded from GeM on 25.04.22
74Supplying of following rating( 9 Watt) of LED round shape bulbLED 9 Watt round shape bulb.Rates considered as per enclosed document downloaded from GeM on 17.03.22
75Supplying of 20 Watt LED Tube Light (Make-Bajaj Electrict ,Best Quality) as required and directed by the department. 20 Watt LED Tube Light (Make-Bajaj Electrict ,Best Quality)Rates considered as per enclosed document downloaded from GeM on 12.03.22
76Supplying including installation, commissioning of SERVOKON Digital Volt Meter with selector switch to measure Input/Output Voltage 4.0 KVA Automatic Line Voltage Corrector or Step Type Auto Transformer (SSL4KVA Automatic). Rates considered as per enclosed document downloaded from GeM on 05-04-22.
77Supplying including installation, commissioning of BLUE STAR 1.5 TON AC With 4BEE Star Rating (BLUE STAR & IC418 SERIES). Rates considered as per enclosed document downloaded from GeM on 05-0422. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58714100
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 16-12-2026
Authority
Authority Name Urban Development Department
Work Description Tender for Extension Of Shayama Prasad Mukharjee Community Hall At Hojai Municipal Board Office Complex, Hojai Under 15Th Finance Commission (Untied Fund) Under Hojai Municipal Board.
Basic Detail
Tender No HMB/T-13/2026
Bidding Type Tender
Location
City Hojai
State Assam
Key Dates
Publish Date 25 Nov 2026
Submission Date 16 Dec 2026
Open Date 16 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee 2500
EMD 58900
Exemption Not Available
Document List
1140a508-6972-41bb-a4d7-a95f1571b575.html
BOQ_86319.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Dec 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

1140a508-6972-41bb-a4d7-a95f1571b575.html

xls

BOQ_86319.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender