Heavy Industries and Public Enterprises Government Departments Closing in 11 days TDR #58714051

Tender For Tender For Construction Of Sub-Block Veterinary Dispensary Building At Sankerko, Amarda, Chandua And Kundabai Various Locations In The District Of Mayurbhanj, Odisha Including Architectural Consultancy Services

Issued by Government Departments · Mayurbhanj, Odisha
Tender Value
5.11 Crore
Estimated cost
Bid Submission
09 Dec 2026
11 days left
EMD
10.23 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mayurbhanj → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Tender For Construction Of Sub-Block Veterinary Dispensary Building At Sankerko, Amarda, Chandua And Kundabai Various Locations In The District Of Mayurbhanj, Odisha Including Architectural Consultancy Services

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 26-Nov-2026 Corrigendum I Other 09-Dec-2026

BOQ

Name of Work:- Tender for Construction of Sub-Block Veterinary Dispensary Building at Sankerko, Amarda, Chandua and Kundabai various locations in the district of Mayurbhanj, Odisha including architectural consultancy services
Sl. No. Item Description
1Tender for Construction of Sub-Block Veterinary Dispensary Building at Sankerko, Amarda, Chandua and Kundabai various locations in the district of Mayurbhanj, Odisha including architectural consultancy services Tender for Construction of Sub-Block Veterinary Dispensary Building at Sankerko, Amarda, Chandua and Kundabai various locations in the district of Mayurbhanj, Odisha including architectural consultancy services NIT No.: EPI/PCO/BBSR/1059/273 Dt: 25.11.2026 Sl. No. Description of Works Amount in Rs. SANKERKO AMARDA CHANDUA KUNDABAI A. Architectiral Consultancy Services 88828.6 88966.77 89172.01 88907.1 B. CIVIL WORKS. 9272489.0 9299198.0 9320194.0 9283616.0 C. P.H. WORKS. 1242389.0 1235418.0 1243743.0 1242476.0 D. ELECTRICAL WORKS. 2174922.0 2174922.0 2174922.0 2174922.0 TOTAL 12778628.6 12798504.77 12828031.01 12789921.1 TOTAL (SAY) 51195085.0 Rupees: Five Crore Eleven Lakh Ninety Five Thousand &Eighty Five Only ABSTRACT FOR CONSTRUCTION OF VETERINARY HOSPITALSAT SBVD-SANKERKO, BARSAHI, MAYURBHANJ DISTRICT. Description Of Item Qty Unit Rate Amount in Rs. Architectural Consultancy Services Architectural Consultancy Services 1.0 LS 88828.6 88828.6 Sub Total 88828.6 A CIVIL WORK i SBVD Building
2Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department as directed by the Engineer-In-Charge.
3Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works up to and including 1.5 metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
4Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth:consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.
5Carriage of earth by mechanical means with cost of all lead & lift upto 5 km including cost of all labour, T&P etc., comp. as directed by the Engineer-In-charge.
6Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer in charge. (Measurement will be taken on finished compacted section only)
7Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).
8Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 40 mm hard granite crusher broken metal), mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period .including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
9Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 25mm to 40 mm hard granite crusher broken metal) , mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period. including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
10Providing, lifting, hoisting and laying reinforced cement concrete of M-25 grade in following items as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes after curing of 28 days after mixing and test conducted in accordance with I.S. 516 using 10 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including centring,shuttering,hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. a) Footing. 27.48 Cum 7888.44 216774.33 b) Plinth beams 16.675 Cum 8771.67 146267.6 c) Roof Beam i) GF 16.675 Cum 17303.47 288535.36 ii) FF 9.536 Cum 19385.9 184863.94 iii) TF 1.848 Cum 24861.73 45944.48 d) Lintel i) GF 4.159 cum 15646.59 65074.17 ii) FF 2.661 cum 17397.31 46294.24 e) Chajja i) GF 11.813 Sqm 1339.34 15821.62 ii) FF 7.695 Sqm 1517.6 11677.93 iii) TF 2.025 Sqm 1986.85 4023.37 f) Roof slab i) GF 28.735 cum 15251.05 438238.92 ii) FF 11.994 cum 16922.66 202970.38 iii) TF 7.313 cum 21314.83 155875.35 g) Column i) GF 12.852 Cum 17303.47 222384.2 ii) FF 6.903 Cum 19385.9 133820.87 iii) TF 2.592 Cum 24861.73 64441.6 h) Staircase i) GF 3.759 cum 17157.73 64495.91 ii) FF 3.759 cum 19191.6 72141.22
11Providing, fixing and placing of Fe-500/ Tor steel (HYSD) for RCC work in lintel of required diameter with straightening, Cutting, bending, binding welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, taxes of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T & P and scaffolding complete in all respect as directed by the Engineer-in-Charge (payment will be made according to the actual weight of M.S rod /Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost) i) GF 144.16 Qntl 8907.25 1284069.16 ii) FF 49.372 Qntl 8941.35 441452.33 iii) TF 14.714 Qntl 9014.75 132643.03
12First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
13First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. i) GF 69.897 Cum 5860.28 409615.99 ii) FF 53.886 Cum 6246.3 336588.12 iii) TF 18.036 Cum 7200.7 129871.83
14First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
15Providing 16mm thick cement plaster with cement mortar of (1:6) to the brick surface including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc. complete as per direction of the Engineer-in-charge i) GF 468.234 Sqm 284.89 133395.18 ii) FF 285.144 Sqm 292.02 83267.75 iii) TF 19.698 Sqm 306.94 6046.1
16Providing 12mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. i) GF 435.487 Sqm 197.96 86209.01 ii) FF 274.314 Sqm 205.9 56481.25 iii) TF 19.005 Sqm 222.99 4237.92
17Providing 6mm thick cement plaster in all floors at all height with cement mortar of mix (1:4) to RCC surface finished smooth including deep chipping and slurry treatment with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. i) GF 243.799 Sqm 219.85 53599.21 ii) FF 95.951 Sqm 225.44 21631.19 iii) TF 58.5 Sqm 237.12 13871.52
18Providing and applying to inside,outside walls with one or more coats Priming coat with Cement Primer exterior grade of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. i) GF 1147.52 Sqm 81.81 93878.61 ii) FF 655.409 Sqm 83.85 54956.04 iii) TF 97.203 Sqm 88.14 8567.47
19Providing and applying to outside walls with two or more coats 100% Acrylic emulsion paint (1st quality) exterior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. i) GF 468.234 Sqm 98.69 46210.01 ii) FF 285.144 Sqm 102.39 29195.89 iii) TF 19.698 Sqm 110.36 2173.87
20Providing and applying to inside walls with two or more coats 100% Acrylic emulsion paint (1st quality) interior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding, Staging and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. i) GF 679.286 Sqm 105.6 71732.6 ii) FF 370.27 Sqm 107.8 39915.11 iii) TF 77.505 Sqm 112.44 8714.66
21Providing and applying white cement based putty interior grade of average thickness 1 mm of approved brand and manufacturer, over the inside plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. i) GF 679.286 Sqm 86.42 58703.9 ii) FF 655.409 Sqm 88.35 57905.39 iii) TF 97.204 Sqm 92.39 8980.68
22Supplying, fitting and fixing well dressed and well seasoned sal wood choukaths framed and fixed (wrought and put up) in trusses, purlines frames of doors, windows, ventilators and beams.of different length in proper position including two coats coats of coaltaring to wall and lintel side faces of choukaths including cost of coaltar and labour for coaltaring and fixing required nos. of W.I. clamps to the choukaths with approved qualities of screws including cost, conveyance, loading, sundries, T&P required for the work etc. complete in all respect with cost, conveyance, royalties, loading, unloading and taxes of all materials and cost of all labour, T&P, sundries, scaffolding etc. required for the work complete in all respect as per specification and direction of Engineer-In-Charge.
23Providing, fitting and fixing of approved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size, bothside finished with 1mm thk. laminate of approved colour & shade fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, i.e. hinges, door stopper, door buffer,Handle, Lock etc. of Godrej of equivalent approved make with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge at all floors and all heights.
24Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
25Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one side of shutter.
26Providing and fixing factory made uPVC white colour sliding glazed window/ventilator upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Twotrack two panels sliding window (Two nos. glazed ) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
27Providing and fixing M.S Grill/Gate of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply) at all floors and all heights.
28Providing & Painting 2 coats enamel paint (1st quality) of approved colour & brand on new work including cost of paint in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labour, etc. complete as per specification and direction of Engineer-In-Charge. i) GF 11.17 Sqm 187.87 2098.51 ii) FF 12.005 Sqm 192.39 2309.64
29Providing and laying Vitrified floor tiles 600x600/600x1200 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. i) GF 99.144 Sqm 1217.5 120707.82 ii) FF 85.196 Sqm 1231.23 104895.87
30Providing and laying Vitrified skirting tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. i) GF 12.099 Sqm 1464.55 17719.59 ii) FF 12.687 Sqm 1484.15 18829.41
31Providing and laying Matte Finish Vitrified floor tiles 300x300 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement:4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights.
32Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) minimum thickness 5mm of approved make in all colours, shades except burgundy, bottle green, black of size 300x200 in skirting and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete as per direction of EIC. In all floors and all heights .
33Providing and fixing 16mm thick Kota stone flooring (sample of Kota stone should be approved by Engineer-In-Charge) for floor and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. i) GF 153.768 Sqm 1267.2 194854.81 ii) FF 47.217 Sqm 1280.8 60475.53
34Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor at all floors and all heights. ========== TOTAL SBVD BUILDING (In Rs.) = 8402677.0 ii SHED Building.:-
35Excavation of founation & all civil work in hard rock (granite) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per specification approved by the Department as directed by the Engineer-In-Charge.
36Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department as directed by the Engineer-In-charge.
37Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works up to and including 1.5 metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
38Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth:consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.
39Carriage of earth by mechanical means with cost of all lead & lift upto 5 km including cost of all labour, T&P etc., comp. as directed by the Engineer-In-charge.
40Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer in charge. (Measurement will be taken on finished compacted section only)
41Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).
42Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 40 mm hard granite crusher broken metal), mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period .including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
43Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 25mm to 40 mm hard granite crusher broken metal) , mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period. including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
44Providing, lifting, hoisting and laying reinforced cement concrete of M-25 grade in following items as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes after curing of 28 days after mixing and test conducted in accordance with I.S. 516 using 10 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including centring,shuttering,hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. a) Footing 7.749 Cum 7888.44 61127.52 b) Plinth beams 3.011 Cum 8771.67 26411.5 c) Roof Beam 3.873 Cum 17303.47 67016.34 d) Roof slab 5.715 cum 15251.05 87159.75 e) Column 3.456 Cum 17303.47 59800.79
45Providing, fixing and placing of Fe-500/ Tor steel (HYSD) for RCC work in lintel of required diameter of with straightening, Cutting, bending, binding welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, taxes of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T & P and scaffolding complete in all respect as directed by the Engineer-in-Charge (payment will be made according to the actual weight of M.S rod /Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost)
46First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement (PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
47First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
48Providing 16mm thick cement plaster with cement mortar of (1:6) to the brick surface including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc. complete as per direction of the Engineer-in-charge.
49Providing 12mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.
50Providing 6mm thick cement plaster in all floors at all height with cement mortar of mix (1:4) to RCC surface finished smooth including deep chipping and slurry treatment with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.
51Providing and applying to inside,outside walls with one or more coats Priming coat with Cement Primer exterior grade of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
52Providing and applying to outside walls with two or more coats 100% Acrylic emulsion paint (1st quality) exterior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
53Providing and applying to inside walls with two or more coats 100% Acrylic emulsion paint (1st quality) interior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding, Staging and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
54Providing and applying white cement based putty interior grade of average thickness 1 mm of approved brand and manufacturer, over the inside plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
55Providing and fixing 16mm thick Kota stone flooring (sample of Kota stone should be approved by Engineer-In-Charge) for floor and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.
56Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor at all floors and all heights. ========== TOTAL SHED BUILDING (In Rs.) = 869812.0 TOTAL CIVIL WORKS 9272489.0 B P.H Work i. Internal & External PH
57Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer-in-charge. a 20mm Dia CPVC Pipe 6.0 Mtr 275.6 1653.6 b 25mm Dia CPVC pipe 15.0 Mtr 363.9 5458.5 c 25 mm dia PVC ASTM (Sch-80) pipe 10.0 Mtr 211.5 2115.0 d 32 mm dia PVC ASTM (Sch-80) pipe 8.0 Mtr 275.6 2204.8 e 40mm dia PVC ASTM (Sch-80) pipe 8.0 Mtr 361.1 2888.8 f 50mm dia PVC ASTM (Sch-80) pipe 6.0 Mtr 447.9 2687.4
58Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer-in-charge.250mm Thick Wall
59Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.
60Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.
61Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. a) 15mm dia long body Bib Cock cock 1.0 Each 1451.9 1451.9 b) 15mm dia CP S.B Bib cock 4.0 Each 1082.8 4331.2 c) 20mm dia CP concealed stop cock 1.0 Each 1378.1 1378.1 d) 15mm dia CP angle stop cock 16.0 Each 1673.3 26772.8 e) 15mm dia CP Pillar cock 6.0 Each 1624.1 9744.6 f) 15mm dia CP Health faucet 5.0 Each 1328.8 6644.0 g) 15mm dia Two way Bib Cock 5.0 Each 1255.0 6275.0 h) Shower Arm 1.0 Each 639.8 639.8 i) Over head shower 100mm dia round 1.0 Each 2116.3 2116.3 j) 32mm dia CP Bottle trap 3.0 Each 1747.2 5241.6 k) Auto closing concealed urinal flush valve 1.0 Each 2288.5 2288.5 l) 15mm dia CP SINK cock 2.0 Each 2067.1 4134.2 m) Soap Dispenser with glass bottle 5.0 Each 1328.8 6644.0 n) CP soap Dish holder 2.0 Each 1698.0 3396.0 o) Towel Ring Round 4.0 Each 935.1 3740.4 p) 600mm long CP towel rail 1.0 Each 1378.1 1378.1 q) 32mm Full Thread Waste Coupl 4.0 Each 492.2 1968.8 r) 450mm Braided hoses 4.0 Each 295.3 1181.2 s) Double coat hook 1.0 Each 836.7 836.7
6225mm dia brass or gun metal full way valve
6332mm dia brass or gun metal full way valve
6440mm dia brass or gun metal full way valve
6550mm dia brass or gun metal full way valve
6615mm dia CP Flange
6715mm dia CP Extention Nipple
68125mm CP grating
69Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000 Ltr Roto-moulded water storage tank (make-Syntex or equivalent) (3 layer)on the roof of First floor
70Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor. a) 110mm dia U-PVC SWR pipe 40.0 Mtr 496.3 19852.0 b) 75 mm dia UPVC SWR Pipe 10.0 Mtr 341.6 3416.0 c) 110mm U-PVC door tee 6.0 Each 386.0 2316.0 d) 110mm U-PVC Plain tee 4.0 Each 322.7 1290.8 e) 110mm U-PVC door bend 4.0 Each 293.6 1174.4 f) 110mm U-PVC plain bend 6.0 Each 232.0 1392.0 g) 110mm dia U-PVC 'P' trap 4.0 Each 497.3 1989.2 h) 110mm dia U-PVC Plain Shoe Bend 4.0 Each 232.0 928.0 i) 110mm dia U-PVC offset with out ear 4.0 Each 407.4 1629.6 j) 110mm dia U-PVC cowl 4.0 Each 58.2 232.8 k) 75 mm dia UPVC plain bend Pipe 4.0 Each 184.0 736.0 l) 76 mm dia UPVC plain Tee Pipe 6.0 Each 244.8 1468.8 m) PVC clamp suitable for 75 mm to 110mm dia pipe 20.0 Each 58.2 1164.0
71Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall
72Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge.
73Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. 580mmx440mm size Orissa pan.
74Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 Liters capacity PVC cistern with 32mm dia flush bend sleek fresh single flush Starwhite, Size 47.6 X 15.5 X 32.5 cm.
75Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm).
76Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal
7715mm dia urinal spreader
7832mm dia C.P. dome waste
79Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in charge. Table top basin.
80Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge.600mmx125mm size glass shelf with C.P gruard rail
81Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5m thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge. Design Mirror
82Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV (Eureka Forbes)of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge.
83Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm
84Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm
85Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm
86Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit
87Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. i) 110mm dia U-PVC Alround Concrete 30.0 Mtr 1336.0 40080.0 ii) 160mm dia U-PVC Alround Concrete 30.0 mtr 2159.3 64779.0 100 Users Brick Septic Tank-1 Nos
88Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
89- do - with addl. Depth of 1.5 m
90Excavation of foundation in ordinary soil within 50m initial lead and 1.5m initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge.
91Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge
92Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.
93Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
94Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
95Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge i) For Roof slab 9.288 sqm 773.39 7183.25 ii) For RCC wall 32.1 sqm 1090.97 35020.14
96Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
97Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
98Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
99Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
100Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
101Dewatering with 5 H.P diesel engine pump during excavation
102Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge160mm U-PVC plain Tee
103Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete.
104Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. i) 110mm diameter U-PVC SWR pipes 2.2 Mtr 496.3 1091.86 ii) 110mm U-PVC cowl 1.0 Each 58.2 58.2 Sinking of 200 mm dia (8\\") Gravel Packed Production Well including saline sealing where necessary through Rotary Drilling Rig 300 Mtrs with PVC/ GI Casing Pipes - 1 nos
105Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial soil strata by Mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer-in-Charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of finished bore suitable for lowering of 200 mm dia GI/PVC pipes for housing, fitted with socket and with or without well screen as per the necessity for the soft, medium, hard and boulder formation (GI/PVC casing pipes if required by the contractor to prevent collapse of over burden portion) including lower and withdrawing of casing pipe after drilling 200 mm to 450 mm dia in over burden portion. i) 00 mtrs. to 100 Mtrs. 50.0 Mtr 1720.3 86015.0 ii) 100 mtr. to 200 Mtrs 30.0 Mtr 2076.0 62280.0
106Supply of all labour & T&P for lowering the following size G.I./PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and slotted pipe and fixing all jointing materials etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fittings & jointing materials. i) 00 mtrs. to 300 Mtrs. 70.0 Mtr 114.7 8029.0
107Cleaning and developing the production well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge.
108Supplying all labour, tools and plant and grouting with cement bentonite slurry for saline sealing in the bore around the 200mm dia P.V.C. Casing pipe etc all complete as per the direction of the Engineer-in-Charge.
109Supplying all labour,T&P and materials for packing the bore with washed gravel (size P-6) around the pipes in good quality excluding cost of gravel etc complete as per the direction of the Engineer-in-Charge.
110Supplying all materials labour and T&P and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to 3 mtrs. Below ground level including cost of cement all complete as per the direction of Engineer-in-Charge
111Cost of 200 mm dia PVC Pipe
112Cost of cement
113Cost of sand 75m
114washed gravel
115Cutting slots in casing pipe
116Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. 1.50 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110 L.P.M with outlet dia of 25mm
117DOL controll pannel
1182.5 Sqmm flat cable
11932mm dia Steel short piece
120Steel roop with cover
121Well cap
12250mm size CI bracket
12320mm dia rigid UPVC pipe
12432mm Dia brass non return valve
12532mm dia HDPE pipe
126Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. TOTAL PH WORK (In Rs.)= 1242389.0 Electrical Works A INTERNAL ELECTRICAL WORK Sub-Head I (modular Wiring Items)
127Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked with 20 mm dia HMS FRLS PVC conduit ISI marked with 6A modular type (flame retradant type & antibactorial type) switch ISI marked and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type & antibactorial type) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge.N.B: 2way switch shall be used for living room for controlling room light and fan adjacent to bed. a) GROUP-A 50.0 Nos 621.0 31050.0 a-1) GROUP-B 17.0 Nos 924.0 15708.0 a-2) GROUP-C 17.0 Nos 1309.0 22253.0 b) Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type & antibactorial type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. (Maximum 02 nos point in one circuit). 8.0 Nos 196.0 1568.0 c) Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type & antibactorial type)) with suitable size modular box & cover( flame retradant type & antibactorial type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge (Maximum 02 nos point in one circuit). 18.0 Nos 554.0 9972.0 d) Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type & antibactorial type)) with suitable size modular box & cover(flame retradant type & antibactorial type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. 8.0 Nos 691.0 5528.0 e) Supplying,fixing of 2 nos 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type & antibactorial type)) with suitable size modular box & cover( flame retradant type & antibactorial type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. (Maximum 02 nos point in one circuit). 8.0 Nos 925.0 7400.0 f) Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant type & antibactorial type) with suitable size modular box & metallic cover plate (both side)( flame retradant type & antibactorial type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.(For equipement power)(Maximum 02 nos point in one circuit). 4.0 Nos 1232.0 4928.0 2.a) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) 195.0 Mtr 161.0 31395.0 b) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) 323.0 Mtr 175.0 56525.0 c) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) 320.0 Mtr 193.0 61760.0 d) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X6+1X2.5) 80.0 Mtr 224.0 17920.0 e) Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) 80.0 Mtr 321.0 25680.0 f) Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) 80.0 Mtr 448.0 35840.0
128Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover as required as per direction of Engg.-in-Charge.
129Supply and fixing of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge.
130Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure of suitable size as required as per direction of Engg.-in-Charge. B Sub-Head II (Light fitting Fixture & Fan)
131Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louversof exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge.
132Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge.
133Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge.(With fan Regulator)
134Supplying and fixing of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge.
135Supplying and fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs as required as per direction of Engg.-in-Charge.
136Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.
137SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having i/c connection etc as required as per direction of Engg.-in-Charge.
138SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge.
139Supply & fixing of 5watt Wall Decorative LIGHT opal glass with all accessories as per the direction of Engineer-in-charge.
140Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. C BDBS,DB,AC DB,FLOOR PANELS,MCBS
141Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar as per direction of Engg.-in-Charge. a) 4 Way(8+12+12) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door (for LDB, PDB) 4.0 Nos 8127.0 32508.0 b) Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) 4.0 Nos 1961.0 7844.0
142Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.
143Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.
144Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
145Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
146Supplying and fixing 63Amps 4P 415 volts MCB in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
147Supplying and fixing 63Amps 2P 240 volts RCCB 30 mA in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
148Supplying and fixing 40-63Amps 2P 240 volts AFDD(arc fault detection device),10KA,C,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
149Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time<25 nanosec in the incommer of Distribution board in the existing MCB DB with connections as per direction of Engg.-in-Charge.T(To be used in PDB,ACDB) D (Earthing) INSTALLATION
150Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
151Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. E CABLING AND END TERMINATION MAIN AREA
152Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade of following size cables as per direction of Engg.-in-Charge. 3.5core x 50 sq mm (main +DG) 244.0 Mtr 573.0 139812.0
153LAYING OF CABLE
154Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
155Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
156Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5core x 50 sq mm 4.0 Nos 426.0 1704.0
157Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. a) 50 mm dia 24.0 mtrs 449.0 10776.0 F MAIN CONTROL PANEL AT GF
158S/I/T&Commissioning of CPRI Approved LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type1+ 2 65 kA SPD shall be installed in the incomers.50x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication.Mandatory provision of cable alley is to be given. MAIN PANEL 1.0 Set 69800.0 69800.0 In commer-1-01 number of 125A(40%-100% I n rated) 4P Icu=100%Ics,16Ka LSIG MCCB with micro processor based release Fallowed by 3ph 10-60A KWH 440V Energy meter as provission.(FROM TRANSFORMER) In commer-2-01 number of 100A(40%-100% I n rated) 4P Icu=100%Ics,16kA MCCB with Thermal magnetic based release (DG INCOMMER) Changeover-1- 01 no of 100A 4P onload changeover switch ( DG 01 NO) Busbar-1&2 04 numbers of 200Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 3 numbers of 63A rating,10 KA breaking capacity,C series, 4P MCB Out going- 4 numbers of 32A rating,10 KA breaking capacity,C series, 2P MCB Out going- 3 numbers of 40A rating,10 KA breaking capacity,C series, 4P MCB Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data for incomerALL MCCB outgoing feeders shall have digital ammeter suitable rating class 1 CT as per feeder rating. 2 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB G CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER
159Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W). The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. H FIRE FIGHTING EXTINGUISHER SYSTEM
160Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge.
161Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete.
162Providing and Fixing of Mechanical Foam type fire extinguisher 9Lts. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket etc. complete, confirming to IS: 15683.
163Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 3 buckets) SIGNAGES
164SIGNAGES: SITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages I Lightning Protection
165Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.
166Supply of Lightning counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6 in complete as per the direction of Engineer in charge.
167Supply of Roof conductor holder for parapet- Polyamide Conductor holder. With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.
168Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561.
169Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).
170Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current.
171Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3. Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561.
172Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current .
173Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete.
174Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current.
175Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm.
176Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561.
177Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current.
178Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561.
179Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric.
180Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2.
181Supply of universal clamp made of SS to connect rod with flat conductor.
182Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested.
183Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system.
184Installation of The above arrangements including all accessories as per Direction of Engg. In charge. J UPS(COMMON+OT)
185Supply ,installation ,testing & commissioning of 5KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,240V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 16 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 3 years & compelete test certificate must be submitted along with ups including component list & SLD. K EXTERNAL ILLUMINATION
186Supplying, Erection, Fixing, connection & testing of LED with 40mm braket Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 60 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more. The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge.
187Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of maintenance free having G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.
188Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. L AIR CONDITIONER SPLIT Supply of A,C with indoor and outdoor unit
189Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 1.5 TR with 5 Star BEE Rating. 3.0 Each 48314.0 144942.0 REFRIGRANT PIPING
190Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C 33.0 mtr 838.0 27654.0 FRAME WORK
191Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C 3.0 no 1800.0 5400.0 DRAIN PIPING
192Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. 25mm nom. Dia pipe 33.0 mtr 152.0 5016.0 Supply and fixing of 4kVA Voltage stabilizer. 3.0 no 7952.0 23856.0 TOTAL ELECTRICAL WORK (In Rs.)= 2174922.0 ABSTRACT FOR CONSTRUCTION OF VETERINARY HOSPITALSAT SBVD- AMARDA, RASGOVINDPUR, MAYURBHANJ DISTRICT. Sl.No Description Of Item Qty Unit Rate Amount in Rs. Architectural Consultancy Services Architectural Consultancy Services 1.0 LS 88966.77 88966.77 Sub Total 88966.77 A CIVIL WORK i SBVD Building
193Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department as directed by the Engineer-In-Charge.
194Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works up to and including 1.5 metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
195Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth:consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.
196Carriage of earth by mechanical means with cost of all lead & lift upto 5 km including cost of all labour, T&P etc., comp. as directed by the Engineer-In-charge.
197Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer in charge. (Measurement will be taken on finished compacted section only)
198Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).
199Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 40 mm hard granite crusher broken metal), mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period .including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
200Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 25mm to 40 mm hard granite crusher broken metal) , mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period. including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
201Providing, lifting, hoisting and laying reinforced cement concrete of M-25 grade in following items as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes after curing of 28 days after mixing and test conducted in accordance with I.S. 516 using 10 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including centring,shuttering,hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. a) Footing. 27.48 Cum 7995.55 219717.85 b) Plinth beams 16.67 Cum 8879.94 148064.17 c) Roof Beam i) GF 16.67 Cum 17418.75 290440.24 ii) FF 9.535 Cum 19502.94 185960.49 iii) TF 1.85 Cum 24983.57 46169.63 d) Lintel i) GF 4.16 cum 15765.41 65552.57 ii) FF 2.66 cum 17518.59 46616.96 e) Chajja i) GF 11.81 Sqm 1347.67 15918.63 ii) FF 7.695 Sqm 1526.2 11744.14 iii) TF 2.025 Sqm 1996.19 4042.28 f) Roof slab i) GF 28.73 cum 15370.3 441650.16 ii) FF 11.99 cum 17044.44 204413.99 iii) TF 7.31 cum 21443.27 156793.2 g) Column i) GF 12.85 Cum 17418.75 223865.77 ii) FF 6.9 Cum 19502.94 134628.76 iii) TF 2.59 Cum 24983.57 64757.4 h) Staircase i) GF 3.76 cum 17270.63 64903.04 ii) FF 3.76 cum 19305.74 72550.98
202Providing, fixing and placing of Fe-500/ Tor steel (HYSD) for RCC work in lintel of required diameter with straightening, Cutting, bending, binding welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, taxes of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T & P and scaffolding complete in all respect as directed by the Engineer-in-Charge (payment will be made according to the actual weight of M.S rod /Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost) i) GF 144.16 Qntl 8907.26 1284069.98 ii) FF 49.38 Qntl 8941.36 441515.19 iii) TF 14.72 Qntl 9014.76 132715.23
203First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
204First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. i) GF 69.9 Cum 5813.07 406316.15 ii) FF 53.89 Cum 6199.1 334044.7 iii) TF 18.04 Cum 7153.5 129020.53
205First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
206Providing 16mm thick cement plaster with cement mortar of (1:6) to the brick surface including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc. complete as per direction of the Engineer-in-charge i) GF 468.23 Sqm 286.54 134168.11 ii) FF 285.14 Sqm 293.68 83740.23 iii) TF 19.7 Sqm 308.6 6078.77
207Providing 12mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. i) GF 435.49 Sqm 199.33 86805.62 ii) FF 274.31 Sqm 207.27 56857.07 iii) TF 19.005 Sqm 224.36 4263.98
208Providing 6mm thick cement plaster in all floors at all height with cement mortar of mix (1:4) to RCC surface finished smooth including deep chipping and slurry treatment with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. i) GF 243.8 Sqm 220.75 53818.99 ii) FF 95.95 Sqm 226.34 21717.34 iii) TF 58.5 Sqm 238.02 13924.07
209Providing and applying to inside,outside walls with one or more coats Priming coat with Cement Primer exterior grade of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. i) GF 1147.52 Sqm 81.81 93878.61 ii) FF 655.41 Sqm 83.86 54962.26 iii) TF 97.2 Sqm 88.14 8567.93
210Providing and applying to outside walls with two or more coats 100% Acrylic emulsion paint (1st quality) exterior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. i) GF 468.23 Sqm 98.69 46210.01 ii) FF 285.14 Sqm 102.39 29197.31 iii) TF 19.7 Sqm 110.37 2174.07
211Providing and applying to inside walls with two or more coats 100% Acrylic emulsion paint (1st quality) interior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding, Staging and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. i) GF 679.29 Sqm 105.6 71732.6 ii) FF 370.265 Sqm 107.8 39914.57 iii) TF 77.505 Sqm 112.45 8715.28
212Providing and applying white cement based putty interior grade of average thickness 1 mm of approved brand and manufacturer, over the inside plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. i) GF 679.29 Sqm 86.42 58703.9 ii) FF 655.41 Sqm 88.35 57908.03 iii) TF 97.2 Sqm 92.4 8981.35
213Supplying, fitting and fixing well dressed and well seasoned sal wood choukaths framed and fixed (wrought and put up) in trusses, purlines frames of doors, windows, ventilators and beams.of different length in proper position including two coats coats of coaltaring to wall and lintel side faces of choukaths including cost of coaltar and labour for coaltaring and fixing required nos. of W.I. clamps to the choukaths with approved qualities of screws including cost, conveyance, loading, sundries, T&P required for the work etc. complete in all respect with cost, conveyance, royalties, loading, unloading and taxes of all materials and cost of all labour, T&P, sundries, scaffolding etc. required for the work complete in all respect as per specification and direction of Engineer-In-Charge.
214Providing, fitting and fixing of approved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size, bothside finished with 1mm thk. laminate of approved colour & shade fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, i.e. hinges, door stopper, door buffer,Handle, Lock etc. of Godrej of equivalent approved make with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge at all floors and all heights.
215Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
216Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one side of shutter.
217Providing and fixing factory made uPVC white colour sliding glazed window/ventilator upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Twotrack two panels sliding window (Two nos. glazed ) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
218Providing and fixing M.S Grill/Gate of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply) at all floors and all heights.
219Providing & Painting 2 coats enamel paint (1st quality) of approved colour & brand on new work including cost of paint in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labour, etc. complete as per specification and direction of Engineer-In-Charge. i) GF 11.17 Sqm 187.87 2098.53 ii) FF 12.005 Sqm 192.39 2309.65
220Providing and laying Vitrified floor tiles 600x600/600x1200 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. i) GF 99.14 Sqm 1223.19 121271.71 ii) FF 85.2 Sqm 1236.91 105379.87
221Providing and laying Vitrified skirting tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. i) GF 12.1 Sqm 1470.0 17785.51 ii) FF 12.69 Sqm 1489.6 18898.59
222Providing and laying Matte Finish Vitrified floor tiles 300x300 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement:4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights.
223Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) minimum thickness 5mm of approved make in all colours, shades except burgundy, bottle green, black of size 300x200 in skirting and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete as per direction of EIC. In all floors and all heights .
224Providing and fixing 16mm thick Kota stone flooring (sample of Kota stone should be approved by Engineer-In-Charge) for floor and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. i) GF 153.77 Sqm 1275.8 196177.21 ii) FF 47.22 Sqm 1289.4 60881.6
225Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor at all floors and all heights. ========== TOTAL SBVD BUILDING (In Rs.) 8430877.0 ii SHED Building.:-
226Excavation of founation & all civil work in hard rock (granite) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per specification approved by the Department as directed by the Engineer-In-Charge.
227Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department as directed by the Engineer-In-charge.
228Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works up to and including 1.5 metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
229Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth:consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.
230Carriage of earth by mechanical means with cost of all lead & lift upto 5 km including cost of all labour, T&P etc., comp. as directed by the Engineer-In-charge.
231Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer in charge. (Measurement will be taken on finished compacted section only)
232Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).
233Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 40 mm hard granite crusher broken metal), mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period .including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
234Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 25mm to 40 mm hard granite crusher broken metal) , mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period. including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
235Providing, lifting, hoisting and laying reinforced cement concrete of M-25 grade in following items as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes after curing of 28 days after mixing and test conducted in accordance with I.S. 516 using 10 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including centring,shuttering,hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. a) Footing 7.75 Cum 7995.55 61957.56 b) Plinth beams 3.01 Cum 8879.94 26737.51 c) Roof Beam 3.87 Cum 17418.75 67445.4 d) Roof slab 5.715 cum 15370.3 87841.26 e) Column 3.46 Cum 17418.75 60199.2
236Providing, fixing and placing of Fe-500/ Tor steel (HYSD) for RCC work in lintel of required diameter of with straightening, Cutting, bending, binding welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, taxes of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T & P and scaffolding complete in all respect as directed by the Engineer-in-Charge (payment will be made according to the actual weight of M.S rod /Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost)
237First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement (PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
238First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
239Providing 16mm thick cement plaster with cement mortar of (1:6) to the brick surface including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc. complete as per direction of the Engineer-in-charge.
240Providing 12mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.
241Providing 6mm thick cement plaster in all floors at all height with cement mortar of mix (1:4) to RCC surface finished smooth including deep chipping and slurry treatment with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.
242Providing and applying to inside,outside walls with one or more coats Priming coat with Cement Primer exterior grade of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
243Providing and applying to outside walls with two or more coats 100% Acrylic emulsion paint (1st quality) exterior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
244Providing and applying to inside walls with two or more coats 100% Acrylic emulsion paint (1st quality) interior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding, Staging and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
245Providing and applying white cement based putty interior grade of average thickness 1 mm of approved brand and manufacturer, over the inside plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
246Providing and fixing 16mm thick Kota stone flooring (sample of Kota stone should be approved by Engineer-In-Charge) for floor and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.
247Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor at all floors and all heights. ========== TOTAL SHED BUILDING (In Rs). 868321.0 TOTAL CIVIL WORK 9299198.0 B P.H Work i. Internal & External PH
248Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer-in-charge. a 20mm Dia CPVC Pipe 6.0 Mtr 275.6 1653.6 b 25mm Dia CPVC pipe 15.0 Mtr 363.9 5458.5 c 25 mm dia PVC ASTM (Sch-80) pipe 10.0 Mtr 211.5 2115.0 d 32 mm dia PVC ASTM (Sch-80) pipe 8.0 Mtr 275.6 2204.8 e 40mm dia PVC ASTM (Sch-80) pipe 8.0 Mtr 361.1 2888.8 f 50mm dia PVC ASTM (Sch-80) pipe 6.0 Mtr 447.9 2687.4
249Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer-in-charge.250mm Thick Wall
250Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.
251Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.
252Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. a) 15mm dia long body Bib Cock cock 1.0 Each 1451.9 1451.9 b) 15mm dia CP S.B Bib cock 4.0 Each 1082.8 4331.2 c) 20mm dia CP concealed stop cock 1.0 Each 1378.1 1378.1 d) 15mm dia CP angle stop cock 16.0 Each 1673.3 26772.8 e) 15mm dia CP Pillar cock 6.0 Each 1624.1 9744.6 f) 15mm dia CP Health faucet 5.0 Each 1328.8 6644.0 g) 15mm dia Two way Bib Cock 5.0 Each 1255.0 6275.0 h) Shower Arm 1.0 Each 639.8 639.8 i) Over head shower 100mm dia round 1.0 Each 2116.3 2116.3 j) 32mm dia CP Bottle trap 3.0 Each 1747.2 5241.6 k) Auto closing concealed urinal flush valve 1.0 Each 2288.5 2288.5 l) 15mm dia CP SINK cock 2.0 Each 2067.1 4134.2 m) Soap Dispenser with glass bottle 5.0 Each 1328.8 6644.0 n) CP soap Dish holder 2.0 Each 1698.0 3396.0 o) Towel Ring Round 4.0 Each 935.1 3740.4 p) 600mm long CP towel rail 1.0 Each 1378.1 1378.1 q) 32mm Full Thread Waste Coupl 4.0 Each 492.2 1968.8 r) 450mm Braided hoses 4.0 Each 295.3 1181.2 s) Double coat hook 1.0 Each 836.7 836.7
25325mm dia brass or gun metal full way valve
25432mm dia brass or gun metal full way valve
25540mm dia brass or gun metal full way valve
25650mm dia brass or gun metal full way valve
25715mm dia CP Flange
25815mm dia CP Extention Nipple
259125mm CP grating
260Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000 Ltr Roto-moulded water storage tank (make-Syntex or equivalent) (3 layer)on the roof of First floor
261Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor. a) 110mm dia U-PVC SWR pipe 40.0 Mtr 496.3 19852.0 b) 75 mm dia UPVC SWR Pipe 10.0 Mtr 341.6 3416.0 c) 110mm U-PVC door tee 6.0 Each 386.0 2316.0 d) 110mm U-PVC Plain tee 4.0 Each 322.7 1290.8 e) 110mm U-PVC door bend 4.0 Each 293.6 1174.4 f) 110mm U-PVC plain bend 6.0 Each 232.0 1392.0 g) 110mm dia U-PVC 'P' trap 4.0 Each 497.3 1989.2 h) 110mm dia U-PVC Plain Shoe Bend 4.0 Each 232.0 928.0 i) 110mm dia U-PVC offset with out ear 4.0 Each 407.4 1629.6 j) 110mm dia U-PVC cowl 4.0 Each 58.2 232.8 k) 75 mm dia UPVC plain bend Pipe 4.0 Each 184.0 736.0 l) 76 mm dia UPVC plain Tee Pipe 6.0 Each 244.8 1468.8 m) PVC clamp suitable for 75 mm to 110mm dia pipe 20.0 Each 58.2 1164.0
262Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall
263Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge.
264Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. 580mmx440mm size Orissa pan.
265Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 Liters capacity PVC cistern with 32mm dia flush bend sleek fresh single flush Starwhite, Size 47.6 X 15.5 X 32.5 cm.
266Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm).
267Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in charge. Table top basin.
268Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge.600mmx125mm size glass shelf with C.P gruard rail
269Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5m thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge. Design Mirror
270Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV (Eureka Forbes)of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge.
271Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm
272Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm
273Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm
274Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit
275Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. i) 110mm dia U-PVC Alround Concrete 30.0 Mtr 1336.0 40080.0 ii) 160mm dia U-PVC Alround Concrete 30.0 mtr 2159.3 64779.0 25 Users Brick Septic Tank-1 Nos
276Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
277- do - with addl. Depth of 1.5 m
278Excavation of foundation in ordinary soil within 50m initial lead and 1.5m initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge.
279Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge
280Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.
281Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
282Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
283Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge i) For Roof slab 9.29 sqm 774.66 7194.26 ii) For RCC wall 32.1 sqm 1091.99 35052.88
284Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
285Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
286Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
287Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
288Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
289Dewatering with 5 H.P diesel engine pump during excavation
290Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge160mm U-PVC plain Tee
291Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete.
292Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. i) 110mm diameter U-PVC SWR pipes 2.2 Mtr 496.3 1091.86 ii) 110mm U-PVC cowl 1.0 Each 58.2 58.2 Sinking of 200 mm dia (8\\") Gravel Packed Production Well including saline sealing where necessary through Rotary Drilling Rig 300 Mtrs with PVC/ GI Casing Pipes - 1 nos
293Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial soil strata by Mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer-in-Charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of finished bore suitable for lowering of 200 mm dia GI/PVC pipes for housing, fitted with socket and with or without well screen as per the necessity for the soft, medium, hard and boulder formation (GI/PVC casing pipes if required by the contractor to prevent collapse of over burden portion) including lower and withdrawing of casing pipe after drilling 200 mm to 450 mm dia in over burden portion. i) 00 mtrs. to 100 Mtrs. 50.0 Mtr 1720.3 86015.0 ii) 100 mtr. to 200 Mtrs 30.0 Mtr 2076.0 62280.0
294Supply of all labour & T&P for lowering the following size G.I./PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and slotted pipe and fixing all jointing materials etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fittings & jointing materials. i) 00 mtrs. to 300 Mtrs. 70.0 Mtr 114.7 8029.0
295Cleaning and developing the production well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge.
296Supplying all labour, tools and plant and grouting with cement bentonite slurry for saline sealing in the bore around the 200mm dia P.V.C. Casing pipe etc all complete as per the direction of the Engineer-in-Charge.
297Supplying all labour,T&P and materials for packing the bore with washed gravel (size P-6) around the pipes in good quality excluding cost of gravel etc complete as per the direction of the Engineer-in-Charge.
298Supplying all materials labour and T&P and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to 3 mtrs. Below ground level including cost of cement all complete as per the direction of Engineer-in-Charge
299Cost of 200 mm dia PVC Pipe
300Cost of cement
301Cost of sand 75m
302washed gravel
303Cutting slots in casing pipe
304Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. 1.50 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110 L.P.M with outlet dia of 25mm
305DOL controll pannel
3062.5 Sqmm flat cable
30732mm dia Steel short piece
308Steel roop with cover
309Well cap
31050mm size CI bracket
31120mm dia rigid UPVC pipe
31232mm Dia brass non return valve
31332mm dia HDPE pipe
314Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. TOTAL PH WORK (In Rs.) = 1235418.0 Electrical Works A INTERNAL ELECTRICAL WORK Sub-Head I (modular Wiring Items)
315Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked with 20 mm dia HMS FRLS PVC conduit ISI marked with 6A modular type (flame retradant type & antibactorial type) switch ISI marked and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type & antibactorial type) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge.N.B: 2way switch shall be used for living room for controlling room light and fan adjacent to bed. a) GROUP-A 50.0 Nos 621.0 31050.0 a-1) GROUP-B 17.0 Nos 924.0 15708.0 a-2) GROUP-C 17.0 Nos 1309.0 22253.0 b) Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type & antibactorial type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. (Maximum 02 nos point in one circuit). 8.0 Nos 196.0 1568.0 c) Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type & antibactorial type)) with suitable size modular box & cover( flame retradant type & antibactorial type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge (Maximum 02 nos point in one circuit). 18.0 Nos 554.0 9972.0 d) Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type & antibactorial type)) with suitable size modular box & cover(flame retradant type & antibactorial type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. 8.0 Nos 691.0 5528.0 e) Supplying,fixing of 2 nos 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type & antibactorial type)) with suitable size modular box & cover( flame retradant type & antibactorial type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. (Maximum 02 nos point in one circuit). 8.0 Nos 925.0 7400.0 f) Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant type & antibactorial type) with suitable size modular box & metallic cover plate (both side)( flame retradant type & antibactorial type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.(For equipement power)(Maximum 02 nos point in one circuit). 4.0 Nos 1232.0 4928.0 2.a) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) 195.0 Mtr 161.0 31395.0 b) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) 323.0 Mtr 175.0 56525.0 c) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) 320.0 Mtr 193.0 61760.0 d) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X6+1X2.5) 80.0 Mtr 224.0 17920.0 e) Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) 80.0 Mtr 321.0 25680.0 f) Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) 80.0 Mtr 448.0 35840.0
316Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover as required as per direction of Engg.-in-Charge.
317Supply and fixing of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge.
318Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure of suitable size as required as per direction of Engg.-in-Charge. B Sub-Head II (Light fitting Fixture & Fan)
319Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louversof exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge.
320Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge.
321Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge.(With fan Regulator)
322Supplying and fixing of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge.
323Supplying and fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs as required as per direction of Engg.-in-Charge.
324Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.
325SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having i/c connection etc as required as per direction of Engg.-in-Charge.
326SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge.
327Supply & fixing of 5watt Wall Decorative LIGHT opal glass with all accessories as per the direction of Engineer-in-charge.
328Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. C BDBS,DB,AC DB,FLOOR PANELS,MCBS
329Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar as per direction of Engg.-in-Charge. a) 4 Way(8+12+12) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door (for LDB, PDB) 4.0 Nos 8127.0 32508.0 b) Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) 4.0 Nos 1961.0 7844.0
330Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.
331Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.
332Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
333Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
334Supplying and fixing 63Amps 4P 415 volts MCB in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
335Supplying and fixing 63Amps 2P 240 volts RCCB 30 mA in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
336Supplying and fixing 40-63Amps 2P 240 volts AFDD(arc fault detection device),10KA,C,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
337Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time<25 nanosec in the incommer of Distribution board in the existing MCB DB with connections as per direction of Engg.-in-Charge.T(To be used in PDB,ACDB) D (Earthing) INSTALLATION
338Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
339Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. E CABLING AND END TERMINATION MAIN AREA
340Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade of following size cables as per direction of Engg.-in-Charge. 3.5core x 50 sq mm (main +DG) 244.0 Mtr 573.0 139812.0
341LAYING OF CABLE
342Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
343Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
344Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5core x 50 sq mm 4.0 Nos 426.0 1704.0
345Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. a) 50 mm dia 24.0 mtrs 449.0 10776.0 F MAIN CONTROL PANEL AT GF
346S/I/T&Commissioning of CPRI Approved LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type1+ 2 65 kA SPD shall be installed in the incomers.50x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication.Mandatory provision of cable alley is to be given. MAIN PANEL 1.0 Set 69800.0 69800.0 In commer-1-01 number of 125A(40%-100% I n rated) 4P Icu=100%Ics,16Ka LSIG MCCB with micro processor based release Fallowed by 3ph 10-60A KWH 440V Energy meter as provission.(FROM TRANSFORMER) In commer-2-01 number of 100A(40%-100% I n rated) 4P Icu=100%Ics,16kA MCCB with Thermal magnetic based release (DG INCOMMER) Changeover-1- 01 no of 100A 4P onload changeover switch ( DG 01 NO) Busbar-1&2 04 numbers of 200Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 3 numbers of 63A rating,10 KA breaking capacity,C series, 4P MCB Out going- 4 numbers of 32A rating,10 KA breaking capacity,C series, 2P MCB Out going- 3 numbers of 40A rating,10 KA breaking capacity,C series, 4P MCB Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data for incomerALL MCCB outgoing feeders shall have digital ammeter suitable rating class 1 CT as per feeder rating. 2 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB G CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER
347Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W). The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. H FIRE FIGHTING EXTINGUISHER SYSTEM
348Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge.
349Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete.
350Providing and Fixing of Mechanical Foam type fire extinguisher 9Lts. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket etc. complete, confirming to IS: 15683.
351Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 3 buckets) SIGNAGES
352SIGNAGES: SITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages I Lightning Protection
353Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.
354Supply of Lightning counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6 in complete as per the direction of Engineer in charge.
355Supply of Roof conductor holder for parapet- Polyamide Conductor holder. With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.
356Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561.
357Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).
358Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current.
359Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3. Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561.
360Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current .
361Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete.
362Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current.
363Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm.
364Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561.
365Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current.
366Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561.
367Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric.
368Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2.
369Supply of universal clamp made of SS to connect rod with flat conductor.
370Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested.
371Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system.
372Installation of The above arrangements including all accessories as per Direction of Engg. In charge. J UPS(COMMON+OT)
373Supply ,installation ,testing & commissioning of 5KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,240V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 16 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 3 years & compelete test certificate must be submitted along with ups including component list & SLD. K EXTERNAL ILLUMINATION
374Supplying, Erection, Fixing, connection & testing of LED with 40mm braket Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 60 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more. The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge.
375Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of maintenance free having G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.
376Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. L AIR CONDITIONER SPLIT Supply of A,C with indoor and outdoor unit
377Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 1.5 TR with 5 Star BEE Rating. 3.0 Each 48314.0 144942.0 REFRIGRANT PIPING
378Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C 33.0 mtr 838.0 27654.0 FRAME WORK
379Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C 3.0 no 1800.0 5400.0 DRAIN PIPING
380Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. 25mm nom. Dia pipe 33.0 mtr 152.0 5016.0 Supply and fixing of 4kVA Voltage stabilizer. 3.0 no 7952.0 23856.0 TOTAL ELECTRICAL WORK (In Rs.)= 2174922.0 ABSTRACT FOR CONSTRUCTION OF VETERINARY HOSPITALSAT SBVD-CHANDUA, MAYURBHANJ DISTRICT. Sl.No Description Of Item Qty Unit Rate Amount in Rs. Architectural Consultancy Services Architectural Consultancy Services 1.0 LS 89172.01 89172.01 Sub Total 89172.01 A CIVIL WORK i SBVD Building
381Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department as directed by the Engineer-In-Charge.
382Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works up to and including 1.5 metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
383Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth:consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.
384Carriage of earth by mechanical means with cost of all lead & lift upto 5 km including cost of all labour, T&P etc., comp. as directed by the Engineer-In-charge.
385Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer in charge. (Measurement will be taken on finished compacted section only)
386Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).
387Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 40 mm hard granite crusher broken metal), mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period .including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
388Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 25mm to 40 mm hard granite crusher broken metal) , mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period. including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
389Providing, lifting, hoisting and laying reinforced cement concrete of M-25 grade in following items as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes after curing of 28 days after mixing and test conducted in accordance with I.S. 516 using 10 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including centring,shuttering,hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. a) Footing. 27.48 Cum 8013.31 220205.7 b) Plinth beams 16.674 Cum 8897.7 148360.18 c) Roof Beam i) GF 16.674 Cum 17436.5 290736.25 ii) FF 9.535 Cum 19520.69 186129.76 iii) TF 1.848 Cum 25001.32 46202.44 d) Lintel i) GF 4.158 cum 15783.16 65626.39 ii) FF 2.661 cum 17536.34 46664.2 e) Chajja i) GF 11.812 Sqm 1348.82 15932.26 ii) FF 7.695 Sqm 1527.36 11753.02 iii) TF 2.025 Sqm 1997.34 4044.62 f) Roof slab i) GF 28.734 cum 15388.05 442160.27 ii) FF 11.993 cum 17062.19 204626.9 iii) TF 7.312 cum 21461.02 156923.01 g) Column i) GF 12.852 Cum 17436.5 224093.93 ii) FF 6.903 Cum 19520.69 134751.31 iii) TF 2.592 Cum 25001.32 64803.42 h) Staircase i) GF 3.758 cum 17288.39 64969.76 ii) FF 3.758 cum 19323.49 72617.69
390Providing, fixing and placing of Fe-500/ Tor steel (HYSD) for RCC work in lintel of required diameter with straightening, Cutting, bending, binding welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, taxes of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T & P and scaffolding complete in all respect as directed by the Engineer-in-Charge (payment will be made according to the actual weight of M.S rod /Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost) i) GF 144.16 Qntl 8907.26 1284069.98 ii) FF 49.379 Qntl 8941.36 441515.19 iii) TF 14.722 Qntl 9014.76 132715.23
391First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
392First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. i) GF 69.897 Cum 5824.11 407087.82 ii) FF 53.886 Cum 6210.1 334637.45 iii) TF 18.036 Cum 7164.5 129218.92
393First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
394Providing 16mm thick cement plaster with cement mortar of (1:6) to the brick surface including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc. complete as per direction of the Engineer-in-charge i) GF 468.234 Sqm 287.25 134500.61 ii) FF 285.144 Sqm 294.39 83942.71 iii) TF 19.698 Sqm 309.31 6092.75
395Providing 12mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. i) GF 435.487 Sqm 199.92 87062.56 ii) FF 274.314 Sqm 207.86 57018.91 iii) TF 19.005 Sqm 224.95 4275.19
396Providing 6mm thick cement plaster in all floors at all height with cement mortar of mix (1:4) to RCC surface finished smooth including deep chipping and slurry treatment with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. i) GF 243.799 Sqm 221.05 53891.12 ii) FF 95.951 Sqm 226.63 21745.73 iii) TF 58.5 Sqm 238.31 13941.38
397Providing and applying to inside,outside walls with one or more coats Priming coat with Cement Primer exterior grade of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. i) GF 1147.52 Sqm 81.81 93878.61 ii) FF 655.409 Sqm 83.86 54962.26 iii) TF 97.203 Sqm 88.14 8567.93
398Providing and applying to outside walls with two or more coats 100% Acrylic emulsion paint (1st quality) exterior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. i) GF 468.234 Sqm 98.69 46210.01 ii) FF 285.144 Sqm 102.39 29197.31 iii) TF 19.698 Sqm 110.37 2174.07
399Providing and applying to inside walls with two or more coats 100% Acrylic emulsion paint (1st quality) interior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding, Staging and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. i) GF 679.286 Sqm 105.6 71732.6 ii) FF 370.265 Sqm 107.8 39914.57 iii) TF 77.505 Sqm 112.45 8715.28
400Providing and applying white cement based putty interior grade of average thickness 1 mm of approved brand and manufacturer, over the inside plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. i) GF 679.286 Sqm 86.42 58703.9 ii) FF 655.409 Sqm 88.35 57908.03 iii) TF 97.203 Sqm 92.4 8981.35
401Supplying, fitting and fixing well dressed and well seasoned sal wood choukaths framed and fixed (wrought and put up) in trusses, purlines frames of doors, windows, ventilators and beams.of different length in proper position including two coats coats of coaltaring to wall and lintel side faces of choukaths including cost of coaltar and labour for coaltaring and fixing required nos. of W.I. clamps to the choukaths with approved qualities of screws including cost, conveyance, loading, sundries, T&P required for the work etc. complete in all respect with cost, conveyance, royalties, loading, unloading and taxes of all materials and cost of all labour, T&P, sundries, scaffolding etc. required for the work complete in all respect as per specification and direction of Engineer-In-Charge.
402Providing, fitting and fixing of approved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size, bothside finished with 1mm thk. laminate of approved colour & shade fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, i.e. hinges, door stopper, door buffer,Handle, Lock etc. of Godrej of equivalent approved make with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge at all floors and all heights.
403Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
404Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one side of shutter.
405Providing and fixing factory made uPVC white colour sliding glazed window/ventilator upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Twotrack two panels sliding window (Two nos. glazed ) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
406Providing and fixing M.S Grill/Gate of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply) at all floors and all heights.
407Providing & Painting 2 coats enamel paint (1st quality) of approved colour & brand on new work including cost of paint in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labour, etc. complete as per specification and direction of Engineer-In-Charge. i) GF 11.17 Sqm 187.87 2098.53 ii) FF 12.005 Sqm 192.39 2309.65
408Providing and laying Vitrified floor tiles 600x600/600x1200 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. i) GF 99.144 Sqm 1224.02 121353.85 ii) FF 85.196 Sqm 1237.74 105450.45
409Providing and laying Vitrified skirting tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. i) GF 12.099 Sqm 1470.59 17792.67 ii) FF 12.687 Sqm 1490.19 18906.1
410Providing and laying Matte Finish Vitrified floor tiles 300x300 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement:4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights.
411Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) minimum thickness 5mm of approved make in all colours, shades except burgundy, bottle green, black of size 300x200 in skirting and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete as per direction of EIC. In all floors and all heights .
412Providing and fixing 16mm thick Kota stone flooring (sample of Kota stone should be approved by Engineer-In-Charge) for floor and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. i) GF 153.768 Sqm 1276.6 196300.23 ii) FF 47.217 Sqm 1290.2 60919.37
413Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor at all floors and all heights. ========== TOTAL SBVD BUILDING (In Rs.) 8443143.0 ii SHED Building.:-
414Excavation of founation & all civil work in hard rock (granite) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per specification approved by the Department as directed by the Engineer-In-Charge.
415Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department as directed by the Engineer-In-charge.
416Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works up to and including 1.5 metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
417Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth:consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.
418Carriage of earth by mechanical means with cost of all lead & lift upto 5 km including cost of all labour, T&P etc., comp. as directed by the Engineer-In-charge.
419Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer in charge. (Measurement will be taken on finished compacted section only)
420Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).
421Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 40 mm hard granite crusher broken metal), mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period .including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
422Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 25mm to 40 mm hard granite crusher broken metal) , mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period. including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
423Providing, lifting, hoisting and laying reinforced cement concrete of M-25 grade in following items as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes after curing of 28 days after mixing and test conducted in accordance with I.S. 516 using 10 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including centring,shuttering,hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. a) Footing 7.749 Cum 8013.31 62095.12 b) Plinth beams 3.011 Cum 8897.7 26790.96 c) Roof Beam 3.872 Cum 17436.5 67514.14 d) Roof slab 5.715 cum 15388.05 87942.71 e) Column 3.456 Cum 17436.5 60260.55
424Providing, fixing and placing of Fe-500/ Tor steel (HYSD) for RCC work in lintel of required diameter of with straightening, Cutting, bending, binding welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, taxes of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T & P and scaffolding complete in all respect as directed by the Engineer-in-Charge (payment will be made according to the actual weight of M.S rod /Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost)
425First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement (PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
426First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
427Providing 16mm thick cement plaster with cement mortar of (1:6) to the brick surface including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc. complete as per direction of the Engineer-in-charge.
428Providing 12mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.
429Providing 6mm thick cement plaster in all floors at all height with cement mortar of mix (1:4) to RCC surface finished smooth including deep chipping and slurry treatment with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.
430Providing and applying to inside,outside walls with one or more coats Priming coat with Cement Primer exterior grade of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
431Providing and applying to outside walls with two or more coats 100% Acrylic emulsion paint (1st quality) exterior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
432Providing and applying to inside walls with two or more coats 100% Acrylic emulsion paint (1st quality) interior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding, Staging and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
433Providing and applying white cement based putty interior grade of average thickness 1 mm of approved brand and manufacturer, over the inside plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
434Providing and fixing 16mm thick Kota stone flooring (sample of Kota stone should be approved by Engineer-In-Charge) for floor and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.
435Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor at all floors and all heights. ========== TOTAL SHED BUILDING (In Rs). 877051.0 TOTAL CIVIL WORKS 9320194.0 B P.H Work i. Internal & External PH
436Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer-in-charge. a 20mm Dia CPVC Pipe 6.0 Mtr 275.6 1653.6 b 25mm Dia CPVC pipe 15.0 Mtr 363.9 5458.5 c 25 mm dia PVC ASTM (Sch-80) pipe 10.0 Mtr 211.5 2115.0 d 32 mm dia PVC ASTM (Sch-80) pipe 8.0 Mtr 275.6 2204.8 e 40mm dia PVC ASTM (Sch-80) pipe 8.0 Mtr 361.1 2888.8 f 50mm dia PVC ASTM (Sch-80) pipe 6.0 Mtr 447.9 2687.4
437Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer-in-charge.250mm Thick Wall
438Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.
439Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.
440Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. a) 15mm dia long body Bib Cock cock 1.0 Each 1451.9 1451.9 b) 15mm dia CP S.B Bib cock 4.0 Each 1082.8 4331.2 c) 20mm dia CP concealed stop cock 1.0 Each 1378.1 1378.1 d) 15mm dia CP angle stop cock 16.0 Each 1673.3 26772.8 e) 15mm dia CP Pillar cock 6.0 Each 1624.1 9744.6 f) 15mm dia CP Health faucet 5.0 Each 1328.8 6644.0 g) 15mm dia Two way Bib Cock 5.0 Each 1255.0 6275.0 h) Shower Arm 1.0 Each 639.8 639.8 i) Over head shower 100mm dia round 1.0 Each 2116.3 2116.3 j) 32mm dia CP Bottle trap 3.0 Each 1747.2 5241.6 k) Auto closing concealed urinal flush valve 1.0 Each 2288.5 2288.5 l) 15mm dia CP SINK cock 2.0 Each 2067.1 4134.2 m) Soap Dispenser with glass bottle 5.0 Each 1328.8 6644.0 n) CP soap Dish holder 2.0 Each 1698.0 3396.0 o) Towel Ring Round 4.0 Each 935.1 3740.4 p) 600mm long CP towel rail 1.0 Each 1378.1 1378.1 q) 32mm Full Thread Waste Coupl 4.0 Each 492.2 1968.8 r) 450mm Braided hoses 4.0 Each 295.3 1181.2 s) Double coat hook 1.0 Each 836.7 836.7
44125mm dia brass or gun metal full way valve
44232mm dia brass or gun metal full way valve
44340mm dia brass or gun metal full way valve
44450mm dia brass or gun metal full way valve
44515mm dia CP Flange
44615mm dia CP Extention Nipple
447125mm CP grating
448Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000 Ltr Roto-moulded water storage tank (make-Syntex or equivalent) (3 layer)on the roof of First floor
449Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor. a) 110mm dia U-PVC SWR pipe 40.0 Mtr 496.3 19852.0 b) 75 mm dia UPVC SWR Pipe 10.0 Mtr 341.6 3416.0 c) 110mm U-PVC door tee 6.0 Each 386.0 2316.0 d) 110mm U-PVC Plain tee 4.0 Each 322.7 1290.8 e) 110mm U-PVC door bend 4.0 Each 293.6 1174.4 f) 110mm U-PVC plain bend 6.0 Each 232.0 1392.0 g) 110mm dia U-PVC 'P' trap 4.0 Each 497.3 1989.2 h) 110mm dia U-PVC Plain Shoe Bend 4.0 Each 232.0 928.0 i) 110mm dia U-PVC offset with out ear 4.0 Each 407.4 1629.6 j) 110mm dia U-PVC cowl 4.0 Each 58.2 232.8 k) 75 mm dia UPVC plain bend Pipe 4.0 Each 184.0 736.0 l) 76 mm dia UPVC plain Tee Pipe 6.0 Each 244.8 1468.8 m) PVC clamp suitable for 75 mm to 110mm dia pipe 20.0 Each 58.2 1164.0
450Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall
451Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge.
452Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. 580mmx440mm size Orissa pan.
453Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 Liters capacity PVC cistern with 32mm dia flush bend sleek fresh single flush Starwhite, Size 47.6 X 15.5 X 32.5 cm.
454Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm).
455Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal
45615mm dia urinal spreader
45732mm dia C.P. dome waste
458Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in charge. Table top basin.
459Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge.600mmx125mm size glass shelf with C.P gruard rail
460Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5m thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge. Design Mirror
461Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV (Eureka Forbes)of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge.
462Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm
463Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm
464Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm
465Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit
466Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. i) 110mm dia U-PVC Alround Concrete 30.0 Mtr 1336.0 40080.0 ii) 160mm dia U-PVC Alround Concrete 30.0 mtr 2159.3 64779.0 100 Users Brick Septic Tank-1 Nos
467Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
468- do - with addl. Depth of 1.5 m
469Excavation of foundation in ordinary soil within 50m initial lead and 1.5m initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge.
470Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge
471Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.
472Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
473Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
474Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge i) For Roof slab 9.287 sqm 774.66 7194.26 ii) For RCC wall 32.1 sqm 1091.99 35052.88
475Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
476Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
477Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
478Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
479Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
480Dewatering with 5 H.P diesel engine pump during excavation
481Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge160mm U-PVC plain Tee
482Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete.
483Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. i) 110mm diameter U-PVC SWR pipes 2.2 Mtr 496.3 1091.86 ii) 110mm U-PVC cowl 1.0 Each 58.2 58.2 Sinking of 200 mm dia (8\\") Gravel Packed Production Well including saline sealing where necessary through Rotary Drilling Rig 300 Mtrs with PVC/ GI Casing Pipes - 1 nos
484Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial soil strata by Mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer-in-Charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of finished bore suitable for lowering of 200 mm dia GI/PVC pipes for housing, fitted with socket and with or without well screen as per the necessity for the soft, medium, hard and boulder formation (GI/PVC casing pipes if required by the contractor to prevent collapse of over burden portion) including lower and withdrawing of casing pipe after drilling 200 mm to 450 mm dia in over burden portion. i) 00 mtrs. to 100 Mtrs. 50.0 Mtr 1720.3 86015.0 ii) 100 mtr. to 200 Mtrs 30.0 Mtr 2076.0 62280.0
485Supply of all labour & T&P for lowering the following size G.I./PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and slotted pipe and fixing all jointing materials etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fittings & jointing materials. i) 00 mtrs. to 300 Mtrs. 70.0 Mtr 114.7 8029.0
486Cleaning and developing the production well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge.
487Supplying all labour, tools and plant and grouting with cement bentonite slurry for saline sealing in the bore around the 200mm dia P.V.C. Casing pipe etc all complete as per the direction of the Engineer-in-Charge.
488Supplying all labour,T&P and materials for packing the bore with washed gravel (size P-6) around the pipes in good quality excluding cost of gravel etc complete as per the direction of the Engineer-in-Charge.
489Supplying all materials labour and T&P and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to 3 mtrs. Below ground level including cost of cement all complete as per the direction of Engineer-in-Charge
490Cost of 200 mm dia PVC Pipe
491Cost of cement
492Cost of sand 75m
493washed gravel
494Cutting slots in casing pipe
495Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. 1.50 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110 L.P.M with outlet dia of 25mm
496DOL controll pannel
4972.5 Sqmm flat cable
49832mm dia Steel short piece
499Steel roop with cover
500Well cap
50150mm size CI bracket
50220mm dia rigid UPVC pipe
50332mm Dia brass non return valve(Shakti make)
50432mm dia HDPE pipe
505Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. TOTAL PH WORK (In Rs.) = 1243743.0 Electrical Works A INTERNAL ELECTRICAL WORK Sub-Head I (modular Wiring Items)
506Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked with 20 mm dia HMS FRLS PVC conduit ISI marked with 6A modular type (flame retradant type & antibactorial type) switch ISI marked and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type & antibactorial type) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge.N.B: 2way switch shall be used for living room for controlling room light and fan adjacent to bed. a) GROUP-A 50.0 Nos 621.0 31050.0 a-1) GROUP-B 17.0 Nos 924.0 15708.0 a-2) GROUP-C 17.0 Nos 1309.0 22253.0 b) Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type & antibactorial type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. (Maximum 02 nos point in one circuit). 8.0 Nos 196.0 1568.0 c) Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type & antibactorial type)) with suitable size modular box & cover( flame retradant type & antibactorial type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge (Maximum 02 nos point in one circuit). 18.0 Nos 554.0 9972.0 d) Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type & antibactorial type)) with suitable size modular box & cover(flame retradant type & antibactorial type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. 8.0 Nos 691.0 5528.0 e) Supplying,fixing of 2 nos 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type & antibactorial type)) with suitable size modular box & cover( flame retradant type & antibactorial type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. (Maximum 02 nos point in one circuit). 8.0 Nos 925.0 7400.0 f) Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant type & antibactorial type) with suitable size modular box & metallic cover plate (both side)( flame retradant type & antibactorial type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.(For equipement power)(Maximum 02 nos point in one circuit). 4.0 Nos 1232.0 4928.0 2.a) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) 195.0 Mtr 161.0 31395.0 b) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) 323.0 Mtr 175.0 56525.0 c) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) 320.0 Mtr 193.0 61760.0 d) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X6+1X2.5) 80.0 Mtr 224.0 17920.0 e) Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) 80.0 Mtr 321.0 25680.0 f) Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) 80.0 Mtr 448.0 35840.0
507Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover as required as per direction of Engg.-in-Charge.
508Supply and fixing of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge.
509Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure of suitable size as required as per direction of Engg.-in-Charge. B Sub-Head II (Light fitting Fixture & Fan)
510Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louversof exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge.
511Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge.
512Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge.(With fan Regulator)
513Supplying and fixing of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge.
514Supplying and fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs as required as per direction of Engg.-in-Charge.
515Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.
516SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having i/c connection etc as required as per direction of Engg.-in-Charge.
517SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge.
518Supply & fixing of 5watt Wall Decorative LIGHT opal glass with all accessories as per the direction of Engineer-in-charge.
519Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. C BDBS,DB,AC DB,FLOOR PANELS,MCBS
520Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar as per direction of Engg.-in-Charge. a) 4 Way(8+12+12) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door (for LDB, PDB) 4.0 Nos 8127.0 32508.0 b) Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) 4.0 Nos 1961.0 7844.0
521Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.
522Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.
523Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
524Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
525Supplying and fixing 63Amps 4P 415 volts MCB in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
526Supplying and fixing 63Amps 2P 240 volts RCCB 30 mA in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
527Supplying and fixing 40-63Amps 2P 240 volts AFDD(arc fault detection device),10KA,C,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
528Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time<25 nanosec in the incommer of Distribution board in the existing MCB DB with connections as per direction of Engg.-in-Charge.T(To be used in PDB,ACDB) D (Earthing) INSTALLATION
529Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
530Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. E CABLING AND END TERMINATION MAIN AREA
531Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade of following size cables as per direction of Engg.-in-Charge. 3.5core x 50 sq mm (main +DG) 244.0 Mtr 573.0 139812.0
532LAYING OF CABLE
533Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
534Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
535Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5core x 50 sq mm 4.0 Nos 426.0 1704.0
536Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. a) 50 mm dia 24.0 mtrs 449.0 10776.0 F MAIN CONTROL PANEL AT GF
537S/I/T&Commissioning of CPRI Approved LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type1+ 2 65 kA SPD shall be installed in the incomers.50x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication.Mandatory provision of cable alley is to be given. MAIN PANEL 1.0 Set 69800.0 69800.0 In commer-1-01 number of 125A(40%-100% I n rated) 4P Icu=100%Ics,16Ka LSIG MCCB with micro processor based release Fallowed by 3ph 10-60A KWH 440V Energy meter as provission.(FROM TRANSFORMER) In commer-2-01 number of 100A(40%-100% I n rated) 4P Icu=100%Ics,16kA MCCB with Thermal magnetic based release (DG INCOMMER) Changeover-1- 01 no of 100A 4P onload changeover switch ( DG 01 NO) Busbar-1&2 04 numbers of 200Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 3 numbers of 63A rating,10 KA breaking capacity,C series, 4P MCB Out going- 4 numbers of 32A rating,10 KA breaking capacity,C series, 2P MCB Out going- 3 numbers of 40A rating,10 KA breaking capacity,C series, 4P MCB Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data for incomerALL MCCB outgoing feeders shall have digital ammeter suitable rating class 1 CT as per feeder rating. 2 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB G CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER
538Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W). The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. H FIRE FIGHTING EXTINGUISHER SYSTEM
539Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge.
540Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete.
541Providing and Fixing of Mechanical Foam type fire extinguisher 9Lts. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket etc. complete, confirming to IS: 15683.
542Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 3 buckets) SIGNAGES
543SIGNAGES: SITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages I Lightning Protection
544Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.
545Supply of Lightning counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6 in complete as per the direction of Engineer in charge.
546Supply of Roof conductor holder for parapet- Polyamide Conductor holder. With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.
547Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561.
548Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).
549Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current.
550Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3. Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561.
551Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current .
552Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete.
553Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current.
554Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm.
555Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561.
556Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current.
557Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561.
558Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric.
559Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2.
560Supply of universal clamp made of SS to connect rod with flat conductor.
561Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested.
562Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system.
563Installation of The above arrangements including all accessories as per Direction of Engg. In charge. J UPS(COMMON+OT)
564Supply ,installation ,testing & commissioning of 5KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,240V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 16 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 3 years & compelete test certificate must be submitted along with ups including component list & SLD. K EXTERNAL ILLUMINATION
565Supplying, Erection, Fixing, connection & testing of LED with 40mm braket Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 60 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more. The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge.
566Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of maintenance free having G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.
567Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. L AIR CONDITIONER SPLIT Supply of A,C with indoor and outdoor unit
568Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 1.5 TR with 5 Star BEE Rating. 3.0 Each 48314.0 144942.0 REFRIGRANT PIPING
569Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C 33.0 mtr 838.0 27654.0 FRAME WORK
570Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C 3.0 no 1800.0 5400.0 DRAIN PIPING
571Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. 25mm nom. Dia pipe 33.0 mtr 152.0 5016.0 Supply and fixing of 4kVA Voltage stabilizer. 3.0 no 7952.0 23856.0 TOTAL ELECTRICAL WORK (In Rs.)= 2174922.0 ABSTRACT FOR CONSTRUCTION OF VETERINARY HOSPITALSAT SBVD-KUNDABAI, UDALA, MAYURBHANJ DISTRICT. Sl.No Description Of Item Qty Unit Rate Amount in Rs. Architectural Consultancy Services Architectural Consultancy Services 1.0 LS 88907.1 88907.1 Sub Total 88907.1 A CIVIL WORK i SBVD Building
572Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department as directed by the Engineer-In-Charge.
573Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works up to and including 1.5 metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
574Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth:consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.
575Carriage of earth by mechanical means with cost of all lead & lift upto 5 km including cost of all labour, T&P etc., comp. as directed by the Engineer-In-charge.
576Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer in charge. (Measurement will be taken on finished compacted section only)
577Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).
578Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 40 mm hard granite crusher broken metal), mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period .including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
579Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 25mm to 40 mm hard granite crusher broken metal) , mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period. including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
580Providing, lifting, hoisting and laying reinforced cement concrete of M-25 grade in following items as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes after curing of 28 days after mixing and test conducted in accordance with I.S. 516 using 10 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including centring,shuttering,hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. a) Footing. 27.48 Cum 7886.0 216707.28 b) Plinth beams 16.674 Cum 8769.5 146222.64 c) Roof Beam i) GF 16.674 Cum 17302.85 288507.72 ii) FF 9.535 Cum 19384.96 184835.59 iii) TF 1.848 Cum 24861.59 45944.22 d) Lintel i) GF 4.158 cum 15646.71 65059.02 ii) FF 2.661 cum 17397.98 46296.02 e) Chajja i) GF 11.812 Sqm 1339.49 15822.06 ii) FF 7.695 Sqm 1517.81 11679.55 iii) TF 2.025 Sqm 1987.22 4024.12 f) Roof slab i) GF 28.734 cum 15251.31 438231.14 ii) FF 11.993 cum 16923.49 202963.42 iii) TF 7.312 cum 21317.14 155870.93 g) Column i) GF 12.852 Cum 17302.85 222376.23 ii) FF 6.903 Cum 19384.96 133814.38 iii) TF 2.592 Cum 24861.59 64441.24 h) Staircase i) GF 3.758 cum 17156.59 64474.47 ii) FF 3.758 cum 19190.73 72118.76
581Providing, fixing and placing of Fe-500/ Tor steel (HYSD) for RCC work in lintel of required diameter with straightening, Cutting, bending, binding welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, taxes of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T & P and scaffolding complete in all respect as directed by the Engineer-in-Charge (payment will be made according to the actual weight of M.S rod /Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost) i) GF 144.16 Qntl 8907.25 1284069.16 ii) FF 49.379 Qntl 8941.35 441514.92 iii) TF 14.722 Qntl 9014.75 132715.15
582First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
583First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. i) GF 69.897 Cum 5859.48 409560.07 ii) FF 53.886 Cum 6245.5 336545.01 iii) TF 18.036 Cum 7199.9 129857.4
584First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix (1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
585Providing 16mm thick cement plaster with cement mortar of (1:6) to the brick surface including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc. complete as per direction of the Engineer-in-charge i) GF 468.234 Sqm 286.17 133994.52 ii) FF 285.144 Sqm 293.31 83635.59 iii) TF 19.698 Sqm 308.23 6071.51
586Providing 12mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. i) GF 435.487 Sqm 199.03 86674.98 ii) FF 274.314 Sqm 206.97 56774.77 iii) TF 19.005 Sqm 224.06 4258.26
587Providing 6mm thick cement plaster in all floors at all height with cement mortar of mix (1:4) to RCC surface finished smooth including deep chipping and slurry treatment with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. i) GF 243.799 Sqm 220.43 53740.61 ii) FF 95.951 Sqm 226.02 21686.85 iii) TF 58.5 Sqm 237.7 13905.45
588Providing and applying to inside,outside walls with one or more coats Priming coat with Cement Primer exterior grade of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. i) GF 1147.52 Sqm 81.81 93878.61 ii) FF 655.409 Sqm 83.85 54956.04 iii) TF 97.203 Sqm 88.14 8567.47
589Providing and applying to outside walls with two or more coats 100% Acrylic emulsion paint (1st quality) exterior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. i) GF 468.234 Sqm 98.69 46210.01 ii) FF 285.144 Sqm 102.39 29195.89 iii) TF 19.698 Sqm 110.36 2173.87
590Providing and applying to inside walls with two or more coats 100% Acrylic emulsion paint (1st quality) interior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding, Staging and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. i) GF 679.286 Sqm 105.6 71732.6 ii) FF 370.265 Sqm 107.8 39914.57 iii) TF 77.505 Sqm 112.44 8714.66
591Providing and applying white cement based putty interior grade of average thickness 1 mm of approved brand and manufacturer, over the inside plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. i) GF 679.286 Sqm 86.42 58703.9 ii) FF 655.409 Sqm 88.35 57905.39 iii) TF 97.203 Sqm 92.39 8980.59
592Supplying, fitting and fixing well dressed and well seasoned sal wood choukaths framed and fixed (wrought and put up) in trusses, purlines frames of doors, windows, ventilators and beams.of different length in proper position including two coats coats of coaltaring to wall and lintel side faces of choukaths including cost of coaltar and labour for coaltaring and fixing required nos. of W.I. clamps to the choukaths with approved qualities of screws including cost, conveyance, loading, sundries, T&P required for the work etc. complete in all respect with cost, conveyance, royalties, loading, unloading and taxes of all materials and cost of all labour, T&P, sundries, scaffolding etc. required for the work complete in all respect as per specification and direction of Engineer-In-Charge.
593Providing, fitting and fixing of approved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size, bothside finished with 1mm thk. laminate of approved colour & shade fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, i.e. hinges, door stopper, door buffer,Handle, Lock etc. of Godrej of equivalent approved make with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge at all floors and all heights.
594Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
595Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one side of shutter.
596Providing and fixing factory made uPVC white colour sliding glazed window/ventilator upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Twotrack two panels sliding window (Two nos. glazed ) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
597Providing and fixing M.S Grill/Gate of required patterns for windows/verandahs etc. with M.S flats, square or round bars etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply) at all floors and all heights.
598Providing & Painting 2 coats enamel paint (1st quality) of approved colour & brand on new work including cost of paint in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labour, etc. complete as per specification and direction of Engineer-In-Charge. i) GF 11.17 Sqm 187.87 2098.51 ii) FF 12.005 Sqm 192.39 2309.64
599Providing and laying Vitrified floor tiles 600x600/600x1200 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. i) GF 99.144 Sqm 1217.52 120709.8 ii) FF 85.196 Sqm 1231.25 104897.58
600Providing and laying Vitrified skirting tiles 600x600 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights. i) GF 12.099 Sqm 1464.21 17715.48 ii) FF 12.687 Sqm 1483.81 18825.1
601Providing and laying Matte Finish Vitrified floor tiles 300x300 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement:4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights.
602Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) minimum thickness 5mm of approved make in all colours, shades except burgundy, bottle green, black of size 300x200 in skirting and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete as per direction of EIC. In all floors and all heights .
603Providing and fixing 16mm thick Kota stone flooring (sample of Kota stone should be approved by Engineer-In-Charge) for floor and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. i) GF 153.768 Sqm 1265.6 194608.78 ii) FF 47.217 Sqm 1279.2 60399.99
604Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor at all floors and all heights. 259.0 Sqm 457.85 118583.15 TOTAL SBVD BUILDING (In Rs.) = 8411966.0 ii SHED Building.:-
605Excavation of founation & all civil work in hard rock (granite) removed by chiselling including dressing and levelling the bed not exceeding 1.5m in depth and depositing the soil within initial lead of 50m and as per specification approved by the Department as directed by the Engineer-In-Charge.
606Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014cum in volume within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the department as directed by the Engineer-In-charge.
607Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works up to and including 1.5 metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge.
608Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth:consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge.
609Carriage of earth by mechanical means with cost of all lead & lift upto 5 km including cost of all labour, T&P etc., comp. as directed by the Engineer-In-charge.
610Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer in charge. (Measurement will be taken on finished compacted section only)
611Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).
612Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 40 mm hard granite crusher broken metal), mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period .including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
613Providing and laying of Cement Concrete of grade 1: 3 :6 (1cement : 3 sand : 6 graded stone aggregate of size 25mm to 40 mm hard granite crusher broken metal) , mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period. including all cost of labour ,material, conveyance,royalties and taxes ,sundries ,T & P etc.complete as per the directions of Engineer-in-charge.
614Providing, lifting, hoisting and laying reinforced cement concrete of M-25 grade in following items as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes after curing of 28 days after mixing and test conducted in accordance with I.S. 516 using 10 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including centring,shuttering,hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. a) Footing 7.749 Cum 7886.0 61108.61 b) Plinth beams 3.011 Cum 8769.5 26404.96 c) Roof Beam 3.872 Cum 17302.85 66996.64 d) Roof slab 5.715 cum 15251.31 87161.24 e) Column 3.456 Cum 17302.85 59798.65
615Providing, fixing and placing of Fe-500/ Tor steel (HYSD) for RCC work in lintel of required diameter of with straightening, Cutting, bending, binding welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, taxes of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T & P and scaffolding complete in all respect as directed by the Engineer-in-Charge (payment will be made according to the actual weight of M.S rod /Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost)
616First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement (PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
617First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge.
618Providing 16mm thick cement plaster with cement mortar of (1:6) to the brick surface including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing , sundries and T&P etc. complete as per direction of the Engineer-in-charge.
619Providing 12mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.
620Providing 6mm thick cement plaster in all floors at all height with cement mortar of mix (1:4) to RCC surface finished smooth including deep chipping and slurry treatment with screened and washed sharp sand for mortar and finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners, etc. complete with cost, conveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.
621Providing and applying to inside,outside walls with one or more coats Priming coat with Cement Primer exterior grade of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
622Providing and applying to outside walls with two or more coats 100% Acrylic emulsion paint (1st quality) exterior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
623Providing and applying to inside walls with two or more coats 100% Acrylic emulsion paint (1st quality) interior grade water proofing paint of approved make & shade manufactured by reputed manufacturer including scaffolding, Staging and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all Height & elevations including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete.
624Providing and applying white cement based putty interior grade of average thickness 1 mm of approved brand and manufacturer, over the inside plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete.
625Providing and fixing 16mm thick Kota stone flooring (sample of Kota stone should be approved by Engineer-In-Charge) for floor and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge & approved groove pattern etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.
626Providing and laying grading conc. 25 mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor at all floors and all heights. TOTAL SHED BUILDING (In Rs.) = 871650.0 TOTAL CIVIL WORKS 9283616.0 B P.H Work i. Internal & External PH
627Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer-in-charge. a 20mm Dia CPVC Pipe 6.0 Mtr 275.6 1653.6 b 25mm Dia CPVC pipe 15.0 Mtr 363.9 5458.5 c 25 mm dia PVC ASTM (Sch-80) pipe 10.0 Mtr 211.5 2115.0 d 32 mm dia PVC ASTM (Sch-80) pipe 8.0 Mtr 275.6 2204.8 e 40mm dia PVC ASTM (Sch-80) pipe 8.0 Mtr 361.1 2888.8 f 50mm dia PVC ASTM (Sch-80) pipe 6.0 Mtr 447.9 2687.4
628Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer-in-charge.250mm Thick Wall
629Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.
630Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.
631Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. a) 15mm dia long body Bib Cock cock 1.0 Each 1451.9 1451.9 b) 15mm dia CP S.B Bib cock 4.0 Each 1082.8 4331.2 c) 20mm dia CP concealed stop cock 1.0 Each 1378.1 1378.1 d) 15mm dia CP angle stop cock 16.0 Each 1673.3 26772.8 e) 15mm dia CP Pillar cock 6.0 Each 1624.1 9744.6 f) 15mm dia CP Health faucet 5.0 Each 1328.8 6644.0 g) 15mm dia Two way Bib Cock 5.0 Each 1255.0 6275.0 h) Shower Arm 1.0 Each 639.8 639.8 i) Over head shower 100mm dia round 1.0 Each 2116.3 2116.3 j) 32mm dia CP Bottle trap 3.0 Each 1747.2 5241.6 k) Auto closing concealed urinal flush valve 1.0 Each 2288.5 2288.5 l) 15mm dia CP SINK cock 2.0 Each 2067.1 4134.2 m) Soap Dispenser with glass bottle 5.0 Each 1328.8 6644.0 n) CP soap Dish holder 2.0 Each 1698.0 3396.0 o) Towel Ring Round 4.0 Each 935.1 3740.4 p) 600mm long CP towel rail 1.0 Each 1378.1 1378.1 q) 32mm Full Thread Waste Coupl 4.0 Each 492.2 1968.8 r) 450mm Braided hoses 4.0 Each 295.3 1181.2 s) Double coat hook 1.0 Each 836.7 836.7
63225mm dia brass or gun metal full way valve
63332mm dia brass or gun metal full way valve
63440mm dia brass or gun metal full way valve
63550mm dia brass or gun metal full way valve
63615mm dia CP Flange
63715mm dia CP Extention Nipple
638125mm CP grating
639Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000 Ltr Roto-moulded water storage tank (make-Syntex or equivalent) (3 layer)on the roof of First floor
640Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor. a) 110mm dia U-PVC SWR pipe 40.0 Mtr 496.3 19852.0 b) 75 mm dia UPVC SWR Pipe 10.0 Mtr 341.6 3416.0 c) 110mm U-PVC door tee 6.0 Each 386.0 2316.0 d) 110mm U-PVC Plain tee 4.0 Each 322.7 1290.8 e) 110mm U-PVC door bend 4.0 Each 293.6 1174.4 f) 110mm U-PVC plain bend 6.0 Each 232.0 1392.0 g) 110mm dia U-PVC 'P' trap 4.0 Each 497.3 1989.2 h) 110mm dia U-PVC Plain Shoe Bend 4.0 Each 232.0 928.0 i) 110mm dia U-PVC offset with out ear 4.0 Each 407.4 1629.6 j) 110mm dia U-PVC cowl 4.0 Each 58.2 232.8 k) 75 mm dia UPVC plain bend Pipe 4.0 Each 184.0 736.0 l) 76 mm dia UPVC plain Tee Pipe 6.0 Each 244.8 1468.8 m) PVC clamp suitable for 75 mm to 110mm dia pipe 20.0 Each 58.2 1164.0
641Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall
642Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge.
643Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. 580mmx440mm size Orissa pan.
644Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 Liters capacity PVC cistern with 32mm dia flush bend sleek fresh single flush Starwhite, Size 47.6 X 15.5 X 32.5 cm.
645Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm).
646Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal
64715mm dia urinal spreader
64832mm dia C.P. dome waste
649Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in charge. Table top basin.
650Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge.600mmx125mm size glass shelf with C.P gruard rail
651Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5m thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge. Design Mirror
652Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV (Eureka Forbes)of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge.
653Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm
654Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm
655Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm
656Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit
657Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. i) 110mm dia U-PVC Alround Concrete 30.0 Mtr 1336.0 40080.0 ii) 160mm dia U-PVC Alround Concrete 30.0 mtr 2159.3 64779.0 100 Users Brick Septic Tank-1 Nos
658Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
659- do - with addl. Depth of 1.5 m
660Excavation of foundation in ordinary soil within 50m initial lead and 1.5m initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge.
661Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge
662Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.
663Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
664Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
665Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge i) For Roof slab 9.287 sqm 773.67 7185.07 ii) For RCC wall 32.1 sqm 1091.2 35027.52
666Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
667Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
668Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
669Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
670Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
671Dewatering with 5 H.P diesel engine pump during excavation
672Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge160mm U-PVC plain Tee
673Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete.
674Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. i) 110mm diameter U-PVC SWR pipes(Supreme/Ashirvad) 2.203 Mtr 496.3 1093.35 ii) 110mm U-PVC cowl 1.0 Each 58.2 58.2 Sinking of 200 mm dia (8\\") Gravel Packed Production Well including saline sealing where necessary through Rotary Drilling Rig 300 Mtrs with PVC/ GI Casing Pipes - 1 nos
675Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial soil strata by Mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer-in-Charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of finished bore suitable for lowering of 200 mm dia GI/PVC pipes for housing, fitted with socket and with or without well screen as per the necessity for the soft, medium, hard and boulder formation (GI/PVC casing pipes if required by the contractor to prevent collapse of over burden portion) including lower and withdrawing of casing pipe after drilling 200 mm to 450 mm dia in over burden portion. i) 00 mtrs. to 100 Mtrs. 50.0 Mtr 1720.3 86015.0 ii) 100 mtr. to 200 Mtrs 30.0 Mtr 2076.0 62280.0
676Supply of all labour & T&P for lowering the following size G.I./PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and slotted pipe and fixing all jointing materials etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fittings & jointing materials. i) 00 mtrs. to 300 Mtrs. 70.0 Mtr 114.7 8029.0
677Cleaning and developing the production well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge.
678Supplying all labour, tools and plant and grouting with cement bentonite slurry for saline sealing in the bore around the 200mm dia P.V.C. Casing pipe etc all complete as per the direction of the Engineer-in-Charge.
679Supplying all labour,T&P and materials for packing the bore with washed gravel (size P-6) around the pipes in good quality excluding cost of gravel etc complete as per the direction of the Engineer-in-Charge.
680Supplying all materials labour and T&P and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to 3 mtrs. Below ground level including cost of cement all complete as per the direction of Engineer-in-Charge
681Cost of 200 mm dia PVC Pipe
682Cost of cement
683Cost of sand 75m
684washed gravel
685Cutting slots in casing pipe
686Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. 1.50 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110 L.P.M with outlet dia of 25mm
687DOL controll pannel
6882.5 Sqmm flat cable
68932mm dia Steel short piece
690Steel roop with cover
691Well cap
69250mm size CI bracket
69320mm dia rigid UPVC pipe
69432mm Dia brass non return valve(Shakti make)
69532mm dia HDPE pipe
696Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. TOTAL PH WORK (In Rs.)= 1242476.0 Electrical Works A INTERNAL ELECTRICAL WORK Sub-Head I (modular Wiring Items)
697Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked with 20 mm dia HMS FRLS PVC conduit ISI marked with 6A modular type (flame retradant type & antibactorial type) switch ISI marked and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retradant type & antibactorial type) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge.N.B: 2way switch shall be used for living room for controlling room light and fan adjacent to bed. a) GROUP-A 50.0 Nos 621.0 31050.0 a-1) GROUP-B 17.0 Nos 924.0 15708.0 a-2) GROUP-C 17.0 Nos 1309.0 22253.0 b) Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type & antibactorial type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. (Maximum 02 nos point in one circuit). 8.0 Nos 196.0 1568.0 c) Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type & antibactorial type)) with suitable size modular box & cover( flame retradant type & antibactorial type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge (Maximum 02 nos point in one circuit). 18.0 Nos 554.0 9972.0 d) Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type & antibactorial type)) with suitable size modular box & cover(flame retradant type & antibactorial type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. 8.0 Nos 691.0 5528.0 e) Supplying,fixing of 2 nos 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)( (flame retradant type & antibactorial type)) with suitable size modular box & cover( flame retradant type & antibactorial type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. (Maximum 02 nos point in one circuit). 8.0 Nos 925.0 7400.0 f) Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant type & antibactorial type) with suitable size modular box & metallic cover plate (both side)( flame retradant type & antibactorial type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.(For equipement power)(Maximum 02 nos point in one circuit). 4.0 Nos 1232.0 4928.0 2.a) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) 195.0 Mtr 161.0 31395.0 b) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) 323.0 Mtr 175.0 56525.0 c) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) 320.0 Mtr 193.0 61760.0 d) Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X6+1X2.5) 80.0 Mtr 224.0 17920.0 e) Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) 80.0 Mtr 321.0 25680.0 f) Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable in recessed HMS FRLS PVC conduit of mentioned size as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) 80.0 Mtr 448.0 35840.0
698Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover as required as per direction of Engg.-in-Charge.
699Supply and fixing of Bakelite angle holder/batten holder of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge.
700Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure of suitable size as required as per direction of Engg.-in-Charge. B Sub-Head II (Light fitting Fixture & Fan)
701Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louversof exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge.
702Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge.
703Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge.(With fan Regulator)
704Supplying and fixing of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge.
705Supplying and fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs as required as per direction of Engg.-in-Charge.
706Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.
707SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having i/c connection etc as required as per direction of Engg.-in-Charge.
708SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge.
709Supply & fixing of 5watt Wall Decorative LIGHT opal glass with all accessories as per the direction of Engineer-in-charge.
710Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. C BDBS,DB,AC DB,FLOOR PANELS,MCBS
711Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar as per direction of Engg.-in-Charge. a) 4 Way(8+12+12) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door (for LDB, PDB) 4.0 Nos 8127.0 32508.0 b) Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) 4.0 Nos 1961.0 7844.0
712Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.
713Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.
714Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
715Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
716Supplying and fixing 63Amps 4P 415 volts MCB in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
717Supplying and fixing 63Amps 2P 240 volts RCCB 30 mA in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
718Supplying and fixing 40-63Amps 2P 240 volts AFDD(arc fault detection device),10KA,C,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
719Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time<25 nanosec in the incommer of Distribution board in the existing MCB DB with connections as per direction of Engg.-in-Charge.T(To be used in PDB,ACDB) D (Earthing) INSTALLATION
720Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
721Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. E CABLING AND END TERMINATION MAIN AREA
722Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade of following size cables as per direction of Engg.-in-Charge. 3.5core x 50 sq mm (main +DG) 244.0 Mtr 573.0 139812.0
723LAYING OF CABLE
724Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
725Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
726Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5core x 50 sq mm 4.0 Nos 426.0 1704.0
727Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. a) 50 mm dia 24.0 mtrs 449.0 10776.0 F MAIN CONTROL PANEL AT GF
728S/I/T&Commissioning of CPRI Approved LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type1+ 2 65 kA SPD shall be installed in the incomers.50x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication.Mandatory provision of cable alley is to be given. MAIN PANEL 1.0 Set 69800.0 69800.0 In commer-1-01 number of 125A(40%-100% I n rated) 4P Icu=100%Ics,16Ka LSIG MCCB with micro processor based release Fallowed by 3ph 10-60A KWH 440V Energy meter as provission.(FROM TRANSFORMER) In commer-2-01 number of 100A(40%-100% I n rated) 4P Icu=100%Ics,16kA MCCB with Thermal magnetic based release (DG INCOMMER) Changeover-1- 01 no of 100A 4P onload changeover switch ( DG 01 NO) Busbar-1&2 04 numbers of 200Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 3 numbers of 63A rating,10 KA breaking capacity,C series, 4P MCB Out going- 4 numbers of 32A rating,10 KA breaking capacity,C series, 2P MCB Out going- 3 numbers of 40A rating,10 KA breaking capacity,C series, 4P MCB Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data for incomerALL MCCB outgoing feeders shall have digital ammeter suitable rating class 1 CT as per feeder rating. 2 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB G CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER
729Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W). The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. H FIRE FIGHTING EXTINGUISHER SYSTEM
730Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge.
731Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete.
732Providing and Fixing of Mechanical Foam type fire extinguisher 9Lts. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket etc. complete, confirming to IS: 15683.
733Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 3 buckets) SIGNAGES
734SIGNAGES: SITC flexyl of Photoluminescent based Glow-in-the-dark sheeting with luminious properties enclosed in a weather-proof UV stabilized film with UV screen printing by imported inks pasted over 3 mm Thick Cast Acrylic Sheet with the Protection of 3 mm Thick Cast Acrylic from Front side with stud type mirror screw with lifespan of 5 years, visible upto 4-6 hrs in total darkness for floor indication, fire exit, hydrant, hose reel, fire extinguisher, MCP, fire alarm panel, in case of fire, lift, alarm valve signages I Lightning Protection
735Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.
736Supply of Lightning counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6 in complete as per the direction of Engineer in charge.
737Supply of Roof conductor holder for parapet- Polyamide Conductor holder. With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.
738Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561.
739Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).
740Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current.
741Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3. Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561.
742Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current .
743Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete.
744Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current.
745Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm.
746Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561.
747Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current.
748Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561.
749Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric.
750Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2.
751Supply of universal clamp made of SS to connect rod with flat conductor.
752Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested.
753Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system.
754Installation of The above arrangements including all accessories as per Direction of Engg. In charge. J UPS(COMMON+OT)
755Supply ,installation ,testing & commissioning of 5KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,240V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 16 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 3 years & compelete test certificate must be submitted along with ups including component list & SLD. K EXTERNAL ILLUMINATION
756Supplying, Erection, Fixing, connection & testing of LED with 40mm braket Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 60 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more. The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge.
757Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of maintenance free having G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.
758Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. L AIR CONDITIONER SPLIT Supply of A,C with indoor and outdoor unit
759Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 1.5 TR with 5 Star BEE Rating. 3.0 Each 48314.0 144942.0 REFRIGRANT PIPING
760Supply,installation of hard/soft ISI marked copper refrigerant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C 33.0 mtr 838.0 27654.0 FRAME WORK
761Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C 3.0 no 1800.0 5400.0 DRAIN PIPING
762Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. 25mm nom. Dia pipe 33.0 mtr 152.0 5016.0 Supply and fixing of 4kVA Voltage stabilizer. 3.0 no 7952.0 23856.0 TOTAL ELECTRICAL WORK (In Rs.)= 2174922.0 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58714051
AUTHORITY Government Departments
TENDER VALUE 5.11 Crore
LAST DATE 09-12-2026
Authority
Authority Name Engineering Projects India Limited
Work Description Tender for Tender For Construction Of Sub-Block Veterinary Dispensary Building At Sankerko, Amarda, Chandua And Kundabai Various Locations In The District Of Mayurbhanj, Odisha Including Architectural Consultancy Services
Basic Detail
Tender No EPI/PCO/BBSR/1059/273
Bidding Type Tender
Location
City Mayurbhanj
State Odisha
Key Dates
Publish Date 26 Nov 2026
Submission Date 09 Dec 2026
Open Date 01 Jan 0001
Finance
Tender Value 5.11 Crore
Tender Fee 5900
EMD 10.23 Lakhs
Exemption Available
Document List
BOQ_623979.xls
c24ef241-8d72-40e3-a95f-4c32d2365cdf.html
TenderDoc273.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 09, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 11 days
Dec 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_623979.xls

html

c24ef241-8d72-40e3-a95f-4c32d2365cdf.html

pdf

TenderDoc273.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender