Bids Are invited for Tender 19 Cooling System And Power Backup
Tender Overview
Project Description
Bids Are invited for Air Conditioner 1.5Ton 5 Star - 1 Point 5 Tr 5 Star Inverter Split Air Conditioner Branded Blue Star Daikin Voltas Hitachi Or Equivalent Wall Mounted Tonnage Per 02 Load Calculation , Auto Changerover Controller - Dual Ac Sequencing Controller With Timed Alternation And Failure Changeover , Installation And Commissioning - Mounting Copper Piping Drainage Electrical Connection Gas Charging And Commissioning For 2 Units , Online Ups Floor-Standing - Online Double Conversion Ups Single Phase Tower Floor Standing Form Factor Not Rack Mounted Capacity Per 02 Load Calculation , Ups Battery Bank With Open Stand - 8 X 12 V Smf Vrla Blocks In Series Ah Per 02 Load Calculation Mounted On An Open Battery Rack Or Stand With Clearance And Ventilation Not Inside The Equipment Rack , Standby Generator - Silent Acoustic Canopy Diesel Generating Set Cpcb Iv Plus Compliant With Amf Panel Capacity Per 02 Load Calculation , Electrical Work And Earthing - Dedicated Distribution Board Isolators Cabling From Source To Rack And To The Ups Position Dedicated Earth Pit And Earthing Conductor Ups Input And Output Wiring Physical Separation Of Ups Backed And Non Ups Circuits Installation And Commissioning
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Air Conditioner 1.5Ton 5 Star | 1 point 5 TR 5 star inverter split air conditioner branded Blue Star Daikin Voltas Hitachi or equivalent wall mounted tonnage per 02 Load Calculation |
| 2 | Auto Changerover Controller | Dual AC sequencing controller with timed alternation and failure changeover |
| 3 | Installation and commissioning | Mounting copper piping drainage electrical connection gas charging and commissioning for 2 units |
| 4 | Online UPS floor-standing | Online double conversion UPS single phase TOWER FLOOR STANDING form factor NOT rack mounted capacity per 02 Load Calculation |
| 5 | UPS Battery Bank with open stand | 8 x 12 V SMF VRLA blocks in series Ah per 02 Load Calculation mounted on an open battery rack or stand with clearance and ventilation NOT inside the equipment rack |
| 6 | Standby generator | Silent acoustic canopy diesel generating set CPCB IV plus compliant with AMF panel capacity per 02 Load Calculation |
| 7 | Electrical Work and earthing | Dedicated distribution board isolators cabling from source to rack and to the UPS position dedicated earth pit and earthing conductor UPS input and output wiring physical separation of UPS backed and non UPS circuits installation and commissioning |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender