Tender For Commissioning And Development Of Existing Non-Functional Source Under Sub Division Falna And Sadri (On Revised Phed Bsr 2023-24 Exclusive Of Gst (1.04.2026))
Tender Value
70 Lakhs
Estimated cost
Bid Submission
11 Dec 2026
12 days left
EMD
1.40 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pali → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Commissioning And Development Of Existing Non-Functional Source Under Sub Division Falna And Sadri (On Revised Phed Bsr 2023-24 Exclusive Of Gst (1.04.2026))
BOQ
| Sl. No. | Item Description |
| 1 | Providing & laying ISI marked GI Pipe Light duty ( “A” class) as per IS: 1239 for casing pipe for submersible cable external work 40 mm dia complete in all respect.Rate is exclusive of GST. |
| 2 | Deepening of existing tube well by DTH system beyond existing depth up to 100 mtr. and above in all type of rocks including flushing of tube well and obtaining sand free water. Rates are exclusive of GST.Nominal bore 150 mm dia. |
| 3 | Nominal bore 200 mm dia. |
| 4 | Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as per amended up to date.Rate is exclusive of GST. |
| 5 | Supplying & Packing P-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-1) 1991 or as per amended up to date.Rate is exclusive of GST. |
| 6 | Development of tube well having depth up to 250 mtr as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable methods to give sand free water for required yield of the gravel packed tube well.Rate is exclusive of GST. |
| 7 | Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.Rates are exclusive of GST. |
| 8 | Up to 2.0 KW |
| 9 | Above 2.0 KW |
| 10 | Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.Rates are exclusive of GST. |
| 11 | Up to 5.5 KW (7.5 HP) & head up to 120 mtr. |
| 12 | Up to 5.5 KW (7.5 HP) & head above 120 mtr. |
| 13 | 7.5 KW (10 HP) & head up to 120 mtr. |
| 14 | 7.5 KW (10 HP) & head above 120 mtr. |
| 15 | 9.3 KW (12.5 HP) & head up to 120 mtr. |
| 16 | 9.3 KW (12.5 HP) & head above 120 mtr. |
| 17 | 11 KW (15 HP) & head up to 120 mtr. |
| 18 | 11 KW (15 HP) & head above 120 mtr. |
| 19 | 13 KW (17.5 HP) & head up to 120 mtr. |
| 20 | 13 KW (17.5 HP) & head above 120 mtr. |
| 21 | 15 KW (20 HP) and above, head up to 120 mtr. |
| 22 | 15 KW (20 HP) and above, head above 120 mtr. |
| 23 | Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply.Rate is exclusive of GST. |
| 24 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.Rate is exclusive of GST. |
| 25 | Up to 5.00 HP |
| 26 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.Rates are exclusive of GST. |
| 27 | Above 5 HP and up to 10 HP |
| 28 | Above 10 HP and up to 15 HP |
| 29 | Above 15 HP and up to 20 HP |
| 30 | Above 20 HP and up to 30 HP |
| 31 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. Rates are exclusive of GST. |
| 32 | 3 core 4.0 Sq.mm |
| 33 | 3 core 6.0 Sq.mm |
| 34 | 3 core 10.0 Sq.mm |
| 35 | 3 core 16.0 Sq.mm |
| 36 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. Rates are exclusive of GST. |
| 37 | 10.0 Sq.mm, 4 core |
| 38 | 16.0 Sq.mm, 4 core |
| 39 | 25.0 Sq.mm, 3.5 core |
| 40 | 35.0 Sq.mm, 3.5 core |
| 41 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. Rate is exclusive of GST. |
| 42 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.Rate is exclusive of GST. |
| 43 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.Rates are exclusive of GST. |
| 44 | 125 mm dia |
| 45 | 150 mm dia |
| 46 | 200 mm dia |
| 47 | 250 mm dia |
| 48 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.Rates are exclusive of GST. |
| 49 | 32 mm dia |
| 50 | 50 mm dia |
| 51 | 65 mm dia |
| 52 | 80mm dia |
| 53 | Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect.Rates are exclusive of GST. |
| 54 | 40 mm dia |
| 55 | 50 mm dia |
| 56 | 63 mm dia |
| 57 | 75 mm dia |
| 58 | 90 mm dia |
| 59 | Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.Rates are exclusive of GST. |
| 60 | 50 mm dia |
| 61 | 65 mm dia |
| 62 | 80 mm dia |
| 63 | Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.Rate is exclusive of GST. |
| 64 | Providing and Fixing of ISI marked PVC storage tank of following capacity as per IS: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long GI overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket, including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and PVC ball complete with brass weight 1000 gm, including P&F 15mm dia CI quarter turn heavy duty Bib Cocks four no's of superior quality and approved make, including interconnections complete job.Rates are exclusive of GST. |
| 65 | 1000 litres capacity |
| 66 | 2000 litres capacity |
| 67 | Fabrication & Fixing M.S. Stand of specified class of angle iron L-shaped of 50 mm size with four legs grouted by 300*300*300 mm CC Block M-15 in the ground and all legs tied up with each other through same size of angle iron along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. PVC tank complete in all respect.Rate is exclusive of GST. |
| 68 | Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizesRates are exclusive of GST. |
| 69 | 65 mm dia |
| 70 | 80 mm dia |
| 71 | Proving and Fixing 32 mm dia Full way valve or wheel valve as per IS:778 or amended up to date of approved make, on pump delivery pipe.Rate is exclusive of GST. |
| 72 | Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover.Rate is exclusive of GST. |
| 73 | Construction of bore hole for shallow depth tube well from ground level to required depth for following size for all type of relevant strata by percussion/ rotary drilling/ hand boring method excluding cost of casing pipe. The bore hole should be as per nominal bore of PVC casing pipe. The work will be complete after obtaining sand free water. Rates are exclusive of GST. |
| 74 | 125 mm dia nominal bore |
| 75 | 150 mm dia nominal bore |
| 76 | 200 mm dia nominal bore |
| 77 | 250 mm dia nominal bore |
| 78 | Providing and Lowering of ISI mark PVC-U casing and screen pipe as per IS : 12818 : 2010 or amended up to date having pipe thickness as per IS code suitable for TW and DCB with threading , winding with superior quality of plastic mesh & rope in three layers with end cap complete as per technical specification and direction of Engineer In charge.Rates are exclusive of GST. |
| 79 | Shallow well casing pipe (CS) suitable for depth up to 80 mtr. |
| 80 | 150 mm nominal dia ( internal dia ). |
| 81 | 200 mm nominal dia ( internal dia ). |
| 82 | 250 mm nominal dia ( internal dia ). |
| 83 | Medium well casing pipe (CM) suitable for depth above 80 mtr and up to 250 mtr. |
| 84 | 100 mm nominal dia ( internal dia ) |
| 85 | 125 mm nominal dia ( internal dia ) |
| 86 | 150 mm nominal dia ( internal dia ) |
| 87 | 200 mm nominal dia ( internal dia ) |
| 88 | 250 mm nominal dia ( internal dia ) |
| 89 | Supply of ISI mark AC pressure pipe class 15 manufactured by MAZZA process as per IS:1592-2003 or amended up to date, for casing of tube well for following dia nominal bore, with jointing material PVC coupler as per technical specification and direction of Engineer In charge. Rates are exclusive of GST. |
| 90 | 125 mm nominal dia |
| 91 | 150 mm nominal dia |
| 92 | 200 mm nominal dia |
| 93 | 250 mm nominal dia |
| 94 | 300 mm nominal dia |
| 95 | Making slots of hole size and Nos. as directed by EIC in AC pressure pipe Class 15 as per technical specification for using slotted pipe in TW casing.Rate is exclusive of GST. |
| 96 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.Rates are exclusive of GST. |
| 97 | MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet) |
| 98 | MS pipe specials above 600mm dia(with minimum 6.3mm thickness sheet) |
| 99 | Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.Rates are exclusive of GST. |
| 100 | Centrifugal Monoblock Pump set (Single Stage) |
| 101 | 2.2 KW (3.0 HP) |
| 102 | 3.7 KW (5.0 HP) |
| 103 | 5.5 KW (7.5 HP) |
| 104 | 7.5 KW (10 HP) |
| 105 | 9.3 KW (12.5 HP) |
| 106 | 11.0 KW (15 HP) |
| 107 | 15.0 KW (20.0 HP) |
| 108 | 18.5 KW (25.0 HP) |
| 109 | Centrifugal Monoblock Pump set (Double Stage) |
| 110 | 3.7 KW (5.0 HP) |
| 111 | 5.5 KW (7.5 HP) |
| 112 | 7.5 KW (10.0 HP) |
| 113 | 9.3 KW (12.5 HP) |
| 114 | 11.0 KW (15.0 HP) |
| 115 | 15.0 KW (20.0 HP) |
| 116 | Vacuum Pump set (Monoblock) |
| 117 | Providing, installation, testing and commissioning of Mono block Vacuum pump set with base plate including C.C. foundation / cross channels / RSJ frame and foundation bolts etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge.Rates are exclusive of GST. |
| 118 | 0.75 KW (1 HP), single Ph |
| 119 | 2.2 KW (3 HP), three Ph |
| 120 | Vacuum Pump set (Coupled) |
| 121 | Providing, installation, testing and commissioning of Vacuum pump set with horizontal foot mounted TEFC squirrel cage motor working on three phase 50 Hz, 415 Volts +/- 10% with base plate including cost of flexible couplings, coupling guard etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge.Rates are exclusive of GST. |
| 122 | 3.7 KW (5.0 HP) |
| 123 | 7.5 KW (10.0 HP) |
| 124 | Providing, installation, testing and commissioning of Submerged Centrifugal Pump sets with motor 4 pole synchronised speed of 1500 rpm ( water immersed, dry air filled, class \\"F\\" insulated TEWC motor integrally mounted on volute casing pump sets for drinking water ) 3 phase, +/- 3%, 415 volt +/- 10%, along with suitable foundation/ installation device and with 10 mtr cable, material of construction of impeller SS, casing (volute) CI, wearing ring SS, etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.Rates are exclusive of GST. |
| 125 | 15 KW |
| 126 | 18.5 KW |
| 127 | 22 KW |
| 128 | 30 KW |
| 129 | 37 KW |
| 130 | 45 KW |
| 131 | 55 KW |
| 132 | 75 KW |
| 133 | 90 KW |
| 134 | 110 KW |
| 135 | 125 KW |
| 136 | 132 KW |
| 137 | 160 KW |
| 138 | 180 KW |
| 139 | 200 KW |
| 140 | Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and 2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.Rates are exclusive of GST. |
| 141 | 2.2 KW (3.0 HP) |
| 142 | 3.7 KW (5.0 HP) |
| 143 | 5.5 KW (7.5 HP) |
| 144 | 7.5 KW (10 HP) |
| 145 | 9.3 KW (12.5 HP) |
| 146 | 11.0 KW (15 HP) |
| 147 | 15.0 KW (20.0 HP) |
| 148 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.Rates are exclusive of GST. |
| 149 | 0.75 KW (1.0 HP) |
| 150 | 1.5 KW (2.0 HP) |
| 151 | 2.2 KW (3.0 HP) |
| 152 | 3.7 KW (5.0 HP ) |
| 153 | Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ.Rates are exclusive of GST. |
| 154 | Discharge 20 to 30 LPS and head 20 to 30 M |
| 155 | Discharge 20 to 30 LPS and head 31 to 40 M |
| 156 | Discharge 20 to 30 LPS and head 41 to 50 M |
| 157 | Discharge 20 to 30 LPS and head 51 to 60 M |
| 158 | Discharge 20 to 30 LPS and head 61 to 70 M |
| 159 | Discharge 20 to 30 LPS and head 71 to 80 M |
| 160 | Discharge 20 to 30 LPS and head 81 to 90 M |
| 161 | Discharge 31 t0 40 LPS and head 20 to 30 M |
| 162 | Discharge 31 t0 40 LPS and head 31 to 40 M |
| 163 | Discharge 31 t0 40 LPS and head 41 to 50 M |
| 164 | Discharge 31 t0 40 LPS and head 51 to 60 M |
| 165 | Discharge 31 t0 40 LPS and head 61 to 70 M |
| 166 | Discharge 31 to 40 LPS and head 71 to 80 M |
| 167 | Discharge 31 to 40 LPS and head 81 to 90 M |
| 168 | Discharge 41 t0 50 LPS and head 20 to 30 M |
| 169 | Discharge 41 t0 50 LPS and head 31 to 40 M |
| 170 | Discharge 41 t0 50 LPS and head 41 to 50 M |
| 171 | Discharge 41 t0 50 LPS and head 51 to 60 M |
| 172 | Discharge 41 t0 50 LPS and head 61 to 70 M |
| 173 | Discharge 41 to 50 LPS and head 71 to 80 M |
| 174 | Discharge 41 to 50 LPS and head 81 to 90 M |
| 175 | Discharge 51 to 60 LPS and head 20 to 30 M |
| 176 | Discharge 51 to 60 LPS and head 31 to 40 M |
| 177 | Discharge 51 to 60 LPS and head 41 to 50 M |
| 178 | Discharge 51 to 60 LPS and head 51 to 60 M |
| 179 | Discharge 51 to 60 LPS and head 61 to 70 M |
| 180 | Discharge 51 to 60 LPS and head 71 to 80 M |
| 181 | Discharge 51 to 60 LPS and head 81 to 90 M |
| 182 | Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ.Rates are exclusive of GST. |
| 183 | Discharge 201 to 220 LPS and head 20 to 30 M |
| 184 | Discharge 201 to 220 LPS and head 31 to 40 M |
| 185 | Discharge 201 to 220 LPS and head 41 to 50 M |
| 186 | Discharge 201 to 220 LPS and head 51 to 60 M |
| 187 | Discharge 201 to 220 LPS and head 61 to 70 M |
| 188 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note 1 : Rates are exclusive of tail piece/ dismantling joints and earth work.Note 2 : Rates are exclusive of GST. |
| 189 | Manually Operated CI Sluice valve of Class PN-1.0 |
| 190 | 80 mm HW |
| 191 | 100 mm HW |
| 192 | 125 mm HW |
| 193 | 150 mm HW |
| 194 | 200 mm HW |
| 195 | 250 mm HW |
| 196 | 300 mm HW |
| 197 | 350 mm with Gear |
| 198 | 400 mm with Gear |
| 199 | 450 mm with Gear |
| 200 | 500 mm with Gear |
| 201 | 600 mm with Gear |
| 202 | Motorized Sluice Valves with Electric Actuator with integral starter of Class PN 1.0 |
| 203 | 80 mm dia |
| 204 | 100 mm dia |
| 205 | 125 mm dia |
| 206 | 150 mm dia |
| 207 | 200 mm dia |
| 208 | 250 mm dia |
| 209 | 300 mm dia |
| 210 | 350 mm dia |
| 211 | 400 mm dia |
| 212 | 450 mm dia |
| 213 | 500 mm dia |
| 214 | 600 mm dia. |
| 215 | Providing, lowering, laying, aligning, fixing in position CI D/F short body pattern type butterfly valves having body, disc and end cover in graded cast iron generally conforming to (IS13095/1991amended up to date), synthetic rubber faced ring secured on disc by retaining ring with SS steel screw stub shaft of SS riding in Teflon bearing including C.C. foundation/ structural steel support, material, labour, testing along with pipe line and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note 1 : Rates are exclusive of tail piece/ dismantling joints and earth work.Note 2 : Rates are exclusive of GST. |
| 216 | Manually Operated Butterfly Valve PN-1.0 |
| 217 | 100 mm dia ( With lever operated) |
| 218 | 125 mm dia ( With lever operated) |
| 219 | 150 mm dia ( With lever operated) |
| 220 | 200 mm dia (With Gear Operated) |
| 221 | 250 mm dia (With Gear Operated) |
| 222 | 300 mm dia (With Gear Operated) |
| 223 | 350 mm dia (With Gear Operated) |
| 224 | 400 mm dia (With Gear Operated) |
| 225 | 450 mm dia (With Gear Operated) |
| 226 | 500 mm dia (With Gear Operated) |
| 227 | 600 mm dia (With Gear Operated) |
| 228 | 700 mm dia (With Gear Operated) |
| 229 | 800 mm dia (With Gear Operated) |
| 230 | 900 mm dia (With Gear Operated) |
| 231 | 1000 mm dia (With Gear Operated) |
| 232 | Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of SS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note 1 : Rates are exclusive of tail piece/ dismantling joints and earth work.Note 2 : Rates are exclusive of GST. |
| 233 | Class PN 1.0 |
| 234 | 80 mm dia |
| 235 | 100 mm dia |
| 236 | 125 mm dia |
| 237 | 150 mm dia |
| 238 | 200 mm dia |
| 239 | 250 mm dia |
| 240 | 300 mm dia |
| 241 | 350 mm dia |
| 242 | 400 mm dia |
| 243 | 450 mm dia |
| 244 | 500 mm dia |
| 245 | 600 mm dia |
| 246 | Providing, lowering, aligning, fixing in position in pipe line, CI double flanged Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Cover of Grey cast iron of IS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR (food grade quality) ,Body seat of SS ,Face to face dimensions as per API: 594 ,Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body & cover inside and outside . Shaft/Stop Pin of SS- AISI- 304/410 , Hinge SS AISI 316/304 / CS ,Spring SS AISI 316/304 , Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \\"O \\"ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note 1 : Rates are exclusive of tail piece/ dismantling joints and earth work.Note 2 : Rates are exclusive of GST. |
| 247 | Class PN 1.0 |
| 248 | 80 mm dia |
| 249 | 100 mm dia |
| 250 | 125 mm dia |
| 251 | 150 mm dia |
| 252 | 200 mm dia |
| 253 | 250 mm dia |
| 254 | 300 mm dia |
| 255 | 350 mm dia |
| 256 | 400 mm dia |
| 257 | 450 mm dia |
| 258 | 500 mm dia |
| 259 | 600 mm dia |
| 260 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air Valve Flanged/ Screwed type of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1,Body seat ring - Leaded tin bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS 6418 or Screwed type shall have external pipe threads conforming to IS 554 Fasteners - CS Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note 1 : Rates are exclusive of connecting tee, pipe piece and earth work.Note 2 : Rates are exclusive of GST. |
| 261 | Class PN 1.0 |
| 262 | 15 mm S-1 Type |
| 263 | 25 mm S-1 Type |
| 264 | 40 mm S-1 Type |
| 265 | 50 mm S-2 Type |
| 266 | Class PN 1.6 |
| 267 | 15 mm S-1 Type |
| 268 | 25 mm S-1 Type |
| 269 | 40 mm S-1 Type |
| 270 | 50 mm S-2 Type |
| 271 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide- HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note 1 : Rates are exclusive of connecting tee, pipe piece and earth work.Note 2 : Rates are exclusive of GST. |
| 272 | Class PN 1.0 |
| 273 | 40 mm |
| 274 | 50 mm |
| 275 | 80 mm |
| 276 | 100 mm |
| 277 | 150 mm |
| 278 | 200 mm |
| 279 | Class PN 1.6 |
| 280 | 40 mm |
| 281 | 50 mm |
| 282 | 80 mm |
| 283 | 100 mm |
| 284 | 150 mm |
| 285 | 200 mm |
| 286 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date),Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Grey cast iron of grade IS:210/FG200 ,Float- LP ball & HP ball : AISI 304 stainless Steel, Float Guide- HTB1,Seat ring & Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538. Epoxy paint (Non-Toxic & suitable for drinking water) applied on body & cover inside and outside Fasteners - CS/ Galvanised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, with CI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended up to date) PN 1.0 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note 1 : Rates are exclusive of connecting tee, pipe piece and earth work.Note 2 : Rates are exclusive of GST. |
| 287 | Class PN 1.0 |
| 288 | 40 mm |
| 289 | 50 mm |
| 290 | 80 mm |
| 291 | 100 mm |
| 292 | 150 mm |
| 293 | 200 mm |
| 294 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note 1 : Rates are exclusive of tail piece/ dismantling joints and earth work.Note 2 : Rates are exclusive of GST. |
| 295 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 |
| 296 | 80 mm dia |
| 297 | 100 mm dia |
| 298 | 125 mm dia |
| 299 | 150 mm dia |
| 300 | 200 mm dia |
| 301 | 250 mm dia |
| 302 | 300 mm dia |
| 303 | 350 mm dia |
| 304 | 400 mm dia |
| 305 | 450 mm dia |
| 306 | 500 mm dia |
| 307 | 600 mm dia. |
| 308 | 700 mm dia. With Gear |
| 309 | 800 mm dia. With Gear |
| 310 | 900 mm dia. With Gear |
| 311 | 1000 mm dia. With Gear |
| 312 | SITC of Digital Type Single Phase DOL Starter Electrical Control Feeder Panel, 63 A, suitalbe for operation of Single-phase pump set on 215V AC supply, comprising input MCB (DP 63A), GFU with auxiliary contact for earth fault protection, AC-3 duty PMCbased DC contactors 50 Amp. 1P (DOL type), Microprocessor based Digital Motor Protection Unit with necessary protection, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal, connectors, complete internal wiring with copper conductors (for control and power), capacitor bank and all necessary hardware. The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficent and and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.Upto 5 HP (Single Phase) |
| 313 | SITC of Digital Type DOL Starter Electrical Control Feeder Panel, 40A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input MCB (40Amp. FP), GFU with auxiliary contact for earth fault protection, 32Amp. AC-3 duty PMC based DC contactors(for DOL and APSC type),Microprocessorbased Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications,Heavy Duty terminal, connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.Up to 5 HP (DOL type) |
| 314 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415VAC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 32Amp. AC-3 duty PMC based DC contactors (For Star and Main), 40Amp. 1 Pole Contactor for APSC, 22Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.Above 5HP and upto 10HP (Star Delta type) |
| 315 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415VAC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 35Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 25Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.Above 10 HP and upto 15 HP (Star Delta type) |
| 316 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415VAC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 40Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 32Amp. Contactor for Delta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 7 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosureof1.6mmthickness,Completewithallstandard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.Above 15 HP and upto 20 HP (Star Delta type) |
| 317 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 125A, suitable for operation of 3-phase pump set on 415VAC supply, comprising input 125Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 45 Amp. AC-3 duty PMC based DC contactors (For Star and Main), 50Amp. 1Pole Contactor or APSC, 40Amp. Contactor for Delta, Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 8.3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.Above 20 HP and upto 25 HP (Star Delta type) |
| 318 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 125A, suitable for operation of 3-phase pump set on 415VAC supply, comprising input 125Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 63 Amp. AC-3 duty PMC based DC contactors (For Star and Main), 80Amp.1Pole Contactor forAPSC, 50Amp. Contactor for Delta, Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 12.5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge.Above 25 HP and upto 30 HP (Star Delta type) |
| 319 | Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints.Rate is exclusive of GST. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysDec 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender