Tender For Ffc/R/Mtc Of Different Rws Schemes / S.H.: Providing And Installation Of 10,000 Gph, 5,000 Gph, 2000 Gph Submersible Pump Sets, Providing & Extension Of New Upvc Pipeline, Fhtc, Necessary Maintenance, Repair Of Pipeline Segments By mainten
Tender Overview
Project Description
Tender for Ffc/R/Mtc Of Different Rws Schemes / S.H.: Providing And Installation Of 10,000 Gph, 5,000 Gph, 2000 Gph Submersible Pump Sets, Providing & Extension Of New Upvc Pipeline, Fhtc, Necessary Maintenance, Repair Of Pipeline Segments By maintenance Of Leakage, Washing Of Pipeline, Tyton Joint, Sluice Valave Fixation Etc And Other Allied Works At Different Rpws Schemes Under Manubazar Gp, Kalapania Gp, Goachand Nandigram Gp Etc Within Satchand Rd Block Under Dws Sub-Division, Sabroom.
BOQ
| Sl. No. | Item Description |
| 1 | Providing, fitting fixing and installation of 10,000 GPH x 76 mtrs. Head water lubricated submersible pump of maximum 150 mm outer dia. With maximun 10(Ten) stages coupled with required water and non-cover loading submersible motor suitable for 340-440 volts, 3 phase 50Hz, AC supply and star delta method of starting along with 35 mtrs. x 2 x 3 x 4 sq.mm joint less PVC 3 (three) core double length flat cable (continuous length) of suitable size fitted with submersible motor, suction case, strainer, coupling key, vertical non- return valve cum discharge case including supplying of 10 Nos. suitable cable guard with clips and nuts & bolts, 2 (two) pair M.S. column clamps as per direction of Engineer-in-charge conforming to terms & conditions of the contract (Each pump with motor shall consists of stainless stell closed type impeller , C.I. bowl, C.I discharge case, pump shaft (styainless steel), bush (bronze), shaft sleeve (bronze/ chromium), sand guard, winding rotor, stator, counter thrust plate, thrust plate, thrust bearing segment etc. conforming to relevant BIS codes of madeDUKE/KSB/WPIL/CRI).(ONE SPARE) |
| 2 | Providing, fitting fixing and installation of 5000 GPH x 76 mtrs. Head water lubricated submersible pump of maximum 150 mm outer dia. With maximun 10(ten) stages coupled with required water and non-cover loading submersible motor suitable for 340-440 volts, 3 phase 50Hz, A.C supply and star delta method of starting along with 35 mtrs. x 2 x 3 x 4 sq.mm joint less PVC 3 (three) core double length flat cable (continuous length) of suitable size fitted with submersible motor, suction case, strainer, coupling key, vertical non- return valve cum discharge case including supplying of 10 Nos. suitable cable guard with clips and nuts & bolts, 2 (two) pair M.S. column clamps as per direction of Engineer-in-charge conforming to terms & conditions of the contract (Each pump with motor shall consists of stainless stell closed type impeller , C.I. bowl, C.I discharge case, pump shaft (styainless steel), bush (bronze), shaft sleeve (bronze/ chromium), sand guard, winding rotor, stator, counter thrust plate, thrust plate, thrust bearing segment etc. conforming to relevant BIS codes of made DUKE/KSB/WPIL/CRI). |
| 3 | Supplying and fitting fixing of submersible pump of 2000 GPH Capacity, 45 mtr head with motor of 3 HP/ required capacity single phase including 40 mm dia 30.00 mtr. heavy duty G.I. pump assembly and reducing socket, delivery band 900 Non-return valve and fitting etc. as per direction of the Engineer-in-charge. |
| 4 | Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope-1 in 200)including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. |
| 5 | A) For UPVC pipes in new work.a. All kind of Soilsi) For pipes not exceeding 90 mm dia |
| 6 | ii) For pipes exceeding 90mm dia but not exceeding 300mm dia. |
| 7 | Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.A. Class - 3 ( working pressure 6.0 kg / cm2) |
| 8 | i. 40 mm OD |
| 9 | iii) 90mm OD |
| 10 | iv)110mm OD |
| 11 | v)140mm OD |
| 12 | Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 13 | iii) 90 mm dia |
| 14 | iv) 110 mm dia |
| 15 | v) 140 mm dia |
| 16 | Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 17 | iii) 90 mm dia |
| 18 | iv) 110 mm dia |
| 19 | Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 20 | iii) 90 x 90 mm dia |
| 21 | iv) 110 x 110 mm dia |
| 22 | v) 140 x 140 mm dia |
| 23 | Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 24 | ii) 110 x 90 mm dia |
| 25 | iii) 140 x 110 mm dia |
| 26 | Providing, fixing and laying flanged fabricated UPVC tailpiecewith MS flange ( 8 mm thick ) conforming to IS : 10124 ( Part6 ) with solvent cement conforming to IS : 14182 including testing of joints complete as er CPWD specification anddirection of the Engineer - in - charge. |
| 27 | i) 90 mm dia |
| 28 | ii. 110 mm dia |
| 29 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. |
| 30 | i. 80 mm dia. A. PN - 1.6 |
| 31 | ii) 100 mm dia. A. PN - 1.6 |
| 32 | Providing and fixing brass ferrule with C.I. cover conforming to IS : 2692 including boring and tapping the main as per CPWD specification and direction of the Engineer - in - charge. i) 15 mm nominal bore |
| 33 | Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge. i) 15 mm dia |
| 34 | Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge. i) 15 mm dia |
| 35 | Providing and laying of flexible PVC pipe (conforming to IS:7634) complete as per specification and direction of the Engineer - in - charge (cost of earth work and fittings will be paid separately). i) 15 mm dia |
| 36 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i) 15 mm dia |
| 37 | Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge.i) 15 mm dia PVC /plastic bib cock |
| 38 | Charges for repairing of leakage in UPVC / HDPE pipe line with PVC coupler & solvent cement etc. including necessary earth excavation, backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in-charge. |
| 39 | i) 90 mm OD |
| 40 | ii) 110 mm OD |
| 41 | iii) 140 mm OD |
| 42 | Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge.B. by manual means |
| 43 | Charges for dismantling PVC / HDPE pipe after necessaryexcavation of earth including washing and stacking of pipesproperly at site with all leads and lifts and backfilling of soilas required in layers not exceeding 200 mm in depthincluding consolidating each deposited layer by ramming,watering etc. complete as per specification & direction of the Engineer-in-charge. |
| 44 | i)90 mm dia. |
| 45 | ii. 110 mm dia. |
| 46 | iii. 140 mm dia. |
| 47 | Dismantling old C.I. / D.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at site lead upto 50 metre as per chapter 20 of CPWD specification and direction of the Engineer - in - charge. |
| 48 | i. 100 mm dia |
| 49 | ii) 150 mm dia |
| 50 | Constructing masonry Chamber 90x90x100 cm,inside with 75 class designation brick work incement mortar 1:4 (1 cement : 4 fine sand) for sluicevalve, with C.I. surface box 100 mm. topdiameter, 160 mm bottom diameter and 190 mmdeep (inside) with chained lid and RCC top slab 1:2:4mix (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size ) necessaryexcavation foundation concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40 mmnominal size ) and inside plastering with cementmortar 1:3 (1 cement : 3 coarse sand) 12 mm thickfinished with a floating coat of neat cement completeas per standard design :With Second Class bricks Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents