Tender For Turnkey Construction Of 1(One) Nos. Of 33Kv Bays For Oil, Charigaon At 132Kv Gss, Aegcl, Garmur
Tender Value
1.66 Crore
Estimated cost
Bid Submission
14 Dec 2026
20 days left
EMD
3.33 Lakhs
Bank guarantee accepted
Document Fee
3500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jorhat → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Turnkey Construction Of 1(One) Nos. Of 33Kv Bays For Oil, Charigaon At 132Kv Gss, Aegcl, Garmur
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Equipment and accessories |
| 2 | 33kV, 25kA, 800A\\" SF6 Gang operated CircuitBreaker/VCB complete with mounting structure andaccessories including Terminal connectors and Gas filling Kit. |
| 3 | 33kV, 300-600/1-1A, 2-Core Single Phase CT completewith all fittings and accessories including Terminalconnectors (0.2s-5p20 Class, live tank type), marshalling box as required. |
| 4 | 36kV, 3 Phase PT including all accessories and terminalconnectors, marshalling box as required. |
| 5 | 36kV, 25kA, 1250A motorised isolators with Earth Switchcomplete with all fittings and accessories includingTerminal connectors. |
| 6 | 36kV, 25kA, 1250A motorised isolators without EarthSwitch complete with all fittings and accessories includingTerminal connectors. |
| 7 | 33kV Lightning Arrester complete with all fittings andaccessories including Terminal connectors and surgecounter |
| 8 | 33kV, 8kN Post insulator with all fittings including Terminalconnectors |
| 9 | Mounting Structures With mounting & foundation bolts asper drawing. |
| 10 | a) 33kV Motorised isolators without Earth Switch |
| 11 | b) 33kv CT |
| 12 | c) 33kV PT |
| 13 | d) 33kV LA |
| 14 | e) 33kv PI |
| 15 | f) 33kV Motorised isolators with Earth Switch |
| 16 | Indoor floor mounted 33kV Feeder Control and Relay Panel (Simplex Type) (with BCU) suitable for integration to existing Siemens SAS |
| 17 | Managed Ethernet Switch with OF PATCH cable |
| 18 | ABT compliant Energy meter conforming SAMAST scheme as per specification including installation |
| 19 | Insulator strings, Clamps & Connectors (UPG, T Etc.) |
| 20 | a) UPG clamps for connection to Bus. (Zebra to Panther) |
| 21 | b) T-clamps tor connection to Bus. (Zebra to Zebra) |
| 22 | c) Spacer for twin ACSR Zebra bus and jumper conductor |
| 23 | PVC Armoured Control Cable (Copper) |
| 24 | a) 4CX2.5 sqmm |
| 25 | b) 7CX1.5 sqmm |
| 26 | c) 19CX 1.5 sqmm |
| 27 | d) 12CX 1.5 sqmm |
| 28 | Armoured Power Cable (Aluminium) |
| 29 | a) 2CX6.0 sqmm |
| 30 | b) 4CX l6.0sqmm |
| 31 | c)3 1/2 C X35.0 sqmm |
| 32 | Supply and installation of-AC Marshalling Kioskincluding construction of foundation, installation andcable foundation.l. 2No 63 A, 4P (Incomer)2. 3No 25A ,4P (Outgoing)3. SNo l6.A, 4P (Outgoing)4. 8No l0A, 4P (Outgoing)5. 5No l0A,2P (Outgoing) |
| 33 | Supply of lattice type Structures steel (for column beams) |
| 34 | a) Column (C5B) with peak, 7.5mtrs. |
| 35 | b) Supply of 02 beams levels at both 5.5 mtrs. |
| 36 | ACSR Zebra Conductor |
| 37 | Illumination of switchyard |
| 38 | a) Supply of Portable LED Light Tower set with all fittings for bayillumination |
| 39 | b) Supply of LED Lighting set with all fittings for bay illumination. |
| 40 | Earth mat Extension and associated earthing of equipments |
| 41 | a) 50x06 GI flat Earthing conductor for earthing of indoorL.T and control panels, Junction box, Marshalling boxesetc. |
| 42 | b) 50 mm dia, 3m long GI perforated pipe. |
| 43 | c) GI flates (65X12mm) for earthmat as directed. |
| 44 | d) GI steel wires (37/5.5mm) |
| 45 | Mandatory Spares |
| 46 | a) 33kV, 25kA, 1250A Isolators Female contact (entireassembly) |
| 47 | b) 33kV, 25kA, 1250A, Isolators Moving contact (entireblade assembly) |
| 48 | c) 33kV, 600-300/1-1 A, 2 - Core CT |
| 49 | d) 33kV Lightning Arrester |
| 50 | e) Numerical Backup Relay (@30% on 33kV Feeder Controland Relay Panel (Simplex Type) suitable for integration toSiemens SAS |
| 51 | f) Master trip Relay @ 10% on 33kV Feeder Control andRelay Panel (Simplex Type) suitable for integration toSiemens SAS |
| 52 | g) Supply of SF6 Gas cylinder if SF6 Circit Breaker is providedby the Bidder (Qty- 9Kg) or supply of 1no of VCB pole suitablefor fitting in any phase of the pole i.e., RYB phase (Qty-1 ) |
| 53 | h) Bay control unit @ 30% on 33kV Feeder control andRelay Panel (Simplex Type) suitable for integration toSiemens SAS |
| 54 | i) O/C & E/F relay |
| 55 | j) Earthing Stick |
| 56 | For 33kV SF6 CB/VCB |
| 57 | a) Operating Mechanism |
| 58 | b) Trip Coil for 33kV CB |
| 59 | c) Closing Coil for 33kV CB |
| 60 | d) Spring charging Motor |
| 61 | e)SF6 gas density monitor |
| 62 | Cable Tray |
| 63 | a) Perforated type 600mm wide |
| 64 | a) Perforated type 300mm wide |
| 65 | Insulator with all hardware fitting twin conductor |
| 66 | 240KN Double Tension Disc Insulators (8 nos. of Disc/set) |
| 67 | OFC PATCH cord |
| 68 | i) ST-LC |
| 69 | ii)ST-ST |
| 70 | Fire fighting equipments |
| 71 | a) 22.5kg FE CO2 type trolley mounted |
| 72 | b) DCP 5kg capacity, wall mounted |
| 73 | c) Fire Bucket (12 nos. with stand in one set |
| 74 | Supply of Equipment and accessories |
| 75 | 33kV, 25kA, 800A\\" SF6 Gang operated CircuitBreaker/VCB complete with mounting structure andaccessories including Terminal connectors and Gas filling Kit. |
| 76 | 33kV, 300-600/1-1A, 2-Core Single Phase CT completewith all fittings and accessories including Terminalconnectors (0.2s-5p20 Class, live tank type), marshalling box as required. |
| 77 | 36kV, 3 Phase PT including all accessories and terminalconnectors, marshalling box as required. |
| 78 | 36kV, 25kA, 1250A motorised isolators with Earth Switchcomplete with all fittings and accessories includingTerminal connectors. |
| 79 | 36kV, 25kA, 1250A motorised isolators without EarthSwitch complete with all fittings and accessories includingTerminal connectors. |
| 80 | 33kV Lightning Arrester complete with all fittings andaccessories including Terminal connectors and surgecounter |
| 81 | 33kV, 8kN Post insulator with all fittings including Terminalconnectors |
| 82 | Mounting Structures With mounting & foundation bolts asper drawing. |
| 83 | a) 33kV Motorised isolators without Earth Switch |
| 84 | b) 33kv CT |
| 85 | c) 33kV PT |
| 86 | d) 33kV LA |
| 87 | e) 33kv PI |
| 88 | f) 33kV Motorised isolators with Earth Switch |
| 89 | Indoor floor mounted 33kV Feeder Control and Relay Panel (Simplex Type) (with BCU) suitable for integration to existing Siemens SAS |
| 90 | Managed Ethernet Switch with OF PATCH cable |
| 91 | ABT compliant Energy meter conforming SAMAST scheme as per specification including installation |
| 92 | Insulator strings, Clamps & Connectors (UPG, T Etc.) |
| 93 | a) UPG clamps for connection to Bus. (Zebra to Panther) |
| 94 | b) T-clamps tor connection to Bus. (Zebra to Zebra) |
| 95 | c) Spacer for twin ACSR Zebra bus and jumper conductor |
| 96 | PVC Armoured Control Cable (Copper) |
| 97 | a) 4CX2.5 sqmm |
| 98 | b) 7CX1.5 sqmm |
| 99 | c) 19CX 1.5 sqmm |
| 100 | d) 12CX 1.5 sqmm |
| 101 | Armoured Power Cable (Aluminium) |
| 102 | a) 2CX6.0 sqmm |
| 103 | b) 4CX l6.0sqmm |
| 104 | c)3 1/2 C X35.0 sqmm |
| 105 | Supply and installation of-AC Marshalling Kioskincluding construction of foundation, installation andcable foundation.l. 2No 63 A, 4P (Incomer)2. 3No 25A ,4P (Outgoing)3. SNo l6.A, 4P (Outgoing)4. 8No l0A, 4P (Outgoing)5. 5No l0A,2P (Outgoing) |
| 106 | Supply of lattice type Structures steel (for column beams) |
| 107 | a) Column (C5B) with peak, 7.5mtrs. |
| 108 | b) Supply of 02 beams levels at both 5.5 mtrs. |
| 109 | ACSR Zebra Conductor |
| 110 | Illumination of switchyard |
| 111 | a) Supply of Portable LED Light Tower set with all fittings for bayillumination |
| 112 | b) Supply of LED Lighting set with all fittings for bay illumination. |
| 113 | Earth mat Extension and associated earthing of equipments |
| 114 | a) 50x06 GI flat Earthing conductor for earthing of indoorL.T and control panels, Junction box, Marshalling boxesetc. |
| 115 | b) 50 mm dia, 3m long GI perforated pipe. |
| 116 | c) GI flates (65X12mm) for earthmat directed. |
| 117 | d) GI steel wires (37/5.5mm) |
| 118 | Mandatory Spares |
| 119 | a) 33kV, 25kA, 1250A Isolators Female contact (entireassembly) |
| 120 | b) 33kV, 25kA, 1250A, Isolators Moving contact (entireblade assembly) |
| 121 | c) 33kV, 600-300/1-1 A, 2 - Core CT |
| 122 | d) 33kV Lightning Arrester |
| 123 | e) Numerical Backup Relay (@30% on 33kV Feeder Controland Relay Panel (Simplex Type) suitable for integration toSiemens SAS |
| 124 | f) Master trip Relay @ 10% on 33kV Feeder Control andRelay Panel (Simplex Type) suitable for integration toSiemens SAS |
| 125 | g) Supply of SF6 Gas cylinder if SF6 Circit Breaker is providedby the Bidder (Qty- 9Kg) or supply of 1no of VCB pole suitablefor fitting in any phase of the pole i.e., RYB phase (Qty-1 ) |
| 126 | h) Bay control unit @ 30% on 33kV Feeder control andRelay Panel (Simplex Type) suitable for integration toSiemens SAS |
| 127 | i) O/C & E/F relay |
| 128 | j) Earthing Stick |
| 129 | For 33kV SF6 CB/VCB |
| 130 | a) Operating Mechanism |
| 131 | b) Trip Coil for 33kV CB |
| 132 | c) Closing Coil for 33kV CB |
| 133 | d) Spring charging Motor |
| 134 | e)SF6 gas density monitor |
| 135 | Cable Tray |
| 136 | a) Perforated type 600mm wide |
| 137 | a) Perforated type 300mm wide |
| 138 | Insulator with all hardware fitting twin conductor |
| 139 | 240KN Double Tension Disc Insulators (8 nos. of Disc/set) |
| 140 | OFC PATCH cord |
| 141 | i) ST-LC |
| 142 | ii)ST-ST |
| 143 | Fire fighting equipments |
| 144 | a) 22.5kg FE CO2 type trolley mounted |
| 145 | b) DCP 5kg capacity, wall mounted |
| 146 | c) Fire Bucket (12 nos. with stand in one set |
| 147 | Erection of mounting structure as required, including construction of foundation and supply of all foundation materials and structures earthing including labour cost etc, as required to complete the job. |
| 148 | 33kV SF6 Circuit Breaker /VCB |
| 149 | 33KV CT |
| 150 | 33KV PT |
| 151 | 33kV Isolator |
| 152 | 33KV LA |
| 153 | 33kV Post Insulator |
| 154 | Erection, Testing and commissioning including laying of control cables and equipment earthing as required. |
| 155 | 33kV SF6 Circuit Breaker/VCB |
| 156 | 33KV CT |
| 157 | 33KV PT |
| 158 | 33kV Isolator |
| 159 | 33KV LA |
| 160 | 33kV Post Insulator |
| 161 | Erection of switchyard latice tower structures including construction of foundation |
| 162 | Erection of beam |
| 163 | Installation of earthing system |
| 164 | Installation of earth electrode with test linksincluding construction of CI covered earth pits. |
| 165 | Construction of extended earth mat using GI flats andconnection to risers for equipment earthing as directed. |
| 166 | Erection of 50X6mm GI flat |
| 167 | Construction of Cable trench, Cable tray, Cable slab & Roads. |
| 168 | a) C Type |
| 169 | b) D Type |
| 170 | c) Switchyard approach Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. (3mtrs wide) |
| 171 | Switchyard PCC and Gravelling |
| 172 | Providing 80mm thick PCC base in prop 1:4:8 as per drawing & specifications inclucling site preparation, dewedit, supply of all materials, labour etc. |
| 173 | Providing switchyard gravelling ( I 00mm thickness)levelling etc as per directions of site engineer |
| 174 | Installation and commissioning of the C&R panel |
| 175 | lnstallation of C/R panel in KIOSK, including testing andcommissioning and lntegration of C&R panel into existing SAS including all required accessories. |
| 176 | Hosting of insulator string, stringing of conductors, jumper, dropping etc, lightning spikes etc including supply of GI standard shield wire clamps & connectors etc as required for whole. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 24, 2026
11:30 IST
Tender Published
Tender notice published.
TodayDec 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysDec 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender