Tender for Operation And maintenance Of Drinking Water Scheme Along With Irp Under Dws Division Ambassa During The Year 2026-27/ Operation Of 5000 Gph Pumpset Along With Package Type Irp Of 5000 Gph Capacity By Engaging Skilled Worker Complete For 365 Days Along With Running Maintenance Works Of Existing Dtw & Sbdtw Schemes At Dhalai District Hospital, Kulai Under Dws Sub-Division Ambassa.
BOQ
| Sl. No. | Item Description |
| 1 | Operation, up-keepment and mtc. of whole plant i.e. package type IRP of 5000 GPH capacity including pump for minimum 09(nine) hours operation per day including 02(two) hours backwash twice in a day etc. complete in all respect as per direction of the Ingineer-in-charge. |
| 2 | Labour charge for Lifting of 20000/10000/5000 GPH capacity water lubricated vertical Submersible pump with motor in/c upto 150ft column pipe assembly by heavy duty chain pully block as per direction of the Engineer-in-charge |
| 3 | Labour charge for fitting fixing & lowering of 20000/10000/5000 GPH capacity water lubricated vertical Submersible pump with motor in/c column assembly upto 150 ft by heavy duty chain pulley block including fitting fixing nuts & bolts etc complete as per direction of the Engineer-in-charge |
| 4 | Supplying & fitting fixing of bolts and nuts and rubber insertions as per requirement for fitting fixing of GI flange MS clamps etc complete as per specification and the direction of the Engineer-in-charge. |
| 5 | i) 12 mm dia/16 mm dia Full threaded)ii) Rubber insertion |
| 6 | a) 65mm dia |
| 7 | Providing & fitting fixing of G.I. flange ( 10 mm wall thickness ) by welding with G.I. / MS pipe and placing position as per specification and the direction of the Engineer-in-charge. |
| 8 | i) 65 mm dia. |
| 9 | ii) 80 mm dia. |
| 10 | iii) 100 mm dia. |
| 11 | Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 12 | i) 80 x 40 mm dia |
| 13 | ii) 100 x 40 mm dia |
| 14 | iii) 100 x 80 mm dia |
| 15 | Charges for making G.I. Short piece i/c. cutting, threading at bothend,fitting, fixing at site etc. as per specification and the direction of the Engineer-in-charge. ( G.I. pipes will be supplied from the department free of cost ). |
| 16 | i) 65 mm dia. |
| 17 | ii) 80 mm dia. |
| 18 | Providing & fabrication of column pipe including fitting fixing of G.I. flange by cutting the GI pipe ( conforming to IS : 1239 medium class ) into 3.05 mtr. long and welding the same with GI flange as per specification and direction of the Engineer-in-charge ( G.I. pipe will be provided by the agency at his own cost & risk). |
| 19 | i) For 65 mm dia G.I. pipe with 10 mm thick GI flange |
| 20 | Repair and maintenance of 10 HP / 12.5 HP Motor suitable for 5000 GPH capacity submerssible pumpset by complete dismantling in/c providing & fitting fixing of PVC ( IS : 8783-1978 ) insulated electro grade copper ( IS : 613-1984 ) conductor winding in stator & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 21 | Repair and maintenance of 5000 GPH capacity submerssible pump by complete dismantling including providing and fitting fixing of all necessary spare parts ( conforming to IS : 8034 ) and reassembling the same including machining, servicing & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 22 | i) Bronze/SS Impeller |
| 23 | ii)Bronze grade LTB 2/ cutless rubber bush |
| 24 | iii) Bronze grade LTB 2/12% chromium steel grade shaft sleeve |
| 25 | iv)Stainless steel pumpshaft |
| 26 | v)Cast Iron grade (FG200) discharge casing. |
| 27 | vi)Cast Iron grade (FG200) Suction casing. |
| 28 | vii)Cast Iron grade (FG200) Pumbbowl/Diffuser |
| 29 | viii) SS Impeller lock. |
| 30 | ix) SS half coupling |
| 31 | x) stud bolt and nut |
| 32 | xi) Dismantling, repairing, reassembling, servicing |
| 33 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc. complete as per specification and direction of the Engineer-in-charge. |
| 34 | i. 63 Amps |
| 35 | Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge. |
| 36 | i. 25 HP/18.5 kw Relay range within 13-21 + 10% |
| 37 | Providing and fitting fixing of Direct on line (DOL) motor starter L&T/BCH make ( 3 phase, 50 Hz, 10 HP/7.5 kw relay range within 13-21 + 10%) in steel sheet enclosure complete as per direction of the engineer in charge. |
| 38 | Providing and fitting fixing of 6 feet x 4 feet x 1 inch (thickness) Gamair wood / plywood pannel board for fitting fixing of electrical items, in/c 2 nos MS angle post ( size 2 inch x 2 inch x 9 feet ), nuts & bolts etc. for irrection of the same by 1:1.5:3 cement concrete casting ( 1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats & plastic paint as per specification and direction of the Engineer-in-charge. |
| 39 | Providing and fitting fixing with PVC insulated single core multistrand Copper cable conforming to IS : 694 for inter connection with all electrical equipments of the pannel board as per specification and direction of the Engineer-in-charge. |
| 40 | i. 10 sqmm |
| 41 | Providing and fitting fixing with PVC insulated 3 core flat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required as per specification and direction of the Engineer-in-charge. |
| 42 | ii. 6.0 sqmm |
| 43 | Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. |
| 44 | Providing and fitting fixing of moving iron type, Range 0-100/0-200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. |
| 45 | Providing and fitting fixing of Moulded Case Circuit Breaker (MCCB) of different Thermal release range , 415 + V, 50Hz (L & T, BCH, ABB make) as per specification and direction of the Engineer-in-charge. |
| 46 | iii. 50-63 Amps |
| 47 | Providing and fitting fixing 3 phase indicating lamp fiited with panel board with three different colour lamps with batten holder complete as per specification and direction of the Engineer-in-charge. |
| 48 | Providing and fitting fixing heavy duty box type (Resin filled) power factor correction capacitor L & T make etc. complete as per specification and direction of the Engineer-in-charge. |
| 49 | i. 5-15 kVAr 440 V |
| 50 | Supplying and fixing of fuse unit kitkat in porcelain base in/c necessary connection etc. as per required (HPL) make. |
| 51 | i) 63 Amps cutout |
| 52 | Supplying & fixing of aluminium thimble in/c necessary connection etc as required |
| 53 | Providing and fitting fixing Single phasing preventor +selectable under voltage +selectable over voltage on delay 5 sec & off delay 15 sec phase asymmetry 10% L & T /BCH/HAVELS/Siemens etc. make complete as per specification and direction of the Engineer-in-charge. |
| 54 | Providing and fitting fixing of Bimetal overload relay type series L&T make) as per direction of the Engineer-in-charge. |
| 55 | i. 13-21 AMP |
| 56 | Providing and fitting fixing of slandered operation coil for 415V,50Hz,L&T make as per direction of the Engineer-in-Charge. |
| 57 | i. ML 1.5 |
| 58 | Repairing of existing L&T make FASD Starter by providing & fitting fixing of necessary spare contact kit(in/c spare coil),replacement of damaged connection wire in the starter,testing & commissioning etc. as per specification & direction of the Engineer-in-Charge. |
| 59 | i. ML 1.5 |
| 60 | Providing and fitting fixing of Thermal Timer Type GT 200,415V,50Hz for 5-18 sec,L&T make as per direction of the Engineer-in-Charge. |
| 61 | Lifting of submersible pump motor with delivery assembly by heavy duty chain pully after dismantling from the delivery line and stacking poperly as per direction of the Engineer-in-charge. |
| 62 | Labour charge for fitting fixing & laying of Submersible pump motor set with delivery assembly 90° to 0° in/c refitting fixing with delivery line etc as per direction of the Engineer-in-charge. |
| 63 | Supplying and installation of water lubricated subermissible pump of Duke make(Model No. DSP4RFH05) having capacity 2000 GPH at total head of 45 mtr. Coupled with submerssible motor suitable for 240 volts (+10% verification) single phase 50 HP. AC suppluy DOL starting method to run at 2880 RPM along with 35 mtr. 2.5sqm, PVC insulated 3 core flat cable conforming to IS code and cable in/c fitting , fixing and lowering 40 mm dia GI pipe upto 100 ft.(30 mtr) etc. complete as per direction of the Engineer-in-charge (required 40 mm dia GI pipe will be supplied by the Dept. at free of cost) |
| 64 | Repair and maintenance of submessible Motor suitable for submerssible pumpset by complete dismantling in/c providing & fitting fixing of PVC ( IS : 8783-1978 ) insulated electro grade copper ( IS : 613-1984 ) conductor winding in stator & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 65 | i. 2.0 HP Motor suitable for 2000 GPH capacity submerssible pumpset |
| 66 | Repairing of single phase motor starter in/c necessary electric wiring as per direction of the Engineer-in-charge. |
| 67 | Supplying and fitting fixing of 32 Amps single phase main switch of BCH/Havel's make in/c cost of necessary copper wire wiring complete as per direction of the Engineer-in-charge.32 Amps |
| 68 | Providing & fitting fixing of different capacity 230 volt, single phase submersible pump starter BCH/L&T,AB make as per specification & direction of the Engineer-in-charge.i) 2 HP |
| 69 | Supplying & fitting fixing of B13 (size;-width 450mm x length 1200mm x height 850 mm) fitted with 4 nos support of 75 mmx 75mm (6mm thick) M.S. angle for embedding in 1:2:4 cement concrete base (size 300 mm x 300mmx 600 mm) with proper locking arrangement and coated with anti corrosive paint (both inside and outside ) including necessary provisions for fitting fixing of single phase motor starter unit, main switch, energy meter etc. complete in all respect as per direction of the Engineer in Charge |
| 70 | Providing and fitting fixing with PVC insulated 3 core flat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required as per specification and direction of the Engineer-in-charge.2.50 sqmm |
| 71 | Labour charges for repairing of leakage for CI/DI pipeline of various diameter by manual labour by hammering of old lead joints and other leakages of pipeline in/c excavation & refilling of the same as per direction of the Engineering-in-charge ( pig lead will be supplied by the department at free of cost). |
| 72 | a)80mm dia |
| 73 | b) 100 mm dia |
| 74 | c) 150 mm dia |
| 75 | Charges for repairing of leakage in UPVC/HDPE pipe line with PVC coupler/GI Socket/GI Union & teflon tape or solvent cement etc. in/c necessary earth excavation backfilling of soil as required after laying of pipeline , in layers not exceeding 200mm in dept in/c consolidating each deposited layer by ramming,watering etc.Complete as per specification & direction of Engineering-in-charge. |
| 76 | a) 15 mm OD |
| 77 | b) 25 mm OD |
| 78 | c) 40 mm OD |
| 79 | Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge.A)For UPVC Pipe for new work a.In all kinds of soil |
| 80 | i) For pipes not exceeding 90 mm dia |
| 81 | Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. Class - 3 ( working pressure 6.0 kg / cm2) |
| 82 | i) 40 mm OD |
| 83 | Providing and laying of flexible PVC pipe (conforming to IS:7634) complete including earth work as per specification and direction of the Engineer - in - charge (cost of fittings will be paid separately). |
| 84 | i. 15 mm dia. |
| 85 | ii. 25 mm dia. |
| 86 | Welding on CI/DI pipes, sluice valve etc by Gas or Electric plant including transportation of plant at site using light coated electrode with graphite based coating for welding cast iron without preheating (The electrode gives a nickel copper (monel deposit)) etc. complete as per standard design including pumping out water. |
| 87 | Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge. External work. |
| 88 | i) 15 mm dia. nominal bore |
| 89 | ii) 25 mm dia. nominal bore |
| 90 | iii) 40 mm dia. Nominal bore |
| 91 | iv) 50 mm dia. Nominal bore |
| 92 | v) 80 mm dia. nominal bore |
| 93 | vi) 100 mm dia. nominal bore |
| 94 | Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge |
| 95 | i)15 mm dia |
| 96 | ii)25 mm dia |
| 97 | iii)40 mm dia |
| 98 | iv)50 mm dia |
| 99 | Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge. |
| 100 | i. 15 mm dia |
| 101 | ii) 25mm dia |
| 102 | iii) 40mm dia |
| 103 | iv) 50mm dia |
| 104 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 105 | i)15 mm dia |
| 106 | ii) 25mm dia |
| 107 | iii) 40mm dia |
| 108 | iv) 50mm dia |
| 109 | Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 110 | i. 25x15 mm dia |
| 111 | ii. 40x15 mm dia |
| 112 | iii. 40x25 mm dia |
| 113 | iv. 50x25 mm dia |
| 114 | v. 50x40 mm dia |
| 115 | vi. 80x40 mm dia |
| 116 | vi. 80x50 mm dia |
| 117 | vii) 100 x 40 mm dia |
| 118 | viii) 100 x 80 mm dia |
| 119 | Providing and fixing GI equal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer-in-charge. |
| 120 | i. 15x15x15 mm dia. |
| 121 | ii. 25x25x25 mm dia |
| 122 | iii. 40x40x40 mm dia |
| 123 | iv. 80x80x80 mm dia |
| 124 | v. 100x100x100 mm dia |
| 125 | Providing and fixing GI Unequal Tee with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer-in-charge. |
| 126 | i. 25x25x15 mm dia. |
| 127 | ii. 40x40x25 mm dia |
| 128 | iii. 40x40x15 mm dia |
| 129 | Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge. |
| 130 | i. 15 mm dia PVC /plastic bib cock |
| 131 | Providing and fixing G.I. Full way valve as per CPWD specification and direction of the Engineer - in - charge. |
| 132 | i. 15 mm dia |
| 133 | ii. 25 mm dia. |
| 134 | ii. 40mm dia |
| 135 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. |
| 136 | i) 80 mm P.N 1.6 |
| 137 | ii) 100 mm P.N 1.6 |
| 138 | iii) 200 mm P.N 1.6 |
| 139 | Making supplying and fitting fixing of MS spindles in/c socket for sluice valve as per departmental sample |
| 140 | i. 80mm dia |
| 141 | ii. 100mm dia |
| 142 | R/Mtc of different dia C.l sluice valves by providing and replacing complete with bolts, nuts rubber insertions elc as per direction of the Engineer-in-charge. |
| 143 | i. 80mm dia |
| 144 | ii. 100mm dia |
| 145 | Labour charge for fitting foding of gland rope in Cl sluice valve of various dia (80 mm dia to 250 mm dia) as per direction of Engincer-in-Changs (Including the cost of gland rope, grease.nuts and bolts etc) |
| 146 | Providing and fixing C.I. non-return valve of approved quality as per of CPWD specification and direction of the Engineer - in - charge. |
| 147 | i. 80 mm nominal bore |
| 148 | ii. 100 mm nominal bore |
| 149 | Labour charge for clearing of deposited iron clouded in the CI pipeline of different dia (200mm, 150mm, 100mm dia) by chain pulley system including washing the pipe by water complete as direction of the Engineer-in-charge. |
| 150 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender