Housing Urban and Rular Development Government Departments Closing in 4 days TDR #58694988

Tender For Water Supply Arrangement Under Pwd(Dws), Ambassa Division During The Year 2026-27/Sh: Maintenance Of Ci/Di/Pvc Pipe Line In/C Construction Of Sluice Valve Chamber, Hydrant Post Platform Etc. Complete At Different Existing Dtw Schemes / Wat

Issued by Government Departments · Dhalai, Tripura
Tender Value
9.70 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
4 days left
EMD
19414
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dhalai → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Water Supply Arrangement Under Pwd(Dws), Ambassa Division During The Year 2026-27/Sh: Maintenance Of Ci/Di/Pvc Pipe Line In/C Construction Of Sluice Valve Chamber, Hydrant Post Platform Etc. Complete At Different Existing Dtw Schemes / Water Supply Schemes In Chjawmanu Rd Block Within The Jurisdiction Of Pwd(Dws), Chawmanu Sub- Division Under Pwd(Dws), Ambassa Division (Gr-I).

BOQ

Name of Work:- Water Supply Arrangement under PWD(DWS), Ambassa Division during the year 2026-27/SH: Maintenance of CI/DI/PVC pipe line in/c construction of Sluice Valve chamber, hydrant post platform etc. complete at different existing DTW schemes / Water Supply Schemes in Chjawmanu RD Block within the jurisdiction of PWD(DWS), Chawmanu Sub- Division under PWD(DWS), Ambassa Division (Gr-I).
Sl. No. Item Description
1Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge.A)For UPVC Pipe for new work a.In all kinds of soil
2For pipes not exceeding 90 mm dia
3For pipes exceeding 90 mm dia but not exceeding 300 mm dia
4Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. Class - 3 ( working pressure 6.0 kg / cm2)
540 mm OD
690 mm OD
7110 mm OD
8140 mm OD
9Providing and laying of flexible PVC pipe (conforming to IS:7634) complete including earth work as per specification and direction of the Engineer - in - charge (cost of fittings will be paid separately).
1015 mm dia.
1125 mm dia.
12Labour charges for repairing of leakage for CI/DI pipeline of various diameter by manual labour by hammering of old lead joints and other leakages of pipeline in/c excavation & refilling of the same as per direction of the Engineering-in-charge ( pig lead will be supplied by the department at free of cost).
13100 mm dia
14150 mm dia
15Charges for repairing of leakage in UPVC/HDPE pipe line with PVC coupler & solvent cement etc.in/c necessary earth excavation backfilling of soil as required after laying of pipeline , in layers not exceeding 200mm in dept in/c consolidating each deposited layer by ramming,watering etc.Complete as per specification & direction of Engineering-in-charge.
1690mm OD
17110 mm OD
18140 mm OD
19Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge. External work.
2040 mm dia. Nominal bore
2150 mm dia. Nominal bore
2265 mm dia. nominal bore
2380 mm dia. Nominal bore
24100 mm dia. Nominal bore
25Providing, fixing and laying fabricated UPVC socket / coupler confirming to IS:10124 (part-2) with solvent cement confirming to IS:14182 in/c testing of joints complete as per CPWD specification & direction of the Engineering-in-charge.
2690 mm dia
27110 mm dia
28140 mm dia
29Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge. (By manual means)
30Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
3140 mm dia
3290 mm dia
33110 mm dia
34140 mm dia
35Providing,fixing and laying fabricated UPVC straight reducer confirming to IS:10124 (part-3)with solvent cement confirming to IS:14182 in/c testing of joints complete as per chapter-20 of CPWD specification & direction of the Engineering-in-charge.
36110 x 90mm dia
37140 X 110 mm dia
38140 X 90 mm dia
39Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
4090 x 90 mm dia
41110 x 110 mm dia
42140 x 140 mm dia
43Providing, fixing and laying fabricated UPVC end cap confirming to IS:10124 (part-4) with solvent cement confirming to IS:14182 in/c testing of joints complete as per chapter-20 of CPWD specification and direction of the Engineering-in-charge.
4490mm dia
45110 mm dia
46140 mm dia
47Providing, fixing and laying flanged fabricated UPVC tailpiece with MS flange ( 8 mm thick ) conforming to IS : 10124 ( Part 6 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
4890mm dia
49110 mm dia
50140 mm dia
51Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge.
52i)15 mm dia
53Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge.
5440mm dia
5550mm dia
56Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
5740mm dia
5850 mm dia
5965mm dia
60Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
6150x40 mm dia
6280x40 mm dia
6380x50 mm dia
64Providing and fixing GI. Nipple of medium class as per chapter 20 of CPWD specification and direction of the Engineering-in-charge.
6515mm dia 150 mm long
6615mm dia 225 mm long
67Providing & fixing brass ferrule with C.I. cover confirming to IS:2692 in/c. boring & tapping the main as per chapter 20 of CPWD specification and direction of the Engineering-in –charge. 10mm nominal bore
68Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge.
6915 mm dia PVC /plastic bib cock
70Providing and fixing G.I. Full way valve as per CPWD specification and direction of the Engineer - in - charge.
7140mm dia
7250mm dia
73Providing and fixing U.P.V.C. service saddle as per CPWD specification and direction of the Engineer - in - charge.
7440 mm dia with 15 mm dia opening
7590 mm dia with 15 mm dia opening
76110 mm dia with 15 mm dia opening
77140 mm dia with 15 mm dia opening
78Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.
7980 mm P.N 1.6
80100 mm P.N 1.6
81125 mm P.N 1.6
82150 mm P.N 1.6
83Charges for fixing C.I. sluice valves with cap complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.
8480 mm dia PN-1.6
85100 mm dia PN-1.6
86125 mm dia PN-1.6
87150 mm dia PN-1.6
88Providing and fitting fixing PVC suction hose pipes of wall thickness 6 mm. as per relevant IS specification and direction of Engineer-in-charge.
89125 mm dia
90100 mm dia
91Providing and fitting fixing M.S. clamp for hose pipes with nuts & bolts complete as per relevant IS specification and direction of Engineer-in-charge.
92125 mm dia
93150 mm dia
94100 mm dia
95Providing and fitting fixing MS Foot valve as per relevant IS specification and the direction of the Engineer-in-charge.
9680 mm dia
97100 mm dia
98125 mm dia
99Providing and fixing C.I. non-return valve of approved quality as per of CPWD specification and direction of the Engineer - in - charge.
10065 mm nominal bore
10180 mm nominal bore
102100 mm nominal bore
103Providing & fitting fixing of MS flange ( 8 mm wall thickness ) by welding with G.I. / MS pipe and placing position as per specification and the direction of the Engineer-in-charge.
10450 mm dia
10565 mm dia
10680 mm dia
107100 mm dia
108125 mm dia
109150 mm dia
110Providing and fixing DI specials as per CPWD specification and direction of the Engineer - in - charge.G. D.I. Collar flanged socketted
111100 mm dia
112125 mm dia
113150 mm dia
114Labour charge for clearing of clouded deposited iron in the PVC pipe of 140,110,90 mm dia pipe by chain lead pully system in/c disposal of iron from the site and thoroughly washing the pipe with water complete as per direction of the Engineer-in-charge.
115Labour charge for clearing of deposited iron clouded in the CI pipeline of different dia (200mm, 150mm, 100mm dia) by chain pulley system including washing the pipe by water complete as direction of the Engineer-in-charge.
116Excavating holes upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil; as directed within a lead of 50 m and lift upto 1.5 m.-All kinds of soil
117Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil an disposal of surplus excavated soil as directed, within a lead of 50 m.-All kinds of soil
118Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compactingeach layer by using plate compactor or by any suitable method complete.
119Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size)
120Centering shuttering including struttings, propping etc. and removal of form work for:
121Foundations, footings, bases for columns etc. for mass concrete with timber plank
122Columns, piers, abutments, pillaras, posts and struts
123Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level:1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size)
124Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level.Thermo-Mechanically Treated bars/ Cold twisted deformed steel bars
125First class brick work in foundation and plinth including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ).
126Half brick masonry work with first class bricks in foundation and plinth including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand
12712 mm cement plaster of mixIn cement mortar 1 : 4 ( 1 cement : 4 fine sand )
1286 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand)
129Neat cement punning.
130Dismantling old C.I. /D.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at site lead upto 50 metre as per CPWD specification and direction of the Engineer-in charge.
131100 mm dia
132125 mm dia
133150 mm dia
134Charges for dismantling PVC / HDPE pipe after necessary excavation of earth including washing and stacking of pipes properly at site with all leads and lifts and backfilling of soil as required in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in-charge.
13590 mm dia
136100 mm dia
137140 mm dia
138Charges fordismantling PVC/HDPE pipe after necessary excavation of earth including washing and stacking of pipes properly at site with all lead sand lifts and back filling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in-charge.
13990 mm dia
140100 mm dia
141140 mm dia
142Charges for fixing and laying rigid UPVC pipes jointing with couplers,solvent cement including testing of joints complete (excluding the cost of pipes, couplers, solvent cement which are to be issued from the department free of cost and specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in charge.
14390 mm dia
144100 mm dia
145140 mm dia
146Charges for laying S&S Centrifugally Cast (Spun) Ductile Iron Class K-7 Pipes conforming to IS:8329 as per CPWD specification and direction of the Engineer - in - charge.
147100 mm dia
148125 mm dia
149150 mm dia Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58694988
AUTHORITY Government Departments
TENDER VALUE 9.70 Lakhs
LAST DATE 30-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Water Supply Arrangement Under Pwd(Dws), Ambassa Division During The Year 2026-27/Sh: Maintenance Of Ci/Di/Pvc Pipe Line In/C Construction Of Sluice Valve Chamber, Hydrant Post Platform Etc. Complete At Different Existing Dtw Schemes / Water Supply Schemes In Chjawmanu Rd Block Within The Jurisdiction Of Pwd(Dws), Chawmanu Sub- Division Under Pwd(Dws), Ambassa Division (Gr-I).
Basic Detail
Tender No 99/EE/PWD(DWS)/AMB/2026-27
Bidding Type Tender
Location
City Dhalai
State Tripura
Key Dates
Publish Date 23 Nov 2026
Submission Date 30 Nov 2026
Open Date 30 Nov 2026
Finance
Tender Value 9.70 Lakhs
Tender Fee 1000
EMD 19414
Exemption Not Available
Document List
17a61e22-a092-446c-8963-617be24d6da0.html
BOQ_80546.xls
DNIeT99.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.