Tender For Road Widening Work From Veer Durgadas Marg (Juna Somwariya) To Kartik Chouk, Ujjain
Tender Value
30.60 Crore
Estimated cost
Bid Submission
08 Dec 2026
12 days left
EMD
15.30 Lakhs
Bank guarantee accepted
Document Fee
50000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ujjain → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Road Widening Work From Veer Durgadas Marg (Juna Somwariya) To Kartik Chouk, Ujjain
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Lime Concrete, cement concrete grade M-10 and below |
| 2 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Concrete- Prestressed/Reinforced Cement Concrete Grade M -20 and above |
| 3 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Tile work/brick masonry — a) In lime mortar |
| 4 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Tile work/brick masonry — b) In cement mortar |
| 5 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Tile work/brick masonry — c) In Mud mortar |
| 6 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Stone Masonry — Rubble stone masonry in lime mortar |
| 7 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Stone Masonry — Rubble stone masonry in cement mortar |
| 8 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Stone Masonry — Rubble stone masonry in mud mortar |
| 9 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Stone Masonry — Dismantling stone pitching/dry stone spalls |
| 10 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Stone Masonry — Dismantling boulders laid in wire crates including opening of crates and stacking dismantled materials |
| 11 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — In Mud mortar |
| 12 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Steel work in all types of sections up to a height of 5 m above plinth level including dismembering |
| 13 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Scarping plaster in lime or cement mortar from brick/ stone masonry |
| 14 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Removing all type of R.C.C. Hume pipes and stacking within a lead up to 1000 meters including earthwork and dismantling of masonry works around pipes — Up to 600 mm dia |
| 15 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Removing all type of R.C.C. Hume pipes and stacking within a lead up to 1000 meters including earthwork and dismantling of masonry works around pipes — Above 600 mm to 900 mm dia |
| 16 | Dismantling of existing structures comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 metres, as per section 200 of the specification — Removing all type of R.C.C. Hume pipes and stacking within a lead up to 1000 meters including earthwork and dismantling of masonry works around pipes — Above 900 mm dia |
| 17 | Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 meters by manual means, stacking serviceable and unserviceable materials separately and Section 200 of the specifications. By Mechanical Means — Bituminous courses |
| 18 | Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 meters by manual means, stacking serviceable and unserviceable materials separately and Section 200 of the specifications. By Mechanical Means — Granular courses |
| 19 | Dismantling of cement concrete pavement i/c breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead upto 1000 meter, stacking serviceable and unserviceable materials separately and as per relevant clauses of section-200 |
| 20 | Dismantling of CI water pipe line up to 600 mm dia. including disposal with all lifts and lead up to 1000 meters and stacking of serviceable material and unserviceable material separately |
| 21 | Removal of Cement Concrete pipe of sewer gutter up to 1500 mm dia under the supervision of concerned department including disposal with all lifts and up to a lead of 1000 Meters and stacking of serviceable and unserviceable material separately but excluding earth excavation and dismantling of masonry works |
| 22 | Removal of telephone/electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to lead of 1000 meters and stacking the serviceable and unserviceable material separately |
| 23 | Transportation By Mechanical means including loading, unloading and stacking Earth — Upto 4 Km |
| 24 | Lime, moorum, building, rubbish — Upto 4 Km |
| 25 | Manure or sludge — Upto 4 Km |
| 26 | Barricading (1.6m high) Providing and fixing 1.6m high barricading during construction with 0.63mm thick GI sheets in double row fixed with 75mm dia. wooden ballies or 50mm dia. MS pipe buried in existing road sufficiently including painting with yellow and black bands by synthetic enamel paint as per the traffic norms and as directed by the Engineer in charge |
| 27 | Traffic Cone Red fluorescent with white reflective sleeve traffic cone made of low-density polyethylene (LDPE) material with a square base of 390 x 390 x 35 mm and a height of 770 mm, 4 kg in weight, as per specifications |
| 28 | Provision for Rehabilitation of Religious or other structures as per SOR Items |
| 29 | Provision for Drain Diversion works in order to make box culverts or cross drain slabs as per SOR items |
| 30 | Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead upto 1000m as per section-300 of the specification |
| 31 | Construction of Embankment/Sub-grade/Earthen Shoulders with material obtained from other sources, as per provisions of Section 305 of the specifications, with approved materials/soil confirming to requirements given in Table 301-1 of specifications including all lead and lifts, including cost of watering, compaction by vibratory roller/heavy pneumatic type roller etc. confirming to requirements given in Table 301-2 of the specifications complete |
| 32 | Crusher Run Macadam - Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicle, spreading and mixing with a motor grader, watering and compacting with a vibratory roller including all leads and lifts confirmimg to section 407 of specifications to form a layer of base .By Mixing Plant For 37.5 mm maximum size |
| 33 | Construction of Dry Lean Cement Concrete Sub- Base Over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600-1 of the specifications, cement content not to be less than 150 Kg/Cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with paver with electronic sensor/mechanical paver, compacting with 8-10 tonnes vibratory roller, finishing and curing and as per Section 601 of specifications |
| 34 | Construction of dowel jointed, plain Cement Concrete pavement in M -40 Grade Concrete over a prepared sub base with 43 or higher grade cement, coarse and fine aggregate conforming to IS:383 maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver with electronic sensor, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant debonding strip, placing of dowel bar and tie rod, admixtures as approved, curing compound, finishing to lines and grades as per approved drawings as per IRC:15 and as per Section -602 of the specifications complete but excluding cost of steel in dowel bar and tie rod etc |
| 35 | Mild Steel dowel bars confirming to IS 432, grade I |
| 36 | HYSD tie bars of Fe 500 grade confirming to IS 1786 |
| 37 | Providing and erecting direction and place identification retro reflectorized sign as per IRC:67 made of High Intensity grade sheeting as per Section 801.3 of specifications, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4 mm with area exceeding 0.9 Sqm fixed over back support frame of minimum 35 x 35 x 3 mm MS Angle mounted on two nos. of mild steel circular pipe 65 NB firmly fixed to the ground by means of properly designed foundation with M 25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing |
| 38 | Cable Duct Across the Road: Providing and laying of a reinforced cement concrete pipe(NP4) duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98 and approved drawings. Single Row for one utility service |
| 39 | Providing concrete cradle bedding in M -15 grade concrete as per Section 2900 and as per section 1700 and 2900 of the specifications |
| 40 | Providing and applying 2.5 mm including reflectorising glass beds @ 250 gm per Sqm area thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi-automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and as per Section 803 of specifications |
| 41 | Providing and fixing of Category-A Bi-directional Twin-Moulded Shank Raised Pavement Markers/ Road Stud made of Plastic body moulded from ASA (Acrylic styrene Cryometries) or HIP (High impact polystyrene) or ABS material. Lens shall be of plastic material. The marker shall have compressive strength of 13635 kg tested accordance with ASTM D4280 and shall have Flexural Strength of 909 kgf. Reflective panels shall consist of number of lenses containing Single or dual prismatic cubes capable of providing total internal reflection of light entering the lens face. The Slope or the retro-reflecting surface shall be 35 +/- 5 degree to the base and area of Each retro reflecting surface shall not be less than 13 sqcm. When impacted in accordance with 9.4.1 of ASTM D4280, the face of the lens shall show no more than two radial cracks longer than 6.4 mm (0.25 in.). There shall be no radial cracks extending to the edge of the abrasion resistant area. There shall be no delamination. Height of the marker shall not exceed 20 mm and its width shall not exceed 130 mm. Moulded shank RPM shall have the shank strength of 600 kgf. Head of the stud shall be Smooth and shall not present any sharp edges to traffic. RPM shall be of Category A with optical performance (Coefficient of Luminous Intensity- CIL) shall not be less than that given in Table 800-13 of the specifications for Bi-directional stud. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin-based adhesive. The bidder shall submit a prequalification warranty for Two years. Test certificate from an as per ASTM D 4280, Coefficient of Luminance Intensity-CIL as per table 800-13 of the specifications. Material, Marker Height, Colour, Slope of Reflecting Surface (Lens), Lens Impact strength, Resistance to temperature cycling, and Longitudinal Flexural Strength to be submitted |
| 42 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Foundations, footings, bases of columns, etc. For mass concrete |
| 43 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc |
| 44 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level Cement concrete grade M-15 (Nominal Mix) with 20 mm maximum size of stone aggregate |
| 45 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc. Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate |
| 46 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications and sections 1600 of the specifications. FE 500D/ FE 550/ FE 550D — Walls |
| 47 | Providing and fixing factory -made precast RCC U shape drain (FUJI) drain covers, having of strength not less than M -50 using Thermo -Mechanically Treated bars (TMT/TMX) FE 500D or more conforming to IS 1786 reinforcement bar (minimum 95 kg per cum) and cap able of carrying a wheel load of 5.0 Tones for heavy vehicle movement, of size Lid for U -300x300 mm. As per standard size reinforced with 8 mm dia. main- sectional T'M T. hoop bars, including providing 50 mm dia. perforations @ 2 nos. including providing edge binding with M.S. flats of sizes 50 mm x 1.60 mm complete, all as per direction of Engineer -in-charge |
| 48 | Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead up to 1000 m as per Section-300 of the specifications |
| 49 | Crusher Run Macadam - Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicle, spreading and mixing with a motor grader, watering and compacting with a vibratory roller including all leads and lifts confirmimg to section 407 of specifications to form a layer of base .By Mixing Plant For 37.5 mm maximum size |
| 50 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Foundations, footings, bases of columns, etc. For mass concrete |
| 51 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Suspended floors, roofs, landings, balconies and access platform — Top Slab |
| 52 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level Cement concrete grade M-15 (Nominal Mix) with 20 mm maximum size of stone aggregate |
| 53 | Providing and placing in position precast reinforced cement concrete U-shape drain as per design and shape, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland cement, admixtures as per IS: 456-2000 and standard like India standard, international standards viz. Japanese Industrial Standards (JIS)/ US standard/EU standard/ having of strength not less than M-50. Using Thermo- Mechanically Treated bars. (TMT/TMX) FE 500D or more conforming to IS 1786 reinforcement bar (minimum 95 kg per cum) and capable of carrying a wheel load of min 25 Tones for heavy vehicle movement. Rate includes all cost of material, labour charges at the plant, cost of reinforcement, formwork and lifting accessories, and transportation up to work at the site. making necessary holes of required sizes for carrying through service lines etc., providing steel hooks for lifting, etc. the work to be executed as per the direction of Engineer in- charge. Pre-Cast U Shape Drain 600x600 wall thick. 90 mm |
| 54 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate |
| 55 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications and sections 1600 of the specifications. FE 500D/ FE 550/ FE 550D — Top Slab |
| 56 | Providing and fixing factory -made precast RCC U shape drain (FUJI) drain covers, having of strength not less than M -50 using Thermo -Mechanically Treated bars (TMT/TMX) FE 500D or more conforming to IS 1786 reinforcement bar (minimum 95 kg per cum) and cap able of carrying a wheel load of 5.0 Tones for heavy vehicle movement, of size Lid for U -300x300 mm. As per standard size reinforced with 8 mm dia. main- sectional T'M T. hoop bars, including providing 50 mm dia. perforations @ 2 nos. including providing edge binding with M.S. flats of sizes 50 mm x 1.60 mm complete, all as per direction of Engineer -in-charge. Pre -Cast U Shape Drain Cover 600x600 mm — At every 6m |
| 57 | Earth work in excavation of foundation of structures with all lifts & lead up to 1000 meters as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per section 300 and 2100 of the specifications. Soil by Manual Means up to 3 m depth |
| 58 | Construction of granular sub-base, spreading in uniform layers with motor grader on prepared surface, mixing by Mix in Place Method at OMC and compacting with vibratory roller of 80-100 KN Static weight to achieve the desired density, including all lifts and lead complete in all respect as per Section-400 of the specifications. By Mix in Place Method - Grading IV |
| 59 | Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material likemechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed). 400mm Dia (8Kg/sq.cm) |
| 60 | Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead up to 1000 m as per Section-300 of the specifications |
| 61 | Supply of mineral aggregate like broken stone/crushed stone /stone dust/ moorum at road site including all lead and stacking etc. complete. Crusher stone dust |
| 62 | Construction of Embankment/Sub-grade/Earthen Shoulders with material obtained from other sources, as per provisions of Section 305 of the specifications, with approved materials/soil confirming to requirements given in Table 301-1 of specifications including all lead and lifts, including cost of watering, compaction by vibratory roller/heavy pneumatic type roller etc. confirming to requirements given in Table 301-2 of the specifications complete |
| 63 | Construction of Dry Lean Cement Concrete Sub- Base Over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600-1 of the specifications, cement content not to be less than 150 Kg/Cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with paver with electronic sensor/mechanical paver, compacting with 8-10 tonnes vibratory roller, finishing and curing and as per Section 601 of specifications |
| 64 | Providing and laying factory made Coloured Chamfered Edge Cement Concrete Paver Blocks of required strength, thickness and size/shape, made by table vibratory method using PU mould, laid in required colour and pattern over 50mm thick compac ted bed of stone dust, compacting and proper embedding/laying of inter locking paver blocks into the bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per req uired size and pattern, finishing and sweeping extra sand including locking edges with M 15 Cement Concrete in footpath, light traffic parking etc. complete as per direction of Engineer -in-Charge. 80mm thick C.C. paver block of M -40 grade with approved colour, design and pattern |
| 65 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Foundations, footings, bases of columns, etc. For mass concrete |
| 66 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc |
| 67 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level Cement concrete grade M-15 (Nominal Mix) with 20 mm maximum size of stone aggregate |
| 68 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc. Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate |
| 69 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications and sections 1600 of the specifications. FE 500D/ FE 550/ FE 550D — Walls |
| 70 | Providing and fixing factory-made precast RCC Ushape drain (FUJI) drain covers, having of strength not less than M-50 using Thermo-Mechanically Treated bars (TMT/TMX) FE 500D or more conforming to IS 1786 reinforcement bar (minimum 95 kg per cum) and capable of carrying a wheel load of 5.0 Tones for heavy vehicle movement, of size Lid for U-300x300 mm. As per standard size reinforced with 8 mm dia. main longitudinal & 6 mm no’s cross- sectional T'M T. hoop bars, including providing 50 mm dia. perforations @ 2 nos. including providing edge binding with M.S. flats of sizes 50 mm x 1.60 mm complete, all as per direction of Engineer-in-charge Pre-Cast U Shape Drain Cover 600x600 mm |
| 71 | Cable Duct Across the Road: Providing and laying of a reinforced cement concrete pipe(NP4) duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98 and approved drawings. Single Row for one utility service |
| 72 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:3 ( 1cement : 3 coarse sand) with joints finished flush with cement mortar 1:3. Red sand stone |
| 73 | Construction of Dowel jointed, Plain Cement Concrete Pavement in M-30 Grade Concrete over a prepared sub base with 43 or higher grade cement, coarse and fine aggregate conforming to IS:383 maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver with electronic sensor spreading the concrete by shovels, rakes compacted using needle, screed and plate vibrator and finished in a continuous operation including provision of contraction, expansion, and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, placing of dowel bar, tie rod admixtures as approved, curing compound, finishing to lines and grades as per approved drawings as per IRC:15 and as per Section-602 of the specifications complete excluding cost of steel in dowel bar and tie rod etc |
| 74 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications and as per Sections 1600 of the specifications. FE 500D/ FE 550/ FE 550D |
| 75 | Providing and Laying Reinforced cement concrete Hume pipe NP4 for culverts including fixing collar with cement mortar 1:2 excluding excavation bedding, protection works, backfilling, concrete and masonry work in head walls and parapets as per Section 2900 of the specifications — 1000 mm dia. , in single row |
| 76 | Providing and Laying Reinforced cement concrete Hume pipe NP4 for culverts including fixing collar with cement mortar 1:2 excluding excavation bedding, protection works, backfilling, concrete and masonry work in head walls and parapets as per Section 2900 of the specifications — 1200 mm dia. , in single row |
| 77 | Providing concrete cradle bedding in M-15 grade concrete as per Section 2900 and as per section 1700 and 2900 of the specifications |
| 78 | Supplying and drawing single core PVC insulated cable FR with copper multi strand conductor ISI marked in existing rigid conduit in surface or concealed as per specification — 3 X 2.5 sq mm |
| 79 | Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with two coat of enamel paint & provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) with frame work of angle iron / channel / bolted type construction duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere Metre, Volt Metre, selector switches, frequency Metre, phase indicating lamp, Energy Metre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere Metre, Volt Metre, selector switch as per approved design & specification |
| 80 | Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification — Digital Ampere Metre with CTs with selector switch |
| 81 | Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification — Digital Volt Metre with selector switch & HRC fuse |
| 82 | Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification — Frequency Metre |
| 83 | Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification — Aluminium bus bar strips with PVC sleeves |
| 84 | Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification — LED lamp indicator |
| 85 | MCCB with Breaking Capacity 25 KA at 415 V — Current Rating -25 to100 Amps & 70% -100% adjustable |
| 86 | MCCB with Breaking Capacity 25 KA at 415 V — Current Rating -160 Amps & 70% -100% adjustable |
| 87 | MCCB with Breaking Capacity 35 KA at 415 V — Current Rating - 160 Amps & Adjustable: 70% - 100% thermal & 5-10 times magnetic setting |
| 88 | MCCB with Breaking Capacity 35 KA at 415 V — Current Rating - 250 Amps & Adjustable: 70% - 100% thermal & 5-10 times magnetic setting |
| 89 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle, 10 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 : 2002 but without enclosures — MCB SP 6Amp to 32Amp 10kA rating |
| 90 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle, 10 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 : 2002 but without enclosures — MCB DP 6Amp to 32Amp 10kA rating |
| 91 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle, 10 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 : 2002 but without enclosures — 6 Amp to 32 Amp Rating |
| 92 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle, 10 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 : 2002 but without enclosures — MCB FP For 50 Amp to 63 Amp Rating |
| 93 | Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked) for cable laid underground with necessary material and at required depth upto 90cm. below road/ground surface, including excavation, back filling with excavated material, ramming and making the surface good — 50.00mm outside dia |
| 94 | Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked) for cable laid underground with necessary material and at required depth upto 90cm. below road/ground surface, including excavation, back filling with excavated material, ramming and making the surface good — 110.00mm outside dia |
| 95 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor. ARMOURED 4 CORE — 10 sq. mm |
| 96 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor. ARMOURED 4 CORE — 150 Sq.mm.(XLPE) |
| 97 | Laying of one number PVC insluated and PVC sheated power cable of 1.1kV grade of size not exceeding 25Sq.mm direct in ground including excavation, sand cushioining, protective covering and refilling the pit etc. as required |
| 98 | Laying of one number PVC insluated and PVC sheated power cable of 1.1kV grade of size exceeding 120 Sq.mm but not exceeding 400 Sq.mm direct in ground including excavation and cushioning protective covering and refilling the pit etc. as required |
| 99 | Providing and fixing earthing arrangement with 16mm dia 2.5 metre long galvanized iron or steel rod electrode including packing of charcoal powder and salt as per specification watering pipe 19mm dia G.I. connection, etc. complete with refilling the pit as required, but excluding the excavation of earth pit |
| 100 | Providing and fixing 25mm X 5mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required |
| 101 | Supplying and laying 6 SWG G.I. wire at 0.5 Meter below ground level as conductor earth electrode including soldering etc. as required |
| 102 | Add Extra for using salt and charcoal/coke for G.I. Plate or Copper plate earth electrode as required including excavation & refilling |
| 103 | Brass compression gland. Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, rubber ring complete erected with cable and lead connection etc. as per specification complete — Gland size 22mm suitable for cable 2/3, 3½, 2/4 x 10 sq. mm or 2x 16 sq. mm |
| 104 | Brass compression gland. Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, rubber ring complete erected with cable and lead connection etc. as per specification complete — Gland Size 50 mm suitable for cable 3½ x 150 Sq.mm OR 3 x 185 Sq.mm |
| 105 | Supplying and fixing ferrules (Aluminium in Line connector) as per IS specification suitable for following size of cable with Aluminium stranded / solid conductor evenly crimped with high pressure tool including connection as required complete — 2.5 to 6.00 sq. mm |
| 106 | Supplying and fixing ferrules (Aluminium in Line connector) as per IS specification suitable for following size of cable with Aluminium stranded / solid conductor evenly crimped with high pressure tool including connection as required complete — 10.00 sq. mm |
| 107 | Supplying and fixing crimping type alum. lugs as per I.S.S. specification suitable for following size of cable with alu./copper solid/stranded conductor evenly crimped with high/pressure tool and connected to switch gear/bus/M.C.C.B./M.C.B. etc. as required complete — 6 -16 sq. mm |
| 108 | Supplying and fixing crimping type alum. lugs as per I.S.S. specification suitable for following size of cable with alu./copper solid/stranded conductor evenly crimped with high/pressure tool and connected to switch gear/bus/M.C.C.B./M.C.B. etc. as required complete — 25 sq. mm |
| 109 | Supplying and fixing crimping type alum. lugs as per I.S.S. specification suitable for following size of cable with alu./copper solid/stranded conductor evenly crimped with high/pressure tool and connected to switch gear/bus/M.C.C.B./M.C.B. etc. as required complete — 35 sq. mm |
| 110 | Supplying and fixing crimping type alum. lugs as per I.S.S. specification suitable for following size of cable with alu./copper solid/stranded conductor evenly crimped with high/pressure tool and connected to switch gear/bus/M.C.C.B./M.C.B. etc. as required complete — 150 Sq.mm |
| 111 | Supplying & fixing pin terminal lugs as per ISS specification suitable for cable evently cramped with high pressure tool & connection to switch gear terminal. Copper lugs tube type — Upto 16 sq. mm conductor size |
| 112 | Providing and erecting 9mtrs.High hot dipped galvanized octagonal poles with bottom of 200mmA/F,top100mm,A/F made from 3mm thick HT plate & 290x290x16mm base plate with 1500mm long decorative sword type double arm bracket complete ererted in an approved manner on provided foundation.Suitable size & type of foundation bolts.4nos.bolts type M20x750mm 'J' type foundation bolts (EN8 grade) |
| 113 | Providing and fixing of sword canopy type single arm GI bracket upto 2 Mtr. Long for 70mm A/F top octagonal pole |
| 114 | Providing and fixing of sword canopy type double arm GI bracket upto 2 Mtr. Long for 70mm A/F top octagonal pole |
| 115 | Supplying of street light with high power LED of 1 to 3 W each assembled on single MCPCB, system lumens output with efficacy>110 lm/W. luminiare having color temp 6500K & 50000 burning hrs life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF 0.95 & surge protection 4KV. Housing made of pressure die cast aluminium with heat resistant flat glass / Lens type, IP66 protection. Submission LM 80-08 Form LED Source Manufacturer & LM7908 / IS16106 from NABL approved lab. Manufacturer manadatory i/c 50mm.dia G.I. Pipe bracket upto 2 mtr. long in required angle/shape, connection lead, testing etc to complete the job. 2 Yrs Guarantee certificate from manufacturer. 150W |
| 116 | Astro Time Switch-For lights On – Off based on Sunrise & Sunset timing Supply, installation, testing and commissioning of Astro - Time Switch based on Astro program i.e. calculation of sunrise and sunset times through date, time and Indian PIN Codes. It shall have an option of Astro ON period override by time switch and Offset function which allows programming of switching times Offset from the astronomic time. The 230 V AC operated Astro Time Witch shall have an operating range of 96...253V AC with 1 NO, 16 A, AgSn02 Contact material with Starting current of 120A and 1 CO cadmium Free contacts, it shall have LCD status indication with back light display along with internal easily replaceable battery on the front side for setup and programming. The electrical life at rated load AC1 shall be 1 Lakh cycles and shall work at an ambient temperature of -20 to +50 deg C. It shall have a dielectric strength between supply and open contacts of 4000V AC, between open contacts 1000V AC respectively and rated impulse voltage (between supply and contacts) of 6kV and rated impulse voltage (between open contacts) of 1.5kV. The mounting shall be on 35 mm DIN rail (EN 60715) and shall have necessary approvals like CE, IMQ and EAC |
| 117 | Modular Contactor for the lighting Feeder Panel Supply, installation, testing and commissioning of 25A rating Four pole contactor, designed Specific contact material AgSnO2 for lamp loads and Ac Load for high starting current. It shall work at an ambient temperature of 20 to +50 deg C and Auto-On Off selector version. It shall have 3 Kv short circuit protection. The mounting shall be on 35mm DIN rail (EN 60715) |
| 118 | Designing & casting with M-20 cement concrete foundation suitable for 9 mtrs. Octagonal poles considering the safe soil bearing capacity at site as 10 T/sqm at 2 mtrs. Depth including excavation, foundation nut bolts in an approved manner |
| 119 | Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including all lift and lead up to 50 m. Disposed earth to be levelled and neatly dressed. All kinds of soil |
| 120 | Construction of Embankment/Sub-grade/Earthen Shoulders with material obtained from other sources, as per provisions of Section 305 of the specifications, with approved materials/soil confirming to requirements given in Table 301-1 of specifications including all lead and lifts, including cost of watering, compaction by vibratory roller/heavy pneumatic type roller etc. confirming to requirements given in Table 301-2 of the specifications complete |
| 121 | Crusher Run Macadam - Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicle, spreading and mixing with a motor grader, watering and compacting with a vibratory roller including all leads and lifts confirmimg to section 407 of specifications to form a layer of base .By Mixing Plant For 37.5 mm maximum size |
| 122 | Construction of Dry Lean Cement Concrete Sub- Base Over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600-1 of the specifications, cement content not to be less than 150 Kg/Cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with paver with electronic sensor/mechanical paver, compacting with 8-10 tonnes vibratory roller, finishing and curing and as per Section 601 of specifications |
| 123 | Construction of Dowel jointed, Plain Cement Concrete Pavement in M-30 Grade Concrete over a prepared sub base with 43 or higher grade cement, coarse and fine aggregate conforming to IS:383 maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver with electronic sensor spreading the concrete by shovels, rakes compacted using needle, screed and plate vibrator and finished in a continuous operation including provision of contraction, expansion, and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, placing of dowel bar, tie rod admixtures as approved, curing compound, finishing to lines and grades as per approved drawings as per IRC:15 and as per Section-602 of the specifications complete excluding cost of steel in dowel bar and tie rod etc |
| 124 | Providing and laying Hand dressed cobble stone flooring of size 150x150x150mm (average) over 20 mm (average) thick base of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry including pointing in white cement mixed with pigment of matching shade complete., Joints between stones should be less than 12 mm. pattern & design as per architectural drawing |
| 125 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering All work up to plinth level. Cement concrete gradeM-15 (Nominal Mix) with 20 mm maximum size of stone aggregate |
| 126 | Providing and laying in position machine batched and machine mixed and machine vibrated design mix cement concrete of M-25 grade mixed in a concrete mixer of not less than 0.2 cum capacity and approporiate weigh batcher using approved mix design, for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement. including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of ngineer-in-charge. Upto Plinth level |
| 127 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Foundations, footings, bases of columns, etc. For mass concrete |
| 128 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Lintels, beams, plinth beams, girders, bressumers and cantilevers — Beam |
| 129 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc |
| 130 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete. Thermo-Mechanically Treated bars. (Fe 500 D or more) — 150 Kg/ Cum of RCC |
| 131 | Stone work in plain ashlar masonary in super structure upto floor two level in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing with cement mortar 1:2 (1 white cement : 2 Marble dust) with an admixture of pigment matching the stone shade : One face dressed. White sand stone — Curtain Wall |
| 132 | Stone work (machine cut edges) for wall lining etc. (veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 ement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 Marble dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid separately) : White sand stone - Exposed face machine cut and table rubbed with rough backing. 70 mm thick |
| 133 | Providing and fixing 16mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm |
| 134 | Supplying, stacking and spreading of good earth for plantation at site including royalty and carriage earth measured in stacks will be reduced by 20% for payment |
| 135 | Supplying, stacking and spreading compost/manure from approved source, (manure measured in stacks will be reduced by 8% for payment) |
| 136 | Shrubs Bahunia Tomentosa, Beloperone Species, Caselpinnia Pulcherima, Bird of Paradise, Callandra Emarginata, Callandra Hybrida, Cassia Bi flora, Cassia Laevigata, Cestrum Nocturnum, Dombeya Mastersii, Euphorbia Caracasana, Euphorbia Pulcherima, Excorea bi color, Excorea tri color, Ficuas Blackii, Ficus Reginold, Ficus Panda, Gardenia, Gulphinia, Jasminoides, Hamelia Pattens, Heliconia, Hibiscus Rosasinensis, Hibiscus Verigated, Hibiscus Viceroy, Jatropha Multifida, Largestomia Indica, Malpighia Coccigera, Murraya Exotica, Murraya Koeniggi, Murraya Sambucum, Mussaenda Erythrophylla, Nerium Oleander, Nyctanthus Arbortristis, Plumbego Capensis, Putranjeeva Roxburghii, Tabernaemontana Coronaria, Tabernaemontana Divaricata, Tecoma Gaudi Chaudi, Tecoma Stans, Thevetia Nerifolia, Thuja Compacta and equivalent plants |
| 137 | Allamanda Cathartica, Allamanda Grandiflora, Allamanda Violacea, Begnonia Venustha, Boughan Villas (Variety : Butiana, Lady Mary Bearing, Mahaara, Mohan, Scarlet Queen Variagata, Glabra Formosa, Peruviana Odissi, Partha, Shubhra, Thimma, Spectabillis, L.N. Birla, Refulgens), Clerodendrum Splendens, Clerodendrum Thompsonae, Ipomea Purpurea, Jasminum Grandiflorum, Jasminum Humile (Yellow), Passiflora Caerulea (Rakhi Bel), Petrea Volubilis, Quis Qualis Indica, Tecoma Grandiflora, Veronia Elaegnifolia (Curtain Creeper), Mandvellia, Garlic Creeper, Callimitis |
| 138 | Ground cover plants height: 30cm-45cm Alpinia Verigated, Alternanthera species, Aspyragus Myerri, Aspyragus Springenii, Aspidistra, Canna (regular, Dwarf), Chlorodendron Inermii, Chlorophytum (Green), Chlorophytum verigated, Coffea Chinensis, Dianella Verigated, Durranta (Goldiana, Green, Verigated), Euphorbia Milli hybrid, Ipomea (Golden leaves), Iresine herbstii, Juniper Prostata, Juniper Africana, Ophiopogon plant, Ophiopogon jaburan, Portulacaria Afra (jade Plant), Schefflera Green, Schefflera verigated, Setcreasea Purpurea, Syngonium (Butterfly) species, Syngonium miniature, Syngonium Dwarf, Syngonium variegated, Tradescantia, Wadelia Trilobata, Zebrina Tradescantia, Pendanas, Spider Lily Black, Spider Lily verigated, Aclypha (Red, Green,Mini), Lantana (Red, Yellow, Purple, White, verigated), Haemalia Mini and similar plants |
| 139 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 sand) |
| 140 | Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @3.28 ltr/10sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 141 | Providing and fixing chicken mesh as per ISI specificationand in the required width with 50mm long Bombay nails on vertical and horizontal junctions of RCC and brickwall including scaffolding and all lead and lift etc. complete before plastering upt 10 meter height |
| 142 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 143 | Providing and laying at or near ground level Pre-cast kerb stone of M-25 grade in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement:3 coarse sand) thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required complete as per direction of Engineer-in-Charge |
| 144 | Providing and erection of 16 meter high mast lighting system suitable to install upto 10 No. 150 w LED flood light and control gear with integral power tool, weight 450 kg. comprising of 2 sections of hot dipped galvanized materials as per BSEN ISO 1461 thickness 3 mm & 4 mm, dia 150mm & 360mm for top and bottom respectively, stress fitting arrangement on site with 500 mm overlap dynamic loading to withstand max wind pressure as per -IS 875 part III, parameters for structural & foundation design must be taken from wind tunnel test. Lightningprotection of GI single spike 1200 mm at top and at base inside compartment having double internal lock with adequate size of MCB erected on PVC board complete with base plate of25mm thick 520 mm dia. and foundation bolts having 6 nos. bolts of 24mm dia 750 mm long(EN.8 grade) anchor plate 445 PCD, including accessories viz. (1) Lantern carriage of 50 NB ERW class-B, MS pipe covered with PVC sleeve suitable tocarry 500kg. load and upto 8 fittings symmetrically. (2) Trailing copper cable 5x2.5 sq.mm, PVC insulated PVC Sheathed (3) Double drum 350Kg Winch having gear 53:1, oil bath (SAE90/140) arrangement (4) 2 nos — Stainless steel wire ropes 5 mm dia (7/19) breaking load capacity 1450 kg x 2, (5) Integral power tool 3-phase, 0.75HP 2m/min single speed .torque limiter upto 500 kg adjustable (6) Single LED 300 Nos. aviation light (7) Feeder pillar fabricated out of 14 SWG CRCA sheet and comprise of incoming MCB 32 A TPN switch, HRC fuses, single dial timer, suitable size of contactors for lighting and power tool, 2 nos. outgoing, reversing switch for motor. (8) Foundation drawing, test certificate and guarantee certificate shall be provided by manufacturer. (without fixture and lamp) |
| 145 | Designing & casting of Open raft shallow footing foundation with M-20 cement concrete suitable for 16 mtrs. High Mast considering the safe soil bearing capacity at site as 10 T/sqm at 2 mtrs. Depth including excavation, foundation nut bolts in an approved manner |
| 146 | Supplying of street light with high power LED of 1 to 3 W each assembled on single MCPCB, system lumens output with efficacy>110 lm/W. luminiare having color temp 6500K & 50000 burning hrs life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF 0.95 & surge protection 4KV. Housing made of pressure die cast aluminium with heat resistant flat glass / Lens type, IP66 protection. Submission LM 80-08 Form LED Source Manufacturer & LM7908 / IS16106 from NABL approved lab. Manufacturer manadatory i/c 50mm.dia G.I. Pipe bracket upto 2 mtr. long in required angle/shape, connection lead, testing etc to complete the job. 2 Yrs Guarantee certificate from manufacturer. 150W |
| 147 | Supplying of integral post top lantern LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired up to terminal block. LED of 1 to 3W each assembled on single MCPCB, having color temp6500K & having 50000 burning hrs life with minimum @ L70, system lumen output should be minimum with efficacy>80lm/W. LED driver PF 0.95 & surge protection 2KV. The colour rendering index of LED light should be more than70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory. i/c connection wire, testing etc. to complete thejob. 2 Yrs Guarantee certificate from manufacturer. 40W |
| 148 | Decorative designer poles Providing and erection of black painted galvanized decorative designer poles in different section, top 60mm dia., bottom 140mm dia. with gold colour painted ornamental cast aluminium ring having lockable weather proof flush door junction box in bottom section, base plate dia. 290mm having 4 holes of 22mm dia. complete erected in an approved manner on existing foundation. Suitable size & type of foundation bolts 4 nos. X 16mm X 450mm 'J' type (EN8 grade) 5m height |
| 149 | Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE confirming to IS 4984/ 14151/ 12786/ 13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/Hydraulic Jacks/ But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed) — 160 mm dia |
| 150 | Providing and laying Bend 45 confirming to IS specifications — 160 mm dia |
| 151 | Providing butt fusion welded joint/jointing by heating to the ends with the help of Teflon coated electric mirror/heater ends together etc. by thermosetting process to HDPE Pipe and specials. (6kg, 8kg, 10kg) (50mm & above fusion jointed & below 50mm mechanical jointed) — 160 mm dia |
| 152 | Providing and laying End Cap confirming to IS specifications — 20 mm dia |
| 153 | Providing and laying End Cap confirming to IS specifications — 160 mm dia |
| 154 | Providing, Supplying and laying Blue MDPE (medium density polyethylene) pipes conforming to ISO 4427:1996 manufactured from virgin resin PE 80 Food grade compounded Raw Material having Blue Colour only with quality assurance certificate from quality agencies like CIPET (India) and other recognised agencies for usage in Drinking Water System. The cost shall include testing of all materials, Inspection charges, transportation upto site, transit insurance, loading, unloading, stacking etc. complete — PN 16 (SDR 9) — 20mm dia |
| 155 | Providing, Supplying and fixing of Electro Fusion Tapping Ferrule (Branch Tapping Saddle) female BSP Threaded with SS 304 insert fittings in accordance with BS EN 12201 : Part-3 suitable for drinking water with in black/blue colour manufactured from compounded PE80/PE 100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR 11 with min PN 12.5 rated for water application. The cost such as testing, inspection charges, transportation upto site, transit insurance,loading, unloading, stacking etc. all complete — 160x20mm |
| 156 | Providing, Supplying and fixing of Compression fittings, PN16 rated in conformation to ISO:14236-2000 and shall be tested as per ISO:3459, ISO : 3501 & ISO: 3503, suitable for drinking water & approved by certified agencies, in food grade polypropylene and shall be inclusive of all cost of inspection charges, transportation up to site, transit insurance,loading, unloading, stacking etc. complete — Metal inserted Compression Female Threaded Adaptor with SS 304 Material — 20x15mm |
| 157 | Providing, Supplying and fixing of Compression fittings, PN16 rated in conformation to ISO:14236-2000 and shall be tested as per ISO:3459, ISO : 3501 & ISO: 3503, suitable for drinking water & approved by certified agencies, in food grade polypropylene and shall be inclusive of all cost of inspection charges, transportation up to site, transit insurance,loading, unloading, stacking etc. complete — Metal inserted Compression Male Threaded Adaptor with SS 304 Material — 20x15mm |
| 158 | Taking exploratory boring 100 mm dia. at the locations of pier and abutments or for high embankments in approaches in all type of strata as per IRC:78 and Section 2400 of the specifications. Up to 1.0 m below bed level |
| 159 | Taking exploratory boring 100 mm dia. at the locations of pier and abutments or for high embankments in approaches in all type of strata as per IRC:78 and Section 2400 of the specifications. Beyond 1.0 m depth up to 5.0 m |
| 160 | Taking exploratory boring 100 mm dia. at the locations of pier and abutments or for high embankments in approaches in all type of strata as per IRC:78 and Section 2400 of the specifications. Beyond 5.0 m depth |
| 161 | Earth work in excavation of foundation of structures with all lifts & lead up to 1000 meters as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per section 300 and 2100 of the specifications. Soil by mechanical means up to 3 m depth |
| 162 | Providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing and specifications as per sections 1200 and 1900 of the specifications. Taken for 6 mm liner, 8 m per pile (1200 mm dia, 0.1784 t/m). Nearest ISSR item - pile liner not listed |
| 163 | Providing bored cast-in-situ M-35 grade R.C.C. pile (1200 mm dia.) excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead up to 1000 m. and as per 1100, 1600 and 1700 of the specifications |
| 164 | Dynamic Pile load test Conducting Dynamic pile load test on routine pile IRC:78 Appendix-6 (Part-I) |
| 165 | Providing and laying Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification and as per sections 1100, 1500 & 1700 of the specifications with RCC Grade M35 |
| 166 | Levelling course for Pile cap PCC in M-15 below Pile cap asper drawing and as per section 1100 and 1700 of the specifications |
| 167 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications and as per Sections 1600 of the specifications. FE 500D/ FE 550/ FE 550D. As per BBS sheet |
| 168 | Providing and laying Plain/Reinforced cement concrete in sub-structure as per drawing and sections 1500, 1700 & 2200 of the specifications. RCC Grade M35 (height 5 to 10 m) |
| 169 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Sections 1600 of the specifications. FE 500D/ FE 550/ FE 550D. As per BBS sheet |
| 170 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia. AC/PVC/HDPE pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing, technical specifications and as per Section 2706 of the specifications |
| 171 | Providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in Section 2504 of the specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications |
| 172 | Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) section IX and Section 2005 of the specifications complete including all accessories as per drawing and Technical Specifications |
| 173 | Providing and laying Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification and as per Sections 1500, 1700 and 2300 of the specifications. RCC/PSC Grade M35 with 20 mm maximum size of aggregate, for solid slab super-structure, height beyond 5 m and up to 10 m (deck soffit 476.705 vs GL 471.66) |
| 174 | Providing and fixing Helical pipes, Galvanised steel sheet metal in voided concrete slabs including 20mm dia. tie rod and sealing joints etc. as per Section 1700 and 1800 of the specifications. 600 mm dia |
| 175 | Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications. FE 500D/ FE 550/ FE 550D. As per BBS sheet |
| 176 | Providing and laying Cement concrete wearing coat M-30 grade including cost of reinforcement complete as per drawing and Technical Specifications and as per Sections 1500, 1700 and Clause 2702 of the specifications |
| 177 | Providing, fixing and erecting 40 mm dia. steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 0.95 meters high above ground, 1.8 m centre to centre, complete as per approved drawings |
| 178 | Providing & fitting 100mm dia Galvanised steel Drainage Spouts complete as per Section 2705 of the specifications and as directed by the Engineer |
| 179 | Providing PCC M15 (with 40 mm maximum size of aggregate) Grade levelling course below approach slab complete as per drawing and technical specification and as per relevant Sections of Section 1700 of the specifications |
| 180 | Providing and laying Reinforced cement concrete approach slab in M-30 grade concrete including formwork excluding cost of reinforcement complete as per drawing and technical specification |
| 181 | Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications. FE 500D/ FE 550/ FE 550D. Approach slab 12Φ @150 top & bottom both ways (Dwg MISC/AS/06B). As per BBS sheet |
| 182 | Providing and laying of a strip seal expansion joint catering to maximum horizontal movement up to 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation |
| 183 | Testing of span of bridge for deflection due to live load with platforms for loading arrangements, apparatus for measurements including unloading etc complete as per approved drawing and as directed by Engineer |
| 184 | Taking exploratory boring 100 mm dia. at the locations of pier and abutments or for high embankments in approaches in all type of strata as per IRC:78 and Section 2400 of the specifications. Up to 1.0 m below bed level |
| 185 | Taking exploratory boring 100 mm dia. at the locations of pier and abutments or for high embankments in approaches in all type of strata as per IRC:78 and Section 2400 of the specifications. Beyond 1.0 m depth up to 5.0 m |
| 186 | Taking exploratory boring 100 mm dia. at the locations of pier and abutments or for high embankments in approaches in all type of strata as per IRC:78 and Section 2400 of the specifications. Beyond 5.0 m depth |
| 187 | Earth work in excavation of foundation of structures with all lifts & lead up to 1000 meters as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per section 300 and 2100 of the specifications. Soil by mechanical means up to 3 m depth |
| 188 | Levelling course for Pile cap PCC in M-15 below Pile cap asper drawing and as per section 1100 and 1700 of the specifications |
| 189 | Providing steel liner 10 mm thick for curbs and 6mm thick for steining of wells including fabricating and setting out as per detailed drawing and specifications as per sections 1200 and 1900 of the specifications. Taken for 6 mm liner, 7.5 m per pile. Nearest ISSR item - pile liner not listed |
| 190 | Providing bored cast-in-situ M-35 grade R.C.C. pile (1000 mm dia.) excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead up to 1000 m and as per 1100, 1600 and 1700 of the specifications |
| 191 | Providing and laying Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification and as per sections 1100, 1500 & 1700 of the specifications with RCC Grade M35 |
| 192 | Dynamic Pile load test Conducting Dynamic pile load test on routine pile IRC:78 Appendix-6 (Part-I) |
| 193 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications and as per Sections 1600 of the specifications. FE 500D/ FE 550/ FE 550D. As per BBS sheet |
| 194 | Providing and laying Plain/Reinforced cement concrete in sub-structure as per drawing and sections 1500, 1700 & 2200 of the specifications. RCC Grade M35 |
| 195 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Sections 1600 of the specifications. FE 500D/ FE 550/ FE 550D. As per BBS sheet |
| 196 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia. AC/PVC/HDPE pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing, technical specifications and as per Section 2706 of the specifications |
| 197 | Providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in Section 2504 of the specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications |
| 198 | Providing & fixing 20 mm thick & 25cm deep compressible fibre board in expansion joint complete as per drawing & Technical Specifications |
| 199 | Providing and laying Reinforced cement concrete in super-structure. RCC Grade M35 with 20 mm maximum size of aggregate, solid slab, height up to 5 m (kerb for pipe railing) |
| 200 | Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications. FE 500D/ FE 550/ FE 550D. Kerb @ 110 kg/cum (no bar detail on drawing) |
| 201 | Providing, fixing and erecting 40 mm dia. steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 0.95 meters high above ground, 1.8 m centre to centre, complete as per approved drawings |
| 202 | Temporary sheet pile wall (steel sheet piles driven to retain soil and ground water during construction, extracted and reused after completion). Lump-sum rate as submitted - needs rate analysis |
| 203 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications and as per Sections 1600 of the specifications. FE 500D/ FE 550/ FE 550D. Piles as GAD pile; cap at GAD cap steel per cum |
| 204 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Sections 1600 of the specifications. FE 500D/ FE 550/ FE 550D. At GAD stem steel per cum |
| 205 | Earth work in excavation of foundation of structures with all lifts & lead up to 1000 meters as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per section 300 and 2100 of the specifications. Soil by mechanical means up to 3 m depth |
| 206 | Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications. PCC Grade M15 (drawing: 100 mm levelling course, M10 in notes / M15 on section) |
| 207 | Providing and laying Plain/Reinforced cement concrete in sub-structure as per drawing and sections 1500, 1700 & 2200 of the specifications. RCC Grade M30 (drawing note 4: RCC M-30) |
| 208 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Sections 1600 of the specifications. FE 500D/ FE 550/ FE 550D (drawing: TMT-500). Bar-by-bar in part C |
| 209 | Providing and fixing in position pre moulded compressible filler board made from polymer base in black color, 25 mm thick, in expansion joints, including double sided adhesive tape and sealant |
| 210 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia. AC/PVC/HDPE pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing, technical specifications and as per Section 2706 of the specifications |
| 211 | Providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in Section 2504 of the specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications |
| 212 | Dewatering of water caused by springs, tides or river seepage, broken water mains or drains or well or another similar situation |
| 213 | Earth work in excavation of foundation of structures with all lifts & lead up to 1000 meters as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per section 300 and 2100 of the specifications. Soil by Meachanical Means upto 3m Depth |
| 214 | Crusher Run Macadam - Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicle, spreading and mixing with a motor grader, watering and compacting with a vibratory roller including all leads and lifts confirmimg to section 407 of specifications to form a layer of base .By Mixing Plant For 37.5 mm maximum size |
| 215 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plate or plywood shuttering for : — Foundations, footings, bases of columns, etc. For mass concrete |
| 216 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plate or plywood shuttering for : — Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc |
| 217 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level Cement concrete grade M-15 (Nominal Mix) with 20 mm maximum size of stone aggregate |
| 218 | Supplying, fitting and placing HYSD bar reinforcement in sub -structure complete as per drawing and Sections 1600 of the specifications. FE 500D/ FE 550/ FE 550D — S5 - Distribution Steel at Non Earth Face - 10mm bar @ 200mm c/c — Reinforcement for 10m |
| 219 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site on work in transit mixer for all leads, having continous aggitated mixer, manufactuer as per mix design of specified grade for reinforced cement work, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement. including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Upto Plinth level — Retaining Wall 10m |
| 220 | Providing M-30 grade concrete instead of M-25 grade RMC |
| 221 | Providing and fixing in position pre moulded compressible filler board made from polymer base in black color approved make conforming to the specifications having minimum density of 95 kg / cum, non staining, with less than 1 percent water absorption and compression recovery of 93 percent minimum including cost of double sided adhesive tape, sealant etc. in expansion joints. 25 mm thick |
| 222 | Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/ return wall with 100mm dia AC/PVC/HDPE pipe, extending through the full width of the structure with slope of 1V:20H towards drawing force. Complete as per drawing and Technical specifications and as per clause 2706 of specifications — at every 1 meter interval (2 Nos at each interval) |
| 223 | Providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in Section 2504 of the specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications |
| 224 | Dewatering of water caused by springs, tides or river seepage, broken water mains or drains or well or another similar situation |
| 225 | Construction of Embankment/Sub-grade/Earthen Shoulders with material obtained from other sources, as per provisions of Section 305 of the specifications, with approved materials/soil confirming to requirements given in Table 301-1 of specifications including all lead and lifts, including cost of watering, compaction by vibratory roller/heavy pneumatic type roller etc. confirming to requirements given in Table 301-2 of the specifications complete |
| 226 | Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead upto 1000m as per section-300 of the specification (9 m service road) |
| 227 | Construction of Embankment/Sub-grade/Earthen Shoulders with material obtained from other sources, as per provisions of Section 305 of the specifications, with approved materials/soil confirming to requirements given in Table 301-1 of specifications including all lead and lifts, including cost of watering, compaction by vibratory roller/heavy pneumatic type roller etc. confirming to requirements given in Table 301-2 of the specifications complete (9 m service road) |
| 228 | Crusher Run Macadam - Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicle, spreading and mixing with a motor grader, watering and compacting with a vibratory roller including all leads and lifts confirmimg to section 407 of specifications to form a layer of base .By Mixing Plant For 37.5 mm maximum size (9 m service road) |
| 229 | Construction of Dry Lean Cement Concrete Sub- Base Over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600-1 of the specifications, cement content not to be less than 150 Kg/Cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with paver with electronic sensor/mechanical paver, compacting with 8-10 tonnes vibratory roller, finishing and curing and as per Section 601 of specifications (9 m service road) |
| 230 | Construction of dowel jointed, plain Cement Concrete pavement in M -40 Grade Concrete over a prepared sub base with 43 or higher grade cement, coarse and fine aggregate conforming to IS:383 maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver with electronic sensor, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant debonding strip, placing of dowel bar and tie rod, admixtures as approved, curing compound, finishing to lines and grades as per approved drawings as per IRC:15 and as per Section -602 of the specifications complete but excluding cost of steel in dowel bar and tie rod etc (9 m service road) |
| 231 | Mild Steel dowel bars confirming to IS 432, grade I (9 m service road) |
| 232 | HYSD tie bars of Fe 500 grade confirming to IS 1786 (9 m service road) |
| 233 | Cable Duct Across the Road: Providing and laying of a reinforced cement concrete pipe(NP4) duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98 and approved drawings. Single Row for one utility service (9 m service road) |
| 234 | Providing concrete cradle bedding in M -15 grade concrete as per Section 2900 and as per section 1700 and 2900 of the specifications (9 m service road) |
| 235 | Providing and applying 2.5 mm including reflectorising glass beds @ 250 gm per Sqm area thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi-automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and as per Section 803 of specifications (9 m service road) |
| 236 | Providing and fixing of Category-A Bi-directional Twin-Moulded Shank Raised Pavement Markers/ Road Stud made of Plastic body moulded from ASA (Acrylic styrene Cryometries) or HIP (High impact polystyrene) or ABS material. Lens shall be of plastic material. The marker shall have compressive strength of 13635 kg tested accordance with ASTM D4280 and shall have Flexural Strength of 909 kgf. Reflective panels shall consist of number of lenses containing Single or dual prismatic cubes capable of providing total internal reflection of light entering the lens face. The Slope or the retro-reflecting surface shall be 35 +/- 5 degree to the base and area of Each retro reflecting surface shall not be less than 13 sqcm. When impacted in accordance with 9.4.1 of ASTM D4280, the face of the lens shall show no more than two radial cracks longer than 6.4 mm (0.25 in.). There shall be no radial cracks extending to the edge of the abrasion resistant area. There shall be no delamination. Height of the marker shall not exceed 20 mm and its width shall not exceed 130 mm. Moulded shank RPM shall have the shank strength of 600 kgf. Head of the stud shall be Smooth and shall not present any sharp edges to traffic. RPM shall be of Category A with optical performance (Coefficient of Luminous Intensity- CIL) shall not be less than that given in Table 800-13 of the specifications for Bi-directional stud. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin-based adhesive. The bidder shall submit a prequalification warranty for Two years. Test certificate from an as per ASTM D 4280, Coefficient of Luminance Intensity-CIL as per table 800-13 of the specifications. Material, Marker Height, Colour, Slope of Reflecting Surface (Lens), Lens Impact strength, Resistance to temperature cycling, and Longitudinal Flexural Strength to be submitted (9 m service road) |
| 237 | Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earthincludingofall lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. All kinds of soil |
| 238 | Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering All work up to plinth level. Cement concrete gradeM-15 (Nominal Mix) with 20 mm maximum size of stone aggregate |
| 239 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Cement concrete grade M-20 (Nominal Mix)with 20mm maximum size of stone aggregate |
| 240 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Foundations, footings, bases of columns, etc. For mass concrete — PCC Below Footing |
| 241 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Foundations, footings, bases of columns, etc. For mass concrete |
| 242 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Foundations, footings, bases of columns, etc. For mass concrete — Footing |
| 243 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 244 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc — Curtain Wall |
| 245 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Suspended floors, roofs, landings, balconies and access platform |
| 246 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plateor plywood shuttering for : — Columns, Pillars, Piers, Abutments, Posts and Struts |
| 247 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands,plain window sills, staircases and spiral staircases upto floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20mm maximum size of stone aggregate |
| 248 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level and up to floor two level excluding cost of centering, shuttering and reinforcement etc. Cement concrete grade M-20 (Nominal Mix) with 20mm maximum size of stone aggregate — Column Above Plinth |
| 249 | Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor two level excluding the cost of centering, shuttering and reinforcement with Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate — Shikhar |
| 250 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal / inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5mvertical lengthof reinforcement in wall columns(over laps shall beprovided as per requirement of IS:13920; IS456&SP: 34) etc. complete. Thermo-Mechanically Treated bars. (Fe 500 D or more) — 140Kg/ Cum of RCC |
| 251 | Stonework plain ashlar masonary in domes in cement mortar 1:3 (1 cement :3 coarse sand) including centring, shuttering and pointingwithwhite cement mortar 1:2(1 white cement :2 Marble dust) with an admixture of pigment matching the stone shade. White sand stone — Shikhar |
| 252 | Brickwork with flyash lime bricks (FALG Bricks) conforming to IS:12894- 2002, class designation 50 (average compressive strength) in super structure above plinth level up to floor 2 level including thecost of scaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 253 | 12 mm cement plaster of mix: 1:6 (1 cement: 6 sand) |
| 254 | 15mm cement plaster on the rough side of single or half brick wall of mix: 1:6 (1 cement: 6 sand) |
| 255 | Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @3.28 ltr/10sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 256 | Providing and fixing chicken mesh as per ISI specificationand in the required width with 50mm long Bombay nails on vertical and horizontal junctions of RCC and brickwall including scaffolding and all lead and lift etc. complete before plastering upt 10 meter height |
| 257 | Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to theunder layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge 20 mm wide and 15 mm deep groove |
| 258 | Marble stone flooring with 16mm to 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge of Laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) jointed with grey cement slurry including rubbing and polishing complete with : Makrana white second quality |
| 259 | Marble work gang saw cut (polished and machine cut)of thickness 16mm for wall lining (veneer work) in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing with white cement mortar 1:2 (1 white cement:2 marble dust) with an admixture of pigment to match the marble shade:(To be secured to the backing by means of cramps, which shall be paid for separately). Makrana Marble Area of slab over 0.50 sqm(b) |
| 260 | Wiring for circuit wiring with PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C.conduit(HMS) of ISI marked suitable size including painting etc.as required as per specification — a) 2x2.5 Sq.mm |
| 261 | Wiring for circuit wiring with PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C.conduit(HMS) of ISI marked suitable size including painting etc.as required as per specification — b) 4x2.5 Sq.mm |
| 262 | WIRING IN CONCEALED RIGID PVC CONDUIT (HEAVY DUTY) SYSTEM WITH MODULER ACCESSORIES — a) Short point |
| 263 | WIRING IN CONCEALED RIGID PVC CONDUIT (HEAVY DUTY) SYSTEM WITH MODULER ACCESSORIES — b) Medium point |
| 264 | WIRING IN CONCEALED RIGID PVC CONDUIT (HEAVY DUTY) SYSTEM WITH MODULER ACCESSORIES — c) Long point |
| 265 | WIRING IN CONCEALED RIGID PVC CONDUIT (HEAVY DUTY) SYSTEM WITH MODULER ACCESSORIES — a) Short point |
| 266 | WIRING IN CONCEALED RIGID PVC CONDUIT (HEAVY DUTY) SYSTEM WITH MODULER ACCESSORIES — b) Medium point |
| 267 | WIRING IN CONCEALED RIGID PVC CONDUIT (HEAVY DUTY) SYSTEM WITH MODULER ACCESSORIES — c) Long point |
| 268 | Power wiring in surface rigid p.v.c.conduit (heavy duty) system with modular accessories — A. Short Point |
| 269 | Power wiring in surface rigid p.v.c.conduit (heavy duty) system with modular accessories — B. Medium Point |
| 270 | Power wiring in surface rigid p.v.c.conduit (heavy duty) system with modular accessories — C. Long Point |
| 271 | Modular switch boxes — 1 Or 2 Module |
| 272 | Modular switch boxes — 4 Module |
| 273 | Modular switch boxes — 6 Module |
| 274 | Modular switch boxes — 8 Module |
| 275 | Modular switch boxes — 12 Module |
| 276 | Circuit wiring in existing conduit / pvc casing capping — 1 X 2.5 sq mm |
| 277 | Circuit wiring in existing conduit / pvc casing capping — 2 X 2.5 sq mm |
| 278 | Circuit wiring in existing conduit / pvc casing capping — 3 X 2.5 sq mm |
| 279 | Circuit wiring in existing conduit / pvc casing capping — 1 X 4.00 sq mm |
| 280 | Circuit wiring in existing conduit / pvc casing capping — 2 X 4.00 sq mm |
| 281 | Circuit wiring in existing conduit / pvc casing capping — 3 X 4.00 sq mm |
| 282 | Sub mains in surface rigid steel conduit in copper conductor — 6.0 sq mm cable in 25 mm conduit |
| 283 | Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415Volts, 50Cycle, 10 kA Value AC supply confirming to IS:8828:1996, IEC:60898 :2002 but without enclosures — 6 Amp to 32 Amp Rating |
| 284 | Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415Volts, 50Cycle, 10 kA Value AC supply confirming to IS:8828:1996, IEC:60898 :2002 but without enclosures — 6 Amp to 32 Amp Rating |
| 285 | Supply of approved make powder coated sheet steel encloser SPN MCBDB inclusive of Busbar, Neutralbar, Earthbar & two earth terminal setc.complete as per IS:13032 (exclusive of MCB & isolator) — 12 way double door |
| 286 | Supplying and installing of RCBOs (Residual current circuit breaker with over load and short circuit protection) ISI marked complete as per I.S. standard confirming to IEC:61009-2-1&IS:12640- 2:2001, 240/415V 50 Hz with 10kA short circuit with stand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification — 2 pole 32 Amps, 30 mA sensitivity |
| 287 | Fixing of MCB /MCCB/ Isolator — Fixing of MCB / Isolator SP/DP in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (Labour only ) |
| 288 | Labour charges for fixing sheet steel enclosure, MCBDB surface mounting type, as per accepted practice on 25x5mm flat iron clamps duly embedded in wall,cable connection etc. complete — 8.5 (1) to 8.5 (4) |
| 289 | Labour charges for fixing sheet steel enclosure, MCBDB surface mounting type, as per accepted practice on 25x5mm flat iron clamps duly embedded in wall,cable connection etc. complete — 8.5 (5) & 8.5 to 8.6 (2) |
| 290 | Labour charges for fixing sheet steel enclosure, MCBDB surface mounting type, as per accepted practice on 25x5mm flat iron clamps duly embedded in wall,cable connection etc. complete — 8.6 (3), 8.6(4) & 8.7 (1) |
| 291 | Labour charges for fixing sheet steel enclosures, MCBDB flush mounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc. complete — 8.5(1) to 8.5(5), 8.6(1) to 8.6 (5) & 8.7(1 |
| 292 | Suppling and fixing of approved make step type Modular electronic, Fan regulator single / double module including connection etc. as required on existing board — 450 Watt |
| 293 | Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C.230-250volts including connections with all necessary material completed as required confirming to IS :374/1979 with upto date ammendments — Ceiling Fan (Energy Saver 50 W)-1200 mm Sweep |
| 294 | Supplying, erecting and testing of approved make Exhaust Fan heavy duty with mounting frame, blades AC230-250 complete connection and including, frame bolt/ Anchor hole fastners etc. complete finished and as required — 380mm sweep 900 RPM |
| 295 | Supplying, fixing and testing of approved make fluorescent tube fitting 36/40 watt,rust resistant, stove enamelled paint, boxtype channel with cover, complete with electronic ballast (HF complete duly wired (without tuberod) as per specification & fixing as below: — I)Fixing on wall / Ceiling on wooden round block with 'J' hook / Anchorhole fastners / hollow bow with rod fixed in Ceiling and other necessary materials including connections etc. and as required |
| 296 | BULK HEAD — Supplying, fixing and testing of approved make bulk head luminaire consisting of pressure die aluminium housing lamp holder, prismatic glass cover, rubber gasket and wire guard, delux type, including fixing on wall as required, with necessary material complete Fitting(sutiable for GLS w/o lamp upto 11 watt Retorted CFL |
| 297 | Supplying, fixing and testing of approved make high pressure M.V. fitting, consisting of cast aluminium cotrol gear housing, highly polished reflector, highly transparent acrylic hinged cover, complete with taped polyster choke, capacitor, connectoretc. suaitable for end mounting duly wired (without lamp) including fixing with 25/30 mm dia G.I. pipe medium class of required length upto 2 Meter for mounting on wall / existing pole /on existing 'D' bracket, including bending the pipe to required shape and connections including all materials as required — 125 Watt |
| 298 | Supplying, fixing & testing of approved make of T-5 lamp channel luminaire with plastic extruded housing within- built electronic control gear with decorative end caps with necessary materials connection etc.complete as required (with lamp) — T - 5 Lamp 1 X 28 watt |
| 299 | Supply of XLPE Insulated power cable (conforming IS-7098 ) 1100 Volt grade / Heavy duty power cable conforming to IS 1554-1100 Volts grade, 2core / 3½core / 4core ISI MARKED with Alu. Stranded /solid conductor — 10 Sq.mm.(XLPE |
| 300 | Providing and erecting expoxy resin end termination / joint for low tension P.V.C. / XPLE insulated cable of 1100Volt grade complete with cable jointing compound, Harner, Plastic mould adhesive cum solvent expoxy putty, spacer, tapes etc. as per I.S. specification 8438.1977 for cable duty erected on existing pole / support / switch gears and connection to supply for all core cable as under — a. 10-50 sq.mm. 2 / 3 / 3/½ core |
| 301 | BRASS COMPRESSION GLAND — Gland Size 22mm suitable for cable 2, 3, 3½, 4 x 10Sq.mm or 2x 16 Sq.mm |
| 302 | Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu. / Copper solid / stranded conductor evently cramped with high/pressure tool and connected to switch gear / Bus / M.C.C.B. / M.C.B. etc. as required complete. For Conductor Size — 6 mm to 16 Sq.mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysDec 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender