Tender For Reconstruction Of Munch And Baradari And Gate At Salori Durga Puja
Tender Value
21.06 Lakhs
Estimated cost
Bid Submission
01 Dec 2026
2 days left
EMD
43000
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Prayagraj → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Reconstruction Of Munch And Baradari And Gate At Salori Durga Puja
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. As per Code No. 2.8.1 |
| 2 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.as per DSR 2.27 |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 Cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) As per DSR Code No. 4.1.11 |
| 4 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). As Code No-5.1.2 |
| 5 | Centering and shuttering including stutting, propping etc. and removal of form for Foundations, footings, bases of columns etc. for mass concrete. As per DSR Code No- 5.9.1 |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Above Plinth Level. As per Code No-5.2.2 |
| 7 | Centering and shuttering including stutting, propping etc. and removal of form for Columns, pillars, piers, abutments, posts and struts. As per DSR Code No- 5.9.6 |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand). As per DSR Code No- 6.1.2 |
| 9 | Centering and shuttering including stutting, propping etc. and removal of form for Lentels beams, plinth beams, girders, bressumers and cantilevers, As per DSR Code No- 5.9.5 |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). Above Plinth Level. As per Code No-5.3 |
| 11 | Steel reinforcement for R.C.C. work ready to use \\"cut and bend\\" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per Code No.- 5.22 .6 |
| 12 | Centering and shuttering including stutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access plateform. As per DSR Code No- 5.9.3 |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of Class designation 7.5 in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ). As per Code No 6.4.2 |
| 14 | 12mm cement plaster in single coat on fair side of single or half brick wall for interior plastering upto floor two level including brick wall for interior plastering upto floor two level including internal rounded angles chafers,and or rounded angles not excedding 80mm in grith and finished even and smooth No.extra for mixing and additive.1-1Cement:6 Sand as per DSR 13.1.2 |
| 15 | E/w in filling or in embankment in foundation or plinth in ordinary soil including lift up to 1.5m and lead up to 30m and including filling watering ramming of excavated earth as per dsr 2.25a |
| 16 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plasterd wall surface even and smooth surface. As per Code No-13.80 |
| 17 | Finishing with deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers specifications two or more coats applied on wall @ 1.25ltr/10sqm over and i/c one coat of special primer applied @ .90litre/10sqm as per DSR 13.48.1 |
| 18 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iro |
| 19 | Wiring point for Light ,fan ,exhaust fan etc with 1.5sq. mm. FR PVC insulated multistrand single core copper cable in PVC conduit with 1.5 sq.mm. FR PVC-insulated multistrand Copper conductor cable as earth wire drawn in side the conduit. Add for light/f |
| 20 | Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 1.5sqmm. FRLS |
| 21 | Supply fixing & concealing of PVC conduit in the wall including cutting of brick laying of conduit & fixing it with MS hooks & then plastering.with cement, sand,mortar finished to the level,with matching colour wash including cost of proper thrading of c |
| 22 | Supply & wiring of submains with 2 nos.2.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge PVC conduit partly concealed in wall and partly laid in slabalong with the reinforcement before concreting, with 1 no. 1.5 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. |
| 23 | Supply and fixing of 63 amp DP 30 mA ELCB/ RCCB of Din Rail mounting in DB complete in all respect with connections as required. |
| 24 | Supply & fixing and making connection of 63 amp. 4P 30 mA ELCB/ RCCB of Din Rail mounting in complete in all respect as per direction and satisfaction to the Engineer in Charge. |
| 25 | Supply & fixing of Batton/Angle holder including making connection etc. as required. |
| 26 | Supply and fixing of 240 volts C Curve 6-32 amp SP miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A |
| 27 | LED street light fixture powder coated pressure diae i/c all complete as per DSR 1.14.8 30watt |
| 28 | Suppply and fixing of sign board I/C all. |
| 29 | As per Order of Joint Secretary G.O. No. G-1877 Dated 21-02-2025 and Director cum-chief Engineer U.P. RED, Lucknow Latter No 801 Dated 03-03-2025 Deduction 5% for Comptetive Price Effciency Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysDec 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender