Public Administrative Department Local Bodies Closing in 9 days TDR #58689792

Tender For INSTALLATION Of Drinking Water With Solar System At Near House Of Upen Roy Booth No 68 Under Domohani I Gram Panchayet Within Maynaguri Block.Activity Id-132161722

Issued by Local Bodies · Jalpaiguri, West Bengal
Tender Value
3.99 Lakhs
Estimated cost
Bid Submission
08 Dec 2026
9 days left
EMD
7996
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for INSTALLATION Of Drinking Water With Solar System At Near House Of Upen Roy Booth No 68 Under Domohani I Gram Panchayet Within Maynaguri Block.Activity Id-132161722

BOQ

Name of Work:- INSTALATION OF DRINKING WATER WITH SOLAR SYSTEM AT NEAR HOUSE OF UPEN ROY BOOTH NO 68 UNDER DOMOHANI I GRAM PANCHAYET WITHIN MAYNAGURI BLOCK.ACTIVITY ID-132161722
Sl. No. Item Description
1Labour for boring tube well of required dia by water jet system through any type of soil strata including hire and labour charges for boring pipes,scaffolding,tools and plants as necessary and taking out them and lowering pipes,stariners,blind pipe etc,and fitting and fixing the same complete including bucket washing and other incidental works in the connection.The tube well should have a minimum 50 mm gapbin between the outside of the tubewell pipe and the bore.ii) 150 mm dia boring etc top enlargementPART-A
2Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality
3Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality
4Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).100 mm dia
5Providing and fixing gun metal non- return valve of approved quality 50 mm nominal bore. Horizontal
6Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.100 mm clamp
7Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.100 mm nominal size dia
8Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External workUpto Storage Tank32 mm nominal dia Pipes
9Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
12Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
13Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
14Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
15Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
16Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
1715 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
18Neat cement punning.
19Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External workFrom Storage Tank to Tap25 mm nominal dia Pipes
20Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(b) 1000 litre capacity
2115 mm PTMT bib cock
22Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
23Providing and erecting direction and place identification retro reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75x 75x6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing (Reference to MORT&H's specification 801).
24Supplying fitting and fixing 300 mm M.S. housing clamp of approved quality.PART-B
25Supplying fitting and fixing 300 mm M.S. housing clamp of approved quality.
26Solar Module: Supply, transport, installątion and commissioning of ISI marked Solar Modules as per following specification: 1. Cell: Indigenous mono crystalline silicon SPV cells 2. Solar Module: Monocrystalline cell with PERC technology / module with bifacial cell. 3. Standards: 1st marked as per IS 14286 and having certification of IEC 61853(1), 61730(1&2), 61710 4.ModuIes must qualify to lS 170210 (Part 1) 5.Min. Efficiency: 19.5%. 6. Fill factor: More than 75% . 7. Module wattage mismatch in the SPV array: within -t3% 8. Wattage output warranty:ShouId not be less than 90% at the end of 10 years and 80'X at the end of 25 years. 9.The power output of individual PV modules used in the PV array, under STC: minimum 300 Wp. Necessary test certificates also to be supplied. For detail information please see CI. no. 2.1 of technical specificationb) For 2 HP Off-grid Solar Water Pumping System with Monocrystalline/ Monocrystalline PERC / Bifacial SPV modules - 2150- 2400 Wp.
27Module Mounting Structure ( For 1 HP, 2HP, 3HP, SHP and 10 HP Solar Water Pumping System): Supply, transportation & installation of G.I manual tracking / Fixed structure made of MS hollow sections, pipes, plates, angles etc as per IS:4923, IS:1161/1239, IS:1079/2062, to hold min 300 Wp SPV Module as per drawing and technical specification. The steel structure is to be protected with minimum 80 micron gaIvanisation(hot dip) and provided with fixed arrangement or dual axis manual tracking arrangement for three times in a day and seasonal tilting to face the sun optimally.
28Power condltlonlng unit with enclosure :Supply , transport , installation and commissioning of Solar Power conditioning Unit consisting of following components and features:1) Variable frequency Drive with Inbuilt MPPT, voltage range suitable for operating pump-motor set of 1HP to 20 HP, detail mentioned In cl.6.12) Power Input : DC source for 1HP, 2HP and 3HP.3) Power input : AC / DC source or hybrid for SHP and above.4) Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.SHP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-25) Incomer: AC MCB 4 pole 16 amp for 5.0 HP, 25 amp for 7.5HP and 10 HP, 40 amp for IS to 20 HP ar per IS/IEC 60947-16) Type II DC SPD of 40 KA.7) Type II AC SPD of 40 KA for AC/ DC or Hybrid Input.8) Dual Input (solar/Grid) 25 amp changeover switch for SHP and 7.5 HP, 40 amp for 10 HP, 63 amp for 1S to 20 HP9) Reverse protection diode 1600 VDC with heat sink.10) Data Logger.11) Remote menltoring system.12) Should have built -In EMC filters .13) IP 65 elands for cable In and out.14) Min. IP 54 enclosure.For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standards to be qualified, etc. please refer to CI. 6.1 of technical qualification.Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(f) to 3(I). a) For 1 HP/2 HP/3HP per structure
29Cable and Accessories :Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc.i). 4.0 Sq mm single core multi studs - 5m (for 1HP/2HP/3HP) & 20m (for 5/7.5/10/15/17.5/20 HP)ii). Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc
30Earthing: Earthing with S0 mm dia GI pipe 3.64 mm thlck x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dla x 80 mm long GI bolts, double nuts, double washers incl. S & F 1s mm dia GI pipe protection (1 Mts. long) to be filled with bltumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By lSl-Medium GI pipe Includlng excavation of soil for Installation of Earth Each Set Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments Incl. drilling holes, with bolts, nuts, washers etc.
31Supplying, fitting and fixing of Sand Filter - Manual as per IS:14616 Sand Filter 10CuM/hr-M Single
32b) Lightning protection (Pole mounted): Lightning protection with 3\\" X 1.5\\" G.I pipe of 6m + 1 m height with base flange In proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dla 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long Each galvanized bolt, double nuts, double washers Including socketing at both ends of stranded GI (Hot Dip) wire by crimplng sockets/ thlmbles and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. including connection to earth electrodes with 25 X 6mm G.I strip.
33Supply and installation of 3 phase AC electromotor pump-motor set with speed of 3000 r.p.m(synchronous speed) suitable for Solar applications and shall have 60 months guarantee for the following conditions Including loading, unloading, transportation etc .:- (Refer technical specification for more detail) a) 1 HP 3 phase AC surface mounted Monoblock Pump-motor set as per IS 9079 with with discharge of 4.0 -5.0 Lps at 8 mts. total head with , required quantity of flexible delivery pipe( 10m), clamps , cable and all other accessories to complete Set connection of suction and delivery side.
34Testing and commissioning of scheme after completion of all work
35Cleaning and washing of modules once In month with clear water to remove deposited dust and dirt on the module surface and keep the modules clean throughout the year. The activity to be performed for eight months in a year excluding four monsoon months. A log book should be maintained at the site for the said purpose.
36Comprehensive maintenance charges for 5 years (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme In operation without lapse of time) a) For 2 HP both for Submersible & Surface pump
37PART-Acorrection factor
38PART-AApplying Cost Index for Jalpaiguri, 34(1)/SDG(Kol)/Cost Index/2025/1316 [Cost Index= 119 as on 01.10.2025], TOTAL AMOUNT
39Part-A
40Part-B
41Part-B 18% GST
42Part-B 1% CESS Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58689792
AUTHORITY Local Bodies
TENDER VALUE 3.99 Lakhs
LAST DATE 08-12-2026
Authority
Authority Name Zilla Parishad
Work Description Tender for INSTALLATION Of Drinking Water With Solar System At Near House Of Upen Roy Booth No 68 Under Domohani I Gram Panchayet Within Maynaguri Block.Activity Id-132161722
Basic Detail
Tender No 04/Dom-I GP/2026-27 DATE-23-11-2026
Bidding Type Tender
Location
City Jalpaiguri
State West Bengal
Key Dates
Publish Date 24 Nov 2026
Submission Date 08 Dec 2026
Open Date 11 Dec 2026
Finance
Tender Value 3.99 Lakhs
Tender Fee 500
EMD 7996
Exemption Not Available
Document List
125533dd-8732-478c-8ac1-ea8231bb2d60.html
BOQ_5221036.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Dec 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

125533dd-8732-478c-8ac1-ea8231bb2d60.html

xls

BOQ_5221036.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender