Tender For Providing & Installation Of Lift And Allied Civil, Electrical Works For Muriganga Inspection Bunglow, Lot-8, Under South 24 Parganas Mechanical Division, Phe Dte.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Dec 2026
5 days left
EMD
1.43 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing & Installation Of Lift And Allied Civil, Electrical Works For Muriganga Inspection Bunglow, Lot-8, Under South 24 Parganas Mechanical Division, Phe Dte.
BOQ
| Sl. No. | Item Description |
| 1 | Part- A: Lift |
| 2 | Supply,delivery, and storage at site of 5 passenger lift (408 Kg), well size 1650(W) x1550(D) approx with the following specification: CAPACITY (kgs) : 408 kg, persons SPEED (mps) : 1 RISE (m) : 7.5 m STOPS : 3 Stops With (all opening on the same side) CONTROLLER TYPE : ACD5 DRIVE : VF Regenerative (Closed Loop) POWER SUPPLY : Volts (3 Phase AC) OPERATION : Full collective operation CAR GROUP : One car (simplex) TRACTION MEDIA : Flat Coated Steel Belt CAR FINISH : Stainless steel #4 finish-SS-304CAR DOOR FINISH :Full Glass With stainless steel #4 finish Frame LANDING DOORS FINISH :Full Glass With Stainless steel #4 finish Frame |
| 3 | STANDARD FEATURES :Anti-nuisance Car Call ProtectionIndependent Service (for Duplex only)Overload DeviceNudgingEmergency Firemen’s ServiceEmergency Car Light UnitInfrared Curtain Door ProtectionDoor Time ProtectionEmergency Alarm ButtonExtra Door Time of Lobby & ParkingDoor Open/Close ButtonManual Rescue OperationBelt Inspection DriveAuto Fan Cut Off Automatic Rescue Operation ADDITIONAL FEATURES:Speech Synthesis Module ,Pit water sensor, Provision for CCTV ,Intercom |
| 4 | Installation and commissioning of the above Lift after completion of the required civil works and testing complete as per direction of EIC |
| 5 | Charges for obtaining lift license along with preparation of statutory drawing & document from competent authority inclusive of all incidental charges. |
| 6 | Total for Part-A |
| 7 | Part- B: Electrical work |
| 8 | Supply, delivery and storage of the following materials at site |
| 9 | 4 core 10 sq mm Cu armoured cable 1.1KV grade XLPE insulated armoured aluminium conductor cable conform to IS 7098/ Part I. |
| 10 | 63A TPN 415V Main switch in sheet steel enclosure with neutral link rewireable porcelian fuse unit for lift panel power supply. |
| 11 | 6W LED low hight ceiling mounted down light, PDC housing including all accessories as specified and directed by the deptt. |
| 12 | 15W LED low hight ceiling mounted down light, PDC housing including all accessories as specified and directed by the deptt. |
| 13 | Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon 10 W bulk head Back-lit LED luminaire comprising of high brightness LED and directed by the deptt |
| 14 | Solar pillar Light with built in solar panel, LED light and lithium battery with charge controller IP 65 protection including all accessories as specified and directed by the deptt. |
| 15 | 300 mm sweep celing suspended cabin fan complete with all accessories like down rod, canopy etc. with making necessary connection cable, similar to model: AURA of Crompton make or approved by the deptt |
| 16 | Supply, delivery at site 240 V, 6 A Modular type switch on existing GI Modular type switch board having top cover plate and making necessary connections as required. |
| 17 | 240 V, 16 A Modular type switch on GI Modular type switch board having top cover plate and making necessary connections as required. |
| 18 | 240 V, 6A, 3 pin Modular type plug socket without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 19 | 240 V, 16 A, 3 pin Modular type plug socket without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 20 | Installation and commissioning of the above equipment, laying of cable, fixing of the fan & light fittings, etc. including supply of necessary consumables like fastner, fish nut bolt, loop wire, etc. and electrical connection by expert electrician complete the job as per direction of EIC. |
| 21 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC |
| 22 | Average run 6 mtr |
| 23 | Total for Part-B |
| 24 | Part- C: Earthing & Lightning Protection |
| 25 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as below: |
| 26 | by ISI-Medium GI pipe |
| 27 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required |
| 28 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required |
| 29 | Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) |
| 30 | making suitable scaffolding arrangement and Installation of earthing and lightning protection system with supply of all erection material such as clamp, connector, nut, bolts, fastner etc. as per direction of EIC. |
| 31 | Providing and fixing of 3 phase surge protection device in panel, High Discharge Current : Imax 50 kA (L – N)70 kA (N – E), Compact Size : Integrated Type-1 & Type-2 protection in small module width. Ideal in all reduced-size plants. Better Protection : Voltage protection level 1.5 kV. |
| 32 | Total for Part-C |
| 33 | Part- D: Civil work |
| 34 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreding or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. |
| 35 | Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. |
| 36 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 37 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur variety |
| 38 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 25 Grade |
| 39 | Reinforcement for reinforced concrete work in all sorts of structures including distributions bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction (a) For works in foundation, basement and up to roof of ground floor/up to 4 m |
| 40 | Hire and lab labour charges for shuttering with centering and necessary staging up to 4 m using approved stout props and thick bard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after complete of works (up to roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-in-Charge. |
| 41 | Brick work with 1st class bricks in cement mortar (1:6) In superstructure, ground floor |
| 42 | Plaster (to wall, floor, ceiling etc.) with sand and cement motor including rounding off or chamfering corners as directed and taking out joints including threading, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding Cost of chipping over concrete surface] (i) With 1:6 Cement mortar (a) 25 mm thick plaster. |
| 43 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary |
| 44 | Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. Area of each Granite slab 0.6 to 1.0 Square meter |
| 45 | Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification anddirection of Engineer-in-charge. 3mm thick |
| 46 | Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. |
| 47 | Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminiumfixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge. |
| 48 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 5mm thick coloured / tinted / smoke glass |
| 49 | Structural Glazing made of extruded and annodized alloy aluminium sections, fabrications including cutting to proper shape and size, drilling including cost of brackets, fastener bolt, mullion bolt, nuts & washers, maskin tape, double side adhesieve crosslink foam (used for guard of glazed silicon on sub-frame), tissue paper foam (used as filler between sub-frame and under backing of weather silicon), screws and other necessary hardwares, fixing of glass as per drawing, specification and direction of Engineer-in-Charge. (The rate includes hire charges of all tools and plants, including all incidental charges, adhesieve, joiners such as screw,cleate angle,etc. but excluded the cost of extruded aluminium sections, glass, glazed silicon, weather silicon etc.) |
| 50 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools andplants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. |
| 51 | Supplying profiles of required section made of Aluminium Alloy Extrusion conforming to IS: 732-1983 and IS: 1285-1975; Anodised with required film thickness and specified colour/natural matt finished conforming to IS: 1868-1983 for fabrication of Structural Glazing, Curtain Wall formed of basic sections of any ISI embossed/certified make and brand as per direction of Engineer-in-charge. ( Payment will be made on finished length of the work).15 micron colour anodising Structural glazing /Curtain Wall |
| 52 | Mulion & Transom (Weight @1.819 Kg per Meter) |
| 53 | Sub frame for fixing Glass (Weight @0.31 Kg per Meter) |
| 54 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987, coloured, toughened glass conforming to IS: 2553-1992 (part-II), 6 mm thick |
| 55 | Supplying Glazing Silicon of approved make and brand for fixing of Glass on Sub-frame as per direction of Engineer-in-charge for Structural Glazing/Curtain wall etc. |
| 56 | Supplying Weather Silicone sealant of approved make and brand for fixing of grove line between the Glasses as per direction of Engineer-incharge.for Structural Glazing/Curtain wall. |
| 57 | Dismantling R.C. floor, roof, beams etc. includingcutting rods and removing rubbish as directedwithin a lead of 75 m. including stacking of steelbars. In ground floor including roof |
| 58 | Labour charges for lowering and stacking after dismantling in parts R.S. joists, channels, angles, tees, plates etc.complete as directed. |
| 59 | Providing and fixing double scaffolding system on the exterior side, up to roof made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 60 | Add GST @ 18% |
| 61 | Add CESS @ 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysDec 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender