Drinking Water Supply and Sanitation Government Departments Closing in 5 days TDR #58689546

Tender For Providing & Installation Of Lift And Allied Civil, Electrical Works For Muriganga Inspection Bunglow, Lot-8, Under South 24 Parganas Mechanical Division, Phe Dte.

Issued by Government Departments · Kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Dec 2026
5 days left
EMD
1.43 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing & Installation Of Lift And Allied Civil, Electrical Works For Muriganga Inspection Bunglow, Lot-8, Under South 24 Parganas Mechanical Division, Phe Dte.

BOQ

Name of Work:- Providing & installation of lift and allied civil, electrical works for Muriganga Inspection Bunglow, Lot-8, under South 24 parganas Mechanical Division, PHE Dte.
Sl. No. Item Description
1Part- A: Lift
2Supply,delivery, and storage at site of 5 passenger lift (408 Kg), well size 1650(W) x1550(D) approx with the following specification: CAPACITY (kgs) : 408 kg, persons SPEED (mps) : 1 RISE (m) : 7.5 m STOPS : 3 Stops With (all opening on the same side) CONTROLLER TYPE : ACD5 DRIVE : VF Regenerative (Closed Loop) POWER SUPPLY : Volts (3 Phase AC) OPERATION : Full collective operation CAR GROUP : One car (simplex) TRACTION MEDIA : Flat Coated Steel Belt CAR FINISH : Stainless steel #4 finish-SS-304CAR DOOR FINISH :Full Glass With stainless steel #4 finish Frame LANDING DOORS FINISH :Full Glass With Stainless steel #4 finish Frame
3STANDARD FEATURES :Anti-nuisance Car Call ProtectionIndependent Service (for Duplex only)Overload DeviceNudgingEmergency Firemen’s ServiceEmergency Car Light UnitInfrared Curtain Door ProtectionDoor Time ProtectionEmergency Alarm ButtonExtra Door Time of Lobby & ParkingDoor Open/Close ButtonManual Rescue OperationBelt Inspection DriveAuto Fan Cut Off Automatic Rescue Operation ADDITIONAL FEATURES:Speech Synthesis Module ,Pit water sensor, Provision for CCTV ,Intercom
4Installation and commissioning of the above Lift after completion of the required civil works and testing complete as per direction of EIC
5Charges for obtaining lift license along with preparation of statutory drawing & document from competent authority inclusive of all incidental charges.
6Total for Part-A
7Part- B: Electrical work
8Supply, delivery and storage of the following materials at site
94 core 10 sq mm Cu armoured cable 1.1KV grade XLPE insulated armoured aluminium conductor cable conform to IS 7098/ Part I.
1063A TPN 415V Main switch in sheet steel enclosure with neutral link rewireable porcelian fuse unit for lift panel power supply.
116W LED low hight ceiling mounted down light, PDC housing including all accessories as specified and directed by the deptt.
1215W LED low hight ceiling mounted down light, PDC housing including all accessories as specified and directed by the deptt.
13Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon 10 W bulk head Back-lit LED luminaire comprising of high brightness LED and directed by the deptt
14Solar pillar Light with built in solar panel, LED light and lithium battery with charge controller IP 65 protection including all accessories as specified and directed by the deptt.
15300 mm sweep celing suspended cabin fan complete with all accessories like down rod, canopy etc. with making necessary connection cable, similar to model: AURA of Crompton make or approved by the deptt
16Supply, delivery at site 240 V, 6 A Modular type switch on existing GI Modular type switch board having top cover plate and making necessary connections as required.
17240 V, 16 A Modular type switch on GI Modular type switch board having top cover plate and making necessary connections as required.
18240 V, 6A, 3 pin Modular type plug socket without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
19240 V, 16 A, 3 pin Modular type plug socket without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
20Installation and commissioning of the above equipment, laying of cable, fixing of the fan & light fittings, etc. including supply of necessary consumables like fastner, fish nut bolt, loop wire, etc. and electrical connection by expert electrician complete the job as per direction of EIC.
21Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
22Average run 6 mtr
23Total for Part-B
24Part- C: Earthing & Lightning Protection
25Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as below:
26by ISI-Medium GI pipe
27Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
28Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
29Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
30making suitable scaffolding arrangement and Installation of earthing and lightning protection system with supply of all erection material such as clamp, connector, nut, bolts, fastner etc. as per direction of EIC.
31Providing and fixing of 3 phase surge protection device in panel, High Discharge Current : Imax 50 kA (L – N)70 kA (N – E), Compact Size : Integrated Type-1 & Type-2 protection in small module width. Ideal in all reduced-size plants. Better Protection : Voltage protection level 1.5 kV.
32Total for Part-C
33Part- D: Civil work
34Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreding or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete.
35Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand.
36Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
37Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur variety
38Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 25 Grade
39Reinforcement for reinforced concrete work in all sorts of structures including distributions bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction (a) For works in foundation, basement and up to roof of ground floor/up to 4 m
40Hire and lab labour charges for shuttering with centering and necessary staging up to 4 m using approved stout props and thick bard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after complete of works (up to roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-in-Charge.
41Brick work with 1st class bricks in cement mortar (1:6) In superstructure, ground floor
42Plaster (to wall, floor, ceiling etc.) with sand and cement motor including rounding off or chamfering corners as directed and taking out joints including threading, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding Cost of chipping over concrete surface] (i) With 1:6 Cement mortar (a) 25 mm thick plaster.
43Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary
44Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. Area of each Granite slab 0.6 to 1.0 Square meter
45Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification anddirection of Engineer-in-charge. 3mm thick
46Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge.
47Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminiumfixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge.
48Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 5mm thick coloured / tinted / smoke glass
49Structural Glazing made of extruded and annodized alloy aluminium sections, fabrications including cutting to proper shape and size, drilling including cost of brackets, fastener bolt, mullion bolt, nuts & washers, maskin tape, double side adhesieve crosslink foam (used for guard of glazed silicon on sub-frame), tissue paper foam (used as filler between sub-frame and under backing of weather silicon), screws and other necessary hardwares, fixing of glass as per drawing, specification and direction of Engineer-in-Charge. (The rate includes hire charges of all tools and plants, including all incidental charges, adhesieve, joiners such as screw,cleate angle,etc. but excluded the cost of extruded aluminium sections, glass, glazed silicon, weather silicon etc.)
50M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools andplants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.
51Supplying profiles of required section made of Aluminium Alloy Extrusion conforming to IS: 732-1983 and IS: 1285-1975; Anodised with required film thickness and specified colour/natural matt finished conforming to IS: 1868-1983 for fabrication of Structural Glazing, Curtain Wall formed of basic sections of any ISI embossed/certified make and brand as per direction of Engineer-in-charge. ( Payment will be made on finished length of the work).15 micron colour anodising Structural glazing /Curtain Wall
52Mulion & Transom (Weight @1.819 Kg per Meter)
53Sub frame for fixing Glass (Weight @0.31 Kg per Meter)
54Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987, coloured, toughened glass conforming to IS: 2553-1992 (part-II), 6 mm thick
55Supplying Glazing Silicon of approved make and brand for fixing of Glass on Sub-frame as per direction of Engineer-in-charge for Structural Glazing/Curtain wall etc.
56Supplying Weather Silicone sealant of approved make and brand for fixing of grove line between the Glasses as per direction of Engineer-incharge.for Structural Glazing/Curtain wall.
57Dismantling R.C. floor, roof, beams etc. includingcutting rods and removing rubbish as directedwithin a lead of 75 m. including stacking of steelbars. In ground floor including roof
58Labour charges for lowering and stacking after dismantling in parts R.S. joists, channels, angles, tees, plates etc.complete as directed.
59Providing and fixing double scaffolding system on the exterior side, up to roof made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
60Add GST @ 18%
61Add CESS @ 1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58689546
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 03-12-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Providing & Installation Of Lift And Allied Civil, Electrical Works For Muriganga Inspection Bunglow, Lot-8, Under South 24 Parganas Mechanical Division, Phe Dte.
Basic Detail
Tender No WBPHE/EE/SMD/NIeT-32 of 2026-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 23 Nov 2026
Submission Date 03 Dec 2026
Open Date 05 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1.43 Lakhs
Exemption Not Available
Document List
394efc4d-f48c-40c7-9017-69fb44c01dd2.html
BOQ_5220908.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Dec 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

394efc4d-f48c-40c7-9017-69fb44c01dd2.html

xls

BOQ_5220908.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender