Tender For Special Repair To Internal Electrification Of Certain Married Accommodation At Afs Begumpet Under Ge (Af) Hakimpet
Tender Value
67.50 Lakhs
Estimated cost
Bid Submission
21 Dec 2026
28 days left
EMD
1.26 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Internal Electrification Of Certain Married Accommodation At Afs Begumpet Under Ge (Af) Hakimpet
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,(fittings such as switches, ceiling roses,pendants, regulators sockets etc. to be measuredseparately), removing materials to store for keeping in safe custody for reuse at site and making good to disturbed surfaces of walls, floors and roofs by providing white cement/putty match to as existing surface etc. complete all as specified and as directed. |
| 2 | M & L for point wiring with 1.5 sqmm FR grade PVC insulated and unsheathed stranded copper conductor cable,1100 volts grade as per IS-694 drawn through and including PVC conduit pipe surface/concealed complete with all fittings and acessories including PVC Board/Metal sunken box including white modular cover plates for mounting modular switches, sockets, regulators, etc and 1.5 sq mm stranded copper conductor cable FR grade PVC insulated and unsheathed for earth continuity all as specified and directed for One light Point controlled by one one way switch. complete all as specified and as directed. |
| 3 | All as per Ser item No 2 above but for One Ceiling /Exhaust Fan Point controlled by one one way switch. complete all as specified and as directed. |
| 4 | All as per Ser item No 2 above but for 5 amps socket point on independent board. complete all as specified and as directed. |
| 5 | All as per Ser item No 2 above but for 5 amps socket point on same board controlled by another switch. complete all as specified and as directed. |
| 6 | All as per Ser item No 2 above but for One bell point controlled by one bell push. complete all as specified and as directed. |
| 7 | All as per Ser item No 2 above but with 2.5 sqmm cable for 15 amps socket outlet on independent board with 2.5 Sqmm earth continuty wire complete all as specified and as directed. |
| 8 | All as per Ser item No 2 above but with 4 sqmm cable for 20/25 amps Power Unit on independent board with 4 Sqmm earth continuty wire complete all as specified and as directed.( For Geyser) |
| 9 | All as per Ser item No 2 above but One light point contro lled by two 2- w a y switches, with cables 1.5 sq. mm size complete all as specified and as directed. |
| 10 | Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body. complete all as specified and as directed. |
| 11 | Supply and fix switch modular type, 6 Amps 240 volts single pole one way. complete all as specified and as directed. |
| 12 | Supply and fix socket outlet, 5 pin 6 Amps, Modular type. complete all as specified and as directed. |
| 13 | Supply and fix socket outlet 6/16 Amps, 6 in 1, Modular type. complete all as specified and as directed. |
| 14 | Supply and fix switch modular type,15/16 Amps 240 volts single pole one way. complete all as specified and as directed. |
| 15 | Supply and fix switch Belll Push modular type single pole.complete all as specified and as directed. |
| 16 | Supply and fix modular switch 10 Amps 240 volts single pole two way. complete all as specified and as directed. |
| 17 | Supply and Fixing Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and as directed. |
| 18 | Supply and fix stepped type fan regulator electronic modular type, 2 module, 240 Volt. complete all as specified and as directed. |
| 19 | Labour for Taking down and refixing fan, sealing cable end, dismantling blades and removing fan, cleaning and change capacitor and refixing the same on its original position complete all as specified and as directed. |
| 20 | Supply and fixing 1200mm BLDC 5star rated ceiling fan with regulator enable motor with power input of 28Watt with 10% tolerance, motor insulation B, 230V , 50Hz, single phase A.C speed 350, Air delivery 215CMM with complete set of 3nos blades, down rod , 2 Nos canopies, shackel kit and all remaining accessories including nut bolts, washers ' including connecting up of cable from ceiling rose or connector to fan and taking out existing fan complete all as specified and as directed.Note: - Old Unserviceable fans shall be deposited to MES store. |
| 21 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and as directed. |
| 22 | Supply and fixing complete to walls and ceilings Pipe galvanised steel tubing medium Grade screwed socket jointing including all Fittings such as bend, elbows, tees, short piece jointer,connector,back nut, cap etc which ever required for connection from existing water pipe line of size 15 mm dia complete all as specified and as directed. |
| 23 | S&F Stop valves 15mm dia, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and as directed. |
| 24 | Supply and fix, fancy type, 15mm bore chromium plated bib taps, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for bass ferrule, fancy type complete all as specified and as directed. |
| 25 | Supply and fix 20 watt lumen not less than 120/watt, intregated LED tube light fitting 4 ft , suitable for single phase 230 Volts, 50 Hz AC supply and mounted on wall or ceiling, complete with all accessories internally prewired and including electrically connection with copper conductor cable of size 0.5 Sqmm (nominal area) complete all as specified and as directed. |
| 26 | Supply and fix 10 watt, lumen not less than 110/watt, intregated LED tube light fitting 2 ft , suitable for single phase 230 Volts, 50 Hz AC supply and mounted on wall or ceiling, complete with all accessories internally prewired and including electrically connection with copper conductor cable of size 0.5 Sqmm (nominal area) complete all as specified and as directed. |
| 27 | S& F in repair Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed. (for Kitchen) |
| 28 | S&F Rechargeable 12W LED bulb B-22 type, CDL/WW with backup complete all as specified and as directed. |
| 29 | M&L for sub main wiring comprising single core , 2 Runs of 4 sqmm nominal cross sectional area,FRLS multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC casing capping/conduit and its fittings complete surface/concealed including provision of 1X4 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete all as specified and as directed. (from meter box to 20/25 Amps Socket) |
| 30 | M&L for sub main wiring comprising single core , 2 Runs of 6 sqmm nominal cross sectional area,FRLS multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC casing capping/conduit and its fittings complete surface/concealed including provision of 1X4 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete all as specified and as directed. |
| 31 | M&L for sub main wiring comprising single core , 2 Runs of 1.5sqmm nominal cross sectional area,FRLS multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in PVC casing capping/conduit and its fittings complete surface/concealed including provision of 1X1.5 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire complete all as specified and as directed. ( For Building Security Light) |
| 32 | S&F of sheet metal board indoor installation IP-54 for fixing meters complete with and including fixing arrangement on duct/brick /PCC foundation with wiring, fittings and accessories, locking arrangement and painting. Size adequate for following equipment, internal wiring copper wire single core not less than 10 sqmm and arrangement for termination of external cables, lugs, glands and conduits as required. Comprising of and including the following :-(a) Incommer MCCB 63Amps 4 pole 16 KA - 01 No(b) Alluminium bus bar 100 Amps TPN mounted on porcelain insulators including bus bar of suitable size upto outgoing MCCB connection.(c ) Taking down old existing meter and fixing old Electronic type Energy meter of any capacity along with New 40 Amps DP MCB in meter box complete-04 Nos. |
| 33 | Taking out MCB DBs from wall of any capacity includind MCBs complete all as specified and as directed. |
| 34 | Supply and fix in repair SP&N DBs, double door, 240 volt, 12 way complete all as specified and as directed. |
| 35 | M&L for MCB single pole, 240 volts, 6 - 32 Amps, 10 KA C Curve complete all as specified and as directed. |
| 36 | Fixing Only MCB single pole, 240 volts, 6 - 32 Amps, 10 KA C Curve complete all as specified and as directed. |
| 37 | M&L for MCB single pole & neutral 240 volts 32Amps C curve. complete all as specified and as directed. |
| 38 | Fixing only MCB single pole & neutral 240 volts 32Amps C curve. complete all as specified and as directed. |
| 39 | Supply and fix sheet metal enclosure single pole and earth encolsure with a three pin and earth plug with socket complete with one single pole MCB of rating 20 Amps, 240Volts complete all as specified and as directed. |
| 40 | Supply and fixing LED building security light fitting 35 Watt, lumen not less than 120/watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and as directed. |
| 41 | Supply & fix exhaust fans steel body AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and as directed. Note: - Old Unserviceable fans shall be deposited to MES store. |
| 42 | M&L for cable in trenches/passing through pipe/on wall , XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 25 sqmm 4 core ncluding taking out old existing complete all as specified and as directed. (Building Panel to meter box) |
| 43 | M&L for cable in trenches/passing through pipe/on wall , XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 35 sqmm 3.5 core including taking out old existing complete all as specified and as directed. (Building Panel to meter box) |
| 44 | M&L for cable in trenches/passing through pipe/on wall , XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 240 sqmm 3.5 core ncluding taking out old existing complete all as specified and as directed. (RA main Panel To Building Panel) |
| 45 | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in Soft / Loose Soil, complete all as specified and as directed. |
| 46 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. |
| 47 | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. |
| 48 | M&L Sand Cushioning (dry) in Trenches for protec-tion of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE :- For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for). |
| 49 | S&F Sub-Class B brick, well burnt, laid breadth-wise along the length of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed. |
| 50 | S&F Galvanised Iron Pipe 50mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 51 | S&F Galvanised Iron Pipe 80mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 52 | Labour only for Boring under roads by manually for Passing Protection Pipe up to 80mm Bore (dia), under Road /Foot Path, and making good to complete all as specified and as directed. Note :- Pipe to be measured separately. |
| 53 | Material and labour for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point complete all as specified and as directed. or indicated including testing on completion |
| 54 | M&L in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.00mm GI wire complete all as specified and as directed. |
| 55 | Supply and Installation of MCCB 3 Pole, 415 V, fixed type, 63 Amps,Ao'J magnetic, Ics=100%Icv, with breaking capacity 25 KA in existing building panel including making suitable arrangement if required for fixing in existing panel and removing of existing MCCB complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 23, 2026
11:30 IST
Tender Published
Tender notice published.
TodayDec 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 28 daysDec 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 30 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender