Tender For Special Repairs/ Replacement Of Old Plain Cement Concrete Poles And Angle Iron Poles To New Street Light Poles And Replacement Of Bollard Lights At Afs Begumpet Under Ge (Af) Hakimpet
Tender Value
58 Lakhs
Estimated cost
Bid Submission
21 Dec 2026
27 days left
EMD
1.12 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs/ Replacement Of Old Plain Cement Concrete Poles And Angle Iron Poles To New Street Light Poles And Replacement Of Bollard Lights At Afs Begumpet Under Ge (Af) Hakimpet
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ 84863/E8 BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Commander Works Engineers (Air Force), Secunderabad Name of Work :- SPECIAL REPAIRS/ REPLACEMENT OF OLD PCC POLES AND ANGLE IRON POLES TO NEW STREET LIGHT POLES AND REPLACEMENT OF BOLLARD LIGHTS AT AFS BEGUMPET UNDER GE (AF) HAKIMPET Contract No: CA NO: CWE/AF(S)/HKPT/TOKEN - 45 OF 2026-2027 SERIAL PAGE NO :- Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SerNo Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | S&F Octagonal shaped GI hot dipped (65 microns) internally and externally as per IS - 2629 minimum 3mm thick electric pole, Polished finished (7 metre long) Single arm bracket(1.5 Mtrs) complete with PCC base, bolts, nuts, washers and base plates including taking down old existing PCC poles/angle iron poles complete all as specified and as directed. and including the following:- |
| 3 | Excavation in post hole not exceeding for pole foundation & getting out in soft loose soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 metres. |
| 4 | M&L for Providing PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation as per manufacturers design upto GL including Nuts, bolts, washers ,PVC pipe for cable and base plates of suitable size and length for grouting in as per manufacturer's design. |
| 5 | Inbuilt internal junction box consists of 4 terminals for cable and outgoing of MCB SP 6 Amps 10 KA complete. Note:- Taking down Old poles cost is deemed to be included in quoted rate by the contractor. |
| 6 | S & F including taking down of automatic street light control switch of 12-15KW three phase (32 amps Per phase) having protection IP-66 using infrared sensor based nature switch for automatic switching of street light. Nature switch operation should be based on natural light lux level, read illuminance level also have part night operation fascility for min 4 hrs to max 12 hrs. The sensor along with suitable rating power contactors, one incomimg MCBs rating of 32 Amps and three out going MCBs TPN of rating 32 Amps& main load circuit wiring of copper min 10 sqmm should be enclosed in a plinth/pole/wall mountable rust proof, termite proof, electrick shock proof, FR grade thermoplastic polycarbonate enclosure IP 66 protection out door type enclosure. The circuit should have also provision of manual operation.(ie sensor Bypass option) complete all as specified and as directed. |
| 7 | Material and labour for 40mm dia bore tubes, 'light grade' galvanised, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and as directed. |
| 8 | M & L for Manual or trenchless technology, boring under Roads / hard standing for taking up or laying of LT UG cable , after laying of cable, well ramming to the excavated soil complete all as specified and as directed. |
| 9 | Supply and fixing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 10 sqmm 4 core including taking down the old unsv cable complete all as specified and as directed. |
| 10 | All as per Item No 5 here in before but 16 Sqmm 4 core complete all as specified and as directed. |
| 11 | All as per Item No 5 hereinbefore but 95Sqmm 3.5 core complete all as specified and as directed. ( MRS to NFS) |
| 12 | All as per Item No 5 here in before but 10 Sqmm 2 core complete all as specified and as directed. (For Bollard Light) |
| 13 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard/dense soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and as directed. |
| 14 | M&L Sand Cushioning (dry) in Trenches for protec-tion of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE :- For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for). |
| 15 | Supply and lay common burnt clay building bricks sub class 'B' of designation 75 laid in trenches as protection to cables complete all as specified and as directed. |
| 16 | Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed. |
| 17 | Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 18 | Supply and fix in repair LED street light fitting 90 Watt, lumen not less than 120/watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and as directed. |
| 19 | Taking down unsv timer switch from the existing street light panel board by disconnecting electrical connection and supply and fix new astronomical digital timer Programmable Switch 24 Hrs including all electrical connections complete all as specified and as directed. Make :- Havells cat No DHTQB01016 /Crab Tree/ CG/L&T/GEC. |
| 20 | S&F in repair Power contactor TP 32 Amps in existing street light control panel complete all as specified and as directed. |
| 21 | Supply and fixing MCCBs 415V, 25KA, thermal magnetic release 4 Pole 40 Amps including taking out old unservicable one complete all as specified and as directed. |
| 22 | Supply and fixing MCCBs 415V, 25KA, thermal magnetic release4 Pole 100 Amps including taking out old unservicable one complete all as specified and as directed. |
| 23 | Supply and fixing MCCB 3 Pole , 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA including taking out old unservicable one complete all as specified and as directed. |
| 24 | Supply and fixing BAMBOO LED BOLLARD 10 Watt light new generation energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power Led as light source including suitable size of PCC foundation(base) complete all as specified and as directed. |
| 25 | S&F in repair 40/50 Watt, Lumen not less than 110/ watt LED Post Top lantern is a weather proof indirect lighting solution which improves horizontal uniformity decorative type, with reduced glare and improved lighting control IP65. complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 21, 2026
17:00 IST