Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #58680463

Tender For Special Repairs To Qtr No. 1, 2, 3, 4 Of Building No. Wl-29, False Ceiling Of Qtr No. 1, 2, 3, 4 Of Building No. Wl-30 (Temporary Re-Appropriated For Aps Kannur), Repairs To Two Water Tank Staging, Provision Of Approach Interlocking Paver

Issued by Statutory Bodies & Commissions/Committees · Kannur, Kerala
Tender Value
43.64 Lakhs
Estimated cost
Bid Submission
10 Dec 2026
15 days left
EMD
87300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kannur → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Qtr No. 1, 2, 3, 4 Of Building No. Wl-29, False Ceiling Of Qtr No. 1, 2, 3, 4 Of Building No. Wl-30 (Temporary Re-Appropriated For Aps Kannur), Repairs To Two Water Tank Staging, Provision Of Approach Interlocking Paver Block From Golden Jubilee Park To Asc Qtrs At Dsc Kannur Under Ge (Army) Trivandrum

BOQ

Name of Work:- SPECIAL REPAIRS TO QTR NO. 1, 2, 3, 4 OF BUILDING NO. WL-29, FALSE CEILING OF QTR NO. 1, 2, 3, 4 OF BUILDING NO. WL-30 (TEMPORARY RE-APPROPRIATED FOR APS KANNUR), REPAIRS TO TWO WATER TANK STAGING, PROVISION OF APPROACH INTERLOCKING PAVER BLOCK FROM GOLDEN JUBILEE PARK TO ASC QTRS AT DSC KANNUR UNDER GE (ARMY) TRIVANDRUM
Sl. No. Item Description
1Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and directed.
2M&L for hardcore of broken stone or boulders, gauge not exceeding 63 mm; deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
3M&L for cement concrete 75 mm thick, type D-2, 1:4:8, using 40 mm graded stone aggregate, for sub base of floor etc. finished even and rough to receive top layer complete all as specified and directed.
4M&L for sand filling under floors or in foundations including watering and consolidation etc. complete all as specified and as directed.
5M&L for machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade, with grey cement and pigment complete all as specified and directed.
6M&L for PCC 1:2:4, type B1 using 20 mm graded stone aggregate, cast-in-situ as in coping and the like including weathering, slightly rounded or chamfered angles and throating etc. including necessary formwork complete all as specified and as directed.
7Removing excavated soil to a distance not exceeding 150 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
8Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) and disposed outside MD land complete all as specified and directed.
9M&L for cement concrete 25 mm thick, type B0, 1:2:4, using 12.5 mm graded aggregate, for sub base of floor etc. complete all as specified and directed.
10M&L for joint free white non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
11M&L for joint free white non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on vertical surfaces as in skirting, dado, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick backing coat in cement mortar (1:4) complete all as specified and directed.
12S&F anodised aluminium snap grid/ GI frame work (size of grid 605 x 605 mm) for false ceiling including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed.
13M&L for 4 mm thick non-asbestos fibre cement building boards fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws in ceiling, flat or sloping complete all as specified and directed.
14M&L for preparation of new surfaces of ceiling and applying two coats of oil bound distemper; over a coat of chalk whiting complete all as specified and as directed.
15M&L for complete removal of existing treatment on wall surfaces preparation of new surfaces of ceiling and applying two coats of oil bound distemper; over a coat of primer complete all as specified and as directed.
16M&L for applying 3mm thick wall care putty in two layers with proper sanding and smoothening of wall surfaces complete all as specified and as directed.
17S&F powder coated anodised aluminium frame in approved shade for doors, windows, ventilators (minimum thickness of powder coating 50 micron), with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
18S&F powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.; aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws including locking system for shutters complete all as specified and as directed.
19S&F powder coated anodised aluminium door shutters (minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
20M&L for 12 mm thick prelaminated particle board interior grade, prelaminated on one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
21S&F 4 mm thick sheet glass, ordinary quality any size and any type of frame and glazing with oil putty (or beading) in square not exceeding 0.5 sqm in each pane complete all as specified and directed.
22S&F 5.5 mm thick sheet glass, ordinary quality any size and any type of frame and glazing with oil putty (or beading) in square not exceeding 0.5 sqm in each pane complete all as specified and directed.
23S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed.
24S&F door closer of aluminium (die cast body), hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
25S&F mortice lock, size 100mm, mild steel, 4 levers, vertical type complete all as specified and directed.
26S&F 100 mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
27S&F 150 mm long aluminium anodised barrel tower bolts of extruded sections complete all as specified and directed.
28S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
29Demolition of brickwork or stone/ boulder masonry built in cement mortar or cement lime mortar, including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work and pre cast concrete articles complete all as specified and as directed.
30Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, in cement mortar 1:4 complete all as specified and directed.
31M&L for RCC (cast-in-situ) 1:2:4, type B1 using 20mm graded stone aggregate, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and as directed.Note: Reinforcement shall be measured and paid separately.
32M&L for use and waste of formwork to rough finished flat surfaces of concrete as in sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams complete all as specified and directed.
33S&F TMT steel bars 10 mm dia and over, cut to length, bent to shape required, as in stirrups, spacers and binders including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
34S&F TMT steel bars 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, as in stirrups, spacers and binders including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
35M&L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work/ concrete surfaces, finished even and smooth complete all as specified and directed.
36M&L for rendering 5 mm thick in cement mortar 1:6 on fair faces of brick work/ concrete surfaces, finished even and smooth complete all as specified and directed.
37M&L for pre-cast cement concrete block masonry type B1, 1:2:4 (using 20mm graded stone aggregate) with solid blocks exceeding 10 cm in width and setting in CM 1:4 complete all as specified and as directed
38S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed
39M&L for 35 mm thick 2nd class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
40S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
41M&L for preparation of old wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
42S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work; portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. confirming to Fe.290.Gde-E-165 complete all as specified and directed.
43M&L for preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide/ zinc chrome primer complete all as specified and directed.
44Taking down chowkats or frames with shutters any description not exceeding 1.5 sqm each (without taking off shutters from the frame) complete all as specified and directed.
45Taking down chowkats or frames with shutters any description exceeding 1.5 sqm but not exceeding 4 sqm each (without taking off shutters from the frame) complete all as specified and directed.
46Taking down shutters of any description exceeding 1 sqm but not exceeding 2 sqm each complete all as specified and directed.
47Taking down cement or cement lime plaster any description, on brick/ concrete/ stone walls including raking out joints, hacking for key, scrubbing down with water etc. and removing rubbish outside MD land complete all as specified and as directed.
48M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work/ concrete surfaces, finished even and smooth complete all as specified and directed.
49M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied at the rate of 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
50Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
51S&F rolled mild steel as in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. confirming to Fe.410-W.Gde-E-250.Quality-A complete all as specified and directed.
52S&F rolled mild steel as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe.410-W.Gde-E-250.Quality-A complete all as specified and directed.
53Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
54Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
55M&L for cement concrete, type B2, 1:2:4 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed
56Dismantling water tanks not exceeding 250 Ltrs and removing to store complete all as specified and directed.
57S&F rotational moulded polyethylene water storage tanks of 500 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
58S&F 20 mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
59Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
60M&L for providing and fixing gypsum board 12 mm thick in ceiling fixed with screw as per manufacturer's instructions complete all as specified and directed.
61M&L for cutting opening of existing gypsum ceiling not exceeding 1 sqm and checking for sagging and providing necessary strengthening by screwing or giving additional support and repairing that patch and sealing the joints with best quality glass fibre tape and gypsum ceiling jointing compound followed by smoothening the joints by sanding and finishing with putty complete all as specified and directed.Note: Gypsum board shall be measured and paid separately.
62M&L for preparation of old surfaces of ceiling and applying two coats of oil bound distemper complete all as specified and as directed.
63M&L for preparation of old surfaces of wall and applying two coats of oil bound distemper complete all as specified and as directed.
64S&F 4 mm thick frosted sheet glass, ordinary quality any size and any type of frame and glazing with oil putty (or beading) in square not exceeding 0.5 sqm in each pane complete all as specified and directed.
65Supply only neoprene/ EPDM rubber gasket complete all as specified and directed.
66S&F 100 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
67Supplying, laying and jointing 25 mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 including all necessary pipe fittings such as bends, elbows, tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs etc. fixed complete to walls, ceilings or in floors etc., complete all as specified and directed.
68Supplying, laying and jointing 20 mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 including all necessary pipe fittings such as bends, elbows, tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs etc. fixed complete to walls, ceilings or in floors etc., complete all as specified and directed.
69Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. complete all specified and directed.
70M&L for point wiring complete for one light point controlled by one way switch with two runs (phase and neutral) of 1.5 sqmm single core PVC insulated unsheathed FRLS cable ,1100 volts grade with multi stranded, copper conductor drawn through and including non-metallic rigid PVC concealed conduit medium grade, complete and including necessary fixing accessories such as bend, elbow, socket, saddles etc. including provision of factory made galvanised pressed steel terminal boxes of 16 gauge thickness, modular white cover with frame fixed with screws for housing switches, socket outlets, fan regulators etc., with and including 1.5 sqmm single core PVC insulated unsheathed copper conductor FRLS cable, 1100 Volts grade green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.Notes: (i) Wiring shall be done in proper colour coding i.e. Red, Yellow, Blue for phases and black for neutral and green for earth.(ii) Cost of modular metal flush boxes, modular frame of suitable module/ size concealed in wall for mounting switches/ sockets, regulators, bell push etc. (iii) Modular fittings such as switches, sockets, fan regulator etc. shall be measured and paid separately.
71All as per item No. 70.00 here-in-before, but for one fan point controlled by one way switch complete all as specified and directed.
72All as per item No. 70.00 here-in-before, but for one socket outlet, 3/ 5 pin 5 Amp on independent board complete all as specified and directed.
73All as per item No. 70.00 here-in-before, but for one socket outlet, 3/ 5 pin 5 Amp on same board complete all as specified and directed.
74All as per item No. 70.00 here-in-before, but for one socket outlet, 3/5 pin 15 Amp on independent board with 2.50 sqmm FRLS copper conductor cable and 2.50 sqmm copper conductor cable as earth continuity conductor green in colour complete all as specified and directed.
75S&F modular switch, one way 6 Amp, one module including connecting up electrically complete all as specified and directed.
76S&F modular socket, 6 Amp, 2/3 pin, combined two module including connecting up electrically complete all as specified and directed.
77S&F modular switch, one way 16 Amp, one module including connecting up electrically complete all as specified and directed.
78S&F modular socket, 6/16 Amp, 2/3 pin, combined two module including connecting up electrically complete all as specified and directed.
79S&F lamp holder, insulated body of PVC/ polycarbonate type with back plate suitable for angle/ batten fittings complete all as specified and directed.
80S&F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body including connecting up electrically complete all as specified and directed.
81S&F modular fan step regulator, 120W, 2 module including connecting up electrically complete all as specified and directed.
82S&F LED batten extruded aluminium body with PC diffuser in unique square shape >120 degree wide distribution, 4 feet 20 Watts of minimum efficacy 120 Lumen/ Watts, CCT 6500 K complete including connection upto ceiling rose with flexible copper twin twisted wire including taking down old unserviceable light fitting complete all as specified and directed.
83S&F LED batten extruded aluminium body with PC diffuser in unique square shape >120 degree wide distribution, 2 feet 10 Watts of minimum efficacy 120 Lumen/ Watts, CCT 6500 K complete including connection upto ceiling rose with flexible copper twin twisted wire including taking down old unserviceable light fitting complete all as specified and directed.
84S&F in replacement submain wiring with using two single core 6.0 sqmm copper multi-stranded conductor PVC insulated and unsheathed (FRLS) cable and one single core 6.0 Sqmm copper multi-stranded conductor PVC insulated and unsheathed (FRLS) earth wire using ISI marked IS 694, 1100 volts grade PVC insulated stranded copper conductor wire drawn through with and including medium grade concealed PVC conduit ISI marked not less than 25 mm dia including conduit fitting and accessories complete all as specified and directed. Notes:- (i) Two runs of 6.0 sqmm cable and one run of 6.0 sqmm earth wire drawn inside the conduit of suitable size shall be measured as one unit.(ii) Proper colour coding shall be used. The complete combination of all three wires (Phase, Neutral, and Earth) inside the conduit shall be considered as one unit.
85S&F MCB SP 6 to 32 Amps, breaking capacity 10 KA, 'B' curve, 240 volts, 50 Hz complete with connection, testing and commissioning all as specified and directed.
86S&F RCBO, double pole, 300 mA, 40 Amps complete with connection, testing and commissioning all as specified and directed.
87S&F in repair MCB TPN 63 Amps, breaking capacity 10 KA, 'C' curve, 415 volts, 50 Hz complete with connection, testing and commissioning all as specified and directed.
88S&F double door MCB SPN distribution board with steel sheet powder coated DB 8 Ways with 200 amps rated bus bar suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirming to IS 13032- 1991 complete including taking down MCB DBs and MCBs and making good the disturbed surfaces complete all as specified and directed.
89S&F in repair double door MCB TPN distribution board with steel sheet powder coated DB 4 Ways suitable for MCB fitted with bus bar neutral link earth bar and din rail 415 volts and neutral confirming to IS 13032- 1991 complete including making good the disturbed surfaces complete all as specified and directed.
90S&F LED lamp 15 watts of minimum efficacy 120 Lumen/ Watts complete all as specified and directed.
91Taking down ceiling fan of any size or sweep, sealing cable end and dismantling blades for painting complete all as specified and directed.
92Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
93M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed.
94Taking down old existing electric energy meters from site, depositing in MES store and refixing the same at its original position after completion of other maintenance works in the building complete all as specified and directed. Please Enable Macros to View BoQ information
95Taking down old existing electric energy meters from site, depositing in MES store and refixing the same at its original position after completion of other maintenance works in the building complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58680463
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.64 Lakhs
LAST DATE 10-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repairs To Qtr No. 1, 2, 3, 4 Of Building No. Wl-29, False Ceiling Of Qtr No. 1, 2, 3, 4 Of Building No. Wl-30 (Temporary Re-Appropriated For Aps Kannur), Repairs To Two Water Tank Staging, Provision Of Approach Interlocking Paver Block From Golden Jubilee Park To Asc Qtrs At Dsc Kannur Under Ge (Army) Trivandrum
Basic Detail
Tender No 8417/E8
Bidding Type Tender
Location
City Kannur
State Kerala
Key Dates
Publish Date 23 Nov 2026
Submission Date 10 Dec 2026
Open Date 12 Dec 2026
Finance
Tender Value 43.64 Lakhs
Tender Fee 500
EMD 87300
Exemption Available
Document List
71de85b4-0aba-4409-846b-893c15c68007.html
8417Tender.pdf
BOQ_897570.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Dec 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.