Tender For Operation And Maintenance Of Online Continuous Effluent Monitoring Systems(Ocems) At Chinnandipalayam 20Mld Sewagetreatment Plant (Stp) In Tiruppur City Municipal Corporation For A Period Of One Year.
Tender Value
33.30 Lakhs
Estimated cost
Bid Submission
14 Dec 2026
17 days left
EMD
66600
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tiruppur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Operation And Maintenance Of Online Continuous Effluent Monitoring Systems(Ocems) At Chinnandipalayam 20Mld Sewagetreatment Plant (Stp) In Tiruppur City Municipal Corporation For A Period Of One Year.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing and commissioning of Multiparameter water quality monitoring for COD, BOD, TSS and pH with RS485 output, 90-230V power supply and Sampling Pump. COD: 0-1000 ppm, BOD: 0-1000 ppm, TSS: 0-500 ppm, pH: 0-14. The OCEMS analyzer offered shall hold a valid CE certification and a valid global certification such as TUV, MCERTS or USEPA. The certificates shall be for the quoted make and model and valid on the bid submission date. Documents required are the CE certificate, the TUV/MCERTS/USEPA certificate, and the datasheet or test report supporting them. Extractive-method continuous monitoring of COD, BOD, pH, TSS at plant outlet. Capacity to add parameters later (turbidity, conductivity, TDS, oil in water). Complete analyzer with sample handling system; pump, tubing and accessories in contractor scope. Inbuilt automatic cleaning, USB port for data download, diagnostic files and software update. Minimum 3 months data storage in non-volatile memory. Communication ports for PLC/SCADA integration; RS232 or RS485 output. COD: 0–1000 mg/L (min), accuracy ±2% on standard solution, repeatability ±1 mg/L, response < 5 min. BOD: 0–100 mg/L (min), accuracy ±5% on standard solution, repeatability ±0.2 mg/L, response < 5 min. TSS: 0–1000 mg/L (min), accuracy ±2% on standard solution, repeatability ±1 mg/L, response < 5 min. pH: 0–14, accuracy ±2% on standard solution, repeatability ±0.01 pH, response < 1 min, electrochemical method. Temperature: 0–80 °C, accuracy and resolution ≤ 0.1 °C. Xenon flash lamp UV source, life above 10 years. Colour LCD with LED backlight, resistive touch screen. Power supply 90–264 VAC, 50/60 Hz. Enclosure IP65 minimum cabinet type, or IP68 if not cabinet type. Sample temperature 0–80 °C; measuring cycle continuous; programmable interval 1 min. Automatic zero calibration at user-defined interval; span calibration per laboratory data. |
| 2 | Robust flow cell that handles high suspended solids and corrosive samples without clogging. Should be capable of operating unattended over prolonged period of time. Should produce analytically valid results with precision and repeatability. The instrument/analyser should be robust and rugged, for optimal operation under extreme environmental conditions, while maintaining its calibrated status. The analyser should have inbuilt features for automatic water matrix change adaption. The instrument/analyser should have onboard library of calibration spectras for different industrial matrices with provision of accumulating further calibration matrices. Should have data validation facility with features to transmit raw and validated data to central server. Should have provision to send system alarm to central server in case any changes made in configuration or calibration. Should have provision to record all operation information in log file (minimum 5000 lines). Should have provision of plant-level data viewing and retrieval with selection of ethernet, wireless, Modbus and USB. In case of TOC analyser, the empirical relationship between TOC to COD or BOD must be authenticated for all industrial applications and the correlation calculation (for factor) shall be provided. That the record of calibration and validation should be available on real-time basis on central server from each analyser. Record of online diagnostic features including sensor status should be available in database for user-friendly maintenance. Expandable program to calculate parameter load daily, weekly or monthly basis for future evaluation with flow rate signal input. Must have low operation and maintenance requirements with low chemical consumption and recurring cost of consumables and spares. |
| 3 | Supply of COD module, for online COD measurement by UV absorbance, with BOD and TSS reported as values derived from site-specific correlation. |
| 4 | Supply of online pH sensor, with cable, compatible with the module. |
| 5 | Supply of sampling pump, with mounting provisions, sample tubing and fittings etc., |
| 6 | Supply, Installation, Testing and commissioning of Electromagnetic Flow meter at the outlet as per above specifications (200 mm) |
| 7 | Supply, Installation, Testing and commissioning of Data Transfer Device compliant to CPCB/TNPCB Data Connectivity.(NEO ENVIRO-4G) Version -01 |
| 8 | Operation and maintenance of Online Continuous Effluent Monitoring Systems(OCEMS) at Chinnandipalayam 20MLD SewageTreatment plant (STP) in Tiruppur City Municipal Corporation for a period of one year. |
| 9 | Add GST 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysDec 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender