Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #58676119

Tender For Repair /Maintenance Of Acs, Cooling Appliances And Voltage Stabilizers At installation Pallava Under Ge (Navy) Chennai

Issued by Statutory Bodies & Commissions/Committees · Chennai, Tamil Nadu
Tender Value
3 Lakhs
Estimated cost
Bid Submission
12 Dec 2026
13 days left
EMD
6000
Bank guarantee accepted
Document Fee
300
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair /Maintenance Of Acs, Cooling Appliances And Voltage Stabilizers At installation Pallava Under Ge (Navy) Chennai

BOQ

Name of Work:- REPAIR /MAINTENANCE OF ACs, COOLING APPLIANCES AND VOLTAGE STABILIZERS AT INS PALLAVA UNDER GE (NAVY) CHENNAI
Sl. No. Item Description
1Checking and testing of split AC any capacity including Leak arresting, cleaning complete etc.
2Dismantling the unserviceable Outdoor unit from the split type unit and replacement with new outdoor unit (Includes compressor,condenser coil, condenser fan motor etc.) with suitable refrigerant gas support(R32/R410A/R22) of BEE 3 star rating 1.5 ton capactiy complete all as specified and directed.
3All as per Sl item No 2.00 herein before but of 2.0 Ton capacity complete all as specified and directed. Note for item 1 to 3 : Gas shall be measured and paid for separately.
4Dismantling the unserviceable uncut rotary compressor from the split type AC unit and replacement with new rotary compressor 1.5 Ton capacity and including servicing the entire unit complete all as specified and directed.
5All as per Sl item No 04.00 herein before but suitable for 2.0 Ton capacity.Note for item 4 & 5 : Gas shall be measured and paid for seperatly.
6Replacement of Unserviceable remote control suitable for 1.5/2.00 ton capacity Split type AC of any make complete all as specified and directed.
7All as per Sl item No 06.00 herein before but Electronic PCB board any type.
8All as per Sl item No 06.00 herein before but fan motor 1.5/2 ton capacity.
9All as per Sl item No 06.00 herein before but Condenser coil and including servicing the entire unit.
10All as per Sl item No 06.00 herein before but suction valve,
11All as per Sl item No 06.00 herein before but discharge valve
12All as per Sl item No 06.00 herein before but Indoor unit blower motor of 1.5/2.0 ton capactiy
13All as per Sl item No 06.00 herein before but PVC drain pipe flexible type of suitable size
14All as per Sl item No 06.00 herein before but fan blade set
15Replacement of new indoor unit for split type AC 1.5 ton capactiy and including servicing the entire unit of any make complete all as specified and directed as per the existing make and model.
16Replacement of new indoor unit for split type AC 2.0 ton capactiy and including servicing the entire unit of any make complete all as specified and directed as per the existing make and model.
17Matrial and labour for Spray painting to the whole out door unit of split type air conditioner 1.5/2.0 Ton with two coats of synthetic enamel paint after cleaning the unit assembly with caustic soda wash complete and including servicing the entire unit all as specified and directed.
18Shifting of split type Air conditioner any capacity including supply & fixing of factory fabricated support suitable to mount out door unit (one pair per AC) and duly making holes into wall for insertion of copper pipe,drain pipe and 3 core cable,and making good the distrubed surfaces complete and including servicing the entire unit all as specified and directed.
19Dismantling the unserviceable uncut hermitically sealed compressor from the water cooler unit and replacing with factory re-conditioned hermitically sealed compressor for water cooler any make up to 40/80 ltr capacity and including servicing the entire unit complete all as specified and directed. Note :Gas shall be measured and paid separately .
20Supply and fix Starting relay for 40 to 150 liters water cooler including dismantiling the old unserviceable one and servicing the entire unit complete all as specified and directed.
21All as per Sl item No 20.00 herein before but over load protecto
22All as per Sl item No 20.00 herein before but thermostat.
23All as per Sl item No 20.00 herein before but Fan blade assembly suitable.
24All as per Sl item No 20.00 herein before but push cock brass chromium plated of size 15mm.
25All as per Sl item No 20.00 herein before but branded new fan motor with base for suitable capacity
26All as per Sl item No 20.00 herein before but top lid gasket for 80/120 Ltr capacity
27All as per Sl item No 20.00 herein before but drain stainless steel tray with drain elbow and connector
28All as per Sl item No 20.00 herein before but Gate valve brass screwed both ends of size 15mm bore
29All as per Sl item No 20.00 herein before but Float valves brass with PVC ball complete suitable for 15mm bore, ISI marked
30All as per Sl item No 20.00 herein before but PVC hose connection pipe with both ends having brass coupling threaded for 15mm GI tubing of standard length
31Material and labour for painting of water cooler with two coats of pastel blue paint to the external surfaces of water cooler and Two coats of anticorrosive black paint over a coat of red oxide primer upto 15 cm height from the base allround including legs for inside of water cooler, of any capacity and including servicing the entire unit all as specified and directed.
32Taking out the voltage stablizer of any make and of capacity 4/5 KVA from site and transporting to servicing centre to detect /identify the nature of defects/repairs and reassembling after repair/servicing and commissioning at site including testing the same to the entire satisfaction of Engineer-in-Charge complete all as specified and directed.
33All as per Sl item No 32.00 herein before but capactity upto 3 KVA.
34Dismantling the burnt out transformer from the 5 KVA capacity stablizer of any make and rewinding the same with supper enameled copper wire including provision of all materials and refixing into the stablizer and testing to the entire satisfaction of Engineer-in-Charge and testing complete all as specified and directed.
35All as per Sl item No 34.00 herein before but capactity 4 KVA.
36Supply and fixing relay set of two for voltage stabilizer up to 5 KVA capacity complete all as specified and directed.
37All as per Sl item No 36.00 herein before but PCB(Printed circuit board).
38All as per Sl item No 36.00 herein before but 3 core flexible card 2.5 sqmm
39All as per Sl item No 36.00 herein before but indicating lamp
40All as per Sl item No 36.00 herein before but on/off switch
41Supply and fix copper pipe 1/2\\" dia for all summer appliances of any capacity including dismantling the unserviceable pipe complete all as specified and directed.
42All as per Sl item No 41.00 herein before but size 1/4\\" dia
43Supply & Fixing three core flexible cord copper wire of size 4 Sqmm, complete all as specified and directed.
44Supply & Fixing two pin sheet metal earth plug top and metal clad socket 20 Amps capacity complete all as specified and directed.
45Supply & Fixing single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with single pole MCB 20 Amps for incoming and out going control complete all as specified and directed.
46Supply & Fixing MCB SP 20/25 Amps 240 Volts 10 KA breaking capacity complete all as specified and directed.
47Material and labour for replacement of unserviceable UPVC conduit pipe 20mm dia to drain out pipe including all accessories and taking down the existing one, with fixing arrangment on wall, ceiling etc.,complete all as specified and directed.
48Supply only Refrigerant Gas R-32 all as specifed and directed.
49Supply only Refrigerant Gas R-22 all as specifed and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58676119
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 3 Lakhs
LAST DATE 12-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair /Maintenance Of Acs, Cooling Appliances And Voltage Stabilizers At installation Pallava Under Ge (Navy) Chennai
Basic Detail
Tender No 8869/E8
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 23 Nov 2026
Submission Date 12 Dec 2026
Open Date 14 Dec 2026
Finance
Tender Value 3 Lakhs
Tender Fee 300
EMD 6000
Exemption Available
Document List
8869GENERALPAGES.pdf
8869PS.pdf
bcc36c7e-da90-4b92-b00c-3c2d3e024ec6.html
BOQ_897537.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Dec 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
pdf

8869GENERALPAGES.pdf

pdf

8869PS.pdf

html

bcc36c7e-da90-4b92-b00c-3c2d3e024ec6.html

xls

BOQ_897537.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender