Tender For Repair /Maintenance Of Acs, Cooling Appliances And Voltage Stabilizers At installation Pallava Under Ge (Navy) Chennai
Tender Value
3 Lakhs
Estimated cost
Bid Submission
12 Dec 2026
13 days left
EMD
6000
Bank guarantee accepted
Document Fee
300
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair /Maintenance Of Acs, Cooling Appliances And Voltage Stabilizers At installation Pallava Under Ge (Navy) Chennai
BOQ
| Sl. No. | Item Description |
| 1 | Checking and testing of split AC any capacity including Leak arresting, cleaning complete etc. |
| 2 | Dismantling the unserviceable Outdoor unit from the split type unit and replacement with new outdoor unit (Includes compressor,condenser coil, condenser fan motor etc.) with suitable refrigerant gas support(R32/R410A/R22) of BEE 3 star rating 1.5 ton capactiy complete all as specified and directed. |
| 3 | All as per Sl item No 2.00 herein before but of 2.0 Ton capacity complete all as specified and directed. Note for item 1 to 3 : Gas shall be measured and paid for separately. |
| 4 | Dismantling the unserviceable uncut rotary compressor from the split type AC unit and replacement with new rotary compressor 1.5 Ton capacity and including servicing the entire unit complete all as specified and directed. |
| 5 | All as per Sl item No 04.00 herein before but suitable for 2.0 Ton capacity.Note for item 4 & 5 : Gas shall be measured and paid for seperatly. |
| 6 | Replacement of Unserviceable remote control suitable for 1.5/2.00 ton capacity Split type AC of any make complete all as specified and directed. |
| 7 | All as per Sl item No 06.00 herein before but Electronic PCB board any type. |
| 8 | All as per Sl item No 06.00 herein before but fan motor 1.5/2 ton capacity. |
| 9 | All as per Sl item No 06.00 herein before but Condenser coil and including servicing the entire unit. |
| 10 | All as per Sl item No 06.00 herein before but suction valve, |
| 11 | All as per Sl item No 06.00 herein before but discharge valve |
| 12 | All as per Sl item No 06.00 herein before but Indoor unit blower motor of 1.5/2.0 ton capactiy |
| 13 | All as per Sl item No 06.00 herein before but PVC drain pipe flexible type of suitable size |
| 14 | All as per Sl item No 06.00 herein before but fan blade set |
| 15 | Replacement of new indoor unit for split type AC 1.5 ton capactiy and including servicing the entire unit of any make complete all as specified and directed as per the existing make and model. |
| 16 | Replacement of new indoor unit for split type AC 2.0 ton capactiy and including servicing the entire unit of any make complete all as specified and directed as per the existing make and model. |
| 17 | Matrial and labour for Spray painting to the whole out door unit of split type air conditioner 1.5/2.0 Ton with two coats of synthetic enamel paint after cleaning the unit assembly with caustic soda wash complete and including servicing the entire unit all as specified and directed. |
| 18 | Shifting of split type Air conditioner any capacity including supply & fixing of factory fabricated support suitable to mount out door unit (one pair per AC) and duly making holes into wall for insertion of copper pipe,drain pipe and 3 core cable,and making good the distrubed surfaces complete and including servicing the entire unit all as specified and directed. |
| 19 | Dismantling the unserviceable uncut hermitically sealed compressor from the water cooler unit and replacing with factory re-conditioned hermitically sealed compressor for water cooler any make up to 40/80 ltr capacity and including servicing the entire unit complete all as specified and directed. Note :Gas shall be measured and paid separately . |
| 20 | Supply and fix Starting relay for 40 to 150 liters water cooler including dismantiling the old unserviceable one and servicing the entire unit complete all as specified and directed. |
| 21 | All as per Sl item No 20.00 herein before but over load protecto |
| 22 | All as per Sl item No 20.00 herein before but thermostat. |
| 23 | All as per Sl item No 20.00 herein before but Fan blade assembly suitable. |
| 24 | All as per Sl item No 20.00 herein before but push cock brass chromium plated of size 15mm. |
| 25 | All as per Sl item No 20.00 herein before but branded new fan motor with base for suitable capacity |
| 26 | All as per Sl item No 20.00 herein before but top lid gasket for 80/120 Ltr capacity |
| 27 | All as per Sl item No 20.00 herein before but drain stainless steel tray with drain elbow and connector |
| 28 | All as per Sl item No 20.00 herein before but Gate valve brass screwed both ends of size 15mm bore |
| 29 | All as per Sl item No 20.00 herein before but Float valves brass with PVC ball complete suitable for 15mm bore, ISI marked |
| 30 | All as per Sl item No 20.00 herein before but PVC hose connection pipe with both ends having brass coupling threaded for 15mm GI tubing of standard length |
| 31 | Material and labour for painting of water cooler with two coats of pastel blue paint to the external surfaces of water cooler and Two coats of anticorrosive black paint over a coat of red oxide primer upto 15 cm height from the base allround including legs for inside of water cooler, of any capacity and including servicing the entire unit all as specified and directed. |
| 32 | Taking out the voltage stablizer of any make and of capacity 4/5 KVA from site and transporting to servicing centre to detect /identify the nature of defects/repairs and reassembling after repair/servicing and commissioning at site including testing the same to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. |
| 33 | All as per Sl item No 32.00 herein before but capactity upto 3 KVA. |
| 34 | Dismantling the burnt out transformer from the 5 KVA capacity stablizer of any make and rewinding the same with supper enameled copper wire including provision of all materials and refixing into the stablizer and testing to the entire satisfaction of Engineer-in-Charge and testing complete all as specified and directed. |
| 35 | All as per Sl item No 34.00 herein before but capactity 4 KVA. |
| 36 | Supply and fixing relay set of two for voltage stabilizer up to 5 KVA capacity complete all as specified and directed. |
| 37 | All as per Sl item No 36.00 herein before but PCB(Printed circuit board). |
| 38 | All as per Sl item No 36.00 herein before but 3 core flexible card 2.5 sqmm |
| 39 | All as per Sl item No 36.00 herein before but indicating lamp |
| 40 | All as per Sl item No 36.00 herein before but on/off switch |
| 41 | Supply and fix copper pipe 1/2\\" dia for all summer appliances of any capacity including dismantling the unserviceable pipe complete all as specified and directed. |
| 42 | All as per Sl item No 41.00 herein before but size 1/4\\" dia |
| 43 | Supply & Fixing three core flexible cord copper wire of size 4 Sqmm, complete all as specified and directed. |
| 44 | Supply & Fixing two pin sheet metal earth plug top and metal clad socket 20 Amps capacity complete all as specified and directed. |
| 45 | Supply & Fixing single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with single pole MCB 20 Amps for incoming and out going control complete all as specified and directed. |
| 46 | Supply & Fixing MCB SP 20/25 Amps 240 Volts 10 KA breaking capacity complete all as specified and directed. |
| 47 | Material and labour for replacement of unserviceable UPVC conduit pipe 20mm dia to drain out pipe including all accessories and taking down the existing one, with fixing arrangment on wall, ceiling etc.,complete all as specified and directed. |
| 48 | Supply only Refrigerant Gas R-32 all as specifed and directed. |
| 49 | Supply only Refrigerant Gas R-22 all as specifed and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysDec 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender