Road Transport and Highways Government Departments Closing in 28 days TDR #58672306

Tender For Reconstruction Work Of Madhalo (Nh-19) To Alakadiha Pwd Path Bhaya Khetko Path (Total Length - 7.800 Km.) Under Road Division, Giridih, Transferring It From Rural Work Department To Road Construction Department For (Including Construction

Issued by Government Departments · Giridih, Jharkhand
Tender Value
30.30 Crore
Estimated cost
Bid Submission
21 Dec 2026
28 days left
EMD
30.31 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Giridih → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Reconstruction Work Of Madhalo (Nh-19) To Alakadiha Pwd Path Bhaya Khetko Path (Total Length - 7.800 Km.) Under Road Division, Giridih, Transferring It From Rural Work Department To Road Construction Department For (Including Construction Of Bridges, Land Acquisition, Utility Shifting And Plantation) For The Year 2026-27

BOQ

Name of Work:- Reconstruction work of Madhalo (NH-19) to Alakadiha PWD Path Bhaya Khetko Path (Total Length – 7.800 Km.) under Road Division, Giridih, Transferring it from Rural Work Department to Road Construction Department for (Including Construction of Bridges, Land Acquisition, Utility Shifting and Plantation) For The Year 2026-27
Sl. No. Item Description
1Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary soil Mechanical MeansDepth upto 3m (I)ORDINARY SOIL G+Drain+Culvert)
2Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications.(PCC Grade M15 using batching plant & Concrete pump)
3Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications PCC Grade M15 using batching plant, transit mixer & concrete pump
4Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.
5Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification do-do all complete job as per E/I. (RCC Grade M25 deck slab)
6Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
7Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications pcc M20, using batching plant Transit Mixture and Concrete pump.
8Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
9Brick masonry work in 1:3 in substructure complete excluding pointing and plastering, as per drawing and Technical Specifications
10Plastering with cement mortar (1:3) on brick work in substructure as per technical specifications
11Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
12Providing Tarphelt cushion under the deck slab
13Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications.
14Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight
15Numbering and writing the Culvert no
16Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications( RCC Grade M20)(Drain)
17Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification(Drain Cover)RCC Grade M30 Using Batching Plant,Transite Mixer and Concrete Pump.(Drain)
18Supplying, fitting and placing HYSD bar reinforcement in sub structure complete as per drawing and technical specifications(Drain)
19Providing and laying of filter media with granular materials/stones crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment , wing wall and return wall to the full height compacted to a firm condition complete as per drwaing and technical specification.(GW+culvert)
20PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)(culvert+Drain+GW)
21Back filling behind abutment, wing wall, return wall complete as per drawing and technical specifications do-do all complete job as per E/I. Granular Material
22Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment , wing wall/ returen wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20 H towards drawing face. Complete as per drawing and technical specifications.
23Cutting of trees stacking of serviceble material with all lifts and up to a lead of 1000 metres. (i) Girth from 300mm to 600mm
24Cutting of trees stacking of serviceble material with all lifts and up to a lead of 1000 metres. (ii) Girth from 600mm to 900mm
25Cutting of trees stacking of serviceble material with all lifts and up to a lead of 1000 metres. (iii) Girth from 900mm to 1800mm
26Cutting of trees stacking of serviceble material with all lifts and up to a lead of 1000 metres. (iii) > 1800mm
27Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, sapling and tress girth upto 300 mm, removal of stumps of tree cut earlier and disposal of unserviceable materials and stacking of sericeable material to be used of auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150mm in thickness.
28Removal of telephone/ Electric Poles and Lines
29Removal of hand Pump
30Excavation for road work in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and tranporting to the embankment location within all lifts and lead upto 1000 m
31Construction of Embankment with approved material obtained from Borrow pits with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300-2.
32Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300-2.
33Construction of sub-grade and earthen shoulders with approved material obtained from Borrow pits with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300-2.
34Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. Gr. - V
35Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
36Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means.
37Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
38Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
39Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @4.5 percent by weight of total mix and filler, transporting the hot mix to work site laying with a hydrostatic paver finisher with sensor control to the required grade level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 505 complete in all respects with VG-30 Bulk Bitumen.
40Providing and laying bituminous concrete with higher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment , rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 507 complete in all respects.
41Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)
42Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
43Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with approve grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
44Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 90cm Equilateral Triangle
45Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 60 x 60cm square
46Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 80 x 60cm Rectangular
47Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 60 x 45cm Rectangular
48Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 60cm Circular
49Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 90cm high Octagonal
50Direction and Place Identification Signs upto 0.9 sqm Size Board.(Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4 mm with area not exceeding 0.9 sqm fixed over back support frame of min 35 x 35 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing)
51Printing New Letter and Figures of any Shade (Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade)
52Kilometre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc)5KM.stone
53Kilometre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc)ordinary KM stone
54Solar Powered Road Marker (Solar Stud) Supplying of Solar Raised Pavement Markers made of polycarbonate molded body with circular shape, solar powered, LED self illumination in active mode 360 degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode.The marker shall support a load of 20000 kg tested in accordance to ASTM D 4280.The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand temperatures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow (amber) as per requirement and typical frequency of blinkikng in 1 Hz.There should be current losses of less than 20 microamperes at 2.4 V in sleepcharging mode to enhace the life of the marker and a full charge should provide for a minimum autonomy of 50 hours.The height, width and length of the marker shall not be less than 10mmx100mmx100 mm. Also, the surface diameter of the marker shall not be less than 100 mm respectively.The weight of the marker shall not exceed 0.5 Kilograms.Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the engineer.)
55Road Delineators (Supplying and installation of delineators (Road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and conforming to IRC-79 and the drawings.)
56Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concree, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with allk lifts and lead of 1000 metres(Dismantling Brick/ tile work )
57Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concree, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with allk lifts and lead of 1000 metres(Cement concrete Grade M-15 & M-20)
58Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concree, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with allk lifts and lead of 1000 metres(Prestressed/ Reinforced cement concrete grade M-20 & above )
59Removing all type of Hume pipes and stacking within a lead of 1000 metres including Earthwork and Dismantling of Masonry Works.
60Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately
61Overhead Signs (Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans & as per IRC: 67)
62Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications(.RCC Grade M20 using batching plant, transit mixture & Concrete pump)
63Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications.
64Fixing of reflectiv sheetingIncluding all costof materialand fitting charge completeWorks as perSpecification direction of E/I
65Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.(Weathered Rock)
66Carrying out excavation in hard rock to achieve a specified slope of the rock face by controlled use of explosives and blasting accessories in properly aligned and spaced drill holes, collection of the excavated rock by a dozer, loading in tipper by a front end loader and disposing of the material with all lifts and lead upto 1000m, all as specified in clause No. 303
67Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications. (P.C.C M15)
68Filling Annular Space around footing in rock.
69Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications. (RCC Grade M30 using batching plant,transit mixer & Concrete pump)
70Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications (Height upto 5m)
71Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications( Height upto 5m to 10m)
72Supplying, fitting and placing HYSD bar reinforcement in sub structure complete as per drawing and technical specifications
73PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification(PCC Grade M15 using batching plant & Concrete pump )
74Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification(For T-beam & slab, 23-33 per cent of (a+b+c) ) Height upto 5m(R.C.C M35)
75Provision of an Reinforced cement concrete crash barrier at the bridge decks& approaches to bridge structures constructed with Rein forced Cement Concrete With HYSD reinforcement confirming MoRT&H Specification and as per details given IRC-5 including dowel bars ,expansion joints filled with pre-moulded asphalt filler board etc.. and approved drawing and at locations directed by the Engineer ,all as specified (.Crash Barriers for Bridge (Height 1100 mm) as per detais given IRC-5 (fig.-2 ) (Area -0.298 sqm. For 1 meter length )
76Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification
77Drainage spouts complete as per Drawing and Technical Specifications.
78Supplying , fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) section IX and clause 2005 of Mort&H specification complete including all accessories as per drwaing and technical specifications
79Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
80Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.
81Providing and laying pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications.
82Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification
83CONFIRMATORY BORING
84Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm.
85Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications.(RCC Grade M25 using batching plant,transit mixer & Concrete pump)
86Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications (RCC Grade M25)
87Add 18% GST (In Basic Rate must fill 0.12)
88Add 1% Labour Cess (In Basic Rate must Rate fill 0.01) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58672306
AUTHORITY Government Departments
TENDER VALUE 30.30 Crore
LAST DATE 21-12-2026
Authority
Authority Name Road Construction Department
Work Description Tender for Reconstruction Work Of Madhalo (Nh-19) To Alakadiha Pwd Path Bhaya Khetko Path (Total Length - 7.800 Km.) Under Road Division, Giridih, Transferring It From Rural Work Department To Road Construction Department For (Including Construction Of Bridges, Land Acquisition, Utility Shifting And Plantation) For The Year 2026-27
Basic Detail
Tender No RCD/GIRIDIH/1443/2026-27
Bidding Type Tender
Location
City Giridih
State Jharkhand
Key Dates
Publish Date 23 Nov 2026
Submission Date 21 Dec 2026
Open Date 22 Dec 2026
Finance
Tender Value 30.30 Crore
Tender Fee 10000
EMD 30.31 Lakhs
Exemption Not Available
Document List
BOQ_164155.xls
c352a9f9-2f22-4a91-913e-93fe6e9360d0.html
SBD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 23, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Dec 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 28 days
Dec 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 29 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_164155.xls

html

c352a9f9-2f22-4a91-913e-93fe6e9360d0.html

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender