Defence Statutory Bodies & Commissions/Committees Closing in 23 days TDR #58666774

Tender For Special Repairs To Fire Fighting Pipe Lines Fire Hydrants And Associated Fitting And Fixtures From Dnpm Office Junction To Ada Ground At Naval Station Karanja.

Issued by Statutory Bodies & Commissions/Committees · Raigad, Maharashtra
Tender Value
73.64 Lakhs
Estimated cost
Bid Submission
19 Dec 2026
23 days left
EMD
1.36 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Raigad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Fire Fighting Pipe Lines Fire Hydrants And Associated Fitting And Fixtures From Dnpm Office Junction To Ada Ground At Naval Station Karanja.

BOQ

Name of Work:- Special repairs to Fire fighting pipe lines fire hydrants and associated fitting and fixtures from DNPM office junction to ADA Ground at Naval Station Karanja.
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE KARANJA NAME OF WORK: Special repairs to Fire fighting pipe lines fire hydrants and associated fitting and fixtures from DNPM office junction to ADA Ground at Naval Station Karanja. CONTRACT AGREEMENT: CWE KJ(K)- OF 2026 - 2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words)
2Excavation in trenches n exc 1.5 m wide and not n exc 1.5 m depth and getting out in hard dense soil including grading and ramming bottom surface all as specified and directed by Engr-in-Charge for laying pipes and fittings.
3Returning , filling in including spreading, levelling , watering & well ramming in layers n.exc 25cm including making good disturbed surface to original levels complete all as specified.
4Removal of exacavation material to a distance n exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
5S&F in repair or replacement and testing and commissioning ductile iron pipe(DI Pipe) laying above the ground / below of ground in trenches of nominal diameter (DN) 100 mm, class K -9, with flanged at both the end including nut bolt and fitting required for connected to pipe complete all as specified and directed
6S&F in repair or replacement and commissioning of MS ERW pipe class 'B' in standard length conforming to IS 1239 part -I (ISI Marked) duly painted with two coats synthetic enamel paint of first quality over coat of primer for 150 mm bore all as specified and as directed.
7S&F in repair or replacement and commissioning of MS ERW pipe class 'B' in standard length conforming to IS 1239 part -I (ISI Marked) duly painted with two coats synthetic enamel paint of first quality over coat of primer for 100 mm bore all as specified and as directed.
8Supply, laying, jointing DI fittings (DI Specials) conforming to IS 9523 such as bends, caps, collars, Tees, Tail piece, Elbows, Tapers and Reducers etc complete all as per site requirement. Note:- The DI specials shall be of minimum class K-9 and from same manufacturer as of DI pipe.
9Supply & fix double door fire hose cabinate box with arrangement for holding 2 Nos 15m long hose pipe of size not less than 800mm x 600 mm x 250 mm, made out from 16 Gauge MS sheet duly painted with two coats of (red colour) synthetic enamel paint over a coat of red oxide zinc chrome primer with double leafed glazed shutters (glazed with 4 mm thick transparent fiber sheet) mounted over the MS angle iron 50mm x 50mmx 6mm frame having minimum 1m long, 4 Nos legs, and grouted the same into PCC (using1:3:6 type) and must have the legend \\" FIRE HOSE\\" painted prominently in the graphic style complete all as specified and directed.
10S&f in repair/replacement of pressure gauge 4\\" dia 0 to 14 Kgs rating in existing position complete all as specified and directed.
11S&F in repair/replacement of strainer for suction 150 mm more flanged type ISI marked complete all as specified and dirrected.
12S&F in repair/replacement of strainer for suction 100 mm more flanged type ISI marked complete all as specified and dirrected.
13S&F in reapir /replacement of channels/angles for foundations, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
14Supply and fix in repair sluice valve with flanged ends 150 mm borecast iron body, flanged and drilled end non rising type with nuts, as per IS 14846, ISI marked including all joints, class PN 1.6 complete all as specified and directed.
15Supply and fix in repair sluice valve with flanged ends 100 mm borecast iron body, flanged and drilled end non rising type , SS spindle with nuts, as per IS 14846, ISI marked including all joints, class PN 1.6 complete all as specified and directed.
16Supply and fix in repair sluice valve with flanged ends 80 mm borecast iron body, flanged and drilled end non rising type , SS spindle with nuts, as per IS 14846, ISI marked including all joints, class PN 1.6 complete all as specified and directed
17Supply and fix in repair fire hydrant landing valves gun metal, single outlet 63mm dia and suitable for fix to 80mm dia Flanged pipes as inlet including suitable size of gasket,nuts, bolts and washers for fixing the same including testing complete all as specified and as directed. Note:- The quoted rates shall be inclusive of complete accessories. including other jointing materials etc
18All as per Item no 16 above ditto but double headed
19M & L for construction of brick masonry valve pit of size 900 X900 X 900 mm (Internal dimensions) with brick work of sub class ‘B’ old size bricks built in cement mortar 1:4 and 10 mm thick rendering on internal and exposed external surfaces with and including 40 mm X 40 mm X 6 mm mild steel angle iron frame, 3.00 mm thick mild steel sheet cover with appropriate size lifting handles and locking arrangement and 01 No. 50 mm size 4 levers lock with keys in duplicate make – Navtal or Link including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer and demolition of existing old valve pit complete all as specified,
20Supply and fix in repair of Flanged stand post CI/DI of 80mm dia 1.5m height pipe 80 mm dia for stand post including necessary Gasket, suitable sizes nuts, bolts and washers etc for making complete fire hydrant stand post including all accessories including taking down existing fire hyfrants complete all as specified and directed.
21M&L for plain cement concrete PCC (1:2:4 ) type B1 , using 20mm graded stone aggregate used in trust block / pillars/ stand and formwork etc. complete all as specified and as directed.
22Supply and fixing fire hydrant hoze pipe length 15 mtr long suitable for fitting with standared size as per IS with fire hydrant post /pipe all as directd by Engr in charge..
23Supply and fixing open well Submersible pump set multistage with protection IP 68 ( pump and motor both) dry type with material of the pump casing and internal components influences durability and chemical resistance. making Common materials include stainless steel, cast iron, and bronze. impeller multistage bronze impeller used in this pump suitable for continuous operation with 'range of operation' maximum efficency 70 to 80 % of rated capacity for 440 V , 3 phase, 50 Hz AC supply 50 m Head. 1600 LPM discharge all as directed by Engr in charge
24Supply and fixing water proof Jockey pump openwell submersible pump Confirming to IS- 12469: 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nonover loading power characteristics for frequent start / stop operations for 440 V , 3 phase, 50 Hz 50 m head 180 LPM discharge all as directed by Engr in charge
25Supply, installation, commissioning and testing of LT Panel IP 55 for pump and motor of size 1x0.6 x0.60M (3 mm MS Sheet) factory made (CPRI approved), outdoor cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, outgoing cable chamber with same rated aluminium strip from cable chamber to MCCB output, made out of 3 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x50 x 6mm angle iron frame including painting to all internal & external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground but PCC foundation (1:2:4) type B1, suitable for 3 phase 4 wire system 415 volts grade consisting of Aluminium bus bar capacity of 250 Amps with necessary wiring with PVC sheathed stranded copper conductor of 1100 volts of appropriate length size with and including fixing lugs, bolts, screws etc complete including comprising of the following accessories:-INCOMING :-(a) MCCB, 160 Amp, 4 Pole,36 KA - 01 No. (b) Digital Combimeter and LED Display -01 No (c) Indicating lamp LED type one set in incoming phase. (d) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volt grade IS 694 maked of appropriate gauge including all copper lugs.OUTGOING:-(a) MCCB, 63 Amp, 3 Pole, 36 KA - 02 No. (b) MCB, 32 Amp, 4 Pole, 16 KA - 01 No.(c) Star delta starter complete with single phase preventer cap of starter 30 HP -01 Nos (d) Star delta starter complete with single phase preventer cap of starter 7.5 HP -01 Nos (e) Capacitor bank cap 30 Kvar (Notes : Make of panel, size and drawing shall be got approved from GE before placing order for procurement)
26M&L for 10 Sqmm, 3 core submersible copper conductor multistranded cable, LT 1100volt grade,water proof lowering with the column pipe into the bore/ well and testing complete after taking down old unserviceable cable, complete all as specified and directed
27Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 32X6mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete inclulding taking down existing unserviceable earthing all as specified and directed.Note:-Earth strip and protection pipe upto 7.5mtr is included in the rate quoted)
28M&L for 16 Sqmm, 3 core submersible copper conductor multistranded cable, LT 1100volt grade,water proof lowering with the column pipe into the bore/ well and testing complete after taking down old unserviceable cable, complete all as specified and directed.
29S&F in repair for fully Automatic Star-delta starter, AC 3 phase, 415 Volt, 50 Hz with sheet metal enclosure type suitable for 30 HP motor including making cable connections etc. complete all as sepcified and directed. Make L&T/Siemens/BCH
30S&F in repair for fully Automatic Star-delta starter, AC 3 phase, 415 Volt, 50 Hz with sheet metal enclosure type suitable for 7.5 HP motor including making connections, complete all as sepcified and directed. Make L&T/Siemens/BCH
31M&L for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, Outdoor type, of Suitable to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
32Location : In front of SWT at Mandir(A) INCOMING -(i) MCCB thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 400 Amps make Legrand or equivalent in M/s Schenider/M/s Siemens – 01 No.(B) OUTGOING-(ii) MCCB thermal & magnetic type 4 pole 415 volt 35 kA breaking cap. adjustable thermal release range 200 Amps make Legrand or equivalent in M/s Schenider/M/s Siemens – 02 No.(iii) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No(iv) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. MAKE AE/NSDA/PRINZ(v) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, Make TEKNIK/SELECT/L&T(vi) Aluminium bus bar of Rating 700 Amp R-Y-B phases and Neutral.(vii) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted.(vii) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted.(viii) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
33Supply & fixing, jointing, connecting & testing in trenches XLPE/PVC insulated PVC sheathed armoured cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of following sizes including taking out cable cover & cable all as specified and directed :
343.5 core 240 Sqmm
35Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in soft/loose soil including taking out faulty cable/cable, cable covers and GI pipe complete all as specified and directed.
36Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
37Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point.
38M & L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers all as specified
39Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed.
40M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 80 mm bore of pipe
41M & L for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations ,filling and mass concrete includings necessary form work complete all as specified & directed by Engr-in-charge.
42Earthing complete with GI earth plate electrode 60cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc made of GI & connected to Earthing test point and earth dolly all as shown in elect plate No 3 of SSR Pt-I incl all necessary earth work, excavation, PCC chamber, chamber cover with handle (PCC 1:2:4) including 40 mm dia protection pipe & 20 mm dia watering pipe and wire mesh funnel etc all as specified and as directed by Engr-in-charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58666774
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 73.64 Lakhs
LAST DATE 19-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repairs To Fire Fighting Pipe Lines Fire Hydrants And Associated Fitting And Fixtures From Dnpm Office Junction To Ada Ground At Naval Station Karanja.
Basic Detail
Tender No 84616-K/E8
Bidding Type Tender
Location
City Raigad
State Maharashtra
Key Dates
Publish Date 21 Nov 2026
Submission Date 19 Dec 2026
Open Date 21 Dec 2026
Finance
Tender Value 73.64 Lakhs
Tender Fee 1000
EMD 1.36 Lakhs
Exemption Not Available
Document List
0d79c515-869d-47c5-b94c-a9b197fe9f62.html
BOQ_897432.xls
soc6166.pdf
tender616.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Dec 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

0d79c515-869d-47c5-b94c-a9b197fe9f62.html

xls

BOQ_897432.xls

pdf

soc6166.pdf

pdf

tender616.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender