Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #58666771

Tender For Special Repairs To Building Nos. Pp-06 & Pp-08 (Or Married Accommodation) In Pp Lines And Additions/Alterations To Building No. Ml-01 (Officers Mess) In Ml Lines, Alwar Military Station.

Issued by Statutory Bodies & Commissions/Committees · Alwar, Rajasthan
Tender Value
38.92 Lakhs
Estimated cost
Bid Submission
14 Dec 2026
21 days left
EMD
78000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Alwar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Building Nos. Pp-06 & Pp-08 (Or Married Accommodation) In Pp Lines And Additions/Alterations To Building No. Ml-01 (Officers Mess) In Ml Lines, Alwar Military Station.

BOQ

Name of Work:- SPECIAL REPAIRS TO BUILDING NOS. PP-06 & PP-08 (OR MARRIED ACCOMMODATION) IN PP LINES AND ADDITIONS/ALTERATIONS TO BUILDING NO. ML-01 (OFFICERS MESS) IN ML LINES, ALWAR MILITARY STATION.
Sl. No. Item Description
1Demolition of brick or stone masonry built in cement mortar or cement-lime mortar, including quoins, arches, pillars, ashlar masonry, etc., and removal of demolished materials, complete, all as specified and directed by the Engineer-in-Charge.
2M&L brickwork with burnt clay fly ash building bricks conforming to IS 13757:1993 (old-size bricks), in straight or curved work on plan to a mean radius exceeding 6 m, built in cement mortar 1:6, complete, all as specified and directed.
3M&L brickwork with burnt clay fly ash building bricks conforming to IS 13757:1993 (old-size bricks), in half-brick thick walls, straight or curved on plan to any radius, built in cement mortar 1:4, complete, all as specified and directed.
4Demolition of unreinforced cement concrete in ground floors and paving, not exceeding 15 cm in thickness, below or above ground level, including removal of demolished materials, complete, all as specified and directed.
5Dismantling floor, hearth or wall tiling, including cement mortar bedding but excluding backing, carefully removing serviceable tiles and depositing them in store and removing rubbish off the premises, complete, all as specified and directed.
6M&L PCC 1:2:4, Type B-0, using 12.5 mm graded stone aggregate, 25 mm thick, as in flooring, complete, all as specified and directed by the Engineer-in-Charge.
7M&L non-skid ceramic tiles, 8–10 mm thick, square or rectangular, polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, in floors, set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tiles, over and including 15 mm thick screed bed in cement and sand mortar 1:6, complete, all as specified and directed.
8All as per preceding item, but on vertical surfaces such as skirting and dado, over and including 10 mm thick cement and sand plaster in mortar 1:4, complete, all as specified and directed by the Engineer-in-Charge.
9M&L coloured non-skid ceramic tiles, 300 x 300 x 7 mm thick, in floors, set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tiles, over and including 15 mm thick screed bed in cement mortar 1:6, make Somany/Johnson/Orient, complete, all as specified and directed by the Engineer-in-Charge.
10M&L coloured glazed ceramic tiles, 450 x 300 x 7 mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tiles, over and including 10 mm thick rendering in cement mortar 1:4, complete, all as specified and directed by the Engineer-in-Charge.
11Dismantling stone slabs or tiles of any description or thickness in floors, laid dry or laid dry and pointed, including removal of dismantled materials, complete, all as specified and directed.
12M&L machine-cut Kota stone slab flooring, 18–20 mm thick, size not less than 22 inches x 22 inches, laid and jointed with grey cement slurry mixed with pigment to match the shade of slabs, over and including 20 mm thick screed bed in cement mortar 1:6, including rubbing and mirror polishing, complete, all as specified and directed.
13M&L granite slabs, 18–20 mm thick, of approved shade, for cooking platforms, window sills and similar locations, machine-cut, bedded and jointed with grey cement slurry and pointed with white cement mixed with pigment to match the shade of granite, including cutting and polishing, laid over and including 20 mm thick screed bed in cement mortar 1:6, complete, all as specified and directed.
14Demolition of reinforced cement concrete roofs, floors other than ground floors, beams, staircases, landings, chajjas and similar suspended work, complete, all as specified and directed.
15M&L RCC, nominal mix, Type B-1 (1:2:4), using 20 mm graded stone aggregate, in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and similar work, complete, all as specified and directed.
16M&L TMT reinforcement bars, 10 mm dia and over, cut to length and bent to required shapes, including cranking, bending, spirally bending for hooping of columns, hooking ends and binding with annealed mild steel wire not less than 0.9 mm dia or securing with clips, complete, all as specified and directed.
17M&L 75 mm thick cement concrete 1:3:6, Type C-2, using 40 mm graded stone aggregate, as in plinth protection/pathways, finished even and smooth without using extra cement, complete, all as specified and directed.
18Taking down cement plaster or cement-lime plaster from PCC, stone or brick surfaces, including raking out joints, hacking for key and scrubbing down with water, complete, all as specified and directed.
19M&L rendering 10 mm thick in cement mortar 1:6 on brickwork, stone masonry or concrete surfaces, on fair faces of brickwork and other surfaces, finished even and smooth without using extra cement, complete, all as specified and directed.
20M&L rendering 15 mm thick in cement mortar 1:4 on brickwork, stone masonry or concrete wall surfaces, on fair faces of brickwork and other surfaces, finished even and smooth without using extra cement, including waterproofing compound and necessary scaffolding, ladders and formwork for work at heights up to 15 m, complete, all as specified and directed. Note: Waterproofing compound shall be measured and paid for separately under the respective item.
21M&L rendering 5 mm thick in cement mortar 1:3 on concrete ceiling surfaces, finished even and smooth without using extra cement, complete, all as specified and directed.
22M&L rough-cast plaster on external walls, applying an undercoat of cement and sand mortar 1:3, not less than 10 mm thick, and while still in plastic state, applying rough-cast mixture consisting of crushed stone or fine gravel aggregate of size 6–12 mm mixed with coarse sand and cement in the ratio of 1:1:1, finished even. The cement and sand mix shall be made slightly wetter than normal rendering to ensure that the larger aggregates are thoroughly covered, complete, all as specified and directed.
23M&L preparation of newly plastered surfaces and applying two coats of oil-bound distemper over 1 mm thick wall care putty to prepare the surface even and smooth, make Birla/JK/Nerolac, complete, all as specified and directed by the Engineer-in-Charge.
24M&L preparation of new surfaces and applying two coats of 100% premium acrylic exterior emulsion paint having VOC less than 50 g/litre, UV resistance as per IS 15489:2004, alkali and fungal resistance and dirt resistance, of required shade (company-depot tinted), with silicon additives at the rate of 1.43 litres per 10 sqm, over and including one priming coat of exterior primer applied at the rate of 0.90 litre per 10 sqm over 1 mm thick wall care putty, make Birla/JK/Nerolac, on prepared surfaces finished even and smooth for painting, complete, all as specified and directed.
25M&L preparation of newly plastered ceiling surfaces and applying three coats of whitewash, complete, all as specified and directed.
26M&L complete removal of existing treatment from stone or plastered wall surfaces, preparation of surfaces and applying two coats of 100% premium acrylic exterior emulsion paint having VOC less than 50 g/litre, UV resistance as per IS 15489:2004, alkali and fungal resistance and dirt resistance, of required shade (company-depot tinted), with silicon additives at the rate of 1.43 litres per 10 sqm, over and including one priming coat of exterior primer applied at the rate of 0.90 litre per 10 sqm over 1 mm thick wall care putty, on prepared surfaces finished even and smooth for painting, complete, all as specified and directed.
27M&L complete removal of existing treatment from old wall surfaces, including cornices, pilasters and other wall features, by washing and rubbing down, and applying two coats of oil-bound distemper over 1 mm thick wall care putty, make Birla/JK/Nerolac, complete, all as specified and directed.
28Demolition of existing mud treatment on roofs, of any thickness, including plaster, existing treatment and cleaning, whether the full thickness or only part thereof is removed, preparing the surface for further treatment and taking out and disposing of debris and rubbish to a distance exceeding 1 km but not exceeding 1.5 km, complete, all as specified and directed.
29M&L cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting and grouting with cement and sand slurry 1:3, complete, all as specified and directed.
30M&L PCC 1:2:4, Type B-0, using 12.5 mm graded crushed stone aggregate, as roof padding, laid to a minimum consolidated thickness of 25 mm as a levelling course and laid and compacted to the required slope over the roof, complete, all as specified and directed.
31M&L screed bed, 15 mm thick, in cement mortar 1:4, mixed with waterproofing compound and laid over green concrete surface, finished even and smooth without using extra lime or cement, complete, all as specified and directed. Note: Waterproofing compound shall be measured and paid for separately.
32M&L applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm, including cleaning of surfaces and application over bituminous primer, complete, all as specified and directed.
33M&L APP-based polymeric waterproofing membrane, minimum weight 3 kg/sqm and minimum thickness 3 mm, reinforced with polyester non-woven reinforcement/mat (centre core), including thermal insulation, laid by torch-application method with 100 mm overlaps on both longitudinal and transverse sides, as per manufacturer's instructions, reinforced with polyester non-woven fabric weighing not less than 150 g/sqm, laid on primed surface, including application of two coats of reflective silver aluminium paint over the APP membrane, complete, all as specified and directed.
34Supply only integral waterproofing compound, complete, all as specified and directed.
35Cutting openings through walls for doors, windows and other openings, or enlarging existing openings, etc., or cutting out defective masonry for underpinning, including providing, fixing and removing shoring, cleaning and stacking serviceable stones and removing surplus materials to store and rubbish off the premises, complete, all as specified and directed.
36M&L 50 mm thick sandstone slabs in sunshades, chajjas, shelves, sills, landings, cover stones, templates, etc., not exceeding 2 m in length, punched dressed on face and along exposed edges, self-faced on the other side and set and pointed in cement mortar 1:4, complete, all as specified and directed.
37Taking down chowkhats or frames, each not exceeding 1.5 sqm in area, complete, all as specified and directed.
38Taking down chowkhats or frames, each exceeding 1.5 sqm but not exceeding 4 sqm in area, complete, all as specified and directed.
39Taking down shutters of any description, each not exceeding 1 sqm in area, complete, all as specified and directed.
40S&F solid PVC door frame, size 50 x 47 mm, made out of 5 mm thick plain-coloured PVC sheet reinforced with MS square tube, complete, all as specified and directed.
41S&F 30 mm thick (stile thickness) factory-made solid-panel PVC door shutter consisting of a frame made out of mild steel tubes for top and bottom rails, the MS frame covered with heat-moulded plain-coloured PVC C-channel having a 20 mm wide PVC sheet strip stuck inside with solvent cement for stiles, and plain-coloured PVC sheets for top rail, lock rail and bottom rail on either side and as gap inserts for top and bottom rails; panelling of plain-coloured PVC sheet fitted in the MS frame, welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, as per specifications and drawings given in MES Schedule Part II (2010), complete, all as specified and directed.
42M&L mild steel angle iron door frames/chowkhats of Fe 410-O (Grade E-250), including 12 mm dia deformed bars for strengthening at the bottom of chowkhats, cutting the floor at the bottom to accommodate strengthening bars and making good the floor in PCC 1:2:4, Type B-0, to match the existing floor, complete, all as specified and directed by the Engineer-in-Charge.
43S&F 35 mm thick, second-class hardwood, factory-made, two-panelled door shutter with lock rail and panels of 9 mm thick BWP commercial plywood or 12 mm thick veneered particle board, with commercial veneering on both faces; sizes of rails and stiles as per IS 1003 (Part I), kiln-seasoned and chemically pressure-treated, and fixed to chowkhats, complete, all as specified and directed.
44S&F 35 mm thick, second-class hardwood glazed and skeleton shutters, open-rebated and prepared to receive glass, gauze, etc., without sash bars, with edges of framing plain, chamfered or rounded and fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24(a), supplied and fitted to chowkhats, complete, all as specified and directed.
45M&L preparation of new wooden surfaces over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete, all as specified and directed.
46S&F 100 mm long, medium-weight, cold-rolled mild steel butt hinges, complete, all as specified and directed.
47S&F 150 mm long aluminium anodised barrel tower bolts of extruded section, fixed complete, all as specified and directed.
48S&F 150 mm long aluminium cast handles, anodised finish, complete, all as specified and directed.
49S&F 300 mm long aluminium alloy anodised sliding door bolts, complete with hasp, staple (bolt type), fixing clips of sheet, cast or extruded sections, fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, fixed complete, all as specified and directed.
50S&F 300 mm long helical/rat-tail door spring with MS sheet wing pattern, including roller plate, complete, all as specified and directed.
51S&F 25 mm dia stainless steel drapery rods, in lengths as directed, of approved colour, including decorative finials at both ends and a pair of powder-coated stainless steel brackets, fixed at both ends to walls/beams with PVC rawl plugs and steel screws, in repair, complete, all as specified and directed.
52S&F stainless steel wire cloth having nominal wire diameter of 0.36 mm and average aperture width of 1.40 mm, fixed with stainless steel wire staples, complete, all as specified and directed.
53S&F anodised aluminium frames and other sections for doors, windows, ventilators and partitions, powder-coated in approved colour with minimum powder-coating thickness of 50 microns, having one or more rebates, including joining cleats for fixing, etc., complete, all as specified and directed.
54S&F anodised aluminium window and ventilator shutters, side-hung type without sash bars, using aluminium sections weighing 0.55 kg/m, powder-coated in approved colour with minimum powder-coating thickness of 50 microns, including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and anodised aluminium fittings comprising one 150 mm long peg stay, two 100 mm long Type B-21 hinges and one suitable handle, complete, all as specified and directed.
55S&F powder-coated anodised aluminium grills of approved pattern for windows, ventilators and doors, with minimum powder-coating thickness of 50 microns, complete, all as specified and directed.
56Supply only ordinary-quality sheet glass, 4.80 mm thick, in squares, each pane not exceeding 0.50 sqm, complete, all as specified and directed.
57Cutting holes in brick or stone walls, not exceeding half-brick thickness, built in cement mortar, for inserting holdfasts, and making good the dismantled portion in cement mortar 1:3 or PCC 1:2:4, Type B-1, as required, complete, all as specified and directed.
58S&F 4 mm mild steel wire in detached work, such as for mosquito nets, including fixing to straining bolts, hooks, eyes, etc., complete, all as specified and directed.
59M&L writing letters or figures in block, Roman, Italic or Indian lettering, not exceeding 30 cm in height, complete, all as specified and directed.
60Dismantling wall and ceiling boards of fibre, pulp, insulation, etc., or insulation boards, slabs and blankets of any thickness, including cover fillets, complete, all as specified and directed.
61M&L false ceiling with ArmGyp-FB ceiling tiles, size 595 x 595 mm, as approved by GE, fixed with and including galvanised iron powder-coated inverted T-section or L-section concealed GI framework suspended from ceiling with 4 mm dia galvanised iron suspension wires, wall-tapping screws, butterfly clips and hold-down clips for fixing the boards to the framework, complete as per manufacturer's instructions, all as specified and directed. Main tee size: 39 x 24.4 x 0.8 mm; wall angle size: 22.2 x 22.2 x 0.65 mm; grid size: 0.61 x 0.61 m.
62Dismantling boarding of any description, fixed in any position with nails, complete, all as specified and directed.
63S&F solid PVC wall lining comprising 5 mm thick decorative, coloured laminated PVC sheets, including solvent cement and fixing at site on PVC framework, as per specifications and drawings, complete, all as specified and directed.
64S&F 5 mm thick PVC sheet fillets, 35 mm wide, including fixing to walls to form PVC framework for wall panelling, as per specifications and drawings, complete, all as specified and directed.
65Dismantling framed timber scantlings, 40 sq cm and over in cross-sectional area, in any position, complete, all as specified and directed.
66M&L mild steel work in tubular trusses, tubular posts, purlins and rafters, including special-shaped washers, fabricated using butt-welded RHS/SHS sections conforming to IS 4923:1977, Grade E-250, Quality A, including distance pieces, cleats, brackets and all necessary connections, complete, all as specified and directed.
67Dismantling plain or corrugated steel sheeting of any gauge or thickness, including Nainital or similar-pattern roof coverings, complete, all as specified and directed.
68S&F 0.50 mm thick pre-painted galvanised steel/aluminium-zinc-coated corrugated roofing/cladding sheets, GI-based, green colour, having minimum tensile strength of 550 MPa, fixed to roof coverings or wall cladding with self-tapping screws and necessary fixing accessories, complete, all as specified and directed.
69S&F mild steel framework such as grills, gratings, angle frames, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, water-tank frameworks, cooler stands and similar work, with ends of bars shouldered and/or riveted or forged into spikes, conforming to Fe 290, Grade E-165, complete, all as specified and directed.
70M&L flat iron as in clamps, holdfasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wooden trusses or rafters, hooks and cleats welded to angle-iron door/window frames, etc., complete, all as specified and directed.
71M&L preparation of new steel surfaces of any description, over 10 cm in width or girth, and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete, all as specified and directed.
72M&L preparation of old painted steel and iron surfaces of any description, over 10 cm in width or girth, and applying one coat of synthetic enamel paint, complete, all as specified and directed.
73Dismantling existing kerb stones, including removal of cement bedding and disposal of dismantled materials/rubble, complete, all as specified and directed.
74M&L 75 mm thick PCC 1:4:8, Type D-2, using 40 mm graded stone aggregate, as sub-base to pathways/hardstanding, complete, all as specified and directed.
75M&L machine-pressed precast coloured cement concrete tiles, size 300 x 300 x 22–25 mm thick, made with grey cement and pigment, laid over and including 20 mm thick screed bed in cement mortar 1:6, as in floors, complete, all as specified and directed.
76M&L 60 mm thick machine-pressed precast coloured concrete interlocking paver blocks, made with grey cement and pigment, of approved shape and size, conforming to IS 15658:2006, Grade M-35, laid over 25 mm thick sand bed (sand measured and paid for separately), complete, all as specified and directed.
77M&L 25 mm thick sand filling under floors or in foundations, including watering and consolidation, complete, all as specified and directed by the Engineer-in-Charge.
78M&L providing and laying factory-made M-25 grade cement concrete kerb stones at or near ground level, placed in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including forming joints with or without grooves, the thickness of joints not exceeding 5 mm except at sharp curves, and providing drainage openings wherever required, complete, all as specified and directed by the Engineer-in-Charge.
79M&L preparation of new untreated concrete or plastered kerb-stone surfaces of any description, over 10 cm in girth or width, and applying two coats of synthetic enamel paint in black and white colours over one coat of primer, complete, all as specified and directed.
80Taking up or down 15 mm steel tubing and connections, complete, all as specified and directed by the Engineer-in-Charge.
81Taking up or down 20 mm steel tubing and connections, complete, all as specified and directed by the Engineer-in-Charge.
82Dismantling water storage tanks of capacity exceeding 250 litres but not exceeding 500 litres and removing the same from site, complete, all as specified and directed by the Engineer-in-Charge.
83S&F 15 mm bore medium-grade GI tubing with all fittings, fixed to walls and/or laid in floors, complete, all as specified and directed by the Engineer-in-Charge.
84S&F 20 mm bore medium-grade GI tubing with all fittings, fixed to walls and/or laid in floors, complete, all as specified and directed by the Engineer-in-Charge.
85S&F rotationally moulded polyethylene water storage tank, cylindrical vertical type with closed top, 500 litres capacity, hoisted and fixed in position, complete, all as specified in SSR Part I and as directed by the Engineer-in-Charge.
86S&F brass high-pressure ball valve with polyethylene float and fly nut, screwed for 15 mm dia iron pipe, in repair, complete, all as specified and directed by the Engineer-in-Charge.
87S&F 20 mm dia gunmetal globe or gate valve with iron wheel head, screwed at both ends for iron pipes and fixed, in repair, complete, all as specified and directed.
88S&F stainless steel plate rack, 1 mm thick, size 600 x 900 x 230 mm, for kitchen, make Prayag/Parryware/Neelkanth, including taking down old unserviceable plate rack, complete all as specified and directed.
89S&F stainless steel kitchen sink with drainage board, 1 mm thick, including plugs, washers and waste fittings, fixed with cast iron cantilever brackets and bedded in cement mortar on dwarf wall, connected to pipe through union, overall minimum size 915 x 460 mm with bowl size 410 x 330 x 160 mm, including 32 mm dia polyethylene low-density or high-density PVC waste pipe, 32 mm bore chromium-plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red-lead cement and other end fixed, making holes in walls for brackets and fixing in cement mortar 1:3 or PCC 1:2:4, Type B-0, including taking down old unserviceable sink, complete, all as specified and directed.
90S&F in repair 600 x 450 mm bevelled-edge mirror of selected-quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium-plated brass screws and cup washers, make Modiguard/Atul/Saint-Gobain, in repair, complete, all as specified and directed.
91S&F in repair white vitreous china wash-hand basin, flat-back type, size 550 x 400 mm, fixed on and including new chromium-plated brackets, waste coupling and PVC waste pipe, complete, all as specified and directed by the Engineer-in-Charge. Make: Cera/Hindware/Johnson.
92S&F in repair PVC connection pipe, 15 mm dia and 600 mm long, with adapter and washers at both ends, complete, all as specified and directed by the Engineer-in-Charge.
93S&F in repair chromium-plated dome-type grating, 100 mm dia, minimum weight 25 g, fixed with cement, complete, all as specified and directed.
94S&F in repair fancy-type bib tap, chromium-plated alloy, with cruciform or butterfly handle, screwed-down type, suitable for iron pipe or brass ferrule, 15 mm bore, complete, all as specified and directed by the Engineer-in-Charge.
95S&F in repair fancy-type stop/angle valve, chromium-plated alloy, screwed-down high-pressure type, screwed at both ends for iron pipe or unions, 15 mm dia, complete, all as specified and directed by the Engineer-in-Charge. Make: Prayag/Cera/Hindware.
96S&F in repair fancy-type stop valve, chromium-plated alloy, screwed-down high-pressure type, screwed at both ends for iron pipe or unions, 15 mm dia, long sunk concealed type, complete, all as specified and directed by the Engineer-in-Charge. Make: Prayag/Cera/Hindware.
97S&F in repair brass chromium-plated shower rose, 125 mm size, with swivel joint, including fixing to 15 mm bore steel pipe or union, complete, all as specified and directed.
98S&F white vitreous china squatting pan, Orissa pattern, size 580 x 440 mm, with integral footrests, connected to trap and flushing pipe, including making good the floor, complete, all as specified and directed by the Engineer-in-Charge. Make: Parryware/Hindware/Cera.
99S&F in repair PVC low-level flushing cistern, 10 litres capacity, white, ISI marked, with inlet ball valve, float and handle, syphonic-action type, including brackets and 32 mm dia polyethylene low-density or high-density PVC flush pipe, fixed in repair, complete, all as specified and directed. Make: Dolphin/Commander/Champion.
100S&F in repair health faucet with ABS body, mild-steel chromium-plated fittings, suitable for 15 mm dia pipe, with 1.25 m long flexible tube and ABS wall hook, including making connections and fixing in position, complete, all as specified and directed.
101S&F in repair PTMT towel rail, 600 mm long, fixed with and including chromium-plated brass screws and wooden/plastic cleats, minimum weight 190 g, complete, all as specified and directed by the Engineer-in-Charge. Make: Prayag/Cera/Hindware.
102S&F in repair 15 mm dia fancy-type CP pillar tap, cast copper alloy, chromium-plated, with capstan head, screwed-down high-pressure type, with or without lettering 'HOT' or 'COLD', with long screwed shank and fly nuts, screwed for iron pipe and fixed, complete, all as specified and directed by the Engineer-in-Charge.
103Dismantling 75/110 mm bore PVC (SWR) drain pipes, along with fittings and accessories, jointed in cement mortar, and taking out from walls, floors or trenches, wherever required, complete, all as specified and directed.
104S&F PVC (SWR) pipes, 110 mm bore, single-socketed, in any length, with rubber-ring joints, fixed to walls, complete, all as specified and directed.
105S&F PVC (SWR) pipes, 110 mm bore, single-socketed, in any length, with rubber-ring joints, laid in trenches or floors, complete, all as specified and directed by the Engineer-in-Charge.
106S&F PVC (SWR) pipes, 75 mm bore, single-socketed, in any length, with rubber-ring joints, fixed to walls, complete, all as specified and directed by the Engineer-in-Charge.
107S&F PVC in repair (SWR) bends, any radius, 110 mm bore, complete, all as specified and directed by the Engineer-in-Charge.
108S&F in repair PVC (SWR) vent cowl, 110 mm dia, complete, all as specified and directed by the Engineer-in-Charge.
109S&F in repair PVC (SWR) floor trap, 75 mm dia, plain type, with grating, including jointing with solvent cement, complete, all as specified and directed by the Engineer-in-Charge.
110S&F in repair PVC (SWR) gully trap, 125/110 mm, including setting and jointing with solvent cement, complete, all as specified and directed by the Engineer-in-Charge.
111S&F in repair PVC (SWR) 110 mm dia single junction (single T), equal or unequal, complete, all as specified and directed by the Engineer-in-Charge.
112M&L concrete bed to drain pipes, including packing underneath and haunching against the sides of pipes after laying and testing, in cement concrete 1:3:6, Type C-2, using 40 mm graded crushed stone aggregate, for 150 mm dia pipe, complete, all as specified and directed.
113Taking down copper/aluminium point wiring (light, fan, socket or power), complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, etc., removing materials for safe custody or for taking credit (credit for above items shall be made as per separate conditions) and making good disturbed surfaces of walls, floors, etc., complete, all as specified and directed.
114M&L for surface point wiring for One light/fan point controlled by one switch, 1100 Volts grade, 1.5 sqmm PVC-insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS 694:1990, ISI marked, including concealed PVC conduit of suitable size with all accessories in walls/ceilings/floors/roofs, etc., sunk pressed-steel or cast-iron terminal boxes with 3 mm thick plastic-laminated sheet top cover, including 1.5 sqmm PVC-insulated FRLS unsheathed 1100 Volts grade multistranded copper conductor conforming to IS 694:1990, ISI marked, as continuous earth wire connected to common earth dolly, complete, all as specified and directed.
115All as per precedeing item but for One light point controlled by two-way switches.
116All as per precedeing item but for One 3-pin 5 Amp socket outlet on an independent board.
117All as per precedeing item but for One 3-pin 5 Amp socket outlet, 5 Amps, on the same board.
118All as per precedeing item but for One bell/buzzer point controlled by one push button, independent, with cables 1.5 sqmm size, complete all as specified and directed.
119All as per precedeing item but with cables 2.5 sqmm size, complete all as specified and directed.
120M&L for point wiring complete for one 15 Amp socket outlet on an independent board, with FRLS PVC-insulated and unsheathed cable, 2.5 sqmm nominal area, multistranded copper conductor, single core, conforming to IS 694, including concealed PVC conduit of suitable size, pressed-steel terminal boxes not less than 2 mm thick of required size (factory made), including painting terminal boxes inside and outside with two coats of synthetic enamel paint over one coat of red oxide primer and with top cover 3 mm thick plastic-laminated sheet of required colour, complete with all accessories, including FRLS PVC-insulated and unsheathed cable 2.5 sqmm nominal area, multistranded copper conductor, single core conforming to IS 694, green colour as earth wire to common earth and connected to earth dolly, drawn in same concealed conduit and controlled by one 15 Amp switch, complete, all as specified and directed.
121M&L for point wiring complete for one 15 Amp socket outlet on an independent board, with FRLS PVC-insulated and unsheathed cable, 4 sqmm nominal area, multistranded copper conductor, single core, conforming to IS 694, including concealed PVC conduit of suitable size, pressed-steel terminal boxes not less than 2 mm thick of required size (factory made), including painting terminal boxes inside and outside with two coats of synthetic enamel paint over one coat of red oxide primer and with top cover 3 mm thick plastic-laminated sheet of required colour, complete with all accessories, including FRLS PVC-insulated and unsheathed cable 4 sqmm nominal area, multistranded copper conductor, single core conforming to IS 694, green colour as earth wire to common earth and connected to earth dolly, drawn in same concealed conduit and controlled by one 15 Amp switch, complete, all as specified and directed.
122S&F stepped-type electronic fan regulator, flush type, on the existing phenolic-laminated sheet, etc., ISI marked, complete, all as specified and directed.
123M&L in repair for submain wiring with 4 runs of 6 sqmm single-core copper conductor PVC-insulated cable and 1 run of 6 sqmm single-core copper conductor insulated cable as earthing lead, drawn through PVC conduit, complete, all as directed. Note: Four runs of 6 sqmm cable and one run of 6 sqmm earthing cable together shall be measured as one unit length.
124Supply and fix in repairs Piano 6 Amp, one-way flush-type switch, make ISI marked, complete, all as specified and directed.
125Supply and fix in repairs Piano 5 Amp, two-way flush-type switch, make ISI marked, complete, all as specified and directed.
126Supply and fix in repairs 6 Amp socket, ISI marked, complete, all as specified and directed.
127Supply and fix in repairs switch-socket combination outlet, 3-pin, 6/16 Amps, flush-type multipurpose, with fuse and neon indicator, make ISI marked, complete, all as specified and directed.
128Supply and fix in repairs ceiling rose, surface bakelite, size 65 x 50 mm, three-terminal type, complete, all as specified and directed.
129Supply and fix in repairs LED tube light along with fixture, 1 x 22 Watt, AC decorative-box type, with driver and holder, including LED tube light and connection with three-core flexible copper conductor cable of suitable size from ceiling rose, complete, all as specified and directed.
130Supply and fix in repairs LED 10 Watt mirror-type, high-output diffuser, 2 feet luminaire, complete, all as specified and directed.
131S&F in repairs LED luminaire, 600 x 600 mm, 35/36 Watt, 220 V AC, recessed type, with high-efficiency PMMA diffuser, driver, holders and LED lamp, suitable for roof ceiling, including connection with driver through three-core flexible copper conductor cable, complete, all as specified and directed.
132M&L in repairs lamp holder, PVC/polycarbonate type with cord-grip cap suitable for pendant fittings, ISI marked, complete, all as specified and directed.
133M&L for rewinding ceiling fan, 1200/1400 mm sweep, with super-enamelled copper wire of existing gauge, including insulation material, varnishing and drying, complete, all as directed.
134S&F in repairs MCB DB, TPN, 8-way, double-door type, 415 Volts, complete, all as specified and directed.
135S&F in repairs MCB DB, SPN, 8-way, double-door type, 240 Volts, with 200 Amp rated busbar, complete, all as specified and directed.
136Supply and fix in repairs MCB, TPN, 100 Amp, 415 Volts, single phase, 10 kA capacity, complete, all as specified and directed.
137Supply and fix in repairs MCB, SPN, 40 Amp, 230 Volts, single phase, 10 kA capacity, complete, all as specified and directed.
138Supply and fix in repairs MCB, SP, 6 to 40 Amp, 230 Volts, single phase, 10 kA capacity, complete, all as specified and directed.
139S&F in repairs single-pole and neutral enclosure with a two-pin and earth plug and socket, complete with one double-pole MCB, 240 Volts, 20 Amps, complete, all as specified and directed.
140S&F in repairs multi-music type bell, AC 230 Volts, single-pole, complete, all as specified and directed.
141M&L for earthing (including taking down old existing earthing ) complete with galvanised steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to galvanised iron wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts and washers of galvanised iron or steel, besides welding at all joints as shown in drawings and including excavation and earthwork, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and including earth test point of galvanised iron/steel of size 75 x 75 x 25 mm, supplying and laying charcoal dust, common salt, PCC 1:2:4, Type B-1 chamber and MS angle-iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick in PCC 1:2:4, Type B-1, using 20 mm graded stone aggregate reinforced with 6 mm dia round bars at 75 mm centres both ways with MS handle 12 mm dia, GI funnel and wire mesh, 20 mm dia GI pipe light grade for watering, all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point, including testing, complete, all as specified and directed.
142S&F in repairs decorative wall light, gold-finish fixture with cognac-hammered glass diffuser, suitable for 7.5/9 Watt LED filament lamp, including 9 Watt LED lamp, complete, all as specified and directed.
143M&L in repair wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC-insulated copper conductor, single-core cable in surface/recessed as required in PVC casing/capping/concealed conduit: 2 x 10.0 sqmm + 1 x 6.0 sqmm earth wire, complete, all as specified and directed.
144M&L in repair switch-socket combination 2-in-1, 3-pin, 5 and 15 Amp, flush-type universal, make ISI marked, complete, all as specified and directed.
145M&L in repair bell push, flush type, 5 Amp, make ISI marked, complete, all as specified and directed.
146M&L in repair buzzer, Ding-Dong AC 230 Volts, single-pole, make ISI marked, complete, all as specified and directed.
147M&L in repair LED bulb, 9 Watt, make and model Havells or equivalent of Bajaj, Syska, Surya, Philips, ISI marked, complete, all as specified and directed.
148M&L in repair ceiling rose, 3-phase/PVC/polycarbonate, isolated body, complete, all as specified and directed.
149Taking down and fixing only ceiling fans, complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, all as specified and directed.
150Supply and fix in repair double-door, triple-pole and neutral, 6-way, ISI marked, complete, all as specified and directed.
151Supply and fixing in repair 415V, 10 kA, 'C' curve miniature circuit breaker (MCB) of TPN, 40 to 100 Amp poles and current-carrying capacity in the DB, complete with connection, testing and commissioning, all as specified and directed.
152Supply and fixing in repair 240V, 10 kA, 'C' curve miniature circuit breaker (MCB) of SPN, 40 to 63 Amp, and current-carrying capacity in the MCB DB, complete with connection, testing and commissioning, all as specified and directed.
153Supply and fixing 240V, 10 kA, 'C' curve miniature circuit breaker (MCB) of SPN, 32 Amp, and current-carrying capacity in the MCB DB, complete with connection, testing and commissioning, all as specified and directed.
154Supply and fixing in repairs 240V, 10 kA, 'C' curve miniature circuit breaker (MCB) of SP, 5 to 32 Amp, and current-carrying capacity in the MCB DB, complete with connection, testing and commissioning, all as specified and directed.
155Supply, laying and testing cable XLPE-insulated, screened, PVC-bedded, galvanised steel strip or wire-armoured electric power cables (heavy duty), 1100 Volts grade, with stranded aluminium conductor of size 35 sqmm, 3.5 core including taking down old existing cable complete, all as specified and directed.
156Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5 m in depth for laying of cables and foundations of poles/stay assemblies and getting out the excavated material in any type of soil, complete, all as specified and directed.
157Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete, all as specified and directed.
158Removing surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete, all as specified and directed.
159M&L for sand cushioning to PVC underground cable with screened and washed sand and punning to provide the required cover, complete, all as specified and directed. Note: Thickness after punning shall be considered for payment.
160M&L for brickwork with fly ash bricks (as per IS 13757:1993 burnt clay fly ash building bricks), old-size bricks, with width equal to the length of the brick, laid dry and flat, butted against each other with gaps between adjacent bricks not exceeding 10 mm over underground cable for protection, including taking down old unserviceable bricks, complete, all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58666771
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 38.92 Lakhs
LAST DATE 14-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repairs To Building Nos. Pp-06 & Pp-08 (Or Married Accommodation) In Pp Lines And Additions/Alterations To Building No. Ml-01 (Officers Mess) In Ml Lines, Alwar Military Station.
Basic Detail
Tender No 8611/E8
Bidding Type Tender
Location
City Alwar
State Rajasthan
Key Dates
Publish Date 21 Nov 2026
Submission Date 14 Dec 2026
Open Date 16 Dec 2026
Finance
Tender Value 38.92 Lakhs
Tender Fee 500
EMD 78000
Exemption Available
Document List
130903c8-f754-4c75-a6b2-f75a839e395c.html
BOQ_897471.xls
Tender8611.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Dec 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

130903c8-f754-4c75-a6b2-f75a839e395c.html

xls

BOQ_897471.xls

pdf

Tender8611.pdf

pdf

Tendernotice_1.pdf

Disclaimer