Housing Urban and Rular Development Local Bodies Closing in 22 days TDR #58665196

Tender For Construction Of Treated Sewage Pumping Station For 56 Mld Stp Govindpuram, Ghaziabad

Issued by Local Bodies · Ghaziabad, Uttar Pradesh
Tender Value
2.62 Crore
Estimated cost
Bid Submission
18 Dec 2026
22 days left
EMD
5.24 Lakhs
Bank guarantee accepted
Document Fee
13098
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ghaziabad → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Treated Sewage Pumping Station For 56 Mld Stp Govindpuram, Ghaziabad

BOQ

Name of Work:- Construction of Treated Sewage Pumping Station for 56 MLD STP Govindpuram, Ghaziabad
Sl. No. Item Description
1Earthwork in excavation by mechanical mens (Hydraulic excavator)/ manual means over areas(exceeding 30cm in depth, 1.5m width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed by engineer-in-charge).(DSR2023/2.6.1)(177.50X0.762=135.26+3%=139.31)
2Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (DSR Item No.4.1.8)(6812.00X0.762=5190.74+3%=5346.47)
3Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads but e[cluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note E[tra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mi[ is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All works upto plinth level Concrete of M30 grade with minimum cement content of 350 kg /cum(DSR 2023/5.33.1.2)(9655.70 x 0.762= 7357.64+3%=7578.37)
4Same as above in Item No.3 but for above plinth Level (DSR 2023/5.33.2.2)(10011.35 x 0.762= 7628.65+3%=7857.51)
5Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level for Thermo-Mechanically Treated bars. Fe-500 D (DSR Item No.5.22.6/2023)(107.85X0.762=82.18+3%=84.65)
6Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth 1:6 cement & C. sand mortar (DSR Item No.6.1.2)(7132.25X0.762=5434.77+3%=5597.82)
7Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in Super Structurein 1:6 cement & C. sand mortar (DSR Item No.6.4.2)(9105.95X0.762=6938.73+3%=7146.90)
812mm thick plaster of mix 1:4 cement and coarse sand mortor (DSR Item No.13.4.1/2023)(357.35x0.762=272.30+3%=280.47)
952 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding thecost of nosing of steps etc. complete.(DSR Item No.13.4/2023)(978.45x0.762=745.58+3%=767.95)
10Finishing with Epoxy paint (two or more coats) at all locations prepared andapplied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work (DSR Item No.13.52.2/2023)(235.15x0.762=179.18+3%=184.56)
116 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge(DSR Item No.13.86/2023)(269.15x0.762=205.09+3%=211.25)
12Wall painting with two coats of acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.(DSR Item No.13.82.2/2023)(137.45x0.762=104.74+3%=107.88)
13Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)(DSR Item No.13.44.1/2023)(1116.90x0.762=89.08+3%=91.75)
14Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer (DSR Item No.13.41.1/2023)(185.65x0.762=141.47+3%=145.71)
15Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. (DSR Item No.5.9.1 /2023)(392.15x0.762=298.82+3%=307.78)
16Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.(DSR Item No.5.9.2 /2023)(842.50x0.762=641.99+3%=661.24)
17Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform(DSR Item No.5.9.3 /2023)(927.25x0.762=706.56+3%=727.76)
18Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR Item No.5.9.5 /2023)(736.40x0.762=561.14+3%=577.97)
19Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls Under 20 cm wide (DSR Item No.5.9.16.1 /2023)(208.55x0.762=158.92+3%=163.68)
20Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mmnominal size)(DSR Item No.4.1.3 /2023)(7878.500x0.762=6003.42+3%=6183.52)
21Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete(DSR Item No.10.1 /2023)(117.35x0.762=89.42+3%=92.10)
22Providing and fixing 30 mm thick factory made laminated veneer lumber glazed shutter conforming to IS: 14616 and TADS 15:2001 (Part B), using 4 mm thick float glass panes for doors, windows and clerestory windows fixing with bscrews, all as per directions of Engineer-in-charge (Note:- Butt hinges and necessaryutt hinges of required size with necessary screws shall be paid separately) (DSR Item No.9.10.1 /2023)(3066.20x0.762=2336.44+3%=2406.54)
23Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications,drawings and direction of Engineer-in-charge complete.(DSR Item No.21.1 /2023)4997.7x0.762=3808.25+3%=3922.49)
24Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar(DSR Item No.15.7.4 /2023)(2060.20x0.762=1569.87+3%=1616.97)
25Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer - in- charge.(DSR Item No.15.3 /2023)(3551.25x0.762=2706.05+3%=2787.23)
26Dismantling of 1000 dia R.C.C. hume pipe for sewer with due care so as to avoid damages to the sewersincluding stacking of useful materials near the site with in a distance of 50 meters and laid and disposal of un-serviceable materials (analysed)
27Providing and laying 1000mm dia Non Pressure NP-3 class (Medium duty) R.C.C.pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete(DSR Item No.19.35.4)(66565.55X0.762=5072.29+3%=5524.46)
2810 cm thick (average) mud phaska of damped brick earth on roofs laid to slope 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat:With common burnt clay F.P.S.(non modular) brick tile of class designation 10 (DSR Item no.12.16.1/2023)(1050.2X0.762=800.25+3%=824.26)
29Construction of granular sub-base (G.S.B.)of app. Quality including supply of all material.labour and T & P etc. required for proper completion of work (A.R.)
30Providing and laying factory made chamfered edge 60mm thick Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineer in-Charge. (DSR Item No.16.91.1)(1045.65X0.762=796.79+3%=820.69)
31Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.(DSR Item No.12.22)(298.25X0.762=227.27+3%=234.08)
32Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .(DSR Item No.13.62.1/2023)(226.25X0.762=172.40+3%=177.57)
33Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(DSR Item No.1.3.3/2025)(2101.00X0.838=1760.64)
34Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.(DSR Item No.1.55.3/2025)(994.00X0.838=832.97)
35Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.(DSR Item NO.1.32/2025) (659.00X0.838=552.34)
36Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (DSR Item No.1.56/2025)(757.00X0.838=634.37)
37Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit for 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire For 6A Point(DSR Item No.1.7.1/2025) (370.00X0.838=310.06)
38Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit for 2 X 4 sq. mm + 1 X 4 sq. mm earth wire For 16A Power Circuit Point (DSR Item No.1.7.3/2025)(476.00X0.838=398.89)
39Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25/32 A modular socket outlet and 25/32 A modular SP MCB, “C” curve including connections, painting etc. as required(DSR Item No.1.57/2025)(807.00X0.838=676.27).
40Providin & Fixing 250A capacity 35KA TP MCCBwit termomanetic realse and terminal spreadersin existingcubical panelboard includingdrilling oles in cubical panel, makin connection Ics=100% Icu andOperational Voltae 690Vetc. required (DSR(E & M) Item no.2.2.7/2025)(14584 x 0.838=12221.39)
41Recovery of old bricks avilable from dismanteling of brick work (UP PWD SOR Item No.1(a)/2025
42Recovery of 40mm size bricks ballst avilable from dismanteling of brick work(DSR Item No.0287/2025)(700+5%=735)
43Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.(DSR Item No. 5.30/2023)(78.4x0.762=59.74+3%=61.53)
44Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (DSR Item No.4.17 /2023)(749.30x0.762=570.96+3%=588.09)
45Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design:12.21.1 In 75x75 mm deep chajja case (DSR Item No.12.21.1/2023)(305.15x0.762=232.52+3%=239.5)
46Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost).with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR Item No.10.10.1/2023)(82.45x0.762=62.83+3%=64.71)
47Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design (DSR Item No.19.16/2023)(553.70.762=421.91+3%=434.58)
48Providing and fixing 110 mm diameter metre on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.(DSR Item No.12.41.2/2023)(377.40x0.762=287.58+3%=296.21)
49Providing and fixing 110mm dia PVC moulded coupler on wall face for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion.(DSR Item No.12.42.1.2/2023)(136.15x0.762=103.75+3%=106.86)
50Providing and fixing 110mm dia PVC moulded Sinle TEE wit door on wall face for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion.(DSR Item No.12.42.3.2/2023)(234.15x0.762=178.42+3%=183.77)
51Providing and fixing 110mm dia PVC moulded Bend on wall face for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion.(DSR Item No.12.42.5.2/2023)(150.35x0.762=114.57+3%=118.00)
52Providing and fixing 110mm dia PVC moulded Shoe (Plain) on wall face for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion.(DSR Item No.12.42.6.2/2023)(131.85x0.762=100.47+3%=103.48)
53Providing and fixing to the inlet mouth of rainwater pipe cast iron grating, 15 cm diameter, weighing not less than 440 grams.(DSR Item No.12.44/2023)(54.70x0.762=41.68+3%=42.93)
54Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5(DSR Item No.18.35.1/2023)(26163.40x0.762=19936.51+3%=20534.29)
55Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5(DSR Item No.19.27.1/2023)(5957.9x0.762=4359.92+3%=4676.12)
56Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre open length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 4.2m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)(DSR Item No.16.53/2023)(375.8x0.762=286.36+3%=294.95)
57Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete of 125x64x1.90 mm size(DSR Item No. 9.70.1/2023)(118.2x0.762=90.07+3%=92.77)
58Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) 250x10 mm size(DSR Item No. 9.63.1/2023)(83.9x0.762=63.93+3%=65.85)
59Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(DSR Item No. 9.76/2023)(83.9x0.762=651.24+3%=670.78)
60Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. 125mm(DSR Item No. 9.100.1/2023)(66.25x0.762=50.48+3%=52.00)
61Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin Rubber Stopper(DSR Item No. 9.101.2/2023)(72.35x0.762=55.13+3%=56.78)
62Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works(DSR Item No.10.25.2/2025)(172.60X0.762=131.52 +3%=135.47)
63Providing , laying , Testing and commissioning of C class eavy duty 250mm (wall Tikness 6.3mm) dia M.S. pipe confimin to IS 1239/class-II of IS: 3589 including Welding , Fittings like Elbow, Tees, Flanges, Tapers, Nuts, Bolts, gaskets etc. and fixing te pipe on wall/ceiling wit suitable clamp/support frame and painting wit two coats of syntetic enamel paint of required sade complete as required (DSR(E & M) Item no.27.7.10/2025)(8023.00 x 0.838=6723.27)
64Providing , laying , Testing and commissioning of C class eavy duty 600mm (wall Tikness 6.3mm) dia M.S. pipe confimin to IS 1239/class-II of IS: 3589 including Welding , Fittings like Elbow, Tees, Flanges, Tapers, Nuts, Bolts, gaskets etc. and fixing te pipe on wall/ceiling wit suitable clamp/support frame and painting wit two coats of syntetic enamel paint of required sade complete as required (M.R.)
65Supply and Fixing of 1170 cum per Hour capacity and 12.00m Head Transfer Seweage Pump of app. Quality incliding supply of all material, labour and T & P etc. required for proper completion of work. (M.R.)
66Providing and fixing 600mm dia Electrical sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately.(M.R.)
67Providing and fixing 250mm dia class -II C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately.(DSR Item no.18.31.5.2/2023)(24623.50X0.762=18763.11+3%=19326.00)
68Providing , laying , Testing and commissioning of Non- Return Valve of 250mm dia confirming to IS:5312 complete wit rubber asket, I. bolts, nuts, waser as required DSR(E & M) Item no.27.14.9/2025)(47622.00 x 0.838=39,907.24)
69Providing and fixing 600mm dia size Flow meter of approved quality including supply of all material, labour and t&P etc. required for proper completion of work.(M.R.)
70Providing and fixing ultrasonic level transmeter of approved quality includin supply of all material, labour and t&P etc. required for proper completion of work.(M.R.)
71Supply,Intallation, Testing and commissioning of hybrid APFC Panel 3 phase 4 wire 415 V 50 hz AC system forAbmient temperture -5 degree to +40 degree C of 900 KVAR capacity wit passive solution (DSR(E & M) Item no.4658/2025)(3113500.00 x 0.838=26,09,113.00)
72Providing and fixing Electrical hoist of 3 Tonn Capacity and approved quality includin supply of all material, labour and t&P etc. required for proper completion of work.(M.R.)
73Providing and fixing of pressure transmitter of approved quality includin supply of all material, labour and t&P etc. required for proper completion of work.(M.R.)
74Providing and fixing 25mm x 5mm G.I. Strip on surface or on recess for connection as required for proper completion of work.(DSR(E & M) Item no.5.15/2025)(287.00 x 0.838=240.51)
75Erection and Instalation of Seawage Pump includin Supply of all material, Labour , T & P etc. required for proper completion of work. (M.R.)
76Providing & Applying weather proof sealant on outer joints of approved make confirming to IS & directed by Engineer-incharge Sealant 25mmx10mm at joints(DSR Item no.26.78.1/2023)(178.95X0.762=136.36+3%=140.45)
77Supply and Fixin of 40 Watt LED Batten lit of powder coated die cast/extruded aluminium body 9Tickness more tan1.20mm (DSR(E & M) Item no.8.11.4/2025)(837.00 x 0.838=701.41)
78Supply , lintallation , Testing and commissioning of 1200mm service valuv more tan6cm/minute size ceilin Fan wit brusless direct current (BLDC) motor DSR(E & M) Item no.9.2.3/2025)(2695.00 x 0.838=2258.41)
79Providing and Fixing 50W Semi Integrated Solar Street LightSystem Specifications: - Led Wattage: 50WCharge Controller: 10amp MPPT ChargeCharge Controller: 10amp MPPT ChargeController Battery: 12.8V/36Ah Lifepo4Solar Panel: 120Wp Charging time:7hrsLight backup: 2 days 6 mtr pole, Module Structure, Light arm nut bolt and complete accessories. (M.R.)
80Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. (DSR(E & M) Item no.5.6/2025)(15004.00 x 0.838=12573.35)
81Supply and Fixing of 250mm blade sweep eavy duty Exaust Fan of app. Quality (M.R.)
82Providing and supplying hand-operated Chain Pulley Block of 3-ton capacity with 3-metre standard lift, conforming to IS 3832, complete as required. Make Ferrotech or equivalent (M.R.)
83POWER CABLE FOR PUMP (25SQMM 3 Core)Providing, laying, testing and commissioning of 1.1 kV grade, 3-core, 25 sq.mm copper/aluminium conductor power cable, XLPE/PVC insulated and sheathed, suitable for pump power supply, laid through cable trays, trenches, conduits or other approved routes, including dressing, clamping, identification, and all necessary accessories, complete as per specifications and directions of the Engineer-in-Charge. (M.R.)
84CONTROL CABLE FOR PMU (10X1.5 SQMM)Providing, laying, testing and commissioning of 1.1 kV grade, 10-core, 1.5 sq.mm control cable, copper conductor, PVC insulated and sheathed, suitable for PMU control and monitoring circuits, including laying, dressing, tagging, clamping, termination and all necessary accessories, complete as per specifications and directions of the Engineer-in-Charge. (M.R.)
85JUNCTION BOX 450 X 600Providing and installing suitable weatherproof junction box of approved material and size, complete with terminal blocks, cable entry glands, internal wiring connections, mounting accessories and necessary hardware, including fixing, connection and testing, complete as per specifications and directions of the Engineer-in-Charge. (M.R.)
86Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 3 X 300 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (DSR(E & M) Item no.11.2.16/2025)(3028.00 x 0.838=2537.46)
87Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 2 X 25 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. DSR(E & M) Item no.11.2.2/2025)(1582.00 x 0.838=1325.72)
88THIMBALS Providing and fixing suitable cable-end thimbles/ferrules of the required size for control and electrical wiring, including crimping, wire identification and all necessary accessories, complete as per specifications and directions of the Engineer-in-Charge. (M.R.)
89Supplying and installaton 300 mm width X 50 mm depth X 1.6 mm thickness size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. (DSR(E & M) Item no.4.1.4/2025)(866.00 x 0.838=725.71) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58665196
AUTHORITY Local Bodies
TENDER VALUE 2.62 Crore
LAST DATE 18-12-2026
Authority
Authority Name Ghaziabad Development Authority
Work Description Tender for Construction Of Treated Sewage Pumping Station For 56 Mld Stp Govindpuram, Ghaziabad
Basic Detail
Tender No 703/4/PA-T/2026-27 Dt. 20.11.2026 (S.no-7)
Bidding Type Tender
Location
City Ghaziabad
State Uttar Pradesh
Key Dates
Publish Date 21 Nov 2026
Submission Date 18 Dec 2026
Open Date 21 Dec 2026
Finance
Tender Value 2.62 Crore
Tender Fee 13098
EMD 5.24 Lakhs
Exemption Not Available
Document List
703_7.pdf
BOQ_2301536.xls
d918e56c-5623-4663-8adc-ab2df00fc2ba.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Dec 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
pdf

703_7.pdf

xls

BOQ_2301536.xls

html

d918e56c-5623-4663-8adc-ab2df00fc2ba.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender