Tender For Installation Of Solar Drinking Water System At Medical Collage Group D And E Block X (132868918)
Tender Value
3.49 Lakhs
Estimated cost
Bid Submission
28 Nov 2026
0 days left
EMD
7000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Darjeeling → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Installation Of Solar Drinking Water System At Medical Collage Group D And E Block X (132868918)
BOQ
| Sl. No. | Item Description |
| 1 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes,scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the samecomplete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia. (ii) 100 mm dia. boring etc. top enlargement |
| 2 | Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). i) 100 mm dia PVC (ASTMD) |
| 3 | ii) 32 mm dia PVC (ASTMD) |
| 4 | iii) 25 mm dia PVC (ASTMD) |
| 5 | Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. iv) 100 mm dia. i) 100 mm dia PVC Stainer |
| 6 | Supply , transport , installation and commissioning of Solar PV installation for water pumping system consisting of solar panels framed in anodized aluminium frame mounted on stable hot dipped galvanized ( min 80 micron thickness) mild steel structure of rectangular hollow sections, angles, heavy duty pipes (all materials duly IS marked ) for providing sufficient strength with dual axis manual tracking arrangement which can withstand load of modules and high wind velocities upto 150 Km/hr, having RCC foundation designed against all possible loads (Dead, Live and imposed load). Modules supplied with the SPV system should have certificate as per IEC 61215 specification or equivalent National or International standards and must be interconnected with 4/6 sq.mm cables routed in PVC conduits properly fitted along the G.I structure to provide a good aesthetic view. Modules must qualify to IEC 61730 part I and part II for safety qualification testing. The power output of individual PV modules used in the PV array, under STC, should be of 335 Watts peak, with adequate provision for measurement tolerances. Solar cells should be crystalline silicon cell with min. efficiency of 14% and fill factor more than 70%, should be laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2mm tempered glass including appropriate DC to AC inverter and power controlling unit (protected with IP65 class enclosure) with MPPT technology to run at low sunshine and minimum 7 hours a day run with all necessary accessories suitable for solar + grid operation and including all protections of AC induction motor pump. There should be a display of all measurable parameters including storing of data at a set interval and transfer it in a pendive thru USB port . There should also be provision of interfacing GPRS based data transmission. The rate is inclusive of manufacturer's warranty and comprehensive maintenance for 1st year and comprehensive maintenace for 4 years beyond Ist year ( structure and foundation drawing enclosed for reference) Brand :Tata, Havells, Luminous |
| 7 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (White) - Multilayer (d) 2000 litre capacity |
| 8 | Supply, Installation testing & Commissioning Express Water 600 GPD Commercial Reverse Osmosis Water Filtration System – 5 Stage High-Capacity RO Filtration – Includes Pre-Filters, Pressure Pump, Controller, Gauges, and RO Membrane. with Solar Power Pump motor 1KW sets. Commercial RO Water Filter: Remove up to 99.99% of contaminants including Lead, Chlorine, Fluoride, Cyanide, Giardia, Radium, Asbestos, Calcite, Heavy Metal, Bacteria, Viruses, Pharmaceuticals, and other major contaminants. High Quality Commercial RO System: Express Water Commercial Reverse Osmosis Water Filtration Systems are designed to be compact and durable. Built with a stainless-steel frame, all components are protected and compactly organized for maximized storage Efficient Commercial Water Filter: This Commercial RO Filter is outfitted with a pre-installed computer interface module and easy-to-read gauges for maximum control and efficiency in your commercial water filter system. 5 Stage Commercial RO Filter: Express Water 5 Stage Commercial Water Filter Systems includes 5 micron Sediment filter, 2 Activated Carbon Block filters, Post-Activated Carbon filter and Reverse Osmosis Membrane for clean, clear, and fresh water wherever need it. Water test report is to be provided as per the direction of the EIC. Pump Should Be Kirloskar, Havells |
| 9 | Supplying, fitting, fixing, Chain link fencing of approved quality with R.C.C posts wooden posts or iron posts by means of galvanised \\"C\\" clips to grid of horizontal strands of galvanised high tensile spring steel wire of 12 S.W.G which have to be tensioned and fixed to the vertical posts by means of galvanised special clips, bolts and nuts etc. |
| 10 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. |
| 11 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (b) With earth obtained by fresh excavation (including cost of excavation upto 1,800 mm. depth) from land arranged by the Deptt. within a lead of 100 m. |
| 12 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 13 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes (ii ) River Bazree |
| 14 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m II. Other than SAIL/ TATA/RINL |
| 15 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation |
| 16 | Construction of Cement Concrete Platform as per desin around the hand pump in M-15 cement concrete for fixing the pedestal of hand pump including exacation, cost of meterial and labour etc. compete |
| 17 | Wire, cable features,on-off Auto Censer Device & others The newly released 1500volt connectors are withhighest current rating among connectorsused PV DC application.It supports the cable range up to 16sq-mm forTUV and 6AWG for UL.With higher voltage, higher current, and wider cable range, our TUV/UL 1500V/1000Vseriesprovide an optimal solution for customers toachieve \\"Balance Of System.\\" ISI Brand |
| 18 | Supplying, fitting-fixing of iron frame display board at working site including writing with carring all other charges completed. ( L.S.) |
| 19 | Add CGST |
| 20 | Add SGST |
| 21 | Add Labour Cess |
| 22 | Add Contingency Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayDec 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender