Defence Statutory Bodies & Commissions/Committees Closing in 25 days TDR #58658100

Tender For Conversion Of Oh To Ug Lt Cable And Connected Work Under Age E/M At Mil Stn Yol

Issued by Statutory Bodies & Commissions/Committees · Kangra, Himachal Pradesh
Tender Value
43.70 Lakhs
Estimated cost
Bid Submission
16 Dec 2026
25 days left
EMD
87400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kangra → Himachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Conversion Of Oh To Ug Lt Cable And Connected Work Under Age E/M At Mil Stn Yol

BOQ

Name of Work:- CONVERSION OF OH TO UG LT CABLE AND CONNECTED WORK UNDER AGE E/M AT MIL STN YOL
Sl. No. Item Description
1Earth work in excavation by mechanical means Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out in all kind of soil excavated soil and disposal of surplus excavated soil, within a lead of 50m complete all as specified and directed.
2Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in all kind of soil complete all as specified and as directed..
3Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes, 1100 volts grade, LT XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of following cross sectional area complete all as specified and directed.
4Cross sectional area 185 Sqmm, 3.5 core.
5Cross sectional area 150 Sqmm, 3.5 core.
6Cross sectional area 120 Sqmm, 3.5 core.
7Cross sectional area 95 Sqmm, 3.5 core.
8Cross sectional area 70 Sqmm, 3.5 core.
9Cross sectional area 50 Sqmm, 3.5 core.
10Cross sectional area 35 Sqmm, 3.5 core.
11Cross sectional area 16 Sqmm, 2 core.
12Double walled corrugated (DWC) pipe of size 110mm/96mm (OD/ID) including snap fit coupler conforming to IS16205 Part-24, 2017 for protection of cable in underground complete all as specified and directed.
13Double walled corrugated (DWC) pipe of size 90mm/76mm (OD/ID) including snap fit coupler conforming to IS16205 Part-24, 2017 for protection of cable in underground complete all as specified and directed.
14Double walled corrugated (DWC) pipe of size 75mm/63mm (OD/ID) including snap fit coupler conforming to IS16205 Part-24, 2017 for protection of cable in underground complete all as specified and directed.
15Double walled corrugated (DWC) pipe of size 50mm/38mm (OD/ID) including snap fit coupler conforming to IS16205 Part-24, 2017 for protection of cable in underground complete all as specified and directed.
16Galvanised steel tubing, light grade, 50 mm dia for protection of under ground cable on poles / walls under road crossing etc including dismantling & taking down existing pipe complete all as specified and directed.
17Galvanised steel tubing, light grade, 100 mm dia for protection of under ground cable on poles / walls under road crossing etc including dismantling & taking down existing pipe complete all as specified and directed.
18Dismantling unserviceable PCC/RCC poles/struts any type and size complete all as directed by Engr-in-charge.
19Dismantling unserviceable steel poles/struts any type and size complete all as directed by Engr-in-charge.
20Dismantling unserviceable insulator any type and size complete all as directed by Engr-in-charge.
21Dismantling unserviceable Cross arms of M-S Channel or angle sections etc, complete and setting aside for re-use, any type and size complete all as directed by Engr-in-charge.
22Dismantling unserviceable stay assembly including demolition of concrete, any type and size complete all as directed by Engr-in-charge.
23Dismantling unserviceable ACSR conductor including earth wire or service feeder or distributor span complete all as directed by Engr-in-charge.
24M&L for Cutting of roads / pathway n. exc 0.9m width for laying of cables of any size and type, complete all as directed .Repair to road by providing soling with broken boulders or quarried stone and applying cold emulsion mixed with Aggregate as per manufacturers instruction including necessary compaction by rolling etc.; match and removal and refixing of existing interlocking paver blocks for cable laying including careful dismantling ,stacking ,excavation ,backfilling , compaction and restoration by refixing the same paver blocks to the original condition , including replacement of damaged blocks ,joint filling completed all as directed.
25Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to GI Strip 25mmX4 mm by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15 mm bore including provn of concrete pit in plain cement concrete M-20 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of reinforced cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate, reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
26Supply and fix PVC insulated and sheathed copper conductor cable of size 2.5sqmm, 3 core including of PVC Conduit 20 mm dia, for connection between street light junction box to street light complete all as specified.
27Scraping of old paint from the steel tubular pole / RCC Pole 9 mtr height with out removing accessories and preparation of the old surfaces and applyong one coat of aluminium paint in alternative blue and white strips of 30 cm each upto 1.5m height, marking the pole No with black enamel paint over yellow circle of dia 100mm. Repainting the remaining pole and iron parts i.e U clamps, channels etc above 1.5 mtr height comp,ete all as directed.
28Supply and fix Street light Pole Cable junction box shall be made out of Thermoplastic Polycarbonate (PC-GFS) shock proof and rust free with IEC 60529: IP 66/IP 67/IP 69 degree of protection. IEC 60999: Connecting devices, safety requirements for Screw-type and screw-less –Type clamping units for electrical copper conductors.IEC 60695-2-11: 960 °C UL Subject 94: V-0, Glow wire test , flame-retardant self-extinguishing. Impact Resistant : IK 09 ( 10 joule ) .Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which are well visible (open – locked), and they will be sealable. Junction Box with multi-level knockouts as well as from rear side also for cable entries in different sizes for unprotected outdoor (UV resistance) with internally embedded gasket technology (Polyurethane).The junction box shall have elongated mounting holes for pole mounting provision however external brackets for wall fixing must be included. Lid retaining strap shall be provided along with junction box to prevent the lids from falling or losing away during maintenance work. The junction box shall be resistant against, Petrol, 10% acid, 10% Lye, mineral oil, alcohol, seawater. Temperature resistance -40°C to +120°C..IEC 60670-22: Particular requirements for connecting boxes and enclosures.IEC 60754 – 2: Halogen – free: Low toxicity, low fume development.the box shall have Rated Insulated Voltage 1000 V AC/DC.Size of Junction Boxs Shall be 205 x 255 x 112mm having 6A Sp 10ka Mcb with suitable 4way terminal block. cat no. KF 2500 G including of DK Pole mounting kit Catalog No . DK MB 3 and combination Ventilation Glands(Black ) KBS M 25. Make : Hensel /Schneider/Legrand. (Cables enteries should be through proper cable gland.)
29Supply, installation, commissioning and testing bus chamber factory made Outdoor type, CPRI approved, size 0.45mx0.75mx0.4m deep, fabricated out of 3.15 mm thick mild steel sheet and vermin proof with neoprene gasket having front opening and locking arrangement with IP-54 protection as per IS-8623, duly powder coated (Internally and externally) for 415 volts, 3 phase, 4 wire having aluminium bus bars of 400 Amps rating duly drilled holes for connections, RYB insulated with different color code and sleeved insulators complete prewired and copper cable connection with all incoming and outgoing cable connection with suitable size of lugs and glands including one No MCCB with adjustable thermal and fixed magnetic release of capacity of 250 amps, 415 volt, 25 KA, 4 pole fixed with LED phase indicators(R,Y,B)suitable for 3 phase 4 wire supply system in PCC M-15, type B-0, using 12.5 mm graded crushed stone aggregate all as specified.Note : (a) Incoming and outgoing cables shall be fixed with appropriate size of thimble (b) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (c)No Extra Payement will be made for Cable Glands , Thimbles and disconnecting old existing outgoing cables from existing poles & connecting to New panels with proper size of metallic glands and thimble. (d) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and panel shall be brought at site as per approved drawing (e) The contractor shall provide and construction an RCC foundation of suitable size and height for the installation of the LT Panel prior to placing the busbar panel stand, complete with all necessary excavation, PCC, reinforcement, formwork, concreting, curing, backfilling, and other incidental works, as directed by the Engineer-in-Charge. Note:- Rate quoted by the contractor included all the above provision.
30Supply, installation, commissioning and testing bus chamber factory made Outdoor type, CPRI approved, size 0.45mx0.75mx0.4m deep, fabricated out of 3.15 mm thick mild steel sheet and vermin proof with neoprene gasket having front opening and locking arrangement with IP-54 protection as per IS-8623, duly powder coated (Internally and externally) for 415 volts, 3 phase, 4 wire having aluminium bus bars of 250 Amps rating duly drilled holes for connections, RYB insulated with different color code and sleeved insulators complete prewired and copper cable connection with all incoming and outgoing cable connection with suitable size of lugs and glands including one No MCCB with adjustable thermal and fixed magnetic release of capacity of 200 amps, 415 volt, 25 KA, 4 pole with LED phase indicators(R,Y,B)suitable for 3 phase 4 wire supply system fixed in PCC M-15, type B-0, using 12.5 mm graded crushed stone aggregate all as specified. .Note : (a) Incoming and outgoing cables shall be fixed with appropriate size of thimble (b) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.(c) No Extra Payement will be made for Cable Glands , Thimbles and disconnecting old existing outgoing cables from existing poles & connecting to New panels with proper size of metallic glands and thimble.(d) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and panel shall be brought at site as per approved drawing.(e) The contractor shall provide and construction an RCC foundation of suitable size and height for the installation of the LT Panel prior to placing the busbar panel stand, complete with all necessary excavation, PCC, reinforcement, formwork, concreting, curing, backfilling, and other incidental works, as directed by the Engineer-in-Charge. Note:- Rate quoted by the contractor included all the above provision.
31Supply, installation, commissioning and testing bus chamber factory made Outdoor type, CPRI approved, size 0.45mx0.75mx0.4m deep, fabricated out of 3.15 mm thick mild steel sheet and vermin proof with neoprene gasket having front opening and locking arrangement with IP-54 protection as per IS-8623, duly powder coated (Internally and externally) for 415 volts, 3 phase, 4 wire having aluminium bus bars of 500 Amps rating duly drilled holes for connections, RYB insulated with different color code and sleeved insulators complete prewired and copper cable connection with all incoming and outgoing cable connection with suitable size of lugs and glands including one No MCCB with adjustable thermal and fixed magnetic release of capacity of 400 amps, 415 volt, 25 KA, 4 pole with LED phase indicators(R,Y,B)suitable for 3 phase 4 wire supply system fixed in PCC M-15, type B-0, using 12.5 mm graded crushed stone aggregate all as specified. .Note : (a) Incoming and outgoing cables shall be fixed with appropriate size of thimble (b) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. (c) No Extra Payement will be made for Cable Glands , Thimbles and disconnecting old existing outgoing cables from existing poles & connecting to New panels with proper size of metallic glands and thimble. (d) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and panel shall be brought at site as per approved drawing.(e) The contractor shall provide and construction an RCC foundation of suitable size and height for the installation of the LT Panel prior to placing the busbar panel stand, complete with all necessary excavation, PCC, reinforcement, formwork, concreting, curing, backfilling, and other incidental works, as directed by the Engineer-in-Charge. Note:- Rate quoted by the contractor included all the above provision.
32M& L for Cable route indicator made out of 2 mm thick mild steel sheet of size 20cm X 15cm duly coated with two coats of black paint over a coat of red oxide primer duly written the size of LT cable in white paint and welded to equal angle of size 30X30X3mm, 60 cms long and errected in ground in such a way that it is 30 cm above ground level and 30 cm below ground level. The portion below ground level should be embedded in plain cement concrete M-15, type B-I, using 20 mm graded crushed stone aggregate of size 15 cm X 20 cm X 45 cm all as specified & directed.Note:- Cost of PCC and earth work & excavation shall be deemed to be included in unit rate quoted by contractor.
33Deduction to be made from BOQ for Sch 'A' Part-II (Schedule of credit) Note: Tenderers shall not quote for this schedule. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58658100
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.70 Lakhs
LAST DATE 16-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Conversion Of Oh To Ug Lt Cable And Connected Work Under Age E/M At Mil Stn Yol
Basic Detail
Tender No GE/Y-107/2026-27
Bidding Type Tender
Location
City Kangra
State Himachal Pradesh
Key Dates
Publish Date 21 Nov 2026
Submission Date 16 Dec 2026
Open Date 18 Dec 2026
Finance
Tender Value 43.70 Lakhs
Tender Fee 500
EMD 87400
Exemption Available
Document List
BOQ_897419.xls
ebd70685-0164-46bc-89c7-a110b6601166.html
Tender107.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 21, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Dec 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 25 days
Dec 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_897419.xls

html

ebd70685-0164-46bc-89c7-a110b6601166.html

pdf

Tender107.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender