Tender For repair maintenance E And M Services At 100 Bedded Lbs Hospital, Khichripur, Delhi. (Sh: Repairing Of Spare Parts And Comprehensive Maintenance Contract Of Ups System Installed At Various Ayushman Arogya Mandir &Delhi Govt. Dispensaries).
Tender Overview
Project Description
Tender for repair maintenance E And M Services At 100 Bedded Lbs Hospital, Khichripur, Delhi. (Sh: Repairing Of Spare Parts And Comprehensive Maintenance Contract Of Ups System Installed At Various Ayushman Arogya Mandir &Delhi Govt. Dispensaries).
BOQ
| Sl. No. | Item Description |
| 1 | (A) CMC of UPS of Labotek MakeComprehensive Maintenance Contract of following True Online double conversion VFI technology, High Frequency PWM using IGBT technology, Parallel redundant, 3phase AC Input & 3phase AC Output UPS. Input range should be 360 VAC- 450 VAC, Dual input (separate input for rectifier and separate input for bypass). (Make - Labotek) a) Capacity 10KVA x 4Nos |
| 2 | b) Capacity 20KVA x 2Nos |
| 3 | c) Capacity 30KVA x 4Nos |
| 4 | Comprehensive Maintenance Contract of Isolation Transformer K-13 rating cubicle IP-20 With Copper Winding. (Make - Datson)a) Capacity 30KVA x 2Nos |
| 5 | b) Capacity 40KVA x 4Nos |
| 6 | Comprehensive Maintenance Contract of Microprocessor Based Transient Voltage Surge Suppression (TVSS) System with reset facility High/Low voltage protection etc. complete as reqd.a) Capacity - 50KA x 12Nos |
| 7 | Comprehensive Maintenance Contract of following capacity microprocessor based automatic phase sequence corrector for nonstop smooth functioning of 3 phase critical equipment i/c repairing and replacement of all defective parts during comprehensive maintenance period etc. complete as reqd. (Make: Magnaflux)a) Capacity - 100Amp. x 06 Nos |
| 8 | Comprehensive Maintenance Contract of following capacities Make Magnaflux of Static Switch Modules:-a) Capacity - 63Amp. x 12Nos |
| 9 | (B) Repairing works1. Ayushman Arogya Mandir KalyanvasRepairing of 10KVA UPS Spares Required in repairing are as below:ISD1MB – 3 Nos.IGBT 100/600 – 6 Nos.PWM PCB – 1 No.PWM Card – 1 No.HRC Fuse – 1 No (Buyback material credit to the contractor) |
| 10 | Repairing of 20KVA UPS Spares Required in repairing are as below:MCRF PCB – 1 No.SCR – 4 Nos.Snubber Driver – 2 Nos.D3 Card – 1 No.IGBT 200/1200 – 1 No.HRC Fuse – 3 Nos. (Buyback material credit to the contractor) |
| 11 | Repairing of Isolation Transformer -30KVA Spares Required is as belowCooling Fan -1 No.Temperature Sensor – 1 NoCopper Busbar – 1 Lot (Buyback material credit to the contractor) |
| 12 | Repairing of 100Amp APSC Spares Required in repairing are as below:Contractor 100A – 1 Nos. (Buyback material credit to the contractor) |
| 13 | 2. Ayushman Arogya Mandir IP ExtensionRepairing of 30KVA UPS Spares Required in repairing are as below:FS1 PCB – 1 No.AC Capacitor 60mfd – 1 No.DC Capacitor 2200mfd/450VDC – 5 Nos.PWM PCB – 1 No. (Buyback material credit to the contractor) |
| 14 | Repairing of Isolation Transformer -40KVA Spares Required as belowHeavy Duty Terminal Block- 1 SetHRC Fuses – 1 LotLCD display – 1 No.MCCB – 1 No. (Buyback material credit to the contractor) |
| 15 | Repairing of 100Amp APSC Spares Required in repairing areas below:Contractor 100A – 2 Nos. (Buyback material credit to the contractor) |
| 16 | 3. Ayushman Arogya Mandir KondliRepairing of 10KVA UPS Spares Required in repairing are as below:ISD1MB – 3 Nos.DC Capacitor 2200mfd/450VDC – 5 Nos.Static PCB – 1 No.IGBT 100/600 – 6 Nos.PWM PCB – 1 No.PWM Card – 1 No (Buyback material credit to the contractor) |
| 17 | Repairing of 30KVA UPS Spares Required in repairing are as below:D3HBM PCB – 1 No.ISD1MB – 3 Nos.IGBT 200/1200 – 1 No.Chain 3 PCB – 1 No. (Buyback material credit to the contractor) |
| 18 | Repairing of Isolation Transformer -40KVA Spares Required as belowControl MCB -1 No.MCCB -1 No.Soft Starter Controller – 1 No. (Buyback material credit to the contractor) |
| 19 | 4. Ayushman Arogya Mandir VasundharaRepairing of 10KVA UPS Spares Required in repairing are as below:Chain 3 PCB – 1 No.IGBT 100/600 – 4 Nos.PWM PCB – 1 No. (Buyback material credit to the contractor) |
| 20 | Repairing of 30KVA UPS Spares Required in repairing are as below:Charger PCB – 1 No.1GBT 200/1200 – 1 No.HBPSN2 Card – 1 No (Buyback material credit to the contractor) |
| 21 | Repairing of Isolation Transformer -40KVA Spares Required as belowCooling fan -1 No.HRC Fuses – 1 LotHeavy duty resistance – 1 No. (Buyback material credit to the contractor) |
| 22 | 5. DGD TrilokpuriRepairing of 20KVA UPS Spares Required in repairing are as below:IGBT 200/120 – 1 No.D3 Card – 2 Nos.Fuse – 3 Nos.Snalper – 1 No.N2 Card – 2 Nos.ISD1MB – 3 Nos. (Buyback material credit to the contractor) |
| 23 | Repairing of Isolation Transformer -30KVA Spares Required is as belowLCD display -1 No.Copper Busbar – 1 LotControl MCB – 1 No. (Buyback material credit to the contractor) |
| 24 | Repairing of 2x63 Amp SSM Spares Required in repairing areas below:Contactor 63Amp – 2 Nos.Mother Board – 2 Nos. (Buyback material credit to the contractor) |
| 25 | 6. DGD HimmatpuriRepairing of 30KVA UPS Spares Required in repairing are as below:N2 Card – 2 Nos.IGBT 200/600 – 1 No.PWM Card – 1 No.Fuse 63K07660 – 1 No.Chain 3 Card – 1 No.ISD1MB – 3 Nos. (Buyback material credit to the contractor) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender