Agriculture Boards / Undertakings / PSU Closing in 11 days TDR #58658039

Tender For Annual Repairs And Maintenance Operations Of Electrical Installations At Fsd Udupi For The Fy 2026-27. Sh: Replacement Of Damaged Ug Cables, Led Fixtures, Panel Board, Switchgears And Other Allied Works.

Issued by Boards / Undertakings / PSU · Udupi, Karnataka
Tender Value
8.15 Lakhs
Estimated cost
Bid Submission
02 Dec 2026
11 days left
EMD
16310
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udupi → Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Annual Repairs And Maintenance Operations Of Electrical Installations At Fsd Udupi For The Fy 2026-27. Sh: Replacement Of Damaged Ug Cables, Led Fixtures, Panel Board, Switchgears And Other Allied Works.

BOQ

Name of Work:- Annual repairs and maintenance operations of electrical installations at FSD Udupi for the FY 2026-27. SH: Replacement of damaged UG cables, LED fixtures, Panel board, Switchgears and other allied works.
Sl. No. Item Description
1Re wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2Group C
3Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
43 X 2.5 sq. mm
5Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
65/6 A switch
715/16 amp switch
83 pin 5/6 amp socket outlet
96 pin 15/16 amp socket outlet
10Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required
1112 Module (200mmX150mm)
12Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB omplete with connections, testing and commissioning etc. as required.
13Single pole
14Supplying, installation, testing and commissioning of 20W Retrofit type Photon Ultra bright LED polycarbonate tubelight (Single side connection in existing Luminaire batten including connection, testing and as required.
15Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
16Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 ̊C to 50 ̊C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10%as per IEC 61000-3-2, P. F.≥ 0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
17250 W
18100 W
19Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
2018- 22 Watt
21Supply, installation, testing, and commissioning of an industrial LED Well Glass light fixture featuring a pressure die-cast aluminium housing with a toughened glass cover and integrated electronic driver (140–270V AC, Power Factor ≥ 0.95, surge protection ≥ 4 kV, delivering a system efficacy ≥105 lm/W at 4000K–6500K CCT with CRI >70$, ingress protection rating IP65/IP66, suitable for ceiling, wall, or pipe mounting, complete with internal/external wiring using 1.5 sq.mm copper cable, earthing, terminal connections, a minimum rated lifespan of 50,000 burning hours, and a 5-year OEM warranty as approved by the Engineer-in-Charge.
2270 watt
2340 watt
24Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
251200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
26Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required.(Approved make:CCI/Omega/PolyCab/Finolex/Havells/V-Gaurd/Universal)
274 x 25 sq.mm
284 × 16 sq.mm
293 x 10 sq.mm
30Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
314 X 25 sq. mm (28mm)
324 X 16 sq. mm (28mm)
333 X 10 sq. mm (22mm)
34Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.up to 35 sq.mm.
35Up to 35 Sq mm
36Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
37Upto 35 sq. mm (clamped with 1mm thick saddle)
38Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
3963 mm dia (OD-63 mm & ID-51 mm nominal)
40Design, Fabrication, Supplying, Installation, Testing and commissioning of Concrete base Mounted Dust and vermin proof Cubicle type box suitable for 3 Phase, 415v, 50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel with doors and painted with powder coating in approved shade, ELR with CBCT, Complete with aluminium busbars of adequate capacity for Phases & neutral, Suitable M.S Angle Base Frame of 50 X 50 X 6 mm, interconnections control wiring, including incoming and outgoing cables connections, Door Earthing 2.5 mm Flexible Copper, suitable spread terminals for MCCBs, danger plate etc as required at site of work and as directed by the Engineer in charge. of following sizes and switchgear:
41Size: 1500(L) x 1350(L) x 350(L) cm with 2 mm CRCA Sheet with doorsBus Bar Size: 30 x 6 mm Aluminium- 4 no.s- 1400 mm length each.Earth Bar: 25 x 5 mm Copper- 1 no.- 1400 length.Incoming: 4 pole MCCB, 150A, 36KA- 1 No with extended rotary handleOutgoing: 125A, 4 pole MCCB, 36KA- 1 No with extended rotary handle63A, 4 Pole MCCB, 25/30KA- 04 Nos32A, 2 Pole MCB, 10KA- 2NosMetering PannelingDigital Voltmeter - 01 NosDigital Ammeter - 01 NosRYB phase indication lamps -1 set6A SP MCB for control Ckts -03 Nos
42Dismantled scrap of MS conduit/DB's/GI wir/clamps etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58658039
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 8.15 Lakhs
LAST DATE 02-12-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for Annual Repairs And Maintenance Operations Of Electrical Installations At Fsd Udupi For The Fy 2026-27. Sh: Replacement Of Damaged Ug Cables, Led Fixtures, Panel Board, Switchgears And Other Allied Works.
Basic Detail
Tender No 08/2026-27
Bidding Type Tender
Location
City Udupi
State Karnataka
Key Dates
Publish Date 21 Nov 2026
Submission Date 02 Dec 2026
Open Date 03 Dec 2026
Finance
Tender Value 8.15 Lakhs
Tender Fee Ref. Documents
EMD 16310
Exemption Not Available
Document List
BOQ_982886.xls
d0edc04b-0548-437f-b2ad-61ac8902928e.html
MTFUDUPI202627ARMO.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 21, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Dec 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Dec 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_982886.xls

html

d0edc04b-0548-437f-b2ad-61ac8902928e.html

pdf

MTFUDUPI202627ARMO.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender