Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #58655573

Tender For Provn Of 01 X Dedicated Transformer Of 315Kva Alongwith Its All Connecting Accessories For Fast Charging Point Of 240 Kw Capacity (Charging Stn For Elect Veh) At Afmc Pune Under Ge (Central) Pune.

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
23.20 Lakhs
Estimated cost
Bid Submission
12 Dec 2026
21 days left
EMD
46400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of 01 X Dedicated Transformer Of 315Kva Alongwith Its All Connecting Accessories For Fast Charging Point Of 240 Kw Capacity (Charging Stn For Elect Veh) At Afmc Pune Under Ge (Central) Pune.

BOQ

Name of Work:- PROVN OF 01 X DEDICATED TRANSFORMER OF 315KVA ALONGWITH ITS ALL CONNECTING ACCESSORIES FOR FAST CHARGING POINT OF 240 KW CAPACITY (CHARGING STN FOR ELECT VEH) AT AFMC PUNE UNDER GE (CENTRAL) PUNE.
Sl. No. Item Description
1Supply, install, testing and commissioning plinth mounted step-down outdoor type distribution transformer HT 22KV, 3Ph, LT 433V, 4wire, capacity 315 KVA copper wound, oil cooled, vector symbol Dyn-11, HV-delta, LV-Star connected complete with all standard fittings as per IS:1180 and latest amendments. HT side cable box type/Bare terminal and LT side cable box , off load type tap changer hand operated having taping at HV for variation (+) 5.0% to (-)10.0% in equal steps of + 2.5%, temperature rise in permitted oil/winging by self-resistance method at normal ratio 45°C with first filling of transformer oil of suitable dielectric strength with Energy efficiency levels Minimum Level 2 rated (Maximum total loss as per table 6 of IS 11480 part I 2014 and latest amendments thereafter at impedance 4.5 %), the fittings and accessories like Oil conservator tank with drain Plug and filling cap, silica Gel dehydrating breather charged with silica gel, Oil Level guage, Oil filter Valve,Oil drain valve, Thermometer Pocket with thermometer, Diagram and rating Plate, Two earthing arrangements, Lifting Lungs, four bidirectional plain roller, Air vent plug, exploxion vent, Cooling radiators,CI Rollers, an additional neutral terminal brought outside the LV cable box for earthing etc all as specified and directed.
2NOTES FOR SER. ITEM NO. 1.00 Above :-(a) The transformer shall have complete standard fittings such as two earthling terminals with earthling symbols for body, Air release device, rating and terminal marking plates, conservator tank with oil filling hole, filter type drain valve and oil level gauge. The transformer shall also have dehydrating breather with first fill of dehydrating agent (Silica Gel), drain cum sampling valve, winding temperature indicator and oil temperature indicator, lifting lugs for the complete transformer as well as core and winding assembly, pressure release device/explosion vent ,unidirectional flat rollers, inspection holes, LV earthling arrangement.(b) HT side cable box type consisting of 3 numbers of Porcelain bushing with Brass rods complete with nuts and washers, with cable glands suitable for reception / taping out 3 core HT cable 22 KV grade of size upto 185 Sqmm and a LT side cable box consisting of 4 numbers of porcelain bushing with Brass rods (Bimetallic flexible connecter and copper bus bar of suitable rated capacity with insulator support) and an additional neutral terminal brought outside the LV cable box for earthIing etc with complete with nuts and washers, with cable glands suitable for reception / taping out 3.5 core LT cable 1100 V grade of size upto 400 Sqmm.(c) The contractor shall submit a letter of acceptance from the transformer manufacturer along with a sample, seeking approval. The manufacturer must clearly confirm in the letter that their company agrees to provide all requisite details and documentation and certification requirements as mmentioned in the succeeding paragraphs(d) Expenses/cost of FAT and necessary ravel/freight/conveyance/stay expense for inspecting/testing officers as nominated by accepting officer for FAT shall be included in the rate quoted.(e) The contractor or his authorized representative shall submit the complete documentation and certificates to the Factory Acceptance Testing officer detailed by the department. The details shall include but not be limited to:(f) Rating of Tapping parameters/steps of the transformer. (i) Maximum permissible temperature rise in the Core and Oil of transformer. (ii) Manufacturer details of the material used in core/winding conforming to CRGO specifications, including ,Grade of CRGO, name of the manufacturer along with supporting documents such as invoice copy, mill test certificate, customs certificate, and any other relevant proof (iii) Test report of the Flux density of the core. (iv) Test report of the Overflux withstand capacity, including duration (in minutes) the transformer can sustain for in overflux conditions (v) Test report for Noise level of the transformer, as per standard norms (vi) No-load current consumption Percentage of the transformer (vii) Burr level certificate indicating maximum burr level value in the transformer (viii) Certification of purity of copper used in transformer winding. (ix) The OEM of the transformer should have accreditation certificate from NABL
3NOTES FOR SER. ITEM No. 1.00 CONTD....(g) Manufacturer/OEM must have type test/ short circuit reports for each and every rating from CPR/ERDA. ( Matching all the parameters including the loss figure) shall not be older than 5 Years to be furnished)(h) CPRI short circuit test report exactly similar transformer (matching all major electrical parameters including Loss figure) shall not be older than 5 Years to be furnished).Transformer test reports must clearly indicate that they pertain to the transformer itself, along with the acceptance parameters and the applicable technical authority or literature—such as IS 1180:2014 (Part I) and its subsequent amendments, IS/IEC 60076, CBIP Manual 317, NEMA standards, or any other recognized government-authorized body.
4M&L for Construction of Plinth for transformer (to withstand the load of 315 KVA transformer) of size as directed 2.0mx 2.0mx1.5m, using 100 mm thick PCC 1:4:8 type D-2 as in lean concrete, brick masonry in CM 1:6, the top of the plinth shall consist of 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) over 75 mm thick PCC 1:4:8 type D-2 over compacted moorum filling, 10 mm thick rendering in CM 1:4 on brick surface, duly placement of two number of medium channels of size MC 100 mm on floor of Plinth accross the length of Plinth for equal distribution of transformer’s load, complete all as specified and directed.
5Supply & laying HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 22 KV cross sectional area 95 Sqmm 3 Core conforming to IS 7098 lead in duct/trenches complete all as specified and directed.
6M&L for end termination heat shrinkable out door type kit complete with jointing material and accessories for HT 22 KV 95 Sqmm 3 core cable including testing complete all as specified and directed.
7M&L for earthing for sub station equipments (Transformer, lightning arrestor and feeder pillar box) complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of equipments etc at the other, earth strip encased in and including 40mm bore GI medium grade pipe with all fittings from top of electrode to body of equipment fixed with and including 40 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work , etc.complete all as specified and shown in electrical plate No 3 of SSR Pt-I. complete all as specified and directed. (Note : (i) Refilling of the earth pit shall be carried out with black cotton soil. (ii) GI strip 32 x 6 mm & GI protection pipe upto 7.5 m length will be measured under this item.)
8Supply, installation, commisioning and testing of chemical earthing with GI Electrode 3 mtr long consist of GI pipe outer dia 76mm and GI pipe inner dia 32 mm inner space should be compacted with dry chemical compound for enhancing conductivity all including boring, installation, transportaion, earth work and sufficient qty of ground enhancing backfil compound testing of soil condition, PVC pit cover and GI strip 32X6 mm up to 7.5 mtrs long etc complete all as specified and directed.
9S&F GI strip 32 x 6 mm for extension of earth and connected to equipment or panel complete all as specified and directed.
10Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of LT UG cable/ poles in hard and dense soil and getting out complete all as specified and directed.
11Excavation in trenches, not exc 1.5 mtr wide and exc 1.5 mtr but not exc. 3.0 mtr in depth for laying of LT UG cable/ poles in hard and dense soil and getting out complete all as specified and directed.
12Returning filling in incluiding spreading levelling watering and well ramming in layers n.exc 25 cm complete all as specified and diredcted.
13Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
14M&L for PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in coping of new pole / reconstruction old damaged copings including necessary form work complete all as specified and directed.
15M&L for PCC 1:3:6 type C-2 using 40mm grade stone aggregate as in foundation of poles/ feeder piller box repair to floor/paths, road cuttings, fencing etc including use and waste of necessary form work and fair finishing without using extra cement complete all as specified and directed.
16M & L for Reinforced concrete pipes of dia 150 mm 2 nos half round (each of 1 RM long for bottom and top ) and before laying excavated area shall be levelled all as specified and directed.
17M & L for GI Tubes of size 100mm dia, 'light grade', galvanised, with all fittings laid in trenches complete all as specified and directed.
18Supply, installation, testing and commissioning of new Outdoor type LT panel board cubical, CPRI approved make and canopy type with double door, double side openable, ventilated, vermin proof, floor mounted with MS angle iron base frame made out of 40x40x6mm angle, with angle iron Stand made out of 50x50x6 mm thick having 4 Nos legs of 3.00 feet height of size as required at site,grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements, vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated copper bus bar of suitable size to carry 630 amps four Nos vertical/Horizontal mounted of suitable length and internal wiring with of suitable size duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint and marking wiring circuits, complete all as specified and as directed duly comprising of the following :-
19CONTD...SER. ITEM No. 16.00 Above(a) MCCB 4 Pole, 415 Volts, 50 KA Adjustable Thermal & Adjustable Magnetic 630 Amps. - 1 No., Ics = 100% Icu(b) MCCB 400 Amp FP 36KA MCCB with adjustable thermal setting - 2 Nos(c) Ammeter of 0-500 ampere AC supply, with selector switches 01 Nos.(d) Voltmeter for 0-500 Volt AC supply, with selector switches . 1.00 Nos.(e) 01x KWAH meter to be fitted along with its connection and initial settings. (f) LED indicating lamps complete with logged switches 1.00 Set
20M&L for earthing with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed / screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. (Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
21Supply, Errecting and fixing of true Vertical position steel tubular swaged pole type 410 SP-55 (11.0 metres) complete with coat iron base plate, final taper plug, bolt, nuts and screw, weld and reduced section and logitudional weld Seam through out entire length of pole including two coats of black bituminious paint through out internally and externally upto planting depth and remaining exterior portion of pole with two coats of aluminium paint over a coat of red oxide as specified and directed at site. (NOTE - Excavation and Earth work and PCC in foundation shall be measured and paid seprately.)
22Supply and fix gang operated air break switch (Porcelein/Polymeric as per approval) of 22KV Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps, with locking arrangement including 6 lever lock ISI marked with 3 keys and fixing on existing 2/3/4/6/8 pole structure complete all as specified and directed.
23S&F drop out (DO) fuse unit expulsion type (Porcelein/Polymeric as per approval), outdoor type 400 amps rating single pole mounted on two insulators fixed to and including MS channel with nuts bolts washers etc. synthetic bounded fuse carrying tube complete with HT fuse element 25A capacity for HT 22 kV working pressure and fixing on existing four pole structure complete all as specified and as directed.
24Supply, laying, testing and commissioning of LT cable of 240 Sqmm 3.5 core 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/DB in building etc to suit the cable along with material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and directed.
25S&F Lightning arrestors expulsion type complete with all fittings, 65 KA discharge capacity, 22 KV distribution class made out of Porcelein/Polymeric (as per approval), 3 Nos of suitable size insulators complete alongwith connection all as specified and directed.
26S&F Danger notice plate of size 25cm x 20cm not less than 1 mm thick mild steel sheet, vitreous enameled white, 22 KV with letters, figures, and conventional skull and bones in signal red colour and fixed with MS clamps including all accessoried complete all as specified and directed.
27S&F chain link fencing 4mm dia galvanised steel wire, around 150x100 mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling and all necessary connections to the poles/channels/angle iron/strip and with one coat of aluminium paint complete all as specified and directed by EIC.
28M&L for cross arms bracing, supports, clamps, back plates, hooks etc, fabricated from structural steel sections ( M.S. Channels, angle sections, flat, round or square bars etc) of required sizes and shapes, including bolts, nuts and washers, welding, bending, cutting cold or hot, drilling holes for inserting bolts, in any shape or size, as indicated or directed complete including painting with one red oxide primer coat, two coats of aluminium paint complete all as specified and directed.
29Supply and laying graded coarse stone aggregates of size 30 to 40 mm in the sub station yard for complete all as specified and as directed.
30S&F earth continuity conductor or main earthing GI lead fixed to wall or pole on floor of size 4mm dia steel wire complete all as specified and directed.
31S&F Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as specified and directed.(Note : Clamps measured separately)
32S&F ACSR conductor with suitable insulating sleeves incl jointing with existing conductor/busbar/GOD and proper fastening to pin/shackle insulators/GOD with aluminium binding wires required jumpering connection complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58655573
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 23.20 Lakhs
LAST DATE 12-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of 01 X Dedicated Transformer Of 315Kva Alongwith Its All Connecting Accessories For Fast Charging Point Of 240 Kw Capacity (Charging Stn For Elect Veh) At Afmc Pune Under Ge (Central) Pune.
Basic Detail
Tender No 86230
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 21 Nov 2026
Submission Date 12 Dec 2026
Open Date 14 Dec 2026
Finance
Tender Value 23.20 Lakhs
Tender Fee 500
EMD 46400
Exemption Available
Document List
86230TenderDocs.pdf
b1d1695e-ff74-414f-addd-07bee9e44ff1.html
BOQ_897382.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 21, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Dec 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Dec 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
pdf

86230TenderDocs.pdf

html

b1d1695e-ff74-414f-addd-07bee9e44ff1.html

xls

BOQ_897382.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender