Tender For Addition/Alteration Of Building For Hrm And Accts Section At Af Stn Mohanbari

BOQ

Name of Work:- ADDN/ ALTN OF BUILDING FOR HRM AND ACCTS SECTION AT AF STN MOHANBARI
Sl. No. Item Description
1Surface excavtion in soft/ loose soil n.exc 30 cm in depth and averaging 15 cm deep and getting out complete all as specified and directed.
2Excavtion in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundations, etc or for shafts,wells, cesspits, manhole, pier holes, etc. n.exc 10 Sqm on plan and n.exc 1.5 mtr in depth in soft/ loose soil and getting out complete all as specified and directed.
3Excavtion. in trenches n.exc 1.5 mtr wide but exc 1.5 mtr in depth for foundations, etc or for shafts,wells, cesspits, manhole, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 mtr in depth in soft/ loose soil and getting out complete all as specified and directed.
4M&L for plain cement concrete 1:4:8 type D2 using 40 mm graded aggregate crushed stone aggregate as in foundations/ mass concrete complete all as specified and directed.
5M&L for RCC M25 (20mm graded stoen aggregate) as in foundations, including raft,footings, foundation beams, plinth beams, bases for columns,etc basement slabs, under reamed piles and mass concrete complete all as specified and directed.
6Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in depth complete all as specified and directed.
7Removal of excavted soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
8M&L for RCC M-25(20mm graded aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.
9M&L for RCC M-25(20mm graded aggregate) as in slabs supported on walls,roof beams and shelves and like complete all as specified and directed.
10M&L for RCC M-25(20mm graded aggregate) as in chajjas complete all as specified and directed.
11Use and waste of formwork to sides of concrete foundations, footings, sides and soffits of foundations (if any) of foundation and plinth beams and similar work, verticalor to batter for rough finished surfaces complete all as specified and directed.
12Use and waste of formwork to sides and soffits of floors or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports. Overhangs, etc splays between floors and beams for flat fair finished surfaces complete all as specified and directed.
13Use and waste of formwork to sides of pillars, posts,struts, piers, columns and stanchionsfor fair finished surfaces complete all as specified and directed.
14Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges, fair finished flat concrete surfaces complete complete all as specified and directed.
15M&L for TMT steel bars ,as in reinforcement, 10 mm dia and over, cut to length, bent to shape required, including cranking, hooking ends and blinding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
16All as item No 15 above herein before but 8 mm dia and over upto and including 10 mm dia as in stirrups, spacers and blinders etc complete all as specified and directed.
17M&L for brick work with sub class 'B' bricks(old size), straight or curved on plan exceeds 6m mean radius, built in cement mortar 1:4 complete all as specified and directed.
18M&L for 40 mm thick Damp proof course In cement concrete 1:2:4, type B-0 to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
19M&L for polythene film, black, 50 micron laid in floors complete all as specified and directed.
20M&L for Fe410-W (Gde-250) quality B roof truss (framed), trussed, prulins, crane gantries, rails, and fasteining and heavy bracket framing (beams, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
21M&L for girder or single stanchion, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections Fe410-W (Gde-250) quality B complete all as specified and directed.
22M&L for mild steel bolts of 20 mm dia purpose made with hexagonal or square head one end and serewed other end or screwed both ends, each serewed end to end fitted with washers and one hexagonal or square nut, exc 30 cm long complete all as specified and directed.
23S&F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screw (heavy duty) with in built washers and neoprene and EDPM washers, in roofs, walls etc complete all as specified and directed.
24S&F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet .50 mm thick of camouflage pattern having tensile strength of 550 mpa as in ridges, hips, valley gutter, drip or straight fastening etc fixed with self tapping screw etc complete all as specified and directed.
25S&F for plates (Plain or chequered ) channels of Fe410-W (Gde-E-250) quality -A, square cut or notched( ordinary or counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed.
26M&L for rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete sur faces even and smooth without using extra cement complete all as specified and directed.
27Supply only integral water proofing compound complete all as specified and directed.
28M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete sur faces even and smooth without using extra cement complete all as specified and directed.
29M&L for preparation of new plastered surfaces (external) of walls and applying two coats of exterior emulsion weather proof paint over a coat of primer complete all as specified and directed.
30M&L for preparing new surfaces (internal) and applying two coats of distempering walls with distemper oil emulsion, white or tinted complete over one coat chalk whitening including 1mm thk wall care putty, on plastered surfaces to internal walls complete all as specified and directed.
31M&L for Preparation of new steel Surfaces of any description, over 10cm in width or girth,of any description and applying two coats of synthentic enamel paint over a coat of red oxide primer complete all as specified and directed.
32M&L for Hardcore of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface for plinth protection/ under floor complete all as specified and directed.
33M&L for 100 mm thick plain cement concrete TypeD-2 1:4:8 (using 40 mm graded stone aggregate) as in paving/ under floor complete all as specified and directed.
34M&L for 100 mm thk plain cement concrete Type B-2, 1:2:4 (using 40 mm graded stone aggregate) in flooring complete all as specified and directed.
35Moorum/ red bajri filling in floors or pavings, laid in layers n.exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
36M&L for coioured vitrified Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
37M&L for glazed coloured ceramic tiles in vertical surface such as skirting,dado and risers to steps of siize 350x250x7mm / 600x 300 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match existing surface including 10mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
38M&L for 75 mm thk plain cement concrete Type C-2, 1:3:6 (using 40 mm graded aggregate)in plinth protection complete all as specified and directed.
39S&F for PVC Soffit system for False Ceiling / Wall Panelling purpose, to be screw fixed on a GI (GI-0.4mm) Channels or equivalent and standard hardware framework with interlocking between panels, Panel Size: 2700x300mm/; Panel colours : 4 shades of Wooden (Walnut / Winchestar oak / Oak /Golden Oak ) or 3 Shades of Uni Colour (White / Brown / Graphite); to be applied with finishing trims in same colour combination of soffit panel (J - Trim & T – Trim for False Ceilings. Panels to be in strict compliance with PN-EN ISO 527-1:2012 / PN-EN ISO 527-2:2012. Soffit Panels, 340 mm (effective usage area of 300mm) wide, 12 mm deep, 1.2 mm thick PVC sheets, plain / perforated / hidden perforated without non-woven acoustic textile. Panels feature a 11 mm wide flange for interlocking between the panels. Optionally the flange with 11 x 3 mm ventilation holes can be used to achieve a ventilated ceiling. Panels to be manufactured from Solid PVC surface Panels have a size of 2700x340mm; Effective size for Coverage: 2700x300mm. Panels to be installed using J – Trim along the periphery and to be coupled in longitudinal direction using T – Trim of the same colour combination of the panel for False Ceiling applications complete all as specified and directed.
40S&F for powder coated aluminium door frame with shutter of section 100mm x 45 mm thickness of sheet 16 gauge, paritially glazed and panelled lock rail / bottom rail of shutter 100mm x 45mm top raio 80mm x 45mm including necessary jointing cleats glazinging clips, rubber packing anodised aluminum including necessary fitting and aluminium mongeries i.s 150 mm long two nos aluminium handles 02 Nos, 200 mm long aluminium tower bolts hinges with each leaf, rubber gasket for securing the glass and 3 Nos 100 mm long butt hinges with each leaf with and including 5.5 mm thick tinted glass pvc panelling including mortice lock grills in glazed portion etc complete all as specified and directd.
41M&L for Double action floor spring hydraulically regulated made up of minimum 1.25mm thk alu alloy sheet foundation box, main body with stainless steel cover .governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directd.
42S&F for powder coated aluminium sliding windows two track with two sliding shutters with extrusions aluminium of following sections including jointing cleats, glazing clips, rubbr packaging, snap beading and other necessary builders hardware as required complete all as specified and directd. (A) FRAME:-(i) Top and side member for two track frame of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.784 kg/ mtr), Model No. 20829 of Jindal or equivalent as specified in PS.(ii) Bottom rail of frame for sliding of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.909 kg/ mtr), Model No. 20830 of Jindal or equivalent as specified in PS.(B) SHUTTER:-(i) Top and bottom rail of sliding shutter of size 40 mm x 18 mm x 1.5 mm (weight 0.547 Kg/ mtr), Model No. 20736 of Jindal or equivalent as specified in PS.(ii) Side of sliding shutter with handle and self locking arrangement, section of size 40 mm x 18 mm x 1.5 mm (weight 0.547kg/ mtr), Model No. 20738 of Jindal or equivalent as specified in PS.
43(C) Sliding shutter to be provided with 5.0mm thick sheet glass complete all as specified and directed.(D) Supply & Fix for 6.5 mm thick aluminium diamond grill with mill finished fixing on wall/wooden chowkhat/ aluminium frame with suitable size of aluminium 'U' channel and steel chromium plated, screw with rawel plug complete all as specified and directed with following details:- (i) Aperture size of aluminium grill 67 mm x 84 mm. (ii) Cord dimension 7 mm x 5.8 mm. (iii) Plate thickness 2 mm. (E) Supply & Fix for Galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm fixed with galvanised wire staples/ clip/ aluminium flat, complete all as specified and as directed.
44Demolition of cement concrete (unreinforeced) in floors and paving n.exc 15 cm thickness (Below or above the ground level) complete all as specified and directed.
45Demolition of brickwork or stone/boulder masonary, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and directed.
46M&L for preparation of old plastered surfaces(external) of walls and applying two coats of exterior emulsion weather proof paint over a coat of primer complete all as specified and directed.
47M&L for preparing old surfaces (internal) and applying two coats of distempering walls with distemper oil emulsion, white or tinted complete over one coat chalk whitening including 1mm thick wall care putty, on plastered surfaces to internal walls complete all as specified and directed.
48M&L for preparing old ceiling surfaces(internal) and applying two coats of distempering walls with distemper oil emulsion , white or tinted complete over one coat chalk whitening including 1mm thk wall care putty, on plastered surfaces of ceilings complete all as specified and directed.
49Taking down and refixing in other opening of chowkhats or frames exc 1.5 Sqm but n.exc 4.00 sqm with shutters (with out taking off shutters from the frame complete all as specified and directed.
50Taking down chowkhats or frames exc 1.5 sqm but exc 4.00 Sqm with shutters with out taking off shutters from the frame) complete all as specified and directed.
51M&L for factory made colour chequered cement concrete tile with pigment 20cm x 20cm x25mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments in floors over 15mm thk screed bed in cement mortar (1:4) complete all as specified and directed.
52M&L for 25 mm thick cement concrete type B-0 1:2:4 (12.5 mm graded stone aggregate) complete all as specified and directed.
53M&L for 100 mm thk plain cement concrete Type B-1, 1:2:4 (using 20mm graded aggregate)in sub base/ floors complete all as specified and directed.
54Dismantling plain or corrugated steel sheeting/PPG Sheeting,any gauge, thickness, including Nanital or similar pattern roof coverings complete all as specified and directed.
55Refixing of dismantled old PPG sheets shall be properly re-sized, suitably alinged and refixed at the required location using new self tapping screws, complete in all respectes complete all as specified and directed.
56M&L for 20mm thk Granite (of any type) work (Table rubbed and polished) in step, jambs, pillars, window- cills, cooking platform and like in cement mortar and like in cement mortar(1:4) including pointing in white cement (1:2) using marbel dust with admixture of pigment to match with shade of granite including moulding edges to round shape complete all as specified and directed.
57Surface dressing n.exc 15 cm deep in soft/ loose soil complete all as specified and directed.
58Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
59M&L for cement concrete Type C-1 1;3:6 (using 20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
60Excavating in post holes (or similar holes) each n.exc 0.5 Cum in soft/loose soil, getting out, returning,filling in and ramming earthor brilen rubble mixed with earth around, inlayers n.exc 25 cm, eatering and removing surplus soil to a distance n exc. 50mtr and making good surfacecomplete all as specified and directed.
61M&L for cement concrete tyoe D2 1:3:6 (40mm graded stone aggregate) in foundations,filling and mass concrete complete all as specified and directed.
62Taking down existing unserviceable roof treatment of any description including cement plaster, any thickness from roof surface ,cleaning of roof surface and preparaing it for further treatment and removing the debries / rubbish material from site complete all as specified and directed.
63M&L for preparation of plastered/concrete surfaces of Bldg roofs & tarraces,parapets, sunshades and exterior walls by brushing/brooming/blowing and applying HS Roof Kool & Seal fibre reinforeced liquid applied elastomeric waterproofing membrane ,impregneated with nano-fibre and formulated with PU-Acrylic Hybrid Polymer all as specified and directed .(a) Method of Application:-(i) The surface to be applied should be clean & sound ,free from any kind of contamination, dirt, tar/bitumen coating etc. (ii) Oil & Greese must be removed using degreasing solvents.(iii) Any damaged surface must be repaired by using crack fillers or polymer modified repair mortar using ADVANCED LATES PLUS as per Manufacture direction.(b) Angular fillets:-Hampering of junction of any right -angled corner( 50mm x50mm) & repairing the same using polymer modified mortar in1:4 ratio (cement sand) admixed with HS Advanced Latex Plus @3% by weight of cement.
64(c) Application of Primer:- Providing and applying single coat of HS PU Roof Kool& seal using brush/ roller after diluting the water in 40% ratio by volume (as per manufactures specification ) as the primer coat .Allow the primer to dry for 3-4 hours prior to waterproofing coating application.(d) Application of HS Roof Kool & Seal :- providing and applying two coats of HS Roof kool & Seal (Non -diluted )up to vertical wall 300 mm. Retention 4-5 hours. One component water based ,high soild, UV resistant hybrid Polyurethane membrane with 300% elongation,as per ASTM D412, for long lasting waterproofing SRI 107.
65HORIZANTAL WATERPROOFING:- (By using :-HS Roof Kool & Seal Product)Stage Dliution Tool Inter coat period Forced coverage (Composite system)Self priming 40% with Hard brush 3-4 Hrs potable water / RollerWater proofing Undiluted - 4-6 Hrs 1.0-1.1 sqm/ltr 1st coat (for 03 coats application)Water proofing Undiluted - 4-6 Hrs 1.0-1.1 sqm/ltr 2nd coat ( for 03coats application)The cured applied system shall achieve a total dry film thickness of 450-500 microns.VERTICAL WATERPROOFING:- (By using :-HS Roof Kool & Seal Product)Stage Dliution Tool Inter coat period Forced coverage (Composite system)Self priming 50% with Hard brush 3-4 Hrs potable water / RollerWater proofing Undiluted - 4-6 Hrs 1.65-1.85 sqm/ltr 1st coat (for 02coats application)
66M&L for rendering 20 mm thick plaster on concrete surfaces or on fair faces of brick work in cement mortar 1:3 finished even and smooth with out using extra cement complete all as specified and directed.
67Repair to RCC sunshades ,Chajjas , Balconies, Columns, Bands, Beams and similar RCC work at any position/height by sosmantling loose/ disintigrated portion dubbing out with Cement concrete 1:1.5:3,15 mm to 50mm thick using 6to 12 mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stiching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with 10 mm thk plastering in cement mortar :4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed.
68S&F for solid PVC wall lining consisting of 5mm thk Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
69S&F for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
70Demolition of wall and ceiling boards ( Fibre, pulp,insulation etc) or insulation boards/slabs/ blankets, any thickness , including cover fillets complete all as specified and directed.
71Providing and fixing false ceiling of designer tile ivory painted (high pressure steam cured ) of 4mm thick (as per IS: 14862) of size 595x595mm and any one of the design (cascade or electra) in true horizontal level. Suspended on inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms both side inclusive and black painted groove on all T webs)consisting of main T runner with suitably spaced joints to get required length and 15x32mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 15x32mm made of 0.3mm sheet 1200mm long spaecd between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 15x32mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturers instructions/literature. GI adjustable wire of 4mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 4mm dia GI wire shall be pre-painted with with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width, all complete all as specified and directed.
72S&F for collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles, stoppers and all necessary fitting and fixtures, including cutting, welding,drilling, grinding,alingment, anchored to the existing RCC/ Masonary structure with suitable holdfast,erected in position and securing runners with holdfast and brackets complete all as specified and directed.
73Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and seperating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and directed.
74Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed.
75Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed.
76Taking down carefully ceiling fan, sealing cable ends,dismantelling blades removing fan and blades for taking to store and refixing back to its original position and making good matching to the existing colour to the disturbed surface wall/ floors etc complete all as specified and directed.
77M&L for consealed conduit point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with all accessories (including cutting chases & making good the disturbed surface to its original specification) including modular metal flush box, including size 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DB's or common earth dolly complete all as specified and directed for the following :-
78Description all as per item No 92.00 here in before but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and directed.
79Description all as per item No 92.00 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and directed.
80Description all as per item No 92.00 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and directed.
81Description all as per item No 92.00 here in before but using 2.5 Sqmm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 2.5 Sqmm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and directed.
82S&Ffor ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
83S&F for modular swith 6/10 Amp one module complete all as specified and directed.
84S&F for Modular socket 6 Amp 2/3 Pin combined 2 module 230 volt flush type complete all as specified and directed.
85S&F for modular switch 1 way 16 Amps, 1 module, 230 volt complete all as specified and directed.
86S&F modular socket 1 way 6/16 Amps, 3/3 pin combined, 2 module, 230 volt complete all as specified and directed.
87S&F for Modular type electronic fan regulator 2 module, 5 speed complete all as specified and directed.
88S&F for white cover plate with frame 3 module complete all as specified and directed.
89S&F for white cover plate with frame 6 module complete all as specified and directed.
90S&F for white cover plate with frame 8 module complete all as specified and directed.
91S&F for LED lights fitting 1 X 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make Crompton Cat Part No TCS-108-20-65-SL-DP-NWH / Havells Cat Part No LHEXAZP7IN1W020.
92S&F for bulk head luminaire environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge -lit LED luminaire comprising of high brightness LEDs 10 watt, 230 volts, 50 Hz including lamp, connection wire complete all as specified and directed. Make :- Havells Cat Part No :-RUGBYGENXFTS10WLED865SSYMBOPC 9405 / Crompton Cat Part Number :- TIS-303-10-57-SL-DP-NWH.
93S&F for Recess mounted Slim Compact Aluminium Die-cast, Edge lit Panel, Round Fixture with Opal Diffuser and Separate Electronic Driver 15 Watt, 230 Volt, 50 Hz including Lamp, Connection Wire, suitable Modification in existing False Ceiling Board and Connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size and Length complete all as specified and directed.Make : Crompton Cat Part No :-CDR-205-15-57-SL-NWH.
94S&F for LED Building Security Light Fitting 25 Watt, 230 Volt AC,with suitable bracket and clamp, nut bolts, Outdoor type with High Pressure Die Cast Aluminum Housing and Heat Resistant with Driver, Lamp, Surge Protection Device, and Corrosion Resistant including Thermal Management in Multipole Optics, having IP 65/66 Protection and Connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size and Length complete all as specified and as directed. Make : Crompton Cat Part No. ERP-427-25-57-HL2-LM-NBK.
95Hanging only ceiling fan (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
96S&F for copper wound ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V,1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Energy efficient, five star rated, with brushless direct current motor (BLDC) complete with mounting arrangment as per site requirement and connecting wire up to nearest ceiling rose in flexible PVC pipe complete all as specified and directed.
97S&F for wall fan size 400 sweep, speed 1350 RPM, single phase AC 230Volts complete all as specified and directed.
98Taking Down TPN DB fro existnig wall, disconnecting cable, earthing and wiring any and refixing it new propsed site with complete MCCB, MCB, Door with complete acesserores complete all as specified and directed.
99S&F for sheet metal enclosure, MCB DB, double door, single pole & neutral, 12 way, 230 volts, 50 Hz with suitable bus bar, neutral link, earth link complete all as specified and directed.
100S&F for Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/ lsolators complete all as specified and directed.
101S&F for MCB SPN 32 Amps, 230 volts, C - curve, 10 kA complete all as specified and directed.
102S&F for MCB SP 10 to 32 Amps, 230 volts, C curve, 10 kA complete all as specified and directed.
103M&L for sub main wiring with 2 run of 2.5 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit complete all as specified and directed. Note :-(i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’.(ii) Two run of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length).
104S&F for concealed submain wiring with 2 X 4.0 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade alongwith 1 X 4.0 sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade for continuous earth wire complete drawn through and including PVC conduit, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed.
105S&F for concealed submain wiring with 2 X 6.0 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade alongwith 1 X 6.0 sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade for continuous earth wire complete drawn through and including PVC conduit, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed.
106M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6.3mm thick electrode and 4mm galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mir deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to Gl wire 4mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board /DB/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm Gl tubing light grade for protection including testing on completion all as shown in Electrical Plate No 3 of SSR Part-l complete all as specified and directed.
107S&F for Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU) of 1.5 TR with 5 Star BEE Rating capacity. Inverter Type complete all as specified and directed.
108Supplying, installing, commissioning of Voltage stabilizer for utomatic operation, single phase neturally air cooled, indoor type & designed for input variation 130-280 V with output voltage stabilized at 230 Volts with accuracy of +- 2.5% and capacity 5 KVA complete all as specified and directed.
109S&F for single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 'C' Curve, 10 KA including all accesories complete all as specified and directed.
110Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 10 sqmm 4 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc including taking down old cable complete all as specified and directed.
111Supply, fixing/ laying, connecting and commissioning LT underground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable with multistranded aluminium conductor, 50 Sqmm, 3.5 core, 1100 Volts grade laid in trenches/ on wall/ poles/ ducts/ pipe including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) including taking down old cable complete all as specified and directed.Note: Earth work shall be measured & paid separately.
112Excavation in trenches in soft/ loose soil n.exc 1.5 metre wide and n.exc 1.5 m in depth and getting out for taking up / laying under ground electric cable complete all as specified and directed.
113Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed.
114Supply and laying sub class B bricks of size 23cm x 115 cm x 7.5cm for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and directed.
115M&L for 40 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and directed.
116Demolition of cement concrete unreinforced, in ground floor or pavings below or above ground level from foundation of filtration plant including removal of debris from site complete all as specified and directed.
117M&L for PCC 1:2:4 type B-1 using 20 mm graded mechanically crushed stone aggregates as in foundation, sub base or mass concrete complete all as specified and directed. Material and labour laying well burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58653756
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.50 Lakhs
LAST DATE 10-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Addition/Alteration Of Building For Hrm And Accts Section At Af Stn Mohanbari
Basic Detail
Tender No 8001/873/E8
Bidding Type Tender
Location
City Dibrugarh
State Assam
Key Dates
Publish Date 21 Nov 2026
Submission Date 10 Dec 2026
Open Date 11 Dec 2026
Finance
Tender Value 43.50 Lakhs
Tender Fee 500
EMD 87000
Exemption Available
Document List
BOQ_897344.xls
ccf710ad-494d-4517-b821-4e5cd818fc80.html
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Dec 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_897344.xls

html

ccf710ad-494d-4517-b821-4e5cd818fc80.html

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender