Tender For Supply Installation Testing and Commissioning of 30 Kva And 20 Kva Online Double Conversion Ups For Tiir Auditorium And Ppa In Nit, Rourkela
Tender Value
Ref. Documents
Estimated cost
Bid Submission
14 Dec 2026
21 days left
EMD
48000
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sundargarh → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of 30 Kva And 20 Kva Online Double Conversion Ups For Tiir Auditorium And Ppa In Nit, Rourkela
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing and Commissioning of 30 kVA/30 kW online double conversion UPS having 3ph. 415 V AC, 45-55Hz Input & 415V 50Hz 3ph Output in N+1 mode with load, Input Voltage range 320V AC to 460V AC, WITH preferable INBUILT ISOLATION Transformer ans SNMP, inbuilt phase reversal correction, with battery temperature censor, with protection < 1KV having Certification with CE/RoHS & PEP Compliance (IEC 62040-1, IEC 62040-2, IEC 62040-3)VRLA - AGM sealed lead acid maintenance free battery with UP OF 30 MINUTES along with required DC CABLE , BREAKER, LINKS AND MS RACK FOR BATTERY HOUSING.Make: NUMERIC of Legrand / APC of Schneider / Emersion of VertiveBattery : 12V/65AH/40nos. (Make: EXIDE)The price should include the cost of delivery at NIT Rourkela alongwith installation charges. THREE years WARRANTY on both UPS and both batteries banks must be provided. |
| 2 | Providing comprehensive AMC of the above for THREE years after the completion of three year WARRANTY period. |
| 3 | 1st Year after completion of warranty period |
| 4 | 2nd Year after completion of warranty period |
| 5 | 3rd Year after completion of warranty period. |
| 6 | Supply, Installation, Testing and Commissioning of 20 kVA/20 kW online double conversion UPS having 3ph. 415 V AC, 45-55Hz Input & 415V 50Hz 3ph Output in N+1 mode with load, Input Voltage range 320V AC to 460V AC, WITH preferable INBUILT ISOLATION Transformer ans SNMP, inbuilt phase reversal correction, with battery temperature censor, with protection < 1KV having Certification with CE/RoHS & PEP Compliance (IEC 62040-1, IEC 62040-2, IEC 62040-3)VRLA - AGM sealed lead acid maintenance free battery with UP OF 30 MINUTES along with required DC CABLE , BREAKER, LINKS AND MS RACK FOR BATTERY HOUSING.Make: NUMERIC of Legrand / APC of Schneider / Emersion of VertiveBattery : 12V/75AH/20nos. (Make: EXIDE)The price should include the cost of delivery at NIT Rourkela alongwith installation charges. THREE years WARRANTY on both UPS and both batteries banks must be provided. |
| 7 | Providing comprehensive AMC of the above for THREE years after the completion of three year WARRANTY period. |
| 8 | 1st Year after completion of warranty period |
| 9 | 2nd Year after completion of warranty period |
| 10 | 3rd Year after completion of warranty period. |
| 11 | Supply, Installation, testing, Commissioning of Maintenance Free Chemical Gel Earthing - Dual Pipe (GI) Technology 3000 mm long, outer dia 80mm, strip size 50 mm, Terminal (50x10) mm permenantly sealed at both the ends with the lead terminal at the top duly filled with metallic conducting compound permenantly sealed at both the ends along with 50 kgs of grounding minerals. The earth pit chamber shall be of heavy duty Polyplastic earth pit cover. |
| 12 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as directed by EE (Electrical) |
| 13 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 14 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 15 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 16 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 17 | 6 way (8 + 18), Double door |
| 18 | Supply and laying of 4 core 16 sq mm unarmoured copper cable on surface |
| 19 | Supply & Installation of Insulation Resistance Tester (FLUKE 1507) alongwith Fluke C101 Hard Case and Fluke TL81A Deluxe Electronic Test Lead Kit Triple pole and neutral Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysDec 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender