Public Administrative Department Local Bodies Closing in 10 days TDR #58652386

Tender For Shifting Of Existing Ht Line Cum Lt Line Towards Construction Of Major Storm Water Drainage Work At Nh-16, Iskcon Opposite & Renault Showroom, Paikanagar, Bhubaneswar

Issued by Local Bodies · Khordha, Odisha
Tender Value
11 Lakhs
Estimated cost
Bid Submission
02 Dec 2026
10 days left
EMD
11100
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Shifting Of Existing Ht Line Cum Lt Line Towards Construction Of Major Storm Water Drainage Work At Nh-16, Iskcon Opposite & Renault Showroom, Paikanagar, Bhubaneswar

BOQ

Name of Work:- Shifting of existing HT line cum LT line towards construction of major storm water drainage work at NH-16, ISKCON Opposite & Renault Showroom, Paikanagar, Bhubaneswar
Sl. No. Item Description
1Materials for 11 KV Cut Point with 180 Degree Angle (Part-A)WPB (GI) Pole 160X152 (11Mtr. Long, 30.44Kg/ Mtr.) (Total Pole Weight with Base Plate & Stiffner= 334.84 Kg+10.74 Kg=345.58 Kg)
2Straight cross arm 100X50X6 mm, 9.56Kg/Mtr., each channel (GI) length 1.2 Mtr., 2 no's. channel (GI)required= (2X9.56X1.2)
3Fish plate (GI) 50X6 mm, 2.36 Kg/ Mtr., each 0.280 Mtr. length, 8 no's required= (8X2.36X0.280)
4Straight cross arm 100x50x6 mm, 9.56Kg/Mtr., each channel (GI) length 0.306 Mtr., 2 no's. channel (GI) required= (2X9.56X0.306)
5Danger Plate, 1 no's
6Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
7GI barbed wire anticlimbing device 3 Kg. Per support
8Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4no's = (4x0.59x0.510)
911 KV pin insulator polymer
10H W fitting (B&S) 70 KN, 3 Bolt
11Disc insulator (B&S) 70 KN polymer
12Earthig of support (Coil type)
13No-8 GI wire (Dia 4.6 mm) 0.131 KG/ Mtr.-2 Mtr. For connecting pole with coil earthing
14NON METALLIC TIES-11KV 100SQMM CVRD AAAC
15IPC for 100 sq.mm AAA conductor (For covered conductor)-11 KV
16Spike (GI) (using 50x6mm Flat (GI) welded with 8 mm square bar) 2 Nos of spike per set in each pole)
17GI Nut, Bolt & Washer of different sizes (3.55 Kg each Cut pole)
18Black Paint(GIS Numbering & Zebra Stripping)
19Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
20Contingency@3%
21Tools & Plants@2%
22Transportation @ 7.5%
23Erection charges @ 5% on Trf//Breaker/ WPB/ H-Pole
24Erection charges @ 10% (except Trf/Breaker/WPB/H-Pole/HT stay set/GI Pipe/PSC pole/GI Pipe earthing)
25Concreting ratio 1:1.5:3 (M-20 Grade) (500mmX500mmX1800mm) =0.45Cum. (Per Pole)
26Couping ratio 1:1.5:3 (M-20 Grade)with dimension ( 500X500X450)= 0.1125 Cum.(Per Pole)
27MATERIALS FOR 11 KV Pin Points With 90 Degree Angle (Part-B)WPB (GI) Pole 160X152 (11Mtr. Long, 30.44Kg/ Mtr.) (Total Pole Weight with Base Plate & Stiffner= 334.84 Kg+10.74 Kg=345.58 Kg)
28Straight cross arm 100X50X6 mm, 9.56Kg/Mtr., each channel (GI) length 1.2 Mtr., 4 no's. channel (GI)required= (4X9.56X1.2)
29Fish plate (GI) 50X6 mm, 2.36 Kg/ Mtr., each 0.280 Mtr. length, 16 no's required= (16X2.36X0.280)
30Straight cross arm 100x50x6 mm, 9.56Kg/Mtr., each channel (GI) length 0.306 Mtr., 4 no's. channel (GI) required= (4X9.56X0.306)
31Danger Plate, 1 no's
32Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510)
33GI barbed wire anticlimbing device 3 Kg. Per support
34Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4no's = (4x0.59x0.510)
3511 KV pin insulator polymer
36H W fitting (B&S) 70 KN, 3 Bolt
37Disc insulator (B&S) 70 KN polymer
38Earthig of support (Coil type)
39No-8 GI wire (Dia 4.6 mm) 0.131 KG/ Mtr.-2 Mtr. For connecting pole with coil earthing
40NON METALLIC TIES-11KV 100SQMM CVRD AAAC
41IPC for 100 sq.mm AAA conductor (For covered conductor)-11 KV
42Spike (GI) (using 50x6mm Flat (GI) welded with 8 mm square bar) 2 Nos of spike per set in each pole)
43HT Stay clamp, 50X8 mm. flat 3.14Kg/ Mtr, 0.551 Mtr length 2 no's qty required (1 Pair)
44HT Stay Set (Complete)
45HT Stay Insulator Type-C
467/10 SWG Stay Wire 15kg/ stay
47GI Nut, Bolt & Washer of different sizes (7.433 Kg each Cut pole)
48Black Paint(GIS Numbering & Zebra Stripping)
49Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background
50Contingency@3%=
51Tools & Plants@2% (Except HT Stay Set)
52Transportation @ 7.5% =
53Erection charges @ 5% on Trf//Breaker/ WPB/ H-Pole
54Erection charges @ 10% of (except Trf/Breaker/WPB/H-Pole/HT stay set/PSC pole/ GI pipe earthing)
55Fixing of complete 11KV line Complete stay set includes1) Turn Buckle Assembły2) Stay Rod & Stay plate3) Stay Insulator 4) Stay Wire. 5) Stay clamps with Nuts & bolts BA will do the excavation including excavation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmX 500mmX 800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.
56Concreting ratio 1:1.5:3 (M-20 Grade) (500mmX500mmX1800mm) =0.45Cum. (Per Pole)
57Couping ratio 1:1.5:3 (M-20 Grade)with dimension ( 500X500X450)= 0.1125 Cum.(Per Pole)
58MATERIALS FOR 11 KV Pin Points With WPB (Part-C)100 SQ.MM. AAAC XLPE Covered Conductor-11 kV
59Contingency@3%
60Tools & Plants@2%
61Transportation @ 7.5%
62Erection charges @ 10% of H (except Trf/Breaker/WPB/H-Pole/HT stay set/ GI Pipe/ PSC pole/ GI pipe earthing)
63Installation of 100 KVA, 11/0.4 KV DSS without transforme-1 no. (Part-D)WPB (GI) Pole 160X152 (11Mtr. Long, 30.44Kg/ Mtr.)-DP (Total Pole Weight with Base Plate & Stiffner= 334.84 Kg+10.74 Kg=345.58 Kg)
64Top Channel Gl 100 X 50 X 6 mm. (3000 mm long) (9.56Kg/Mtr., 2 no's) (Each 2x3x9.56= 57.36 Kg)
65Fish Plate 50x6 mm., 2.36 Kg/Mtr., each 0.280 Mtr. length, 6 no's required = (6x2.36x0.280)
66M.U Channel GI 75x40x4.8 mm (3000 mm long)(7.14Kg./ Mtr., 2 no's) (Each 2x3x7.14 = 42.84 Kg)
67AB Switch Mounting Channel (GI) 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 nơ's) (Each 2x3x7.14 = 42.84 Kg)
68AB Switch Side Şupport Channel 100X50X6 mm, 9.56 Kg/Mtr., each channel length 0.35 Mtr., 2 no's channel (GI) required =9.56x2x0.35)
69Channel (GI) Support for down Pipe 75X40X4.8mm., 7.14Kg/Mtr., each channel length 0.8 Mtr., 1 no's channel required = (7.14x0.8x1)
70HG/DO Fuse Mounting Channel (GI) 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg/Mtr., 2 no's) (Each 2x3x7.14= 42.84 Kg)
71Cantilever Support Channel (GI) 75x40x4.8 mm GI Channel (810 mm long, 2 no's) (7.14Kg./Mtr., 2 no's) (Each 2x0.810x7.14= 11.57Kg)
72Cantilever Support Angle (GI) 50x50x6 mm GI (1282 mm long) (4.5Kg./Mtr., 2 no's) (Each 2x1.282x4.5= 11.54Kg)
73Transformer Base GI Channel 100X50X6 mm (3000 mm long) (9.56Kg./Mtr, 2 no's.) (Each 2x3x9.56= 57.36 Kg)
74Transformer Base Support GI Channel 100X50X6 mm (515 mm long) (9.56Kg./Mtr., 2 no's) (Each 2x0.515x9.56= 9.85 Kg)
75Transformer Belting Angle 50x50x6 mm GI (3000 mm long)(4.5Kg./Mtr., 2 no's) (Each 2x3x4.5 Kg)
76Transformer Belting Support Angle 50x50x6 mm GI (580 mm long) (4.5Kg./ Mtr.,2 No's) (Each 2x0.580x4.5= Kg)
77LTDB Mounting Angle 50x50x6 mm GI (1000 mm long) (4.5Kg./Mtr, 2 no's) (Each 2x1x4.5 Kg)
7850x6mm GI Flat for earthing, 2.36 Kg/Mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. for LA and 2.5 Mtr. for raising, 11 Mtr. for AB switch, 2.8 Mtr. for HG Fuse, 5x2 Mtr. for DTR Neutral, (1.3+4.5) Mtr. for DTR Body, 0.500 Mtr. for LTDB & AB Switch operating handle, 3 Mtr. for Fencing) (Each 65.6x2.36= 154.81 Kg)
79LT Distribution Box with MCCB, Aluminium Busbar of 2 Bay with kit kat fuse for 100 KVA S/S
8055 mm² AAAC XLPE Covered Conductor
814CX150 mm² LT XLPE Cable (Armoured)- For 100 KVA Trf
821.1 kv 4core, 150 sqmm, XLPE insulation armoured-Aluminium UG cable from LTDB to Pole
83AB Switch(11KV, 200A, 3pole, 50Hz)
84H.G.Fuse( 11KV, 200A, 3Pole)
85WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR
86POLYCARBONATE BIRD GUARD
87Disc insulator (B&S)70 KN polymer
88HW fiting (B&S)70KN(3 Bolted)
89Lightning Arrester(12KV, 10KA) Station Class 2
9011KV pin insulator polymer
91HT Stay set complete
92HT stay Clamp (1.9Kg/ Pair)
93HT stay insulator TYPE-C
947/10 SWG GI stay wire, Grade -2 (15Kg./ Set)
9540 mm Nominal bore Gl pipe (medium gauge) earthing device with 3 Mtr. long
96GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)
97GI Barbed wire/Anticlimbing device (3Kg/Pole)
98Back Clamp for anticlimbing device 25x3 mm. flat (GI), 0.59Kg/ Mtr. Flat of 0.510 Mtr. length & 8 no's =(8x0.59x0.510)
99Danger plate 11kv
100Back Clamp for Danger plate 25x3 mm. flat, 0.59Kg/Mtr. Flat of 0.510 Mtr. length 2 no's=(2x0.59x0.510)
101Name plate
102Structure Numbering and Marking(i)Yellow Colour Paint for Backaround (GIS Numbering & Zebra Stripping) for Background
103(ii)Black Colour Paint for numbering (GIS Numbering & Zebra Stripping) for Background
104Contigency @ 3%
105Tools & Plants@2% (Except Stay/Earthing/Cable)
106Transportation @ 7.5%
107Erection charges @ 5% on Trf/Breaker/WPB/H-Pole
108Erection charges @ 10%(except Trf/Breaker/WPB/H-Pole/HT stay set/GI pipe/PSC pole/GI pie earthing))
109Concreting ratio 1:1.5:3 (M-20 Grade) (500mmX500mmX1800mm) = 0.450Cum. (Per Pole) (For WPB Pole)
110Couping ratio 1:1.5:3 (M-20 Grade) (500mmX500mmX450mm) = 0.113 Cum. (Per Pole)
111PCC ration 1:3:6 (M-10 Grade) For DSS Area (5x3x0.1)= 1.5 Cum
112Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6 (M-10 Grade) size (900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set, stay wire, stay nsulator.
113Construction Earthing chamber including installation of earthing pipe. Making earthing chamber including excavation, soil treatment with bentonide powder, calculation of earth resistance, including installation of 3Mtr. GI Pipe 40mm/50mm including welding of GI flat around pipe.
114Laying of 4 C x 150 mm² LT XLPE Cable
115SITC and Erection of GI Fencing with Gate
116Supply of AL Lugs suitable for 150 sq mm cable/conductor, Crimping with cable and Fixing/connecting include supply and erection of PVC Tape as per voltage requirement.
117Supply and erection of double Compression Flameproof Tyре Glanding for armored Cable 3.5/4C 120-185sqmm including making hole in Base plate and dressing of cable along with vermin proofing properly .Supply to be done as per TPCODL Spec and approved make dowells.
118Inspection Fee of Transformer (100 KVA to 1000 KVA)
119Inspection Fee of LV Cable
120Inspection Fee of Drawing Checking and Approval
121MATERIALS FOR LT AB Cable Line (Part-E)LT Accessories with Eye hook and Clamp4Cx70 mm² (P)+1Cx70 mm²(M)+1CX16 mm²(Street Light) (LT AB Cable)
1224 WAY SERVICE Distb. box with kit kat fuse and Aluminium bus bar.
123INSU. SHACKLE LT WITH METAL 100X115 MM
124GI STRAP SHACKLE INSU (N+B)
125Insulated piercing connector.Type-A-main 50 to 150 sq.mm & Tap-50 to 150 sq.mm.
126Contigency @ 3%
127Tools & Plants@2% (Except LT Stay set/GI pipe Earthing)
128Transportation @ 7.5%=
129Erection Charges @ 10% (except Trf/Breaker/WPB/ H-Pole/HT Stay set/GI Pipe/ PSC Pole/GI Pipe earthing) =
130Dismantling Material (Part-F)Dismantling of 09/11 Mtr. Joist/WPB Pole- 116X100 mm
131Dismantling of 9/8 Mtr. PCCJoist Pole
132Dismantling of 11 kV Pin insulator with pin
133Dismantling of 11 kV Disc insulator with Hardware
134Dismantling/ Removal of MS Channel from Double Pole Structure/ Pole
135Dismantling of existing 11/0.4kV, 33/0.4KV, 500kVA ThreePhase Distribution Transformer including removal ofHT/LT leads, earth connections and unloading by crane ifrequired.
136Dismantling of ACSR/AAAC 34/ 55 mm2 from overhead line
137Dismantling of various size LT AB Cable
138Dismantling of 11 kV /33KV GO/AB Switch/Isolator/DDfuse/fuse set
139Dismantling of the GI wire 7/8, 7/10 SWG etc
140Dismantling of coil earthing
141Dismantling of stay set complete
142Dismantling of stay insulator (Guy Insulator)
143Dismantling of Danger Board
144Dismantling of Lightening Arrester (LA) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58652386
AUTHORITY Local Bodies
TENDER VALUE 11 Lakhs
LAST DATE 02-12-2026
Authority
Authority Name Municipal Bodies
Work Description Tender for Shifting Of Existing Ht Line Cum Lt Line Towards Construction Of Major Storm Water Drainage Work At Nh-16, Iskcon Opposite & Renault Showroom, Paikanagar, Bhubaneswar
Basic Detail
Tender No BMC-EE-Tender Cell-96/2026-27 dt. 18.11.2026
Bidding Type Tender
Location
City Khordha
State Odisha
Key Dates
Publish Date 21 Nov 2026
Submission Date 02 Dec 2026
Open Date 02 Dec 2026
Finance
Tender Value 11 Lakhs
Tender Fee 6000
EMD 11100
Exemption Available
Document List
BOQ_622677.xls
DTCN_96.pdf
fd982bbf-7de7-46f4-931f-89e547db83de.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Dec 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_622677.xls

pdf

DTCN_96.pdf

html

fd982bbf-7de7-46f4-931f-89e547db83de.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender