Bids Are invited for Custom Bid For Services - ---- - Supply Of 11 Kv Line Material As Per Relevant Iss , F-Bracket , Barbed Wire , Clamp With N&B , Danger Board With Clamp , Pg Clamp , Number Plate , Aluminium Binding Wire , Ms Dropper Chanel 100X50
Tender Overview
Project Description
Bids Are invited for Custom Bid For Services - ---- - Supply Of 11 Kv Line Material As Per Relevant Iss , F-Bracket , Barbed Wire , Clamp With N&B , Danger Board With Clamp , Pg Clamp , Number Plate , Aluminium Binding Wire , Ms Dropper Chanel 100X50x2000 Mm , Top Channel 125X65x2240 Mm With Clamp , Ms Cross Bracing Angle , T Off Channel , Allunimum Lug Barrel Off Size , Henely Type Tailless Unit Protection Cubical Panel 500 A, 650 V For 400 Kva Dt , Base Angle , Ms X Arm 65X65x6 Mm V Type , Erection Work , Safe Carriage Of Line Material From Store Center Etah / Nearest 33/11 Kv S/S To Direct Pit Site In Distance Range 0 To 30 Km. Including Loading And Unloading At Both Side. , Safe Carriage Of 11 Mtr Long St Pole From Store Center Etah / Nearest 33/11 Kv S/S To Direct Pit Site In Distance Range 0 To 30 Km. Including Loading And Unloading At Both Side. , Safe Carriage Of 11 Kv Vcb From Store Center Etah / Nearest 33/11 Kv S/S To Direct Pit Site In Distance Range 0 To 30 Km. Including Loading And Unloading At Both Side. , Safe Carriage Of 400 Kva Tf From Electricty Store Center Etah/Nearest 33/11 Kv S/S To Direect Pit Site In Distance Range 0 To 30 Kms. Including Loading And Unloading At Both Side. , Erection Of 11 Mtr St Pole As Single Support Including Fixing Of All Ht/Lt Accessories Etc. Complet, Pole Should Be Grouted Properly As Per Dvvnl/Respo Norms. , Erection Of 11 Mtr St Pole As Double Pole Including Fixing Of All Ht/Lt Accessories Etc. Complet, Pole Should Be Grouted Properly As Per Dvvnl/Respo Norms. , Construction Of 400 Kva T/F Plinth For Size 2X2x1.5 M With The Help Of First Class Brick And Masonary In The Ratio 1:4 Cement & Sand Coarse. Filling The Structure Completely As Per Norms With Rcc Top 1:2:4 Cement, Sand Coarse And Stone Grit With Ms Bar And Ms Channel For Resting Transformer Wheel (100X50x6mm) And Plaster. All Material Shall Be Provided By The Contractor. , Net Fencing Shall Be 1150*1200 Mm Made Of 35*35 Mm Ms Angle Covered By Expended Metal 14 Swg Up To Full Height 1200 Mm Duly Steftened By Ms Flat By An 8 Swg Dia Bolt & Nut , Installation Of 400 Kva T/F On Newly Constructed Plinth In Proper Alignment Direction & Making Ht/Lt Connection All Cost Of Labour And T&P Which Required For Completion Of Work , Pipe Earthing Up To Water Level Of 400 Kva Medium Power Transformers , Laying, Sagging Stringing, Binding, Jumpering & Fixing Of All Accessories Etc Of Following Conductor On The Newly/Old Erected Pole As Per Respo Manual And As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T & P, Carrier Etc Required For Proper Completion Of Work. , Acsr Rabbit Conductor , 11 Kv Xlpe Cable 3X120 Sq Mm , Lt Xlpe Cable Al 1X400/2X240 Sq Mm , Danger Board With Clamp , Pg Clamp , Number Plate , Installation Of 11 Kv Vcb O/G , O/D Jointing Kit Suitable For 3X120 Sq Mm Xlpe Cable , I/D Jointing Kit Suitable For 3X120 Sq Mm Xlpe Cable , Earthing Complete , Stay Set Complete , Gi Pipe 6 Dia , Installation Of Henely Type Tailless Unit Protection Cubical Panel 500 A, 650 V For 400 Kva Dt , Fixing Of Red Oxide Paint , Fixing Of Allunimum Paint , F-Bracket , Fixing Of Allunimum Lug Barrel Off Size , Installation Of Ct/Pt Pole Mounting Unit , Grouting Of Main Metering Cubicle Inside The Meter Room Alongwith Termination Of 11 Kv Cable.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supply of 11 KV Line Material as per relevant ISS | Supply of 11 KV Line Material as per relevant ISS |
| 2 | F-Bracket | F-Bracket |
| 3 | Barbed wire | Barbed wire |
| 4 | Clamp with N&B | Clamp with N&B |
| 5 | Danger Board with Clamp | Danger Board with Clamp |
| 6 | PG Clamp | PG Clamp |
| 7 | Number Plate | Number Plate |
| 8 | Aluminium Binding Wire | Aluminium Binding Wire |
| 9 | MS Dropper Chanel 100x50x2000 mm | MS Dropper Chanel 100x50x2000 mm |
| 10 | Top Channel 125x65x2240 mm with Clamp | Top Channel 125x65x2240 mm with Clamp |
| 11 | MS Cross Bracing Angle | MS Cross Bracing Angle |
| 12 | T off Channel | T off Channel |
| 13 | Allunimum Lug Barrel off size | Allunimum Lug Barrel off size |
| 14 | Henely Type Tailless Unit Protection Cubical Panel 500 A, 650 V for 400 KVA DT | Henely Type Tailless Unit Protection Cubical Panel 500 A, 650 V for 400 KVA DT |
| 15 | Base Angle | Base Angle |
| 16 | MS X Arm 65x65x6 mm V Type | MS X Arm 65x65x6 mm V Type |
| 17 | Erection Work | Erection Work |
| 18 | Safe carriage of line material from store center Etah / nearest 33/11 KV S/S to direct pit site in distance range 0 to 30 Km. including loading and unloading at both side. | Safe carriage of line material from store center Etah / nearest 33/11 KV S/S to direct pit site in distance range 0 to 30 Km. including loading and unloading at both side. |
| 19 | Safe carriage of 11 Mtr Long ST pole from store center Etah / nearest 33/11 KV S/S to direct pit site in distance range 0 to 30 Km. including loading and unloading at both side. | Safe carriage of 11 Mtr Long ST pole from store center Etah / nearest 33/11 KV S/S to direct pit site in distance range 0 to 30 Km. including loading and unloading at both side. |
| 20 | Safe carriage of 11 KV VCB from store center Etah / nearest 33/11 KV S/S to direct pit site in distance range 0 to 30 Km. including loading and unloading at both side. | Safe carriage of 11 KV VCB from store center Etah / nearest 33/11 KV S/S to direct pit site in distance range 0 to 30 Km. including loading and unloading at both side. |
| 21 | Safe Carriage of 400 KVA TF from Electricty store center Etah/nearest 33/11 KV S/S to direect Pit site in distance range 0 to 30 Kms. Including loading and unloading at both side. | Safe Carriage of 400 KVA TF from Electricty store center Etah/nearest 33/11 KV S/S to direect Pit site in distance range 0 to 30 Kms. Including loading and unloading at both side. |
| 22 | Erection of 11 mtr ST Pole as single support including fixing of all HT/LT accessories etc. complet, pole should be grouted properly as per DVVNL/RESPO norms. | Erection of 11 mtr ST Pole as single support including fixing of all HT/LT accessories etc. complet, pole should be grouted properly as per DVVNL/RESPO norms. |
| 23 | Erection of 11 mtr ST Pole as Double Pole including fixing of all HT/LT accessories etc. complet, pole should be grouted properly as per DVVNL/RESPO norms. | Erection of 11 mtr ST Pole as Double Pole including fixing of all HT/LT accessories etc. complet, pole should be grouted properly as per DVVNL/RESPO norms. |
| 24 | Construction of 400 KVA T/F plinth for size 2x2x1.5 M with the help of first class brick and masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely as per norms with RCC top 1:2:4 cement, sand coarse and stone grit with MS Bar and MS channel for resting transformer wheel (100x50x6mm) and plaster. All material shall be provided by the contractor. | Construction of 400 KVA T/F plinth for size 2x2x1.5 M with the help of first class brick and masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely as per norms with RCC top 1:2:4 cement, sand coarse and stone grit with MS Bar and MS channel for resting transformer wheel (100x50x6mm) and plaster. All material shall be provided by the contractor. |
| 25 | Net Fencing Shall be 1150*1200 mm made of 35*35 mm MS Angle covered by expended metal 14 SWG up to full Height 1200 mm duly steftened by MS flat by an 8 SWG dia bolt & nut | Net Fencing Shall be 1150*1200 mm made of 35*35 mm MS Angle covered by expended metal 14 SWG up to full Height 1200 mm duly steftened by MS flat by an 8 SWG dia bolt & nut |
| 26 | Installation of 400 KVA T/F on newly constructed Plinth in proper alignment direction & making HT/LT connection all Cost of labour and T&P which required for completion of work | Installation of 400 KVA T/F on newly constructed Plinth in proper alignment direction & making HT/LT connection all Cost of labour and T&P which required for completion of work |
| 27 | Pipe earthing up to water level of 400 KVA medium Power Transformers | Pipe earthing up to water level of 400 KVA medium Power Transformers |
| 28 | Laying, sagging stringing, binding, jumpering & fixing of all accessories etc of following conductor on the newly/old erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc required for proper completion of work. | Laying, sagging stringing, binding, jumpering & fixing of all accessories etc of following conductor on the newly/old erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc required for proper completion of work. |
| 29 | ACSR Rabbit Conductor | ACSR Rabbit Conductor |
| 30 | 11 KV XLPE Cable 3x120 sq mm | 11 KV XLPE Cable 3x120 sq mm |
| 31 | LT XLPE Cable AL 1x400/2x240 sq mm | LT XLPE Cable AL 1x400/2x240 sq mm |
| 32 | Danger Board with Clamp | Danger Board with Clamp |
| 33 | PG Clamp | PG Clamp |
| 34 | Number Plate | Number Plate |
| 35 | Installation of 11 KV VCB O/G | Installation of 11 KV VCB O/G |
| 36 | O/D Jointing Kit suitable for 3x120 sq mm XLPE Cable | O/D Jointing Kit suitable for 3x120 sq mm XLPE Cable |
| 37 | I/D Jointing Kit suitable for 3x120 sq mm XLPE Cable | I/D Jointing Kit suitable for 3x120 sq mm XLPE Cable |
| 38 | Earthing Complete | Earthing Complete |
| 39 | Stay Set Complete | Stay Set Complete |
| 40 | GI Pipe 6\\" Dia | GI Pipe 6\\" Dia |
| 41 | Installation of Henely Type Tailless Unit Protection Cubical Panel 500 A, 650 V for 400 KVA DT | Installation of Henely Type Tailless Unit Protection Cubical Panel 500 A, 650 V for 400 KVA DT |
| 42 | Fixing of Red Oxide Paint | Fixing of Red Oxide Paint |
| 43 | Fixing of Allunimum Paint | Fixing of Allunimum Paint |
| 44 | F-Bracket | F-Bracket |
| 45 | Fixing of Allunimum Lug Barrel off size | Fixing of Allunimum Lug Barrel off size |
| 46 | Installation of CT/PT Pole Mounting Unit | Installation of CT/PT Pole Mounting Unit |
| 47 | Grouting of main metering cubicle inside the meter room alongwith termination of 11 KV cable. | Grouting of main metering cubicle inside the meter room alongwith termination of 11 KV cable. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender