Tender For Proposed Renovation, Augmentation & Redevelopment Of Snmmch College & Teaching Hospital, Dhanbad(New Opd Block Augmented From The Existing New Pg Blocks And Upgradation Of Existing Medical College & Teaching Hospital, Existing 100 Ug Seats
Tender Overview
Project Description
Tender for Proposed Renovation, Augmentation & Redevelopment Of Snmmch College & Teaching Hospital, Dhanbad(New Opd Block Augmented From The Existing New Pg Blocks And Upgradation Of Existing Medical College & Teaching Hospital, Existing 100 Ug Seats Upgradation To 250 Ug Seats To 200 Pg Seats & 16 Post Pg Seats To 50 Post Pg Seats Along With Other Allied Infrastructure & Services(Part/Phase-1, 2 And 3) Under Proposed Snmmch College & Teaching Hospital: Holistic Augmentation & Redevelopment At Dhanbad)
BOQ
| Sl. No. | Item Description |
| 1 | REBARING WORK |
| 2 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 Meter height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 Meter centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 3 | Rebaring - Chemical-Supply and application of Lokfix E77, a heavy duty, two-component epoxy anchoring chemical, provided in 3:1 ratio side-by-side cartridges with a static mixer nozzle. Upon application, it sets and cures to securely anchor various steel fixings into concrete and solid masonry substrates. It is a pure epoxy chemical anchor grout with ETA approval from DIBt for diaMeters ranging from 8 mm to 40 mm at specified embedment depths, as per manufacturer's specifications. The epoxy chemical must have a working life period certified for 100 years as per ETA from DIBt, with properties including fire resistance tested to withstand 120 minutes (DIN EN 1363-1:2012, Technical Report TR 020), and must have water tightness certificate for \\"0\\" mm under 5 bar water pressure (EN 12390-8:2019). ETA approval from DIBt for Diamond Drilling is required, alongside LEED certification and compliance with LEED V4 standards (ISO 16000, EN 16516, CDPH 01350, ASTM D2369, EPA method 24). It should compilance with European approval to EAD 330499-01-0601, anchoring in cracked and un-cracked concrete, includes fire testing to 120 minutes and C1 & C2 seismic approval. It shuould have compressive strength >110MPa (EN196-1) and flexural strength >60MPa (EN196-1). Rates shall encompass labor, tools and plants for power drilling in concrete, epoxy cartridges, plastic nozzles, and complete drilling holes with dust removal by air blowing. Cost of providing, cutting, bending of rebar steel shall be paid separately as per approved item.Rebar 8 mm Dia x 12 mm holes dia x 120 mm depth |
| 4 | Rebaring - Chemical-Supply and application of Lokfix E77, a heavy duty, two-component epoxy anchoring chemical, provided in 3:1 ratio side-by-side cartridges with a static mixer nozzle. Upon application, it sets and cures to securely anchor various steel fixings into concrete and solid masonry substrates. It is a pure epoxy chemical anchor grout with ETA approval from DIBt for diaMeters ranging from 8 mm to 40 mm at specified embedment depths, as per manufacturer's specifications. The epoxy chemical must have a working life period certified for 100 years as per ETA from DIBt, with properties including fire resistance tested to withstand 120 minutes (DIN EN 1363-1:2012, Technical Report TR 020), and must have water tightness certificate for \\"0\\" mm under 5 bar water pressure (EN 12390-8:2019). ETA approval from DIBt for Diamond Drilling is required, alongside LEED certification and compliance with LEED V4 standards (ISO 16000, EN 16516, CDPH 01350, ASTM D2369, EPA method 24). It should compilance with European approval to EAD 330499-01-0601, anchoring in cracked and un-cracked concrete, includes fire testing to 120 minutes and C1 & C2 seismic approval. It shuould have compressive strength >110MPa (EN196-1) and flexural strength >60MPa (EN196-1). Rates shall encompass labor, tools and plants for power drilling in concrete, epoxy cartridges, plastic nozzles, and complete drilling holes with dust removal by air blowing. Cost of providing, cutting, bending of rebar steel shall be paid separately as per approved item.Rebar 10 mm Dia x 14 mm holes dia x 150 mm depth |
| 5 | Rebaring - Chemical-Supply and application of Lokfix E77, a heavy duty, two-component epoxy anchoring chemical, provided in 3:1 ratio side-by-side cartridges with a static mixer nozzle. Upon application, it sets and cures to securely anchor various steel fixings into concrete and solid masonry substrates. It is a pure epoxy chemical anchor grout with ETA approval from DIBt for diaMeters ranging from 8 mm to 40 mm at specified embedment depths, as per manufacturer's specifications. The epoxy chemical must have a working life period certified for 100 years as per ETA from DIBt, with properties including fire resistance tested to withstand 120 minutes (DIN EN 1363-1:2012, Technical Report TR 020), and must have water tightness certificate for \\"0\\" mm under 5 bar water pressure (EN 12390-8:2019). ETA approval from DIBt for Diamond Drilling is required, alongside LEED certification and compliance with LEED V4 standards (ISO 16000, EN 16516, CDPH 01350, ASTM D2369, EPA method 24). It should compilance with European approval to EAD 330499-01-0601, anchoring in cracked and un-cracked concrete, includes fire testing to 120 minutes and C1 & C2 seismic approval. It shuould have compressive strength >110MPa (EN196-1) and flexural strength >60MPa (EN196-1). Rates shall encompass labor, tools and plants for power drilling in concrete, epoxy cartridges, plastic nozzles, and complete drilling holes with dust removal by air blowing. Cost of providing, cutting, bending of rebar steel shall be paid separately as per approved item.Rebar 12 mm Dia x 16 mm holes dia x 180 mm depth |
| 6 | Rebaring - Chemical-Supply and application of Lokfix E77, a heavy duty, two-component epoxy anchoring chemical, provided in 3:1 ratio side-by-side cartridges with a static mixer nozzle. Upon application, it sets and cures to securely anchor various steel fixings into concrete and solid masonry substrates. It is a pure epoxy chemical anchor grout with ETA approval from DIBt for diaMeters ranging from 8 mm to 40 mm at specified embedment depths, as per manufacturer's specifications. The epoxy chemical must have a working life period certified for 100 years as per ETA from DIBt, with properties including fire resistance tested to withstand 120 minutes (DIN EN 1363-1:2012, Technical Report TR 020), and must have water tightness certificate for \\"0\\" mm under 5 bar water pressure (EN 12390-8:2019). ETA approval from DIBt for Diamond Drilling is required, alongside LEED certification and compliance with LEED V4 standards (ISO 16000, EN 16516, CDPH 01350, ASTM D2369, EPA method 24). It should compilance with European approval to EAD 330499-01-0601, anchoring in cracked and un-cracked concrete, includes fire testing to 120 minutes and C1 & C2 seismic approval. It shuould have compressive strength >110MPa (EN196-1) and flexural strength >60MPa (EN196-1). Rates shall encompass labor, tools and plants for power drilling in concrete, epoxy cartridges, plastic nozzles, and complete drilling holes with dust removal by air blowing. Cost of providing, cutting, bending of rebar steel shall be paid separately as per approved item.Rebar 16 mm Dia x 20 mm holes dia x 240 mm depth |
| 7 | Rebaring - Chemical-Supply and application of Lokfix E77, a heavy duty, two-component epoxy anchoring chemical, provided in 3:1 ratio side-by-side cartridges with a static mixer nozzle. Upon application, it sets and cures to securely anchor various steel fixings into concrete and solid masonry substrates. It is a pure epoxy chemical anchor grout with ETA approval from DIBt for diaMeters ranging from 8 mm to 40 mm at specified embedment depths, as per manufacturer's specifications. The epoxy chemical must have a working life period certified for 100 years as per ETA from DIBt, with properties including fire resistance tested to withstand 120 minutes (DIN EN 1363-1:2012, Technical Report TR 020), and must have water tightness certificate for \\"0\\" mm under 5 bar water pressure (EN 12390-8:2019). ETA approval from DIBt for Diamond Drilling is required, alongside LEED certification and compliance with LEED V4 standards (ISO 16000, EN 16516, CDPH 01350, ASTM D2369, EPA method 24). It should compilance with European approval to EAD 330499-01-0601, anchoring in cracked and un-cracked concrete, includes fire testing to 120 minutes and C1 & C2 seismic approval. It shuould have compressive strength >110MPa (EN196-1) and flexural strength >60MPa (EN196-1). Rates shall encompass labor, tools and plants for power drilling in concrete, epoxy cartridges, plastic nozzles, and complete drilling holes with dust removal by air blowing. Cost of providing, cutting, bending of rebar steel shall be paid separately as per approved item.Rebar 20 mm Dia x 24 mm holes dia x 300 mm depth |
| 8 | Rebaring - Chemical-Supply and application of Lokfix E77, a heavy duty, two-component epoxy anchoring chemical, provided in 3:1 ratio side-by-side cartridges with a static mixer nozzle. Upon application, it sets and cures to securely anchor various steel fixings into concrete and solid masonry substrates. It is a pure epoxy chemical anchor grout with ETA approval from DIBt for diaMeters ranging from 8 mm to 40 mm at specified embedment depths, as per manufacturer's specifications. The epoxy chemical must have a working life period certified for 100 years as per ETA from DIBt, with properties including fire resistance tested to withstand 120 minutes (DIN EN 1363-1:2012, Technical Report TR 020), and must have water tightness certificate for \\"0\\" mm under 5 bar water pressure (EN 12390-8:2019). ETA approval from DIBt for Diamond Drilling is required, alongside LEED certification and compliance with LEED V4 standards (ISO 16000, EN 16516, CDPH 01350, ASTM D2369, EPA method 24). It should compilance with European approval to EAD 330499-01-0601, anchoring in cracked and un-cracked concrete, includes fire testing to 120 minutes and C1 & C2 seismic approval. It shuould have compressive strength >110MPa (EN196-1) and flexural strength >60MPa (EN196-1). Rates shall encompass labor, tools and plants for power drilling in concrete, epoxy cartridges, plastic nozzles, and complete drilling holes with dust removal by air blowing. Cost of providing, cutting, bending of rebar steel shall be paid separately as per approved item.Rebar 25 mm Dia x 29 mm holes dia x 350 mm depth |
| 9 | Providing and applying bond coat on the prepared surface with two component epoxy based bonding coat , having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs and 30 ̊C.\\" |
| 10 | Supply and fixing of rebars of designated dia for column/beam/Shear walls/Foundations at designed embedement length wherever required , including power drilling, cleaning of holes, then rebars should be inserted in holes that should be filled, a heavy duty pure epoxy based rebarring chemical with ETA approval, DIBt, approved for diaMeter range from 8 mm to 40 mm reinforcement bar as per manufacturer's specification as per the direction of Engg In-charge. Drilling of hole should be done upto provided embedment depth as per the design from manufacturer approved by EnC, followed by cleaning with blow pump, wire brush and blow pump for 4 times, complete as per the manufacturer's methodology. The chemical shall be approved for diamond-drilled and water-filled drill holes as well as seismic applications in performance categories C1, C2 for rebar connections. Product shall have test certificate of service life & shall have ETA complying to EAD 332402-00-0601-v01. Cost of providing, cutting, bending of rebar steel shall be paid separately as per approved item. 8mm * 100mm Depth |
| 11 | Supply and fixing of rebars of designated dia for column/beam/Shear walls/Foundations at designed embedement length wherever required , including power drilling, cleaning of holes, then rebars should be inserted in holes that should be filled, a heavy duty pure epoxy based rebarring chemical with ETA approval, DIBt, approved for diaMeter range from 8 mm to 40 mm reinforcement bar as per manufacturer's specification as per the direction of Engg In-charge. Drilling of hole should be done upto provided embedment depth as per the design from manufacturer approved by EnC, followed by cleaning with blow pump, wire brush and blow pump for 4 times, complete as per the manufacturer's methodology. The chemical shall be approved for diamond-drilled and water-filled drill holes as well as seismic applications in performance categories C1, C2 for rebar connections. Product shall have test certificate of service life & shall have ETA complying to EAD 332402-00-0601-v01. Cost of providing, cutting, bending of rebar steel shall be paid separately as per approved item.10mm * 150mm Depth |
| 12 | Supply and fixing of rebars of designated dia for column/beam/Shear walls/Foundations at designed embedement length wherever required , including power drilling, cleaning of holes, then rebars should be inserted in holes that should be filled, a heavy duty pure epoxy based rebarring chemical with ETA approval, DIBt, approved for diaMeter range from 8 mm to 40 mm reinforcement bar as per manufacturer's specification as per the direction of Engg In-charge. Drilling of hole should be done upto provided embedment depth as per the design from manufacturer approved by EnC, followed by cleaning with blow pump, wire brush and blow pump for 4 times, complete as per the manufacturer's methodology. The chemical shall be approved for diamond-drilled and water-filled drill holes as well as seismic applications in performance categories C1, C2 for rebar connections. Product shall have test certificate of service life & shall have ETA complying to EAD 332402-00-0601-v01. Cost of providing, cutting, bending of rebar steel shall be paid separately as per approved item.12mm * 150mm Depth |
| 13 | Supply and fixing of rebars of designated dia for column/beam/Shear walls/Foundations at designed embedement length wherever required , including power drilling, cleaning of holes, then rebars should be inserted in holes that should be filled, a heavy duty pure epoxy based rebarring chemical with ETA approval, DIBt, approved for diaMeter range from 8 mm to 40 mm reinforcement bar as per manufacturer's specification as per the direction of Engg In-charge. Drilling of hole should be done upto provided embedment depth as per the design from manufacturer approved by EnC, followed by cleaning with blow pump, wire brush and blow pump for 4 times, complete as per the manufacturer's methodology. The chemical shall be approved for diamond-drilled and water-filled drill holes as well as seismic applications in performance categories C1, C2 for rebar connections. Product shall have test certificate of service life & shall have ETA complying to EAD 332402-00-0601-v01. Cost of providing, cutting, bending of rebar steel shall be paid separately as per approved item.16mm * 200mm Depth |
| 14 | EARTH WORK |
| 15 | Earth work in excavation in foundation trench in ordinary soil (vide classification of soil item - B ) and disposal of excavated earth as obtained to a distance up to 50 M including all lift , leveling ramming the foundation trenches removing roots of tree shrubs all complete as per approved design building specification and direction of E/I |
| 16 | Extra for earth work in hard soil as per specification & direction of engineer in charge (Vide classification of soil item B) |
| 17 | Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil |
| 18 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth, lead up to 50 m and lift up to 1.5m, as directed by Engineer-in-Charge. Ordinary rock |
| 19 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Ordinary rock |
| 20 | Earth filling in foundation trenches and plinth in layer not exceeding 150 mm thick wall watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trencheed with a lead of 50mm and lift of 1.5 m all complete as per building specification and direction of E/I ( mode of measurement compacted volume ) |
| 21 | Providing coarse clean local sand in filling in foundation trench or in pinth including ramming and watering in layer not exceeding 150mm thick with all lead and 1.5 m lift including cost of all material , labous , royality and taxes all complete as per building specification and direction of engineer in charge ( mode of measurement compacted volume) |
| 22 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l |
| 23 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 24 | Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling12 mm diaMeter holes and plugging with cement mortar 1 :2(1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration |
| 25 | Disposal of earth by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 26 | --------------------------------------------------------------------------------------------------------------------------------------------- |
| 27 | --------------------------------------------------------------------------------------------------------------------------------------------- |
| 28 | --------------------------------------------------------------------------------------------------------------------------------------------- |
| 29 | --------------------------------------------------------------------------------------------------------------------------------------------- |
| 30 | --------------------------------------------------------------------------------------------------------------------------------------------- |
| 31 | --------------------------------------------------------------------------------------------------------------------------------------------- |
| 32 | --------------------------------------------------------------------------------------------------------------------------------------------- |
| 33 | --------------------------------------------------------------------------------------------------------------------------------------------- |
| 34 | --------------------------------------------------------------------------------------------------------------------------------------------- |
| 35 | --------------------------------------------------------------------------------------------------------------------------------------------- |
| 36 | CONCRETE WORK |
| 37 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded stone aggregate 20 mm nominal size if required for plinth area |
| 38 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 39 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 40 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 41 | --------------------------------------------------------------------------------------------------------------------------------------------- |
| 42 | Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 43 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 44 | Providing 250mm . Wide brick drain in cement morter (1:6) with av.150mm.clear depth and 250mm. Apron including cost of earthwork involved with 75mm. Cement concrete (1:4:3) over on e brick designation 75A flat soling in proper grade and slope at the base the drian duly plastered in CM (1:3) with punning over exposed surface all complete as per building specification a nd direction of E/I. |
| 45 | RCC WORK |
| 46 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 47 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 48 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 1.10% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work upto plinth Level Concrate of M25 grade with minimum cement content of 330 kg/cum |
| 49 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 1.10% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All work above plinth Level Concrate of M25 grade with minimum cement content of 330 kg/cum |
| 50 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 51 | Extra for RCC/BMC/RMC/ work above floor v level for Each four floor levels |
| 52 | Concrete of M30 grade with minimum cement content of 350 Kg /Cum |
| 53 | Providing Tor steel reinforcement of 8mm. dia.TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL)) |
| 54 | Providing Tor steel reinforcement of 10mm,28/32mm dia. TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL)) |
| 55 | Providing Tor steel reinforcement of 12/16mm. & 20/25mm. dia. TMT rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT Fe 500 (only vailid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizal steel(RINL)) |
| 56 | Centering and shutteing including struting, propping etc and removal of form for Foundations, footings, bases for columns, etc for mass concrete |
| 57 | Centering and shutteing including struting, propping etc and removal of form for Walls ( any thickness) including attached pilasters, butteresses, plinth and string course etc |
| 58 | Centering and shutteing including struting, propping etc and removal of form for Suspended floors,roofs,lancing,balcones and access platform |
| 59 | Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ) |
| 60 | Centering and shutteing including struting, propping etc and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 61 | Centering and shutteing including struting, propping etc and removal of form for Columns, Pillars, Piers, abutments, Posts and struts |
| 62 | Centering and shutteing including struting, propping etc and removal of form for Stair , ( excluding landings), except spiral staircase |
| 63 | Centering and shutteing including struting, propping etc and removal of form for Extra for shuttering in circular work ( 20% of respective centering and shuttering items) |
| 64 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 Meter or part thereof (Plan area to be measured). uspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
| 65 | Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 50mm thick |
| 66 | BRICK WORK |
| 67 | Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 68 | Providing designation 75 B brickwork in C M ('1 :6 ) in foundation and Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing. taxes and royalty all complete as per building specification and direction of E/l. |
| 69 | Providing designation 75A brickwork in CM (1:3) in superstructure with approved quality of clean coarse sand of FM 2 to 2,5 including providing 10mm thick mortar joints , cost of screening, materials, scaffolding, raking out joints to 15mm depth curing, taxes and royalty all complete as building specification and direction of E/I |
| 70 | providing designation 75 B brickwork in C M ('1 :6 ) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing. taxes and royalty all complete as per building specification and direction of E/l. |
| 71 | Extra for brick work for Each consecutive floor above first floor including watering and scaffolding, all complete as per direction of Ell. |
| 72 | Providing designation 100A brick work with flyash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints costs of screening materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I. |
| 73 | Providing Designation 100A B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9\\"x4.5\\"x3\\") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 74 | Providing designation 112 mm thick reinforced designation 100 A brick work vuith fly ash lirne brick (FLAG)confirming to lS 12894-1990 (9\\"x4'5\\"x3\\" ) in C.M. ( 1 . 4 ) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials,n caffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specificationand direction of E/|. |
| 75 | Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for Each four floors or part thereof by mechanical means |
| 76 | Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means . |
| 77 | Extra for providing and placing 2 no 6mm dia MS bar every 3rd coarse of half brick masonary |
| 78 | Half brick masonry with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (cement mortar 1: 4 coarse sand) |
| 79 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement: 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 80 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 81 | WOOD WORK |
| 82 | Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I. |
| 83 | Supplying, fitting and fixing good quality, well dressed and well seasoned teak wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I. |
| 84 | Supplying,fitting and fixing 38mm thick good quility well dressed and well seasoned sal wood fully paneled shutter in doors and window with 25mm thick panels with one side plain chamfered with oxidiesd iron fitting such as hinges, sliding door, bolts,tower bolts, handles or rings , hooks and eyes, cleats, sand blocks as per schedule, taxes and royalty all complete as per building specification and direction of E/I |
| 85 | Supplying fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts,handle, cleats and sand blocks and laxes all conrplete as pe building specification and direction of E/l. |
| 86 | Supplying fitting and fixing 35mm thick solid core type decorative double leaf flush door sltutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts,handle, cleats and sand blocks and laxes all conrplete as pe building specification and direction of E/l. |
| 87 | Supplying fitting and fixing 35mm thick solid core type decorative double leaf flush door sltutter with both side decorative veneered with black board core bended with high quality phenol formal clehydes synihetic resin of standard make with Aluminium fittings :such as hinges, tower bolts, handle, cleats and sand blocks and laxes all conrplete as pe building specification and direction of E/l. |
| 88 | Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make without oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 89 | Supplying, fitting and fixing 35mm thick solid core type non-decorative double leaf flush shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make without oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 90 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality1.0 mm thick |
| 91 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied withspecial grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in requiredproportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) |
| 92 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 93 | Extra for providing vision panel not exceeding 0.1 Sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square |
| 94 | Extra if louvers (not exceeding 0.2 Sqm) are provided in flush door shutters (overall area of door shutters to be measured). Decorative type door |
| 95 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 96 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. |
| 97 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per anufacturer’s specification and direction of Engineerin- chargeExtruded section profile size 48x40 mm |
| 98 | 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge |
| 99 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 Kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness |
| 100 | Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet (Zinc coating not less than 120 gm/Sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/Sqm. The frame will have a provision of G.I. anchor fastners 14 nos (5 Each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of size 100x89x3 mm for fixing of fire rated glazed shutter. The frame shall be finished with an approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge. (Cost of SS ball bearing hinges is excluded). |
| 101 | Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 Kg/ m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (paneling to be paid for separately). |
| 102 | Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/Sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-Charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (El20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & El. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredited labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 Sqm. |
| 103 | Providing and Fixing roller blind with head channel, traversing cord, and warranty etc as per manufacturer's specifications. Fabric sample to be as instructed and approved by Architect.Providing and fixing Roller Blinds as per the approved sample comprising of sunscreen Fabric comprising of 30% polyester and 70% PVC with openess factor of 5% having a width of 250-300 cm.Fabric weight 428±5% Grams per Sqm, Thickness 0.73 mm ±5%, GREENGUARD NFPA701 ceritified fabric. Healty/safety standard - Oekotex Standard 100 and it provides UV protection upto 95%.The fabric has mechanical breaking resistance – warp≥ 1310 N/5cm, Weft: > 1420 N/5cm. Color fastnes to Light Grade 8.The Roller blind system consists of 38mm OD extruded out of Aluminium alloy 6063 T6 with silver anodized to provide an everlasting finish and luster, the rotary unit shall be 36mm in OD incorporating a clutch mechanism composed of low – flexing braided polyster cord with nylon core, Control Ball chain shall be composed of braided nylon cord (2mm dia) with high engineering grade plastic beads of 4.5mm diaMeter mounted co-axially on the cord with a pitch of 6.2mm (C-T-C) Bottom rail should be powder coated Aluminium flat bottom rail of 290 gm to finish it from the ends it should have rail end caps. The clutch will be at the tube. The return end cap bracket shall incorporate snap spring design to facilitate easy installation and removal for maintenance activities. The bracket shall be finished with a flush mounting cover on Each side providing an aesthetic finish. It should handle up to 5 Kgs of material. The clutch should mount flush to the face of the bracket which minimize the light gap between the shade and the window frame. All complete as per approval of designer & instruction of Project Manager. |
| 104 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness.The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat . Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame |
| 105 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame andsuitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixingto frames. |
| 106 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. |
| 107 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 108 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured). |
| 109 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 Kg to 80 Kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 110 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete:300x16 mm |
| 111 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete:250x16 mm |
| 112 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade wiIh necessary screws etc. complete :125 mm |
| 113 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade wiIh necessary screws etc. complete :100 mm |
| 114 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
| 115 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 116 | Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. |
| 117 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete:250x10 mm |
| 118 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete:150x10 mm |
| 119 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete 255 X 19 mm |
| 120 | Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in-charge Polyester Powder coated minimum thickness 50 micron aluminium |
| 121 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/ mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately)25 mm thick |
| 122 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/clerestory windows & desertory other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 Kg/ Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus sideshall be acceptable but no extra payment on this account shall be made.Frame size 45 x 70 mm |
| 123 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/Sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). |
| 124 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). |
| 125 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 126 | Providing and fixing factory made uPVC Glazed/wire mesh windows/ doors comprising of lead free upvc multi chambered frame sash and mullion/couper (where ever required) exruted profile having minimum wall thickness of 1.70 mm for series R1 and R2 profile and 2.10 mm for series R3 and R4 profiles conforming to EN : 12608 in any shape colour and design duly reinforced with galvanized mild steel section made of required ) of appropriate dimension, EPDM gasket , hardware ,SS 304 grade fasteners of minimum 8 mm dia with countersunk head comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : part 1 to 14 plastic packers plastic mullion ( if required) shall be mitred cut and fusion welded/ mechanically jointed duly sealed at all corners including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backrer rod of approved size and quality all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-charge. section of steel reinforcement and cross sections of upvc profile to be as per design approved By Engineer-in-charge.Wire/wire/glazing of plain/ toughened/ laminated/ double glass unit with/without high performance coating as per design requirement and conforming to IS : 3548 & IS: 16231 shall be paid separately.Noted :- structural design proof checked from a government engineering institute to be provided by the manufacturer for (i) Site with basic wind speed > 45 m/sec as per IS 875 -part 3 (ii) sites with structure height more then 20m for all wind speeds |
| 127 | Using R3 series with frame (55 mm & above ) X (40 mm & above ) & sash ( 30 mm & above) x (55 mm & above ) With zinc alloy (zamak) powder coated handle on every panel along with multi point locking system ( height upto 1.8m). |
| 128 | Casemnet door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above ) x (85 mm & above ). Height upto 2.5 Meter) |
| 129 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 130 | Providing and fixing S.S. sliding door bolts (aldrop) with nuts and screws etc. complete:250x16mm |
| 131 | Providing and fixing S.S. sliding door bolts (aldrop) with nuts and screws etc. complete:300 x 16mm |
| 132 | Providing and fixing SS sliding tower bolt with required fastners (Screws) complete:250x10 mm |
| 133 | Providing and fixing SS sliding tower bolt with required fastners (Screws) complete:600 mm |
| 134 | Providing and fixing SS handles \\"D\\" type with required fastners (Screws) complete:250x19 mm (Pipe dia) |
| 135 | Providing and fixing SS handles \\"D\\" type with required fastners (Screws) complete:200x19 mm (Pipe dia) |
| 136 | Providing and fixing SS hanging floor door stopper with necessary screws etc.complete:150 mm Rubber Stopper |
| 137 | Providing and fixing SS door latch with necessary screws etc. complete.250x12 mm |
| 138 | Providing and fixing SS sliding baby latch with required fastners (Screws) complete:100 x 10 mm |
| 139 | Providing and fixing SS sliding baby latch with required fastners (Screws) complete:Providing & Fixing Wall mounted door Buffer |
| 140 | floor spring with std. spindle and cover plate. The floor spring with backcheck and adjustable closing speed from 175°. Non-hold open. As per EN 1154 and CE marked. Finish: Satin stainless steel. |
| 141 | Standred top pivot |
| 142 | Standred top patch fitting |
| 143 | Standred bottom patch fitting |
| 144 | Standard Lock with Strike plate & EPC |
| 145 | pull Handle back to back with 350mm CTC, adjustable fixing for glass, wood and metal doors in satin stainless steel. The pull handles should have supporting washer with raised bevelling on the outer surface. Length =450mm, 25mm dia, -SS304 |
| 146 | floor stop half dome with 45mm dia with fixing accessories, in satin Chrome |
| 147 | P/F lead lined door, the frame for the door is second class teak wood (ivory cost ) properly seasoned wood of section 100*60mm with a coat of viper make primer and paint. 44mm thick doors shutter are made out of 34mm thick BWP grade board door shutter sandwiching 2mm thick lead sheet of radiation control, 6 mm thick commercial ply and 1mm thick laminate in shuede finish on both the faces of shutter lead lining to be done for frame and shutter both with 2mm thick lead sheet of radiation control. The frames are fitted in masonary opening with the help of anchor fastners of size 10*100/10*120mm. Hardware for the doors are inclusive and includes - stainless steel SS ball bearing hinges 100*75*3 mm of beaker of equivalent make, Dead lock with both side key opration of Becker or equivalent make back to back D handels of size 19*300 mm stainless steel grade , Face mounted Tower bolt 300 mm long of Becker or equivalent make, face mounted door closer of Becker or equivalent make, all work is being carried out under the direction of Engineer in charge. |
| 148 | P/F 8mm thick lead lined glass for lead lined doors with complete beading and screws as per the direction of Engineer in charge. |
| 149 | STEEL WORK |
| 150 | Supplying,frtting and fixing M.S. grill made of 20x6cmm M.S. flat as per approved design and drawing, properly fabrlcated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/1 |
| 151 | Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm square bars fitted on 25x25x6mm M.S Angle frame including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l. |
| 152 | --------------------------------------------------------------------------------------------------------------------------------------------- |
| 153 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer.Using M.S. angle 40x40x6 mm for diagonal braces |
| 154 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer- in-charge Profile C Fixing with adjustable lugs with split end tail to Each jamb |
| 155 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge profile BFixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 156 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 157 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 158 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 159 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 160 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting thegrill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 161 | FLOORING WORK |
| 162 | providing and laying, vitrified step/dado tiles in with water absorption less than 0.08% and conforming to lS 15622/ of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 Kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 1200x300 mm X15MM |
| 163 | providing and laying, Doublecharge vitrified floor tiles in different sizes (thickness to be specified by lhe manufacturer) with water absorption less than 0.08% and conforming to lS 15622/ISO 13009 of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 Kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 600x600 mm |
| 164 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills. facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, induding rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levelsGranite of any colour and shade Area of slab upto 0.50 Sqm |
| 165 | Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab over 0.50 Sqm |
| 166 | Providing edge moulding to 18 mm thick marble/granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 167 | Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. |
| 168 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishingof cut edges etc. complete. |
| 169 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 170 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade |
| 171 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all coloursand shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 Kg/Sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 172 | Kota stone slab flooring over 25 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand) :600x600 |
| 173 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, includingrubbing and polishing complete. |
| 174 | Providing and laying 1st quality Ceramic glazed wall tiles thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 175 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
| 176 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-ChargePolished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 177 | Providing 50mm thick cement concrete flooring (1:2:4 with 20mm to 6mm size grade stone chips finish with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes & royality with all complete as building specification and direction of E/I |
| 178 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile |
| 179 | Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarseMedium shade pigment using 50% white cement and 50% ordinary cement |
| 180 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Raj Nagar plain |
| 181 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Medium shade pigment using 50% white cement, 50% ordinary cement |
| 182 | Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 Kg/Sqm including pointing in white cement complete. 8.mm thick Granite of any colour and shade |
| 183 | Providing and laying of 2 - 3 mm average thick layer of cementations smoothening compound of UZIN NC 149 sh or equivalent as recommended by the Vinyl sheet flooring manufacturer over and including a priming compound of UZIN PE 360 sh or equivalent as recommended by the Vinyl sheet flooring manufacturer and installation team on concrete surface to provide a smooth & homogenous surface for laying of vinyl sheet flooring complete to the entire satisfaction of Engineer-in-charge. |
| 184 | Providing & Fixing flexible Conductive PVC sheet flooring having a total thickness of 2mm and weight of 3Kg/m².Colors and pattern detail shall be dispersed throughout the thickness of the wear layer. It shall conform to Group P of Wear Resistance as per EN 649, Flammability of class Bfl-s1 as per EN 13501-1, Slip resistance as per DIN 51130 group of R9 , having REach Registration No, 1907/2006 contains no substance mentioned in SVHC list. Impact sound reduction of 3 dB as per ISO 140-8, Residual indentation of 0.05 mm as per EN 433, Color fastness rating ≥6 as per ISO 105-B02, Vertical resistance(R1) less than 1 x 10⁶- 1x 10⁸Ω as per EN 1081, and surface resistance less than 1 x 10⁶- 1x 10⁸ Electrical insulation to ground greater than 50 kΩ as per VDE 0100, Static electrical charge of ≤2.0kV as per EN 1815, Thermal resistance of 0.04m²K/W as per EN 12667, Thermal conductivity of 0.25 W/mK. Installation:It is important to ensure the sub floor on which the sheet is being laid issmooth, flat & hard & free from moisture, grease, etc. In case of uneven sub floor theThe moisture level present in the subfloor should be less than 8% before installation of the floor. The sheet should be laid using adhesive recommended by company.Each row of tiles/strip of floor covering must be linked crosswise with a continuous copper strip. Individual rows/strips must be at least 3 m² in size and linked to the rest of the area with a copper tape. In rooms of up to 40 m², connection points for equipotential bonding should be provided in at least one point in the room. |
| 185 | Supply and installation of PVC sheet flooring 2 Meter wide and overall thickness of 2mm . The product should be homogeneous and single layered. The wear surface shall consist of impregnated polyurethane homogeneous mixture of PVCwith DIAMOND 10 technology, Plasticizers without DOP, Urethane, color pigments and filler calendered to form a sheet. Product shall conform to group \\"T\\" wear resistance as per EN 649, Flammability resistance of class Bfl-s1 as per EN13501-1, Dynamic coefficient of friction of class DS as per EN 13893, Impact sound reduction of 3dB as per ISO 10140, Slip Resistance of class R9 as per DIN 51130, Color fastness rating of ≥6 as per ISO 105-B02, total weight being 3.3 Kg/m2 as per EN430. The product shall be suitable for applications in class 23/34/43 areas as per EN685. Product shall exhibit antistatic behaviour, resistance to bacteria,resistance to chemical, resistance to staining,suitability to castor chair.Installation- It is important to ensure the subfloor on which the sheet is being laid is smooth, flat, hard and free from moisture, grease etc. In case of uneven subfloor the same should be levelled using self leveling compound which will charged extra. The moisture present in the subfloor should be less than 8% before installation of the floor. dhesive. The installation shall be undertaken as per manufacturers installation instructions. |
| 186 | P&F flexible PVC sheet wall cladding in 1.00 mm thickness in the size of 1.5 x20Meter with PUR treatment. The wear surface shall consist of impregnated polyurethane homogeneous mixture of PVC, Plasticizers, Urethane, color pigments and filler calendared to form a sheet. Colors shall be dispersed throughout the thickness of the wear layer. It should conform to Group M of Wear Resistance as per EN 660-2, Fire resistance of group 2 as per AS/NZS3837, Residual indentation of ≤0.10mm as per EN433, curling after exposure to moisture ≤8mm as per EN434, Seam strength of mean≥240N/50mm as per EN684. |
| 187 | Providing and fixing of rubber tile size of 600x600 for gzm area with cutting and colour as per ASI approval in complete as per engineer-in-charge |
| 188 | Providing and Fixing of 6.5 mm Gym/Sports Flooring width of material 1.5 mm length 20 Meter Wear layer of material should be 1.2 mm and anti bacterial. weight of material 4800 g/per Sq Meter Material should be passed from below test as per standardShock Absorption >25% 38%sliding coefficient 0.4 - 0.7 0.5-0.55Energy Return >0.31 0.50Ball bounce >90% 94%Sound Isolation dB 26 All complete as per direction of engineer incharge. |
| 189 | Providing Epoxy flooring self leveling type on strong base in desired colour/design as approved by Engineer-in-Charge. Resin for epoxy is to be of floor grade type i/c appropriate hardner and filler material. with 5 year defect liability period 3mm thick |
| 190 | Providing & Fixing of Linear Flocked textile floor covering of Nylon 6.6 face fiber or equivalent of approved make with 100% Nylon and completely water proof resilient backing. The flooring should be Anti static with thickness of 4.3 mm and approximate weight of 1.8 k.g./Sqm of roll form. The carpet should be completely stain resistant and of a density approx. 80 million fibers/sq.Meter (70 million fiber/sq.yd) in the width of 2 Meter .The floor covering should have Fire Test EN-13501, Appearance Retention Hexapod ISO 140-8, Friction Slip Resistance Test EN 14041 Class DS, with resilient waterproof backing, anti allergic which is certified by British allergy foundation, with ten year replacement guarantee. The carpet should have permanent static control & should be fixed with powder coated aluminum angles as per detail. The work should be carried out by the authorized installer of the Company in India. |
| 191 | Providing and fixing Fabric rockwool based Acoustical Wall Paneling 600x600 25mm Fixing with the help of specially designed Metal Impellers of sizes 77mmx102mm which all are properly Sound Strut screw fixed horizontal/vertical to wall at every 600mm c/c.While installation the top end of The panels should place of line then carefully should swing the bottom edge to meet impellers heads.The NRC : should be Up to 0.9,should meet the safety requirements of EN 14190. |
| 192 | Providing and fixing dB Wood Perforated panels of width 190mm, thickness of 15mm and length of 1180mm , made of a medium density fibre board substrate with laminated/Melamine facing as per the approved shade / species and finish and a melamine balancing layer over the reverse side. .The board shall have a special perforated pattern of 6 mm diaMeter of hole thru out the area with a toung and groove to fix on the wall without screw. Installed with rockwoll of 50mm thick a periMeter of 0.5mm thick have a unequal flange of 26 mm and 18 mm to be fixed on floor and soffit with the help of water level marking, than a GI section of (Hat channel) shall be placed at c/c 600 to make a grid. than specially extruded aluminum sections of 18 mm x25 mm shall be fixed to hat channel perpendicular using Metal screws spacing at 600mm c/c. Place the dB Wood clip to install the first set of wooden panels by inserting the clips for border and insert the panel into projecting flange of clip. Continue installing rows of panels by inserting the tongue into the groove of earlier inserted panel and progressively installing clips for inside into the next keel till the actual height is achieved. Use clips for the border to finish off the installation. Edges should be finished using wooden moulding of matching colour. A slab of rockwool 48 Kg density and 50mm thick shall be placed under the groowood olmac panel.The system shall give NRC of 0.77 with as per ASTM C 423, The color and design shall be approved by architech & Engineer In-charge. |
| 193 | Providing and fixing machine cut, mirror / eggshell polished , Granite stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required,stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement :3 coarse sand) laid and jointed with white cement slurry @ 3.3 Kg/Sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.18 mm thick Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. Please Enable Macros to View BoQ information |
| 194 | Providing and fixing machine cut, mirror / eggshell polished , Granite stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required,stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement :3 coarse sand) laid and jointed with white cement slurry @ 3.3 Kg/Sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.18 mm thick Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 29 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender