Tender For Rfp For Fire-Escape Staircase At Suraksha
Tender Value
1 Crore
Estimated cost
Bid Submission
14 Dec 2026
22 days left
EMD
2 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Rfp For Fire-Escape Staircase At Suraksha
BOQ
| Sl. No. | Item Description |
| 1 | Excavation for foundation in Hard rock by chiselling, wedging, linedrilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5m). By Mechanical Means. |
| 2 | Filling in plinth and floors with approved excavated materials in 15cm-20cm layers including watering and compaction complete. |
| 3 | Filling plinth and floor with contractor’s murum in 15cm-20cm layers including watering and compaction complete. |
| 4 | Providing dry rubble stone pitching 23 cm (about 9 ) thick including all material, quarry spalls, labour etc. complete. |
| 5 | Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only.Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) - (FOUNDATION PCC) |
| 6 | Providing and laying Cast in situ / Ready Mix cement concrete M-30 of trap / granite / quartzite / gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying / pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 7 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. |
| 8 | Providing and fabricating structural steel work in rolled sections, fixed with connecting plates or angle cleats in main and cross beams, hip and jack rafters, purlins connecting to truss members and the like, as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. |
| 9 | Providing and laying cement brick bat coba with one part of cement mortar (1:4) and two parts of broken brick bats to be mixed and laid to required |
| 10 | Providing and laying waterproofing treatment of 112mm average thickness consisting of 12mm thick layer in C.M1:3 with waterproofing compound @ 1kg / bag of cement as base constructing laying brick bat coba in C.M.1:5 with waterproofing compound @ 1kg bag including all lead all lead ,lift & laid to proper slope to drain off water |
| 11 | Providing a laying cement concrete flooring 40mm thick with 1:2:4 cement concrete including waterproofing compound @ 1kg./laid to proper slope and level |
| 12 | Providing cement vata C.C.1:2:4 to the junction of terrace parapet & the elsewhere, with finishing the same with neat cement and curing the same for 7 days etc. complete. |
| 13 | Strengthening the R.R.C. surface by providing plaster in cm 1:3including neeru finish with portion of the plaster watering curing etc.competed with two coats of colour wash (plaster to be minimum25mm thick) for cloumns, floor RCC projections, slabs, etc. as persite |
| 14 | Strengthening the load bearing wall by removing existing plastercracks and loose open joints of the masonry filling hollows whereverfound necessary with brick , laid in rich cement mortar replacingbroken brick and broken cornices and re plastering with 1:3 cementmortar 25mm-30mm thick in two coats including scaffolding andapplying two coats colour wash etc .(old and new ) for staircase facewall on ground to first floor and upto sixth floor. |
| 15 | Providing & applying two coats of synthetic enamel paint of approved colour and shade to old and new structural steel on all surface in Staircase including scaffolding if necessary cleaning the surface etc complete (excluding primer coat) size up to & inclusive of 175mm. & above 175mm |
| 16 | Providing & applying colour wash of approved colour & shade to thewall surface, all thefloors with repaired surfaces in two coats to newsurface including scaffolding. |
| 17 | Providing & fixing jute kantan screen with the steel scaffolding of external side of the building to cover the required area of staircase face wall including removing the same after the work is over etc. |
| 18 | Pulling down brick/ stone masonry in cement mortar with plaster of openings at floor intervals for fire exit doors from ground floor to sixth floor. |
| 19 | Providing Doorma Company or specified by the consultant fire exit doors with glass wool Filling fire resistant doors size 4’-00”x 7’-00” |
| 20 | Providing Second Class Burnt Brick masonry with conventional/I.S. type bricksfor extrnal walls & opening plinth in cement mortar 1:6 in foundations and plinth of inner walls/in plinth of external walls including bailing out water manually, striking joints on unexposed faces, racking out joints on exposed faces and watering etc.complete. |
| 21 | Providing 3 mm M.S. chequared plate for floor landing, midlanding portions all treads |
| 22 | Providing, fabricating & fixing in position S.S. 304 grade pipe railing for staircase consisting of 18 gauge 38-50 mm dia. S.S.pipe as top rail, 18 gauge 40 mm dia S.S. pipe as verticals at 1000MM C/C, 2 No.s of 18 gauge 25 mm dia as secondary rails, including fixing the verticals to the staircase pardi by means of base plate with socket & anchor fasteners,grinding the welded portion smooth,buffing, protecting the railing members by means of wrappers during construction etc. complete as directed by the Engineer in charge. |
| 23 | Providing and fixing the Mechanical Anchor Fasteners as specified below of Hilti Make or equivalent confirming to IS 1367 (Part 3) at required locations and level including drilling the hole, cleaning and anchoring the bolt as per manufacturersspecifications etc. complete as directed by Engineer In Charge. M30 |
| 24 | Providing and laying in position ready mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying and the cost of centering, shuttering, finishing and excluding reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.The Mix design as per particular specfications shall be got approved by Engineer-in-Charge before execution of the item.The rate shall include cost of all specified materials and operations at all levels and heights, including the cost of centering, shuttering and and excluding reinforcement which shall be paid under relevant item.(Note :- Cement content considered in this item is @ 300 kg/cum as per IS 456 table showing minimum cement content. No extra will be paid nor any amount will recovered on account of variation of cement in mix design as per specifications for controlled concrete). Lintels, beams, plinth beams, girders, floor beam, coping , Weather shade, Chajjas, corbels, cantilever beam, etc., including edges. |
| 25 | Providing and fixing in position steel bars reinforcement of various diameters for R.C.C. pile, pile caps, footings,raft,retaining wall,shear wall, lift wall, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, coping, fins, arches, etc. as per detailed designs, drawings and bar bending schedules,including straightening, cutting, bending, hooking the bars, binding with wires or tack welding, supporting as required etc. all complete at all levels. Thermo-Mechanically Treated steel bars. (Fe 500 D) |
| 26 | providing, erecting & dismantling Debris protection platform afteruse of temporary platform made up of plywood/G.I. Sheets/Bambooetc. supported with steel/Bamboo(as required by consultant) props tosafegurad or protect entry /exit movements areas, sheds etc. fromfalling debris while work in progress to allow safe passgae of vehiclesand pedestrians with all necessary arrangements complete or asinstructed by consultanting engineer or Architect. |
| 27 | providing and fixing of foundation bolts and nuts in RCC M-12 to M20 columns/pedestal/beam at any level including maintaining the accuracy towards lin, level & position including making and using the template etc. complete as directed by engineer in charge. (contractor will take due care for itrs threads and rusting by applying grease and cotton waste. as per the structural engineers instructions & drawing |
| 28 | Providing & Fixing HST4-R Stainless steel wedge anchor Stud anchor HST4-R M20x200 5-60 #2329126. Anchor Dia- 20MM, Anchor Length - 200MM, Pack Of 5 Fastners. Product Link -(https://www.hilti.in/c/CLS_FASTENER_7135/CLS_MECHANICAL_ANCHORS_7135/r1847 6741?CHA_GLOBAL_ANC_SIZE=M20&CHD_ANCHOR_LENGTH=200%20mm&itemCode=2329126&salespackquantity=5&activeTab=preconfigured-kits-tabs) |
| 29 | Removing existing Glass Facade & providing plywood packing |
| 30 | Removing & Reinstalling Existing Gas Bank room due to erection ofColumn C3 as per the structural drawing. |
| 31 | Removing & Refixing existing B.E.S.T Cables and reinstalling as original |
| 32 | Removing Existing Fire Tank safely and filling the space as directed |
| 33 | Existing fire vertical Pipes and other related pipes to be relocated |
| 34 | removing existing Inspection Chamber and shifting and providing new inspection Chamber with required drainage pipes |
| 35 | Repairs to Existing Water Tank Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysDec 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender