Tender For Replacement Of Existing Fire Alarm System Including 5 Years Aicmc Work At Nitb At Raja Bhoj Airport, Bhopal.
Tender Value
82.44 Lakhs
Estimated cost
Bid Submission
14 Dec 2026
22 days left
EMD
1.64 Lakhs
Bank guarantee accepted
Document Fee
1120
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of Existing Fire Alarm System Including 5 Years Aicmc Work At Nitb At Raja Bhoj Airport, Bhopal.
BOQ
| Sl. No. | Item Description |
| 1 | SH-I : SITC Work including 01 year DLP.Supply, Installation, Testing & Commissioning of 8 Loop Analog Addressable Fire Alarm Control Panel having the capacity of 250 devices / detectors per loop in any combination. The panel shall have 32 bit Central processor with 5000 Event History logging with On Line & Offline reports and having large, 6\\" (15.2 cm) (1200 -x- 800 pixel) color liquid-crystal display (LCD), Touch Screen operation and LEDs for displaying system status. All the events shall saved as history file in non-volatile memory (EEPROM). The panel shall have the Touch Screen Graphical Display panel. The panel shall have inbuilt power supply having charging, Lead Acid battery. In case of networking, the panel shall have network card included inside the panel for RS485 communication with other display devices like Graphic screen, repeater panel etc. The panel shall support degrade mode operation and shall have battery backup of 24 hrs in normal condition and 60 minutes in Alarm condition. The panel shall support programmable relays for controlling lifts, staircase pressurizations fans, lift shaft and lift lobby pressurization fans, AHU's, ventilation fans, fire pump, monitoring of fire sprinkler and fire hydrant pump controlled by programmable logical equatoins. The panel shall be supplied with all accessories, power supplies in the required quantities as per site requirements for all types of field devices to make the system fully operational. The panel shall have BACnet card for integration along with graphic user interface with fire detetion with two bay communication panel and voice over IP along with all accesarries. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
| 2 | Supply, Installation, Testing & Commissioning of Active Repeater Panel. The panel shall be able to give details of all fire and fault and Isolation conditions of addressable units of main Fire Alarm panel via the address codes. The panel shall have a LCD display and having 160 Characters in the display with system function keys like system reset, Alarm acknowledge, Alarm Silence, Trouble Acknowledge, internal buzzer etc. Repeater Panel shall have proper mountig back box and cable as required. |
| 3 | Supply, Installation, Testing and Commissioning of Intelligent Addressable Smoke/optical detector with photoelectric, thermal, and false alarm resistance along with standard base. The detector shall have tri color LED, Green for Normal, Amber/yellow for trouble and Red for alarm with 360° viewv microprocessor circuitry with error check; detector self-diagnostics and supervision program. Shall be Polarity Insensitive, with built-in isolator Superior electromagnetic interference (EMI) and radio-frequency interference (RFI) immunity. The rate shall include other accessories to complete the installation of the Detector.Detector shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. |
| 4 | Supply, Installation, Testing & commissioning of intelligent addressable multi criteria detector {Smoke + heat} with inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. The detector shall have tri color LED, Green for Normal, Amber/yellow for trouble and Red for alarm with 360° viewv microprocessor circuitry with error check; detector self-diagnostics and supervision pras required and to be installed below / above false ceiling, roof and concealed space and as per enclosed specifications complete as required. (Cost of plug in common base shall deemed to be included in cost of detectors) |
| 5 | Supply, installation, testing and commissioning of Response Indicator for getting fire indications of detectors i/c mounting boxes installed above/below false ceiling area interconnecting to loop cable complete as required. |
| 6 | Supply, Insallation, Testing and Commissioing of Beam Smoke Detector. It shall be used for High Ceiling application with a detection range upto 100 mtrs having manual & auto sensitivity settings. It shall have transmiter and reciever of IR rays and installed on the SLC circuite & communicate with the panel with/without any interface module. The rate shall include other accessories to complete the installation of the Detector. |
| 7 | Supply, Installation, Testing and Commissioning of Intelligent Addressable Monitor modules with built in dual isolator/ polarity insensitive and Advanced troubleshooting function. For monitoring purpose with Tri color LED for status (Green for Normal, Amber for Trouble and RED for activation). The Single - Input version are each designed to monitor a normally open (N.O) or (N.C) normally closed dry contact. Modules for monitoring status like flow Switch, Tamper Switch, Sprinklers and apartment fire alarm status. The rate shall include other accessories to complete the installation of the system. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every Module to comply the same without any extra cost. (For Sprinkler Flow Switches and door holders) |
| 8 | Supply, Installation, testing and commissioning of Intelligent Addressable Interface Control/Relay Modules with built in dual isolator/ polarity insensitive and Advanced troubleshooting function. For monitoring purpose with Tri color LED for status (Green for Normal, Amber for Trouble and RED for activation). The Single - Input version are each designed to monitor a normally open (N.O) or (N.C) normally closed dry contact. Modules for activating hooters, over riding access door commands with all the mounting accessories complete as required. One CM shall provide one activation signals. The rate shall include other accessories to complete the installation of the system. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every Module to comply the same without any extra cost. (For AHU & Staircase Pressurization Fans, Hooters / Sounders / Strobes etc.) |
| 9 | Supply, Installation, Testing & commissioning of intelligent addressable Manual call station (Resettable pull / push type) suitable for semi flush mounting,with inbuilt fault isolator / isolator module with double gang outlet box, equipment for key operated test reset lock, electronic or rotary switches for address setting. Manual pull station shall be connected with two wire to SLC loop of Fire Control Panel. Cover shall be made out of LEXAN (or polycarbonate equivalent) with clear operating instruction and the word \\"FIRE\\" appearing on the front complete with connections etc. as required and as per enclosed specifications. |
| 10 | Supply, installation, testing and commissioning of addressable Hooter-cum- strobe with inbuilt fault isolator / isolator module with adjustable sound level in the range of approx min. 80 db to Max. 120 db at 1M distance complete with termination etc. as required and as per enclosed specification. |
| 11 | Supply of the manufacturer provided Graphics user interface Software Package for complete interactive control of the Fire Alarm System. The System must be both flexible,scalable with secure.and shall also possible to despatch systems dialler and or event dispatching via e-mail,SMS via mobile phone. The system shall be upgradable with a multi-user option/client and server configuration complete as per specifications and as required. In the system, the configuration tool shall be launched when the user selects to edit a graphical maps. The systems should support wide variety of formats such as AutoCAD,pixel-based such as .BMP and .JPEG and Windows metafiles. The software need to provide layer and depth control with zoom feature.The system shall also confirm to the UL approvals. The system shall be based on client server architecture and shall run under Microssoft Windows 7 64 bit or Windows Server 2008 R2 64 bit- with Service Pack 1 or later. Microsoft office 2007 or later, Microsoft office Primary Interlop Assemblies 2007 or later. The Minimum PC configuration is I7 CPU, 16GB RAM, 500 GB hard drive 7200 RPM (If using SQL Express) or 1.5 TB if using SQL Server),Video card (1920x1200 Pixels or More)USB port for Dongle.LAN connections 10/100/1000MB Ethernet. |
| 12 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 13 | Note: Rates not to be quoted by agency for SH-II i.e. AICMC part. it will be calculated automatically as per the pre-fixed percentages mentioned at GTT Clause No. 43, Page No. GTT-10 & GTT-11.SH-II : All Inclusive Comprehensive Maintenance Contract (AICMC)AICMC of Fire Alarm System (as per item no. 1.00 to 12.00) which include routine, preventive, breakdown maintenance, bi-monthly preventive maintenance visit by OEM / OEM authorized channel partner, attending any number of breakown calls during the month as and when required, and repair / replacement of wornout items with minimum downtime etc as per special conditions / specifications enclosed. |
| 14 | For First Year After 01 Year DLP (3% of SITC Cost as per BOQ Item No. 1.00 to 12.00) |
| 15 | For Second Year (4% of Cumulative enhencement on First Year AICMC Cost) |
| 16 | For Third Year (5% of Cumulative enhencement on Second Year AICMC Cost) |
| 17 | For Fourth Year (6% of Cumulative enhencement on Third Year AICMC Cost) |
| 18 | For Fifth Year (7% of Cumulative enhencement on Forth Year AICMC Cost) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysDec 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender