Tender For Providing Of Otm Accn At Fasf Kanchrapara Under Ge Barrackpore

BOQ

Name of Work:- PROVN OF OTM ACCN AT FASF KANCHRAPARA UNDER GE BARRACKPORE
Sl. No. Item Description
1NOTE (Applicable for all items) :-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.2. It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer.
2Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as directed.
3Demolition of reinforcement concrete, Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as directed.(reinforceent cut as required to facilitate demolition)
4Separating, scraping and cleaning of reinforcement complete all as direted. (Demolition of concrete measured separately)
5Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
6Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as directed.
7Rough excavation, n. exc 1.5 m deep and getting out soft/loose soil complete all as directed.
8Removing excavated soil to a distance exceeding 250 metre but not exceeding 500 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
9Removing excavated soil to a distance exceeding 500 metre but not exceeding 1.00 Km and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
10Removing excavated soil to a distance exceeding 50 metre but not exceeding 250 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
11Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as directed.
12Surface dressing n exc 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as directed.
13Excavating over areas, n exc 1.5 m deep and getting out soft and loose soil complete all as dirceted.
14Excavating over areas, exc 1.5 m deep but n.exc 3.00 m deep and getting out soft and loose soil complete all as dirceted.
15Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm on soft/loose soil complete all as directed.
16M&L for PCC 1:3:6, C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete and base of floor complete all as specified and directed.
17M&L for PCC 1:4:8, D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete and base of floor complete all as specified and directed.
18M & L for RCC M-30 (Design Mix)using 20mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
19M&L for RCC M-30 grade in walls,retaining walls,basement wall,ballast walls and the like,any thickness,above top of footings,incl. attached pillasters and buttresses complete all as specified and as directed.
20M & L for RCC M-30 (Design Mix) using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed.
21M&L for RCC design mix M-30 with 20mm graded aggregates for beams,cantilevers, bressum-mers,lintels over 1.5m span complete all as specified and as directed.
22M&L for R.C.C. design mix M-30 for slab supported on walls ,beams and columns in floors,roof,landing,balconies,canopies,deck slab and in shelves complete all as specified and as directed.
23Supply only and add to Item No 18.00 to 22.00 of high performance water reducing super plasticising admixture for producing pumpable concrete of high grade strenght low permeabilty high early strenght,improve workability dense and close textured concrete with reduceed porosity high cohision for reducing risk of saggegation all as specified and directed.
24M&L for TMT bars ,10mm dia and over, cut to length bent to shape required,incl.cranking, binding spirally for hooping for columns,hooking ends and binding with and incl. mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & as directed.
25M&L for TMT bars ,05mm dia and above upto and incl10 mm dia in stirrups,spacers and binders,cut to length,bent to shape reqd,incl cranking,binding spirally for hooping for columns,hooking ends and binding with and incl. mild steel wire(annealed) not less than 0.9mm dia or securing wih clips complete all as specified & as directed.
26M&L for Formwork rough finished surface of concrete , to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
27M&L for formwork to faces of walls,retaining walls,abutments,parapets and staircase railing and similer work including attached pillasters buttresses etc vertical or to better complete all as specified and directed
28M&L for formwork to sides and soffits of floor or roof beam , beam haunching, girders, bressummers, lintels, cantilevers, shelves including sup -ports Overhangs ets with flat surface complete all as specified & as directed..
29M&L for formwork to soffits of suppended slab such as roof slabs, floor slab, landings and similar works,not exc 200mm thick complete all as specified & as dirceted.
30Material and labour for fly ash brick work with old size bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
31M&L for bringing of excavated earth, approved best quality from out side MOD land up to 25 Km distence for filling of building foundation all as specified and directed.Note :- Rate shall be including royality
32M&L for 30mm thick granolithic concrete 1:1:2 floor topping laid over cement concrete subfloors etc and finished and treating with three dressing of sodium silicate solution complete all as specified and directed .
33M&L for rendering 5mm thick in cement mortar 1:3 fair faces of brick work or concrete surfaces for ceiling finished even and smooth without using extra cement complete all as specified and directed.
34M&L for rendering 20mm thick in two layer on fair faces of brick work or concrete surfaces in cement mortar 1:4 using using water proofing compound @ 200Ml by wt of cement per bag for finished even and smooth without using extra cement complete all as specified and directed. ( WPC will be measured and paid separately)
35M&L for rendering 15mm thick in two layer on fair faces of brick work or concrete surfaces in cement mortar 1:4 using using water proofing compound @ 200Ml by wt of cement per bag for finished even and smooth without using extra cement complete all as specified and directed. ( WPC will be measured and paid separately)
36M&L for rendering 15mm thick in cement mortar 1:6 on fair faces finishes of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
37M&L for rendering 5mm thick in cement mortar 1:4 fair faces of brick work or concrete surfaces for walls finished even and smooth without using extra cement complete all as specified and directed.
38Supply only liquid water proofing compound all as specified and directed.
39M&L for two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali and fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre /10sqm over new surface including preparation of new surfaces complete all as specified & as directed.
40M&L for two coat of fire resisting paint over a coat of primer on to new plaster wall surfaces including preparation of surface complete all as specified and directed.
41M&L for two coat of fire resisting paint over a coat of primer on to new plaster celing surfaces including preparation of surface complete all as specified and directed.
42M&L for APP based polymeric membrance minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyster nonwove fabric (Wt not less than 150 gms / sqm) laid on primed surface with side over lap of 80 mm and end overlap of 100 mm using bitumen torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum Paint over it complete all as specified & directed .
43M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20kg per sqm including cleaning surface complete all as directed.
44M&L for sand filling under floors or in foundation including watering and consolidation all as specified and directed.
45M&L for MS work as in door and ventilator for frame, hooks (stay), heavy, top and bottom latches, for large gates; hook and pintle hinges: large hasps and staples; hand made sliding bolts; clamps; hold fasts; and similar small articles etc conforming to Fe-290 Gde-E-165 all as specified and directed
46M&L for M S Framed work as in doors or gates of angle,Ismc or other section with MS plate/sheets rails,braces, etc., complete, drilled for fixing of MS steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (inclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
47M & L for preparation of new steel surfaces of any description over 10cm in girth or width & applying two coats of Fire resisting paint over a coat of red oxide etc complete all as dirceted.
48Material and Labour for Precast reinforced cement concrete type B0, 1:2:4 (12.5 mm graded aggregate) in door and windows frames, any size, single or double rebated, including arrangement for fixing of hinges and fixtures as required complete all as specified & as dirceted.
49S&F for Welded steel wire fabric to wood or steel members weight per sqm exc 4.0 kg/sqm complete all as specified and directed.
50M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces for walls rendering even and smooth without using extra cement complete all as specified & as dirceted.
51M&L for two coat of Cement base paint over a alkali resistant priming paint to new exterior wall surfaces described after preapartion all as specified and directed.
52S&F of 75mm dia PVC(SWR) pipes single socketd in any length in retaining wall weep hole complete all as directed.
53M&L for forming embankment including raising ( or lowering) earth spreading in layers n.exc 30cm thick watering,ramming/rolling and finishing to required size shape etc N.exc 1.50m high from base all as specified and directed.
54M&L for forming embankment including raising ( or lowering) earth spreading in layers n.exc 30cm thick watering,ramming/rolling and finishing to required size shape etc Exc 1.50m high to N.Exc 3.00m high from base all as specified and directed.
55M&L for forming embankment including raising ( or lowering) earth spreading in layers n.exc 30cm thick watering,ramming/rolling and finishing to required size shape etc Exc 3.00m high to N.Exc 4.50m high from base all as specified and directed.
56M&L for forming embankment including raising ( or lowering) earth spreading in layers n.exc 30cm thick watering,ramming/rolling and finishing to required size shape etc Exc 4.50m high to N.Exc 6.00m high from base all as specified and directed.
57Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 metre in depth for foundation etc and for manholes , relaying of pipes etc n.exc. 10 Sqm on plan and n.exc. 1.5 metre depth and getting out in soft/loose soil complete all as specified and directed.
58M&L for 600mm dia bored cast in situ piles 18 mtrs in soil and getting out disposal of soil to a distence 50mtr using DMC method(direct mud circulation) complete all as directed.
59M&L for RCC M-30(Design mix) using 20mm graded stone aggregate as in chajja complete all as specified and directed.
60M&L for formwork to sides of pillars,posts,struts,piers,columns and stanchions with flat surface.
61M&L for mixing of fly ash, clinker & stone dust in proportion of 1:3 :6 ( i .e 10% Fly ash, 30% Clinker and 60% Stone dust materials) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete as directed.
62Material and labour for hardcore with broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface as required complete all as specified and as directed.
63M&L for Polythene film,400 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m all as specified and directed
64M&L for 100mm thick cement concrete type C2 1:3:6 (40mm graded stone aggregate) complete all as specified and directed
65M & L for 200mm thick cement concrete type A-1, 1:1.5:3 ( 20mm graded aggregate) finishing cement concrete surface fair and even, PVC strips,Non metalic hardner of top surface with treated with sodium silicate et as per MES specification all as specified and directed ( NOTE : PVC strips, Non metalic Hardner & Sodium silicate Shall be measured and paid separately )
66Treating cement concrete or granolithic concrete surface with three derssing of sodium silicate solution complete all as dirceted.
67Supply only non metalic hardner as using top of cement concrete surface ( 1Kg of Non metalic hardner covered to 0.16 Sqm ) complete all as directed.
68Supply only 200mm width plastic deviding strips 1.5mm thick inserted in position confirm to design in concrete complete all as directed.
69Supply and fix mild steel of grade Fe-290 (Grade E-165) in framed work such as grills, grating etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders; ramed balusters; walk ways; railings; framework of water tanks and similar works etc complete all as specified and directed.
70S&F for wire netting of galvanised steel wire 1.4mm dia fixed with tinned tacks of wire stapples of mesh size 12mm
71S&F for bands,straps supports or stays for rainwater ventilating pipes including bolts if reaquired hooks (Stay) heavy for large gates ,pintal hinges ,large heasp and staple,hold fasts clampsmwall ties;hooks for hanging fans ect specified and directed
72S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete with Fe410W(Gde-E-250) Qulaity-A all as spicified and directed.
73Material & labour for 150mm PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base floor complete all as specified & as directed.
74M&L for pavement quality concrete (PQC) of minimum 28 days field fluctural strenght of 45Kg/Sqcm or 4.5 Mpa duarable gradationas per table 3 of IRC 15:2017 coarse aggregate of clean hard string,dense non-porous and durable pieces of crushed stone on graval fine aggregate of clean natural sand on crushed stone sand or combination of both using miinimum 360kg/Cum of cement with non-circuler virgin synthetic fibre of 12-18 mm lenght specific gravity 1.34 to 1.39 UV stable alkali resistant with equivalent dia 15-40micron minimum melting temparature as 240 celcious and minmum tensile strnght of 300Mpa and at the rate as specified by the manufacturer PQC laid spread and compected with slip form paver of minimu 7.50m width, including curing and tining by texturing cum curing mechine complete all as specififed and directed.Required surface texturing to be done as specified in cluase-r,10.1.14 and table -9 of IRC 15-2017
75M&L for 10mm thick plastering in Cm 1:4 concrete surfaces of walls and making surfaces even and smooth without using extra cement complete all as directed.
76M&L for Laying polythene paper 150mm micron laid on a concrete surface @ 0.30 to 0.50 kg per Sqm with laps as specified
77M&L for forming 20mm thick expansion joints (TRANVERSE) filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound cold applied polysuphate/polyurethane joint sealent, thickness of concrete slab in 250mm and provided with 20mm dia mild steel double bar 50CM long (25CM in each slap) with ferrulles, speced at 300mm centers.including boring formwork and performed fliier for dowels
78Forming contraction (Dummy) joints with diamond cutter, 65mm deepX10mm wide filled with sealing compound with grade \\"A' filler before priming the surface complete as specified and directed.
79M&L for forming contruction joints 65mm deep x 10mm wide filled with sealing compound grade 'B' cold applied polysulphide/Polyurethane joints sealent,thickness of concrete slab 250mm thick complete all as directed.
80Supply only polyester tranguler synthetic fibre as secondary reinforcement mixed in cement concrete (it shall be uniformly mixed at the rate of 0.25% or at the rate as per manufacturer's instructions by weight of cement ) complete all as directed.
81M&L for PCC 1:2:4 Type B1 (20mm graded aggregate) as in surface channel and drains complete all as directed.
82Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as directed.
83M&L for TMT bars,5mm dia and over upto and including 10mm dia, cut to length bent to shpe required and binding with and including mild steel wiore(annealed) not less than 0.9mm dia in strrups,spacers and binders etc complete all as directed.
84M&L for cement concrete sub base 75mm thick type D-2 1:4:8(40mm graded aggregate) complete all as directed.
85M&L for for Precast RCC solid blocks with cement concrete type B0(1:2:4) using 12.50mm graded aggregate for dunnage blocks complete all as directed.
86S&0.63mm thick plain galvanised mild steel sheeting over dunnage with grade of zinc coating 275 complete all as directed.
87M&L for mild steel rod for flifting and shfting of RCC dunnage blocks confirming to Fe Gde E-165 complete all as directed.
88Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as directed.
89Material and labour for PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete.
90Supply & fix Mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats etc conforming to Fe 410-W (Gde-E- 250) complete all as directed.
91Supply & fix Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as directed.
92Supply and fix Pre- painted galvatume aluminium zinc coating GI based plain steel sheet 0.53mm thick (TCT) with base metal thickness of 0.455mm (0.45mm BMT min),of RED colour having tensile strength of 550 Mpa minimum yeild strength as in roof covering of profile as approved by GE, fixed with seif tapping screws complete all as specified and as directed.
93Materials and labour for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by the Engr-in-Charge.
94Materials and labour for preparation of new or previously untreated steel surfaces of any description n.exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by the Engr-in-Charge.
95Rolling and consilidating road formation surfaces in cutting with 8 to 12 tonne power roller including watering and consolidating to the required level, gradient as required complete all as specified and directed.
96M & L for 150 mm spread thick Soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete as directed
97M/L 150 mm thick (compacted thickness in Two layers) water bound macadam( WBM), with granite trap or basalt stone aggregate with coarse aggregate of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size) using mechanical paver as specified,rolled & consolidated as specified to required gradient and camber complate all as specified & directed.
98M&L for sand cusioning under floors including watering and consolidation over WBM sub base complete all as specified and as directed.
99Supplying and laying 400 micron thick HDPE sheet (Virgin Quality) water proof, wrinkle free without puncture having minimum weight 390gm/Sqm over tack coat/sand cushion as specifed in the design with overlap between adjacent strips and at transverse joints as minimum 300mm complete all as specifed and directed.
100M&L for 200mm thick Pavement Quality Concrete (PQC), design mix , in pavement / hard-standing of flexural strength 40 Kg/Square centimeter in filed using 400 kg of cement per cubic metre complete all as specified and directed.NOTE :(a) Rate shall be included of mixing only non circular synthetic monofilament polyster fibre reinforcement @ 0.20 % and plasticisng agent @ 0.38 & by weight of cement content.(b) Rate shall include use and waste of side forms for laying pavement concrete / hard standing / road in bays between joints & contraction expansion joint / or between the two contraction joints for thickness of pavement upto and including 25 cm(c) Non-circular synthetic monofilament polyster fibre reinforcement and admixture (super plasticizer) shall be measured and paid separately.(d) Forming construction , dummy and expansion joints shall be measured and paid separately under respective items.(e) No deduction shall be made in computing concrete quantity for construction and dummy/contraction joints. However deduction shall be made for expansion joints.(f) No price adjustment shall be applicable if additional quantity of cement content used / approved in execution of work under this item however minus price adjustment shall be made for less quantity of cement used in the work @ Rs. 6.00 Per Kg
101Supply only Non circular, virgin, synthetic, monofilament polyster fibres of length 12-18mm , specific gravity 1.34-1.39, UV stable, alkali resistant, equivalent dia 30-35 micron , melting point 240*C-260*C and minimum tensile strength 300 Mpa be used up to 0.20% by wt of cement or as per manufactrer instruction/design mix in PQC as secondary reinforcment. Note : (a) All properties/specifications shall meet test parameters as per IS 16481-2016.
102Supply only High performance water reducing super plasticising admixture (Fosroc Conplast SP500) for producing pumpable concretre of high grade strength, low permeablility, high early strengh, improve wokabiliy, dense and close textured concrete with reduced porosity and high cohesion for reducing risk of segregation and bleeding complete all as specified and directed.
103Finishing surface of concrete pavement by belting and finally brooming when concrete still remains green complete all as specified and as diected.
104Forming 12 mm thick Expansion joints filled with pre-formed polyetjylene joint filler and top 30 mm primed and sealed with sealing compound, Grade 'A' for concrete pavement 250mm complete all as specied and directed.
105Forming Construction Joints with Diamond cutter, 30mm deep x 10mm wide, filled with sealing compound Grade A before priming the surface complete all as specified and as directed.
106M & L for two coats painting lines,dashes,arrows, letters etc on roads pavements and the like n exc 10cm wide with road marking paints, white or golden yellow
107M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
108M&L PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in bed of 600mm bore of pipe (RCC hume pipe) including packing under and completelly surrounding pipe copmplete all as specified & as dircted.
109Material and labour for Reinforced concrete pipes ,class NP3,laid and jointed complete with collars 600 mm bore complete all as directed.
110M& L PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping, bed plate kerbs including weathering slightly rounded or chamfered angles and throating etc as directed.
111M&L for rendering 15mm thick in cement mortar 1:4 on fair faces finishes of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
112Material and labour for (concelaed Type) point wiring including necessary chese cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including steel conduit with all accessories and sunk modular MS box for mounting of fittings like switch, socket and fan regulator with modular inner plate and cover plate and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge
113Material and labour for (concelaed Type) point wiring including necessary chese cutting of wall for one 16 Amp socket point with 4.00 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 4.00 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including steel conduit with all accessories and sunk modular MS box for mounting of fittings like switch, socket and fan regulator with modular inner plate and cover plate and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge
114Supply and fixing sub-main wiring flame proof with PVC insulated & unsheathed two run of 4 Sqmm single core multi stranded copper conductor cable Halogen Free Flame Retardant (HFFR) , 1100 Volt grade alongwith one run of 4 Sqmm PVC insulated & unsheathed copper conductor cable (HFFR), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through steel conduit complete all as specified & as directed.
115Supply and fixixing switch flame proof rotary type with termination box in LM6, 16 Amps, single pole 250 V complete all as specified & as directed.
116Supply and fixixing flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 Amps, 250 V 2Pin + earth complete all as specified & as directed.
117Supply and fixing flame proof cum water proof LED bulk head light fitting of 20 watts, certified by CRMI, suitable for gas / vapour group of IIA & IIIB, Zine 1 & 2 as per IS-2148 (1981) and IS-2206 Part I having IP 66 degree of protection, cast aluminium alloy material and heat and impact resistance toughen `A' clear glass having anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connected up with three core flexiable copper conductor cable with suitable size complete all as specified and as directed.
118Supply and fixing flame proof LED light fitting 40 watts, certified by CRMI, suitable for for gas / vapour group of IIA & IIIB, Zine 1 & 2 as per IS-2148 (1981) and IS-2206 Part I having IP 65 degree of protection as per IS-2147 (1962) of die cast aluminium alloy material LM-6 construction, light grade epoxy powder coated finish of shade number 631 as per IS-5 having provisioning of one number internal earth and two number external screws of M4/M5 size `O' ring endless neoprene rubber gasket, stainless steel hardware, two number 3/4 inch cable entry, internal driver type epoxy powder coating, clear heat resisitance well glass including connecting up with trhree core flexiable copper conductor cable with suitable size complete all as specified and as directed.
119Supply and fixing flame proof distribution board, flame proof as certified by CRMI, SPN 12 way with DIN rail. suitable for isolator, MCBs and ELCBs, suitable for group-I, IIB as per IS-2148(1981), IP-65 as per IS-2147(1962), cast aluminium alloy LM-6 construction, light grey epoxy shade No 632 of IS-5 powder coating having `O' ring endless neoprene rubber gasket, stainless steel hardware in external steel construction complete all as specified and as directed. NOTE :- Isolators, MCBs and ELCBs shall be measured and paid separately
120Supply and fixing MCB SPN `C' curve, 40 Amp rating suitable for 230 Volts complete all as specified and as directed.
121Supply and fixing MCB SP `C' curve, 6-32 Amp rating suitable for 230 Volts complete all as specified and as directed.
122Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed
123Supply and fixing LED building security light fitting 35 watts , 230 v, AC outdoor type with high pressure die cast aluminium housing heat resistant complete with driver, lamp bracket with impact and corrossion resisitant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and as directed.
124Supply and fixing LED street light fitting 90 watts , 230 v, AC outdoor type with high pressure die cast aluminium housing heat resistant complete with driver, lamp bracket with impact and corrossion resisitant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and as directed.
125Supply, fabricating and fixing street light bracket made out of GI pipe meduim grade 1.00 mtr long, 32 mm bore dia bent to shape as directed including clamps made out of 40mm x 6mm flat for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
126Supply, testing, commissioning and fixing of Temperature & Humidity Data Logger with the following specification :(a) Max / Min : Temperature reading over 0 to 100 % RH : 40 degree celsius to 70 degree celsius.(b) Measurement ranges by PC with USB interface with data card and LCD monitor(c) Memory for 32700 readings (16350 temperature and 16350 humidity readings) with long life battery pack with accessories including locking arrangement complete with fixing on wallNote : - URP (each 7 Chambers) 2 Nos = 14 Nos & ESH Storage - 1 No
127Supply and fixing steel tubular swaged poles, type 410 SP 55 (Overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, painting black & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified and as directed.Note :- Excavation and earthwork and PCC shall be measured and paid separately under respective items
128Supply and fixing steel tubular swaged poles, type 410 SP 31 (Overall length 9.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, painting black & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified and as directed.Note :- Excavation and earthwork and PCC shall be measured and paid separately under respective items
129Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced to and including copper strip of size 20 x 3mm from earth electrode to test point/equipment or upto 7.5 metres whichever is less by means of bolts, nuts, check nut and washers earthing lead to be protected by galvanised iron pipe of 20mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade) watering pipe , wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed
130S&F earth contunity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required with using copper strip 32 x 6 mm from top of poles to test point complete all as directed.
131S&F Air termination , single pointed, copper rod 12 mm dia and 300 mm long fixed in position complete all as directed.Note :- On top of pole 12 Nos for URP and 05 NOs for ESH
132S&F Test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as directed.
133Supply and fixing Aluminium Conductor Steel Reinforced (ACSR) of required sizes (Ferret-size 6/1 x 3.00 with permissible Sags and providing Jumper, etc., fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., complete all as specified and as directed.NOTE: Cost of Binding Wire is deemed to be included in the QUOTED UNIT RATE.
134M&Lfor Stay assembly complete with accessories as shown in electrical plate No. 1 of MES Schedule Part-I diameter of stay rod 20 mm, size of plate 230x230x6mm omplete all specified and as directed.Note :- loop type insulator , stay clamp, excavation and concrete shall be measured and paid separately
135S&F Loop type insulator, vitreous porcelain, white, brown or green Small size, with overall dimensions 90 x 140mm, clearance of hole 25.5mm dia complete all as specified as directing.
136M & L for MS Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of Aluminium paint, complete all as specified as directing
137Excavation in trenches not exc. 1.5 metre wide and exc. 1.50 metre and n.exc 3.00 metre in depth for foundation etc and for manholes , cable etc n.exc. 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
138Material and Labour fro removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge
139Taking up for shifting old CI/GI/DI pipes and connected gate valves etc of any size from trenches of size 80 dia complete all as directed.
140Relaying of pipes of 80 mm bore dia with all fittings after cleaning internal surfaces of serviceable pipes by using wire brush and cleaning throughly with fresh water and taking out mud / soft deposited inside the pipes complete all as directed.
141Supply, laying, jointing, fixing, testing and commissioning of Ductile Iron (DI) pipes 100 mm bore , spigot and socket (S/S) ends, Class K-7, conforming to IS:8329 / ISO:2531, including all fittings as required complete, pipes shall be laid in trenches or in open execution, as directed at site, lowering, aligning, jointing using rubber gasket (push-on joint) or approved jointing material, including cutting of pipes, deflection at joints where required, and thrust blocks / anchor blocks wherever necessary, includes hydrostatic pressure testing, and making good disturbed surfaces, complete all as specified and as directed by the Engineer-in-Charge of following sizes of pipes.
142Supply, laying, jointing, fixing, testing and commissioning of Ductile Iron (DI) pipes 150 mm bore , spigot and socket (S/S) ends, Class K-7, conforming to IS:8329 / ISO:2531, including all fittings as required complete, pipes shall be laid in trenches or in open execution, as directed at site, lowering, aligning, jointing using rubber gasket (push-on joint) or approved jointing material, including cutting of pipes, deflection at joints where required, and thrust blocks / anchor blocks wherever necessary, includes hydrostatic pressure testing, and making good disturbed surfaces, complete all as specified and as directed by the Engineer-in-Charge of following sizes of pipes.
143Supply, laying, jointing, fixing, testing and commissioning of galvanized mild steel (GI) pipes 40mm bore dia , Medium class, conforming to IS:1239 (Part-1), including all GI fittings such as elbows, bends, tees, reducers, sockets, unions, nipples, caps, plugs, etc., complete, pipes shall be laid in trenches, walls, floors or ceilings, either concealed or exposed (open execution), as directed at site, including cutting, threading, jointing with approved jointing compound (white lead / PTFE tape), fixing with clamps, hooks, brackets, hangers and supports, and making all joints leak-proof, making good all disturbed surfaces, pressure testing of the pipeline, flushing and commissioning, including all labour, materials, tools, scaffolding and accessories, complete all as specified and as directed by the Engineer-in-Charge.
144Supply, laying, jointing, fixing, testing and commissioning of galvanized mild steel (GI) pipes 25mm bore dia , Medium class, conforming to IS:1239 (Part-1), including all GI fittings such as elbows, bends, tees, reducers, sockets, unions, nipples, caps, plugs, etc., complete, pipes shall be laid in trenches, walls, floors or ceilings, either concealed or exposed (open execution), as directed at site, including cutting, threading, jointing with approved jointing compound (white lead / PTFE tape), fixing with clamps, hooks, brackets, hangers and supports, and making all joints leak-proof, making good all disturbed surfaces, pressure testing of the pipeline, flushing and commissioning, including all labour, materials, tools, scaffolding and accessories, complete all as specified and as directed by the Engineer-in-Charge.
145Supply and fixing, connecting, testing and commissioning of double flanged non rising / rising spindle sluice valve of 150mm dia bore of PN 1.6 in pressure line and PN 1.0 in delivery line, as per IS 14846 and IS 1538, cast iron as per IS-210 Gr FG260, SS spindle, bronze body seat ring, bronze wedge ring, gland packing-jute & hemp, natural rubber gasket, bronze stem nut with spinning wheel complete including taking down old existing unserviceable sluice valve complete all as directed.
146Supply and fixing, connecting, testing and commissioning of double flanged non rising / rising spindle sluice valve of 100mm dia bore of PN 1.6 in pressure line and PN 1.0 in delivery line, as per IS 14846 and IS 1538, cast iron as per IS-210 Gr FG260, SS spindle, bronze body seat ring, bronze wedge ring, gland packing-jute & hemp, natural rubber gasket, bronze stem nut with spinning wheel complete including taking down old existing unserviceable sluice valve complete all as directed.
147Supply and fixing, connecting, testing and commissioning of 40mm dia bore gun metal globe valve or gate valve, as specified, having screwed ends on both sides, complete with iron hand wheel, union, long screw with check nut, suitable for use with iron pipes, including taking down and removing the existing gate/globe valve, dismantling of old connections, cleaning of pipe threads, supply of new valve, jointing with approved jointing material (white lead / PTFE tape), alignment, tightening, and making all joints leak-proof, testing the valve under working pressure for proper operation, and making good disturbed portions, complete all as specified and as directed by the Engineer-in-Charge.
148Supply and fixing, connecting, testing and commissioning of 25mm dia bore gun metal globe valve or gate valve, as specified, having screwed ends on both sides, complete with iron hand wheel, union, long screw with check nut, suitable for use with iron pipes, including taking down and removing the existing gate/globe valve, dismantling of old connections, cleaning of pipe threads, supply of new valve, jointing with approved jointing material (white lead / PTFE tape), alignment, tightening, and making all joints leak-proof, testing the valve under working pressure for proper operation, and making good disturbed portions, complete all as specified and as directed by the Engineer-in-Charge.
149Supply and fixing, connecting, testing and commissioning of 100mm bore dia cast iron Non return valve verticle / horizontal type with gasket bolts, nuts and washers conforming to IS-5312, PN 1.6 in position complete all as specified & as directed.
150Supply and fixing, connecting, testing and commissioning of 150mm bore dia cast iron Air release valve double ball type comnfirming to relevent IS with gasket bolts, nuts and washers in position complete all as specified & as directed.
151Supply and fixing, 25mm bore dia Ball brass valve, high pressure, with polythene float and flynut screwed for iron pipe or brass ferrule complete all as specified & as directed.
152Supply & Fixing SMC kiosks box / PVC junction box for poles of size 350mm x 270mm x 200 mm or nearest higher size made of polycarbonate with IP 65 degree of protection (EN60529), dust proof, water tight, shock proof, fire retardant, suitable for three phase 415 volts AC supply with 04 Nos Aluminium bus bar rating 63 Amps with one No MCB 10 Amps, SP with internally embedded gasket fitted with heat treated bakelite for terminals block and PVC Glands for cable entry including making fixing arrangement with 9 mtr long swaged pole with flat iron clamp complete all as directed.
153Supply & Fixing 1100 volts grade heavy duty cable PVC insulated copper conductot FR round flexiable in street light connection from pole juction box at bottom of street light fixed on 9mtr long sewaged pole by making two holes with welding machine for inserting cable of size 1.5 sqmm 3 core multistranded and making necessary connection complete all as directed.
154Supply and fixing Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20 x 15 cm size complete all as specified and as directed.
155Disconnecting all electrical connections and earth strip at existing transformer all connected accessories / cables and shifting of 11 KV/0.433 volts 63 KVA capacity transformer and transporting safely by hydra / lifting vehicle including providing suitable carrying vehicle to proposed power house or MES yard complete all as directed by Engr-in-Charge.
156Supply,installation, testing and commissioning of pole mounted (special application) transformer of capacity 100 KVA step dowm, outdoor type, 3 phase, 50 Hz, AC oil immersed, air naturally cooled (ONAN) type, with external cooling tubes / radiators, double wound core type, copper wound having voltage ratio 11/0.433KV corresponding to principal tapping, Delta connected primary winding (HV side) and star connected on secondary wineding (LV side) in accordance with vector group DYN-11 (Vector group 4) with neutral brought on LV side and, with automatic voltage regulation in suitable step / position on HV side for constant output so as to alter / vary secondary voltage of +/- 5 to 10 % in steps of 2.5% by means of manual offload tap changing arrangements complete and confirming to IS 2026 Maximum losses of transformer shall be energy efficiency level 3 as per IS-2026, No load loss 1 KW, Insulation level HV 75/28,(KVp/KVrms), LV--/3(KVp/Kvms), weight in Kg Core & Winding, Dimensions in mm (LBH) Termination H V Side / LV Side/Orientation in Cable Box / 180 Degree, Painting for Epoxy-631, Temperature rise in Oil 40 degree C and winding 45 deegree C, Having percentage of impedance not less than 4.50% complete with all standard fittings and accessories, gauge, first fittings of transformer oil etc complete all as specified and comprising with the following fittings and accessories :-(a) Externally hand operated off-circuit Tap changer switch with position indicator and locking device.(b) Conservator with oil gauge, filling hole with plug & drain hole with plug(c) Under carriage with four plain rollers(d) Rating plate & Diagram plate - 01 NO(e) Lifting rugs fot Transformer - 02 Nos(f) Lifting lugs for lid - 02 Nos(g) Eartheing terminals - 02 Nos(h) Thermometer pocket - 01 NO(j) Silica gel brether - 01 No(k) Buchholz relay and level indicator, oil gauage, expulsion vent, bushing, thermometer, Transformer wheels, drain valve.Note:- Necessary formwork including foundation as per OEM recommendation.
157Supplying, Laying connecting & testing and commissioning of XLPE insulated, PVC sheathed, armoured HT electric power UG cable (heavy duty with stranded aluminum conductor) of size 95 Sqmm, 3 core, 11000 Volts(Earthed) grade UG cable , confirming to IS-7098 (Part-II) laid through duct/ pipe / in trench , along poles or passing through pipes or laid under floor or through walls etc. with cable glands & suitable size of aluminium lugs complete all as specified and as directedNote :- Excavation and earth work, sand cushioning and precast concerte cable cover fro protection of cable shall be measured and paid separately.
158Supply, jointing & testing, outdoor end terminal jointing kit (Cold Shrinkable) complete with jointing material and accessories suitable for 3 core , 11 KV (Earthed) grade, HT underground XLPE insulated armoured aluminium conductor . 3 core, 95 Sqmm size cable complete all as specified and as directed.
159M & L for lightining arresters explusion type 11 KV grade complete with all fittings, transmission class, discharge capacity 65 Kilo Amps complete all as specified and as directed
160S&F Disc type insulator, porcelainpolymer type, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly including nuts and bolt of working pressure 11000 volts grade complete all as specified as directed
161S&F triple pole, mechanically operated air break isolator (GOD)/ Isolator vertical / horizontal mounting, mounted on insulator and steel frame, with operating mechanism worked from ground level complete in all respect suitable for 11000 volts grade, 50 Hz with 9 insulator of current rating upto 400 Amps complete all as specified as directed
162S&F Drop out expulsion fuse unit suitable for 11 KV of capacity upto 100 Apms mounted on MS Channels complete with two post insulator 11 KV including required hard ware like clapms nut bolts washers synthetic bonded fuse barrels etc all as specified and as directed.
163Supply and fixing GI pipes 50 mm bore (dia) light grade with all fittings as in protection of UG cables for passing of cable under road, on wall or on pole with and including clamps, nuts, bolts etc including cutting chases to walls / floor and making good surfaces complete all as specified and as directed.
164Supply and fixing GI pipes 80 mm bore (dia) light grade with all fittings as in protection of UG cables for passing of cable under road, on wall or on pole with and including clamps, nuts, bolts etc including cutting chases to walls / floor and making good surfaces complete all as specified and as directed.
165Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 120 Sqmm 3.50 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc complete all as specified and as directed
166Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 70 Sqmm 3.50 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc complete all as specified and as directed
167Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 25 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc complete all as specified and as directed
168Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc complete all as specified and as directed
169Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to 23cm thickness complete all as specified and as directed.Note :- Punned down thickness shall be measured and paid.
170Material and labour for brick sub class B bricks laid in trenches as in cable protection for UG cable complete all as specified and as directed
171M&L for PCC 1:3:6, C1 (using 20mm graded stone aggregate) as in coping/collar for poles including necessary form work and finished to exposed surfaces even and fair without using extra cement complete all as specified and directed.
172M&L for Cable route indicator showing \\" MES HT / LT 11 KV UG Cables\\" and route of cable with arrow made of CI in suitable eliptical shape fixed on angle iron of size 40mm x 40mm x 6mm, 800 mm long painted in brown colour with two coats of synthetic enamel paint over a coat of red oxide primer duly embeded in and including PCC block of 0.40x0.40x0.40 in ground complete all as specified and directed.
173Supply and laying un-reinforced precast concrete cable cover, class HV, type 1 flat size 300mm x 180mm x 40mm complete all as specified and as directed
174Supply and fixing TPN DB, 4 way acrylic door 415 volts AC for flush mounting with 100 Amps copper busbar, neutral bar, earth bar and MCB incommer of rating upto 100 Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection complete all as specified and as directed
175Supply, install, testing and commissioning of out door type LT Panel outer door type , CPRI approved , platform mounted factory made of size 1.2 x 1.0 x 0.6mtr , totally enclosed dust and vermin proof openable from both front and rear side made out of 14 SWG (3.15 mm ) thick CRCA sheet of suitable size and MS angle iron section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 90 cm above and 45 cm below the ground level, frame factory fabricated with front and back openable double door system (Each door hinged with body at 4 places with body and hinges should be welded with body and door), lifting lugs (2 Nos) , lockable/ openable by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely dust/vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, approved from CPRI for 35 MVA rupturing capacity at 415 Volts, earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plates and passivated nut, bolts, spring and washers. The cabinet and all members shall be chemically treated with MSR solution for anticorrosion treatment followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/ vermin proof and general construction . The panel should be suitable for 415 Volts, 50 Hz,3 Phase 4 wire system and internal connection should be provided with copper strips of suitable size, 04 Nos copper bus bar 400 Amps including necessary foundation work complete all as specified and directed by Engineer-in-charge. confirming to IS:8623/93 and and IEC 61439 Part I & II comprising of the following :- Incomer:-(i) MCCB, 4 pole, 250 Amps, 415 Volt AC, 35 KA rupturing capacity -01 No.(ii) Digital type Ammeter with selector switch including CT (0-400 Amp) -01 No(iii) Digital type Voltmeter with selector switch 0 to 500 Volts-01 No. (iv) Timer switches 415 V Three phase of 20 Amps rating with Contactor - 01 NoON-OFF indicating lamp with toggles switch-03 NosOutgoing:-(i) MCCB, 4 pole, 100 Amps, 415 Volt AC, 25 KA rupturing capacity-02 Nos (ii) MCB, TPN , 10 Amps, 10 KA , `C' Series, 415 Volts -02 No.(iii) Changeover switch 125 Amps, 415 Volts - 01 No(iv) Analogue time switch ( daily time switch) with suitable power contactor 63 AMps ML-2 type, 3 Phase, 415 Volts, Auto / Manual operating switches - 01 No
176Supply, install, testing and commissioning of out door type LT Panel outer door type , CPRI approved , platform mounted factory made of size 1.2 x 1.0 x 0.6mtr , totally enclosed dust and vermin proof openable from both front and rear side made out of 14 SWG (3.15 mm ) thick CRCA sheet of suitable size and MS angle iron section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 90 cm above and 45 cm below the ground level, frame factory fabricated with front and back openable double door system (Each door hinged with body at 4 places with body and hinges should be welded with body and door), lifting lugs (2 Nos) , lockable/ openable by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely dust/vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, approved from CPRI for 35 MVA rupturing capacity at 415 Volts, earthing strip at rear side, bottom detachable gland plate complete with suitable size zinc plates and passivated nut, bolts, spring and washers. The cabinet and all members shall be chemically treated with MSR solution for anticorrosion treatment followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/ vermin proof and general construction . The panel should be suitable for 415 Volts, 50 Hz,3 Phase 4 wire system and internal connection should be provided with copper strips of suitable size, 04 Nos copper bus bar 400 Amps including necessary foundation work complete all as specified and directed by Engineer-in-charge. confirming to IS:8623/93 and and IEC 61439 Part I & II comprising of the following :- Incomer:-(i) MCCB, 4 pole, 1600 Amps, 415 Volt AC, 35 KA rupturing capacity -01 No.(ii) Digital type Ammeter with selector switch including CT (0-400 Amp) -01 No(iii) Digital type Voltmeter with selector switch 0 to 500 Volts-01 No. (iv) Timer switches 415 V Three phase of 20 Amps rating with Contactor - 01 NoOutgoing:-(i) MCB, 2 pole, 40-63 Amps, 230 Volt AC, 10 KA rupturing capacity, `C' series -05 Nos (Spare - 2 Nos) (ii) MCB, TPN , 16 Amps, 10 KA , `C' Series, 415 Volts -03 No.(
177Supply and fixing copper strip 20mm x 3.15mm for earthing complete with saddles and fixing screw for fitting the strip for earth contunity conductor up to test points complete all as specified and as directed.
178Supply, fixing, testing and commissioning of solar street light fitting LED 30 watts high AIO power LED delivers system lumen output > 150LM/W including all in one with MPPT charge controller, galvanised steel pole in built, confirming to IP-65 Power Supply ≥ 80% with No UV or IR radiation Lithium FERRO PHOSPHATE battery with dusk down PIR sensor not less than 100 Ah mono-crystaline solar panel, charge controller with dusk down PIR sensor fixed on and including 65mm mild steel pipe including earthwork, PCC , complete with all necessary accessories as directed. Please Enable Macros to View BoQ information
179Supply, fixing, testing and commissioning of solar street light fitting LED 30 watts high AIO power LED delivers system lumen output > 150LM/W including all in one with MPPT charge controller, galvanised steel pole in built, confirming to IP-65 Power Supply ≥ 80% with No UV or IR radiation Lithium FERRO PHOSPHATE battery with dusk down PIR sensor not less than 100 Ah mono-crystaline solar panel, charge controller with dusk down PIR sensor fixed on and including 65mm mild steel pipe including earthwork, PCC , complete with all necessary accessories as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58646497
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 23.55 Crore
LAST DATE 19-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of Otm Accn At Fasf Kanchrapara Under Ge Barrackpore
Basic Detail
Tender No 89121/E8
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 20 Nov 2026
Submission Date 19 Dec 2026
Open Date 26 Dec 2026
Finance
Tender Value 23.55 Crore
Tender Fee 3000
EMD 15 Lakhs
Exemption Available
Document List
Arch_Drawing_FASF.pdf
b8670cab-5193-4cca-a810-a0fddf342093.html
BOQ_896372.xls
Structural_Drawing.pdf
TD_Drawing.pdf
Tenderdocuments89121.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 28 days
Dec 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 35 days

Tender Documents

Download All (ZIP) ↓
pdf

Arch_Drawing_FASF.pdf

html

b8670cab-5193-4cca-a810-a0fddf342093.html

xls

BOQ_896372.xls

pdf

Structural_Drawing.pdf

pdf

TD_Drawing.pdf

pdf

Tenderdocuments89121.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender