Housing Urban and Rular Development Government Departments Closing in 8 days TDR #58646433

Tender For Construction Of 25Mtr. All Weather Warm Up Swimming Pool With 5 Years Operation And Maintenance At Khel Gaon. 6401

Issued by Government Departments · Udaipur, Rajasthan
Tender Value
4.85 Crore
Estimated cost
Bid Submission
30 Nov 2026
8 days left
EMD
9.70 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of 25Mtr. All Weather Warm Up Swimming Pool With 5 Years Operation And Maintenance At Khel Gaon. 6401

BOQ

Name of Work:- Construction of 25Mtr. All Weather Warm Up Swimming Pool With 5 Years Operation and Maintenance at Khel Gaon. 6401
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
2Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof in 1.26.1 All kinds of soil
3Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion)
4Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded
5Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift
6Providing and laying in position Ready mix concrete manufactured in fully automatic Batching Plant and transported to site in transit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge. All works upto floor V floor M20 grade Design Mix by using cement as per codal provision.
7Add extra for providing richer mixes respectively at all floor levels : Providing M-25 grade concrete by using cement as per codal provision instead of M20 grade design mix
8Centering and Shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
9Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
10Providing and fabricating reinforcement for RCC work including straightening, cutting, bending, placing in position in binding (including cost of binding wire) all complete up to floor three level Thermo mechanically treated bars(conforming to relevant IS code.)
11Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Morta 1:6 (1Cement:6 Sand)
12Random rubble dry stone Kharanja under floor.
13Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 4 (1 cement : 4 coarse sand)
14Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of Tiron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension).
15Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately). 16.1.1.3 Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron)
16Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With glass panes of 5.0mm thickness(weight not less then13.50 kg/sqm) as per IS:2835
17Filling the gap upto 5 mm depth and 5 mm width in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineerin-charge compl
18Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-charge . Polyster powder coated minimum thickness 50 micron aluminium
19Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With stainless steel cover plate
20Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304
21Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
22Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish : 20mm thick
23Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.
24Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats)
25Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20 mm thick
26Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
27Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification :
28Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm
29Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required.0.63 mm thick with zinc coating not less than 275 gm/m
30Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
31Short point (up to 3 mtr.)
32Medium point (up to 6 mtr.)
33Long point (up to 10 mtr.)
34Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
35Long point (up to 10 mtr.)
36Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
37On board
38Medium point (up to 6 mtr.)
39Long point (up to 10 mtr..)
40S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
4120 mm
4225 mm
4332 mm
44Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
453x 1.5 sq.mm
462 x 2.5 sq. mm. + 1x1.5sqmm
472 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
484 x 10.0 sq.mm
491 x 6.0 sq.mm
504 x 16.0 sq.mm
511 x 10.0 sq.mm
52S&F following sizes of ISI marked ( IS:14927 P - II ) virgin material UPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
5332 mm x 12 mm
54100 mm x 50 mm
55Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 & confirming to TEC specification GR / WIR/06-03 March 2002 in existing surface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR :: 2 pair
56P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
57Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
58Single pole MCB (With B/C curve tripping Characteristics)
596 A to 32 A rating
60Four pole MCB (With B/C curve tripping Characteristics)
6150/63 A rating
62Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
63Metal door (single phase) IK-09 and IP-43 with Metal end box
646 Way (6+2)
65Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
66Double door IK-09 & IP-43 with Metal end box
678 Way(8+24)
68P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
6920 amp, 2 pin + scrapping Earth, 1 Module
70Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 35 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
71Two pole 100/300mA sensitivity
7263 A rating
73Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
74Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal end box
758 Way
76Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
77RJ-11 telephone jack single line
78Blanking plate
79Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
80Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
815 step fan regulator 2 Module 360 dgree rotating
82Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
831/2 Module
84Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
85Providing & Fixing of Wiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
861-2 Module
87Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
8810.0 Sq. mm
894 core
9016.0 Sq. mm
914 core
9225.0 Sq. mm
933.5 core
9470.0 Sq. mm
953.5 core
96300.0 Sq. mm
973.5 core
98400.0 Sq. mm
993.5 core
100Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
101Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :-
102(a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole
103(b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts
104© Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt
105(d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.
106(d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.
107(e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
10817.2 mm thick and 3 Mtr. Long
109Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
11025mm x 3mm Alum. Strip
111Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
1128 SWG G.I. ( Hot Dipped ) Wire
113Providing & Fixing of 450 mm Sweep Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Sintered Iron bush oil impregnated, with metal front and back 120 or more ribs guard; Three no. Aluminium blades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
114Wall mounting type with Adjustable Vertical Angle
115Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
1161200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
117Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
118300 mm sweep
119P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as reqd. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
120Up to 380 mm size
121Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
122Up to 457 mm size
123Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
124450 mm sweep(900/1400 RPM)
125Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
1261170mm(+/-10%) LED batten with min. lumen output 2200 lm
127Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
128High Power LED Flood Light Minimum lumen output 8700 lm
129Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action adjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloy connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
13035 Ltr.
131SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-
132(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided
133(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.
134[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )
135(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.
136(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.
137(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )
138(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.
139(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
140Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
141Electrolytic grade Aluminium bus bar 6010 grade
142Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
143Three phase Ammeter with Inbuilt Selector Switch
144Three phase Voltmeter with Inbuilt Selector Switch
145Three phase AMP + HZ + PF + KW + KVA + KVAR + KVARH+KWH+DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS
146Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
147Ring type tape wound CT
148C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA
149C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA
150Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
151Red/yellow/Green colour
152Blue / white Colour
153Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
1541.5 Sq. mm
1552 core
156S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
15725 mm
158Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
159Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
160150mm x 50mm x 1.6mm
161300mm x 50mm x 1.6mm
162450mm x 50mm x 2.0mm
163P & F of Direct on line (DOL) / Star - Delta Starter as per IEC type-2 Co-ordination chart of OEM in Existing Panel with circuit breaker having inbuilt overload protection or separate thermal Overload relay , Short circuit, phase loss protection, suitable Contactors, including wiring between switchgears, Indicating lamps for R,Y,B,ON,OFF, Push button for ON, OFF, Volt meter, Ammeter, selector switch for local/remote, auto/manual/OFF operation. Cast resin CT's, provision for potential free contacts making connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
164Direct on line (DOL) Starter with following Motor rating
165Motor rating 9.0 KW
166SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
1674 pole MCCB With Thermal Magnetic release
168up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting
169125 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
170160 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
171630 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
172Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
173Double pole MCB(With B/C curve tripping Characteristics)
1746 A to 32 A rating
175Supply, Instalation, Testing & Commissioning of anti-corrossive bobbin wound Fiber Glass side mount Sand Filter having size of 1200 mm dia & flow rate 56.5 m³ per hour at maximum working pressure is 2.5 kg/cm², maximum operating temparature 50 degree celsius .complete with collector arms and diffusers made from unplasticised PVC and polypropelene , pressure gauge ,manual bleeder ,water drain ,empty drain for filter etc , as directed and approved by Engineer in charge. (Make :-Watermate/ ASTRAL/ Aquanomics/ Aqvastar or equivalent company)
176Supply, Instalation, Testing & Commissioning of Multi-Port Valve (special polymer made 6-way multiportvalve (bolts mounted) with lever action handle with quick connect barrel unions with BS/ASTM connnection, integral sight glass for watching backwash cycle, manometer with air bleed apparatus for monitoring and varying the pressure of filteration system ) assembly suitable for 56.5 m3 filter of 1200 mm dia complete with all accessories- as directed and approved by Engineer in charge. Make :- Watermate /ASTRAL/Aquanomics/Aqvastarr or equivalent company
177Supply, Installation & Commissioning of Centrifugal Recirculation Pump with Leaf Strainer. Port Size: 2\\" x 2\\" Phase:Three Power: 4.0 HP, 8 m Head, Electric Motor working on 400/440 V, 50 Hz , 3 Phase Electric supply, corrosion resistant , high grade stainless steel motor shaft ,2850 RPM motor, high chemical resistance with all metal internal components being stainless steel complete with all fittings as directed and approved by Engineer in charge. Make:Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company 40 m³ / 8 mtr Head
178Supply, Installation & Commissioning of Surface Mounting SS Under Water LED Lights of 18W-12V ,I.P.68,Illuminance of 415with stainless steel face ring and with waterproof standard and with1.5SQ.MM-3Core Copper Cables for Under Water LED Lights from Filter Plant Room and up to the LED Light Fixtures including conduits, tee, elblows, bend, junction box etc for underwater light as directed and approved by Engineer in charge. Make:Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
179Supply, Installation & Commissioning of LED Lights Transformers suitable to operate 18W - 12V Underwater LED lights,I.P.68,Illuminance of 415 with complete as directed and approved by Engineer in charge. Make:Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
180Supply & Installation, Testing & Commissioning of Dosing Pumps capacity , 0-5 ltrs per Hour. power 12 V, Pressure 8 Bar, Complete with 6 Amp Switch Socket arrangement as required FRP Tank for preparation of solution, Capacity 100 ltrs. with stirrer etc. complete.as directed and approved by Engineer in charge. (Make :- Watermate/Oceanstar/ EDOSE/Nuton/Accord)or equivalent company
181Supply & Installation, Testing & Commissioning of Anti vortex Pool ABS main drain cover base plate of size 300 mm x 300 mm as directed and approved by Engineer in charge. - Make: Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
182providing and fixing of ABS pool floor inlet nozzel as directed and approved by Engineer in charge. - Make: Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
183Supplying Electric Control Panel suitable to operate filtration system with GSM Based Real-Time Monitoring System having necessary sensors & Web-based application to indicate the following parameters-1. Hours of Operation2. Flow3. Chlorine Level4. Turbidity5. pH LevelAlso including, flow meters, flow sensors, sampling valves, single board computers with USB & HDMI port, pen drive for data logging, modem for real time monitoring and 1nos 32” LED Display screen. Make:Watermate /ASTRAL/Aqvastar
184providing and fixing 304 grade 5-steps stainless steel ladders with anti skid pads with proper anchoring , safe handrail as directed and approved by Engineer in charge. Make:Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
185providing and fixing 304 grade Stainless Steel Trolley mounted suction sweeper pump of 1.0 HP with cartez filter ,SPOM type as directed and approved by Engineer in charge. Make: Kirlokar / Lubi / Texmo or equivalent company
186providing Delux pro leaf net bag type as directed and approved by Engineer in charge. Make:Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
187providing Delux wall brush 18\\" long heavy duty, long lasting bristles with rugged high grade polumer handle and var resistant bumper design with aluminium back as directed and approved by Engineer in charge. Make:Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
188Providing Stainless steel algae brush 250 mm heavy duty stainless steel bristles asdirected and approved by Engineer in charge.Make: Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
189Providing 24\\" Stainless steel vacuum head with wheels, brush, wiper and 80 m towing rope as directed and approved by Engineer in charge.Make: Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
190Providing Floating Hose pipe 15 M as directed and approved by Engineer in charge.Make: Watermate /ASTRAL/Aquanomics/Aqvastar
191Providing Standard Telescopic handle 1.2m-2.4m of aluminum as directed and approved by Engineer in charge.Make :Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
192Providing Standard Telescopic handle 2.4m-4.8m of aluminum as directed and approved by Engineer in charge.Make :Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
193Providing Basic pH and CI test kit as directed and approved by Engineer in charge.Make :Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
194Providing Hardness Test Kit as directed and approved by Engineer in charge.Make :Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
195Providing TCCA-90 chlorine granules for disinfection as directed and approved by Engineer in charge.Make :Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
196Providing and fixing Aluminum life saving hook as directed and approved by Engineer in charge.Make :Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
197Providing and fixing Lifebuoy made of UV grade PE & PU foam filled, round shaped with retro reflective tape and grab line as directed and approved by Engineer in charge.Make :Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
198Providing and fixing Life Jacket made of durable, water resistant fabric that resist chlorine and UV degradation as directed and approved by Engineer in charge.Make :Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
199Supply, Installation, Testing & Commissioning of UV Sterilizer with Housing outside, U.V. Lamp of 75 W, glass tube and all other accessories with supports, inlet outlet connection with bypass arrangement complete with required accessories.as directed and approved by Engineer in charge. Flow rate = 42 M3/Hr. working Pressure = 2.5 Kg/Sqm Make: Watermate /ASTRAL/Alfaa UV/Aqvastar or equivalent company
200HYDRAULIC WORK FOR SWIMMING POOL : PUMP SUCTION PIPIING: Supply installation & commissioning of Recirculation pump piping dia 10kg/cm2 UPVC pipe from balance tank up to circulating pumps suction with Foot valve, elbow, strainer, pipe end MS Silicon flange, rubber gasket, nut bolt etc. complete as per requirement of plumbing Supply installation & commissioning of filter room piping from pumps dia 10kg/cm2 PVC pipe main 110 /90/75/63/50mm size with control valve and Non return Valve etc.complete. Supply installation & commissioning of filter room piping from pumps dia 10kg/cm2 PVC pipe main 110 /90/75/63/50mm size with control valve and Non return Valve etc.complete. WATER RETURN LINE PIPE VELOCITY : 2.5M/SEC Supply installation & commissioning of delivery UPVC piping from filter room to swimming pool inlet 10 KG 75/65/50mm pipe size filter room up to the bottom distributing piping inside the swimming pool complete with elbows, pipe ends, MS silicon flanges Supply, Installation & commissioning MS nut and Bolt rubber gasket GI nut bolt etc.complete BOTTOM of PVC bottom distribution piping in 75/63/50mmOD/10 kg pressure pipeOVERFLOW LINE PIPE VELOCITY : 0.8M/SEC Supply installation & commissioning of Over Flow piping in PVC pipe 160mm from swimming pool overflow water channel collection pit & up to thebalancing tank. SUCTION LINE PIPE VELOCITY : 1.2 to 1.5M/SEC Supply installation & commissioning of wall vacuum point piping from swimming pool to main circulation pump 63 MM dia 10kg/cm2 pipe main to main UPVC header of 110mm size with control valve and Non return Valve etc. complete. Supply installation & commissioning of drain piping in UPVC 60mm/10kg size from main drains located inside the swimming pool & up to balancing tank bottom complete CI valve & operating MS handle, abs Drain plate of size 110mm with base frame connectors with flanges & Nut bolt etc. complete with elbows, pipe ends, MS silicon flanges MS nut and Bolt rubber gasket GI nut bolt etc. complete All pipes shall be of ISI mark, Supreme/finolex/astral/prince OF 10KG/CM2. All PVC / PP valves shall be of minimum PN10 ratingAll standard fittings like bends, elbows, tees etc. should be of similar rating of the pipes. However, in cases where special fittings are required and the same are to be fabricated on site due to non-availability anywhere in the Indian market, then the contractor has to ensure that the fittings are fabricated of high grade chopped PVC fiber/ ravings and should be capable of withstanding working pressure of at least 10kg/cm2 and drain pipe 4/6 kg/cm2 PRINCE/ SUPREME/ ASTRAL /ASHIRWAD/ DUTRON/EQUIVALENT
201Providing & applying Waterproofing Treatment to Pool Walls and Floor using polymer modified 2-component cementitious compound and latex coating applied using brush, micro-concreting, injectiongrouting and fiber mesh work is done at wherever necessary1. Cleaning of the targeted surface2. Repairing with micro concrete, epoxy grouting, injection grouting and fiber meshetc. wherever necessary3. Pressure grouting with manual (140PSI) / machine work (40 PSI) wherever necessary4. Two coat of bonding agent (1:3:3 - chemical: water: cement)5. Two coat of single component acrylic polymer for modified cementitious chemical composition asdirected and approved by Engineer in Charge.Make- Pidilite/MYK Arment/Perma
202Providing & Fixing approved brand tiles of size 50mm x 50mm Porcelain Pool Mix Mosaic Tiles withthickness of 8mm of 0.032% water absorption general chemical acid resistant fixing by Laticrete/JKCement/Kerakoll/MAPEI make White Mosaic Adhesives and White Epoxy Grouting fixing by FINAstandards specifications or as per lane marking of swimming pool complete as directed by Engineer incharge.Make- Italia/Piccolo/Keramika/Onix/ Mossaico or equivalent company
203Providing and laying ANTI SKID designer floor tiles for deck area (Simpolo/ Larson/ Pavit/ eqv.) thickness to be specified by the manufacturer of 1st quality conforming to IS 15622 of approved make in colours shade except white ivory grey fume red, brown laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand)
204Supply, fabrication and installation of Arch Shaped Galvalume Roofing (Proflex Roofing) as per specification mentioned below-Providing and laying Proflex roof system with all required materials as per manufactures specification with proper provision of skylights,hangers ,turbo ventilator exhaust system and anchor properly with R.c.c. Gutter beams completed with all respect as directed by engineer incharge ,minimum 1.20 mm pre fab sheeting by proflex systemThe material of Galvalume Steel to comply the following specification:1) Make any of the following from the Market,a. Thyssen krupps, Germanyb. Dongbu Steels Co. ltd. Koreac. Corus Steel, UKd. Dofasco Steel, Canadae. Bethelethem Steels, USA2) Technical Details:a. Standard Color Coated Galvalume Steel complying to ASTM A792b. Base Metal Thickness – 1.20 MM MIN.c. Alloy Coating – AZ150 (Aluminium 55%, Zinc 43.5%, Silicon 1.5%)d. Yield Strength – 350 Mpae. Paint Coating – Regular Modified Polyster, Top Coat 25 micron & Bottom Coat 12 micronf. Color Pattern – Combination of Blue & White (Ratio 50% each)
205Supply, installation & commissioning of glass filter media for commercial sand filter - Make: Watermate /ASTRAL/Aqvastar
206providing amd fixing ABS gratings in white color 12\\" wide, heavy duty with non slip surface for safety , manufactured in weather proof ( UV protected ) polypropylene for long life as directed and approved by Engineer in charge. Make:Watermate /ASTRAL/Aquanomics/Aqvastar or equivalent company
207304 grade 4-steps stainless steel ladders with anti skid pads Make:Watermate /ASTRAL/Aqvastar
208Starting Blocks for jumping with adjustable non-slip platform along with all anchoring fixtures and numbering as per FINA specification.Make :Watermate /ASTRAL/Aqvastar
209Supply, Installation, Testing & Commissioning of Water Softening System with Fibreglass Softener Vessel and automatic operation complete with brine tank, mechanical stirrer, inlet outlet connections, liquid level controller and other accessoriesMake :Watermate /Novatech/Oceanstar Resin Type: Ion Exchange Resin Na 225 Resin Capacity: 900 L Vessel Size: 36\\" x 72\\" Flowrate: 10 m3/hr
210Supply, Installation, Testing & Commissioning of Inverter Type Outdoor Pool Heat & Cool Pump with metal casing and in-built spiral trube type heat exchanger having power rating 380-400 V / 3-PH/ 50 Hz.Make: Watermate / ASTRAL/ Aqvastar Type: High Perfromance Inverter Input Capacity: 115 KW Performance Condition: Air 27 degree, Water 26 degree, COP 6.0
211Providing operation and maintenance service including deployement of required manpower, chemicals and consumables to maintain the pool for a period of 5 years after successful handing over of swimming pool work as per schedule. The operation and maintence shall also include all types of chemicals, consumables, repairs, wear and tear related to swimming pool filtration system and accessories. ( Civil work repairs, Electricity and Water shall be provided by the client free of cost)
2121st Year O&M
2132nd Year O&M
2143rd Year O&M
2154th Year O&M
2165th Year O&M Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58646433
AUTHORITY Government Departments
TENDER VALUE 4.85 Crore
LAST DATE 30-11-2026
Authority
Authority Name Urban Improvement Trust
Work Description Tender for Construction Of 25Mtr. All Weather Warm Up Swimming Pool With 5 Years Operation And Maintenance At Khel Gaon. 6401
Basic Detail
Tender No NIT_64_01
Bidding Type Tender
Location
City Udaipur
State Rajasthan
Key Dates
Publish Date 20 Nov 2026
Submission Date 30 Nov 2026
Open Date 01 Dec 2026
Finance
Tender Value 4.85 Crore
Tender Fee 5900
EMD 9.70 Lakhs
Exemption Available
Document List
BOQ_1075390.xls
de5e996f-a822-4075-8627-c320705494ba.html
Financial-Bid_01.pdf
Technical-Bid_01.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Dec 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1075390.xls

html

de5e996f-a822-4075-8627-c320705494ba.html

pdf

Financial-Bid_01.pdf

pdf

Technical-Bid_01.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender