| Sl. No. | Item Description |
| 1 | Transportation of suitable truck / tractor mounted where only road available DTH and ODEX / Percussion Calyx / RC Drilling with portable rigs alongwith necessary accessories etc to the site of work and erection of portable rig including leveling etc. complete in all respect as per directions and to the entire satisfaction of Engineer-in-charge including all leads and lifts. |
| 2 | Drilling bores of 152mm Dia as per IS: 2800-1979 using ODEX (TUBEX) attachment required drilling in collapsible strata conglomerate, boulders, pebbles, gravels, silt, clay etc. including cost of attachments, consumable stores, bits, water, POL, etc. complete with system of simultaneous lowering of 125mm nominal bore 50mm thick MSERW fincut casing pipe which will be welded together using 2.5mm or 3.25mm dia Advani/Oerlikon electrodes with one plain end and the other end chamfered to 50 degree removing paint on the area to be welded, inclusive of the cost biodegradable and non-toxic foam flush etc. complete in all respect as per directions of Enigneer In Charge. MSERW fincut casing pipe, casing shoe and bit tube as per requirement of ODEX to be paid separately. |
| 3 | Supply and lowering of IS marked 125mm dia nominal bore, 5.00 mm thick finuct MSERW casing pipes as per IS 4270-2001 and requirement of ODEX attachement complete in all respect as per direction of the Engineer-in-charge. |
| 4 | Providing and Fixing suitable casing shoe and bit as requirement of ODEX attachement complete in all respect as per direction of the Engineer-in-charge. |
| 5 | Collection and preservation of soil samples in polythene bags complete in all respect as per direction of Engineer-in-charge. |
| 6 | Development of borewell and yield testing with Air compressor through V-notch and disinfection etc. complete in all respects as per IS-2800-1979 and as per direction of the direction of Engineer-in-charge. |
| 7 | Supplying and fixing 1 No. Submersible pumping set of KSB/CG/Sabar/ BS/Kriloskar make conforming to IS:8034-1976 (latest with upto date amendment) Suitable for operation on under mentioned characterstics complete as per manufacture standard including required accessories coupled directly to submersible motor suitable for operation 230 Volts single phase 50 H.Z. A.C supply minimum class 'B' insulation. The power of the motor should be 10% in excess of maximum powers required by the pump in the complete range of (-) 25% and +10% of duty point head. The motor should be conforming to BIS 325-1970 and latest with up to date amendments and also complete earthing with copper strips as per HPSEB rules and IS code 3043-1966 of latest. The pump set should be capable of following performance: -Total No. of Set Requred = 1 No. Total discharge required: = 1.00/2.00 LPS each pump,Dia of bore: = 125 mm dia, Total Head: = 100-105 mtrs, HP Motor = 2.00 HP.Dia of rising main = 32/40mm dia |
| 8 | Supplying and fixing of jointless flat submersible cable of suitable size of 3x2.5mm² upto required length as per site conditions complete in all respect encluding all leads & lifts as per direction and to the entire satisfaction of Engineer-in-Chief. |
| 9 | Providing & fixing MS angle & MS sheet febricated control pannel, Pannel board having size 1.10mtr height overall i/c two compartment of size 0.50x0.50x0.30m vertical angle frame 35x35x4mm, horizontal angle 25x25x4mm thick (BG18 gauge) i/c electrical accessories Ammemeter, Voltmeter, ICTP switches with HRC fuses, Bus-bar chamber, MCB/OCB, 3 phase indicating lamps with Toggle switches, DOL starter oil-immersed, Capacitor, overload relay etc i/c locking arrangement/ duly painted complete in all respect as per relevent code and specifications as per the direction and to the entire satisfaction of Engineer-in-Charge. |
| 10 | Providing, laying, jointing, and fixing of three-layer PP-R (Polypropylene Random Copolymer) / HDPE pipes, UV-stabilized and antimicrobial, having thermal stability suitable for hot and cold water supply, including all PP-R plain and threaded polypropylene random fittings, complete as per ISI 15801:2010, including testing of joints, complete in all respects with all leads and lifts, as per the direction and to the entire satisfaction of the Engineer-in-Charge. |
| 11 | Providing & fixing of high steel carbon rope size 5mm squre for holding of submersible pump set complete in all respect within all leads and lift as per direction and to the entire satisfaction of Engineer-in-Charge. |
| 12 | Supply and fixing of ISI-marked Gunmetal Reflux Valve of 40 mm diameter of reputed make, complete in all respects, including all leads and lifts, as per the directions and to the entire satisfaction of the Engineer-in-Chief. |
| 13 | Providing and fixing MS supporting clamps of suitable size, made of MS flat, including nuts, bolts, rubber sheet, washers, etc., complete in all respects, including all leads and lifts, as per the direction and to the entire satisfaction of the Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender