Housing Urban and Rular Development Government Departments Closing in 6 days TDR #58646087

Tender For Supplying, Installation, Testing And Commissioning Of Automatic Misting System At Road No. 57. (Sh: Civil And Electrical Work).

Issued by Government Departments · Delhi, Delhi
Tender Value
2.48 Crore
Estimated cost
Bid Submission
27 Nov 2026
6 days left
EMD
4.96 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supplying, Installation, Testing And Commissioning Of Automatic Misting System At Road No. 57. (Sh: Civil And Electrical Work).

BOQ

Name of Work:- Supplying, Installation, Testing and Commissioning of Automatic Misting System at Road no. 57. (SH: Civil and Electrical Work).
Sl. No. Item Description
1(Electrical Work)Supplying and laying of stainless steel (SS) pipe of size 25mm OD is designed for high- pressure misting systems up to suitable depth below the ground level with trenching and backfilling, capable of handling operational pressures between 40 to 80 bar. Made from durable, corrosion-resistant stainless steel, this seamless pipe ensures reliable performance in demanding environments, such as outdoor cooling systems, greenhouses, and industrial misting applications. Its polished exterior prevents rust and scaling, while the precision-engineered wall thickness guarantees strength and safety under high pressure. Compatible with various high-pressure fittings, this pipe meets international standards like ASTM A269/A213, making it ideal for both residential and commercial misting installations, including supplying and fixing of all other suitable accessories for connection between steel pipe and nylon pipe, cutting, welding, testing & commissioning etc. as required.
2Supplying and laying of stainless steel (SS) pipe of size 15mm OD is designed for high- pressure misting systems up to suitable depth below the ground level with trenching and backfilling, capable of handling operational pressures between 40 to 80 bar. Made from durable, corrosion-resistant stainless steel, this seamless pipe ensures reliable performance in demanding environments, such as outdoor cooling systems,greenhouses, and industrial misting applications. Its polished exterior prevents rust and scaling, while the precision-engineered wall thickness guarantees strength and safety under high pressure. Compatible with various high-pressure fittings, this pipe meets international standards like ASTM A269/A213, making it ideal for both residential and commercial misting installations, including supplying and fixing of all other suitable accessories for connection between steel pipe and nylon pipe, cutting, welding, testing & commissioning etc. as required.
3Providing & Fixing of 9mm high-pressure nylon pipe (on the exiting pole up to required height) is designed for applications requiring a pressure rating between 40 to 80 bar, making it ideal for use in misting systems, industrial automation, and other high- pressure environments. Constructed from durable, lightweight nylon, this pipe offers excellent flexibility, resistance to abrasion, and chemical stability, ensuring long-lasting performance under demanding conditions. Its smooth inner surface minimizes friction losses, promoting efficient fluid flow, while its tough outer layer withstands environmental factors like UV exposure and impact.Including supplying and fixing of all other suitable accessories for inter connection between nylon pipe misting nozzle, testing & commissioning etc. as required.
4Providing & fixing of suitable size (900 to 1200 mm) stainless steel (SS) bracket is suitable for fixing of 6 nos. multi-port with 5 spells brass nozzle on exiting pole upto suitable hight Including supplying and fixing of all other suitable accessories for inter connection between nylon pipe and misting nozzle, testing & commissioning etc. as required.
5Supplying and fixing of Brass type Misting Nozzle on existing bracket ,capable for throw the water jet upto one meter radius with a discharge rate 2.8 LPH at operating pressure 50 bar, featuring a precision-drilled orifice, integrated filter, and corrosion-resistant finish, Including supplying and fixing of all suitable accessories for connection between misting nozzle and braket, testing & commissioning etc. as required.
6Supplying, installation, testing and commissioning of Ball Valve Metallic stainless steel (SS) of size 25 mm including supplying and fixing of all suitable accessories for connection, testing & commissioning etc. as required.
7Supplying & installation of Digital Irrigation Sequential controller suitable for oprating automatic misting system Including supplying and fixing of all suitable accessories like cable, wire thimble etc., connection, testing & commissioning etc. as required.
8Supplying, installation, testing and commissioning of Pump capable for discharging water 2.1 cu meter @ 80 bar head with Min. Capacity 20 HP and NRV and header fittings complete, including supplying and fixing suitable size electric cable, base frame, panel with all fittings complete as required.
9Supplying, installation, testing and commissioning of Pump Starter Relay suitable for pump set of minimum capacity 20 HP Including supplying and fixing of all suitable accessories like cable, wire etc., connection, testing & commissioning etc. as required.
10Supplying, installation, testing and commissioning of Enclosure for Electrical Componant of suitable size. Including supplying and fixing of all suitable accessories for installation etc. as required.
11Supplying, installation, testing and commissioning of RO system of capacity 2000 ltr per hour with complete accessories like suitable pump, moter, membrane, filter etc.and including supplying and fixing suitable frame, all other suitable accessories for interconnection with water tank etc. complete as required.
12Supplying and laying of following PVC insulated and PVC sheathed/XLPE armoured aluminim conductor power cable of 1.1 KV grade of following size.
133.5 X 50 sq. mm armoured aluminum conductor power cable
144 X 25 sq. mm armoured aluminum conductor power cable
15Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
1663 mm dia (OD-63 mm & ID-51 mm nominal)
17Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.100 A, 16 KA,TPMCCB
18SH:-II Comprehensive Maintenance including Operationoperation by providing 1 no of operator in two shifts (6am to 2pm & 2pm to 10pm) including cleaning of equipments etc. complete as required. - 1 Joba) Bihari Colonyb) Jagat puri
19Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
20Group C
21Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
22Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
231200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
24LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
2518- 22 Watt
26LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
27100 watt
28Providing round the clock security guard without gun for watch & ward of Government premises and its all belongings by deploying neatly dressed security guards in 8 hour’s shift including necessary T&P like torch, lathi and uniform etc. complete, as per the direction of Engineer-in-charge. (One job means 8 hour's duty).
29Civil WorkEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All kinds of soil.
30Excavating trenches by mechanical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides ramming of bottoms, for all depth , including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
31Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
32Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. All kinds of soil
33Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level a)1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
34Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level a) 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
35Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
36Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
37Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
38Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
39Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
40Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: A) Cement mortar 1:6 (1 cement : 6 coarse sand)
41Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
42Providing and fixing plain lining with necessary screws/nuts & bolts/nails including a coat of approved primer on one face and fixed on wooden /steel frame work, complete as per direction of Engineer-in-charge. (Frame work shall be paid for separately) 12mm thick commercial ply conforming to IS : 1328 BWR type.
43Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
44Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
45Hot finished welded type tubes
46Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
47Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of Size of Tile 600 x 600 mm
48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
49Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sgm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
5015 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
51Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
52On steel work
53Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or more coats on new work
54Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
55Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :bituminous road
56Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
57Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge.
58Made of G.I. wire of dia 4 mm
59Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. 20 mm nominal dia Pipes
60Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
61(a) 25 mm nominal dia Pipes
62(b) 50 mm nominal dia Pipes
63Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore
64Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore
65Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
66Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter
67Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
68Providing and fixing pre-fabricated frisking shed of size 10’x15'x 8’ (external dimension) consisting of 12 mm thick cement particle board (Bison make) wall up to the height of 1.20 mtr.and rest shall be covered by 5.5 mm thick plain sliding glass on properly anodised Aluminium section E section 25mm X12mm, 1.60mm thick incased in M.S. tubular frame vertical post tube size 48 x 48 x 3mm thick and horizontal tube 48x24x2mm thick by M.S. angle from out side (size 25 x 25 mm ) and M. S. channel (12x12x1mm thick) from inside. The roofing of the frisking shed will be in the shape of dome made of M.S. tubular frames with roofing of 12mm thick B.W.P. plywood of ISI make one which plain Aluminum sheet fixed on top with approved adhesive and nails as per standard design. The entire work shall be painted with synthetic enamel paint with base coat of primer all complete with transportation and erection at site. as per direction of Engineer-in charge. as per sample/ pattern apprved.
69DSR 2023 correction factor is 0.973 as per OM 158/SE(TAS)/GST/2024/02-E dt.08/08/2024
70Cost index @ 4.03%
71Providing & Fixing FRP Toilet in the size of 3.5 ft x 3.5 ft x 7 ft in a Wall Thickness of 3 mm with semi circular Roof top provided with a Wash Basin, lights inside and outside and an Exhaust Fan size 150 mm and Base disposal syphon (murqi) & Foot Rests.
72Providing and fixing Hot compressed molded SMC (sheet molding compound) panel tank of Brand AMITEX DEVI POLYMERS, SINTEX, as per BIS: 141399 Part-I & Part-II. ISI Marked SMC Panel Tanks of approved brands. Roof & Base of SMC Panel tanks having panels of size 1.00 meter x 1.00 meter, 1.00 meter x 1.05 meter side walls of tanks shall be constructed usning SMC panels of size 1.00m x 1.00m panel (tank size 8x10000 ltr. = 80000 ltr. capicity) as per site requirement. One mahole of diameter 600mm should be provided on the roof of tank with lockable lid and aluminium ladder above 1 mtr. height inside & outside the tank for access. Tanks must have vertical iron posts tied firmly with Tie rods. The panel should withstand Hydrostatic pressure of at least 4 times the working load and should be provided with HDG bolts, nuts, washer, food grade foam gasket, cleats, including PVC pipe support of 110mm dia for the roof of top panels. Tank shall be erected on steel base (item of design steel base to be paid separately) which must be kept at RCC base foundation at site as per manufacturer's specifications & design. Inlet and Outlet, overflow & drain should be provided with tank. The Tank installation work will be carried out at roof of building/ground level. (Note:- The tanks panels must be printed with ISI Logo, ISI Certification Number, CML Number, Batch Number etc.)
73Supply of water through Tanker of Capacity 10000 litre with 50 mtr delivery pipe of 4-6'' dia to utilize water for Mist Spray System including One Beldar, Cost of water & fuel & all other T&P etc. complete as per direction of Engineer-in-charge. Daily supply of unfiltered water will be 4 to 6 tanker on regular interval basis/ as per requirement between 6:00 AM to 8:00 PM. (Payment shall be made as per No of trip) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58646087
AUTHORITY Government Departments
TENDER VALUE 2.48 Crore
LAST DATE 27-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Supplying, Installation, Testing And Commissioning Of Automatic Misting System At Road No. 57. (Sh: Civil And Electrical Work).
Basic Detail
Tender No 09/SE/SHAHDARA CIR. M/PWD/NIT/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 20 Nov 2026
Submission Date 27 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value 2.48 Crore
Tender Fee Ref. Documents
EMD 4.96 Lakhs
Exemption Available
Document List
631125dc-fe4e-48ed-963a-4a0dd8685f6e.html
BOQ_402646.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

631125dc-fe4e-48ed-963a-4a0dd8685f6e.html

xls

BOQ_402646.xls

pdf

Tendernotice_1.pdf

Disclaimer